battery: fixed remaining time on connected AC
when an AC is connected apm_info shows a non-valid value for remaining minutes. it was decided that in that case the function should return an empty string.
This commit is contained in:
		
				
					committed by
					
						
						Aaron Marcher
					
				
			
			
				
	
			
			
			
						parent
						
							2604f25b16
						
					
				
				
					commit
					367f8a8c44
				
			@@ -121,8 +121,12 @@
 | 
			
		||||
		struct apm_power_info apm_info;
 | 
			
		||||
 | 
			
		||||
		if (load_apm_power_info(&apm_info)) {
 | 
			
		||||
			return bprintf("%u:%02u", apm_info.minutes_left / 60,
 | 
			
		||||
			               apm_info.minutes_left % 60);
 | 
			
		||||
			if (apm_info.ac_state != APM_AC_ON) {
 | 
			
		||||
				return bprintf("%u:%02u", apm_info.minutes_left / 60,
 | 
			
		||||
				               apm_info.minutes_left % 60);
 | 
			
		||||
			} else {
 | 
			
		||||
				return strdup("");
 | 
			
		||||
			}
 | 
			
		||||
		}
 | 
			
		||||
 | 
			
		||||
		return NULL;
 | 
			
		||||
 
 | 
			
		||||