Fix openQA Helm Chart installation
All checks were successful
Build / build (push) Successful in 19s
All checks were successful
Build / build (push) Successful in 19s
This commit is contained in:
@ -83,12 +83,6 @@ We will be working with the parent chart `openqa`. Since it references the other
|
||||
|
||||
## Installing openQA
|
||||
|
||||
By default, the openQA WebUI template only exposes ports to the local network inside minikube, which makes the WebUI inaccessible from the host system. We need to add `type: NodePort` to the port specification under `spec:` in `charts/webui/templates/svc.yml`:
|
||||
|
||||
```
|
||||
sed -i '/^[[:space:]]*spec:/a\ type: NodePort' charts/webui/templates/svc.yml
|
||||
```
|
||||
|
||||
We then have to update dependencies and install openQA:
|
||||
|
||||
```
|
||||
@ -101,7 +95,7 @@ We can also list installed releases to confirm that openQA was deployed:
|
||||
```
|
||||
$ helm list
|
||||
NAME NAMESPACE REVISION UPDATED STATUS CHART APP VERSION
|
||||
openqa default 1 2025-06-04 12:39:08.150021755 +0200 CEST deployed openqa-0.1.0
|
||||
openqa default 1 2025-06-19 12:39:08.150021755 +0200 CEST deployed openqa-0.1.0
|
||||
```
|
||||
|
||||
The minikube dashboard also lists all running pods:
|
||||
@ -111,16 +105,23 @@ The minikube dashboard also lists all running pods:
|
||||
|
||||
### Accessing openQA WebUI
|
||||
|
||||
Minikube provides a convenient way to list services and their exposed NodePorts:
|
||||
Since openQA is confined to its own network within minikube, it is not directly accessible from the host system. Below are the services running inside minikube:
|
||||
|
||||
```
|
||||
$ minikube service openqa-webui --url
|
||||
http://192.168.49.2:30765
|
||||
http://192.168.49.2:30134
|
||||
http://192.168.49.2:30333
|
||||
http://192.168.49.2:31258
|
||||
$ kubectl get services
|
||||
NAME TYPE CLUSTER-IP EXTERNAL-IP PORT(S) AGE
|
||||
db ClusterIP 10.103.192.20 <none> 5432/TCP 6m34s
|
||||
db-hl ClusterIP None <none> 5432/TCP 6m34s
|
||||
kubernetes ClusterIP 10.96.0.1 <none> 443/TCP 174m
|
||||
openqa-webui ClusterIP 10.104.24.71 <none> 9526/TCP,9527/TCP,9528/TCP,9529/TCP 6m34s
|
||||
```
|
||||
|
||||
The openQA WebUI is running on port *30765*, which is now accessible directly from your browser.
|
||||
First, we need to create a proxy within the minikube network:
|
||||
|
||||
```
|
||||
minikube tunnel
|
||||
```
|
||||
|
||||
The openQA WebUI is running at `10.104.24.71` on port `9526` and is now accessible directly from the browser.
|
||||
|
||||

|
||||
|