bmw-advanced-tools/app/EDIABAS/Source/EME_I01.B2V

21404 lines
1012 KiB
Plaintext
Raw Normal View History

2021-09-18 17:45:57 +02:00
ecu : Antriebselektronik;
origin : BMW EA-412 Flach;
revision : 0.518;
author : MicroNovaAG EA-412 Flach, IST RD-51 Thoma;
comment : AE [6];
// *******************************************************************
// SGBD-Info:
// SGBD-Erstellung: SGBD-Generator, Version 5.5.2
// Muster-SGBD: Muster_UDS.xml, Version 5.1.6
// BEST-Runtime-Library: B2Runtim.lib, Version 2.14
// BEST-BMW-Library: B2BMW.lib, Version 2.25
// Standard-Includes: UDS_PACKAGE.b2s, Version: 1.25
// ODX-Daten: ODX-Konverter, Version 3.3.0_b01
// -------------------------------------------------------------------
// allgemeine Lastenhefte:
// Lastenheft Diagnose Ausgabe 08
// -------------------------------------------------------------------
// SG-spezifische Lastenhefte:
// -------------------------------------------------------------------
// History:
// 10.02.2010 mf V0.001 Ersterstellung
// 27.05.2010 mf V0.002 +Montagemodus, +_Status_Build_Id
// 08.06.2010 mf V0.003 bugfix fs_lesen_detail, UWD f<>r Parksperre-Jobs, +_status_build_id
// 10.06.2010 mf V0.004 +_status_build_id (jobHeaderFormat)
// 17.06.2010 mf V0.005 change UWD f<>r Parksperre
// 25.06.2010 mf V0.006 DTCs f<>r DAQ
// 28.06.2010 mf V0.007 neuer Export von Zedis (DiagJobs)
// 01.07.2010 mf V0.008 DTCs f<>r DCDC
// 07.07.2010 mf V0.009 DTCs++ CAN
// 14.07.2010 mf V0.010 DTCs++ ELUP, FUSI, CAN
// 27.07.2010 mf V0.011 Energiesparmode DTC vom SC
// 06.08.2010 mf V0.012 DTCs++ DAQ
// 12.08.2010 mf V0.013 DTCs++ DAQ; <20>nderung MontageModus
// 25.08.2010 mf V0.014 DTCs++ HVSM
// 16.09.2010 mf V0.015 DTCs++ DAQ
// 04.10.2010 mf V0.016 DTCs++ Ebende3 + PS
// 08.10.2010 mf V0.017 DTCs++ HVSM
// 10.11.2010 mf V0.018 ++Parksperren-Jobs, Anpassung Rohsignal-Jobs, ++REN-DTC, Beschreibungs<67>nderung f<>r DAQ-DTCs
// 24.11.2010 mf V0.019 ++AEPH
// 08.12.1010 mf V0.020 ++EM-Fehler
// 09.12.2010 mf V0.021 Umweltdatensaetze angepasst
// 21.12.2010 mf V0.200 DTCs B2-Muster
// 17.01.2011 mf V0.201 ++Bauteilschutz-DTCs; ++DAQ-SPI; --B1-Muster DAQ-DTCs
// 18.01.2011 mf V0.202 ++DAQ-SPI
// 20.01.2011 mf V0.203 ++status_ews
// 21.01.2011 mf V0.204 ++DTCs Sammel DAQ, SPI DCDC/SLE, EWS
// 24.01.2011 mf V0.205 ++bugfix status_ews, ++hwcal-jobs
// 26.01.2011 mf V0.206 ++Qual-DTCs, bugfix hwcal-jobs
// 25.02.2011 mf V0.207 ++DTCs; cahnge status_elup etc.
// 03.03.2011 mf V0.208 change _status_build_id
// 03.03.2011 mf V0.209 bugifx "removeJob"-Fehlermeldung eliminiert
// 04.03.2011 mf V0.210 +_status_hwcal_lesen
// 14.03.2011 mf V0.211 anpassung hwcal_jobs
// 21.03.2011 mf V0.212 +HVIL-DTCs, + ELUP-DTC
// 28.03.2011 mf V0.213 +DiagJobs (Klassierung, dcdcHistogramm, RLS, CPLD-Version
// 31.03.2011 mf V0.214 +DTCs Inverter, dcdc, DAQ, HVIL angepasst
// 01.04.2011 mf V0.215 anpassung _steuern_sn_setzen
// 08.04.2011 mf V0.216 +DTCs sle, Freilaufmodus + job
// 12.04.2011 mf V0.300 Umstieg auf REV3 Board, Entfall von DTCs MC6/MC5
// 28.04.2011 mf V0.301 +DTCsFUSI etc.
// 03.05.2011 mf V0.302 +DTCs PWR, Reset
// 05.05.2011 mf V0.303 bugfix Rotorlagesensor Job
// 12.05.2011 mf V0.304 bugfix Rotorlagesensor Job2
// 19.05.2011 mf V0.305 +DTCs DCDC, AEPH, -AE_SPANNUNG_12V_POWERBOARD
// 24.05.2011 mf V0.306 +DTCs HVSM_ZKU
// 26.05.2011 mf V0.307 +DTCs +Steuern_Aks_Emk - Status_Aks_Emk
// 30.05.2011 mf V0.308 entfernen der Tabellen *_DOP
// 07.06.2011 mf V0.309 +DTCs +status_ctrl_lesen
// 20.06.2011 mf V0.310 bugfix rotorlagesensoranlernen; DTCs vom B1-Muster rausgeworfen
// 27.06.2011 mf V0.311 +/- HVSM-DTCs, +HWCAL-DTCs, +QualUeberwachung-DTCs
// 06.07.2011 mf V0.312 change Parksperre_Anlernen (steuern, status)
// 13.07.2011 mf V0.313 Entschlackung DTCs, new Jobs bzgl. Lebensdauer/BandendeTests
// 18.07.2011 mf V0.314 +DTCs Parksperre FUSI Infospeicher
// 26.07.2011 mf V0.315 Erweiterung Job Rotorlagesensor_Anlernen 0x03
// 01.08.2011 mf V0.500 Branch von 82e -> i01
// 21.09.2011 mf V0.501 ++REX_ON_OFF
// 28.09.2011 mf V0.502 ++ HVPM-Jobs, ++DTCs EME_ELUP
// 11.10.2011 mf V0.503 bugfix STATUS_EWS
// 17.10.2011 mf V0.504 +FA-CAN Diagnosen
// 25.10.2011 mf V0.505 +HVPM-DTCs
// 26.10.2011 mf V0.506 +FIS_PWR_UDQ_CHECK
// 15.11.2011 mf V0.507 --Umrichter-Jobs, --Crash-Jobs, --einige Kom-Dtcs
// 16.11.2011 mf V0.508 ++FIS_EM_T2_THRSHLD, FIS_EM_T2_RANGE_H, FIS_EM_T2_RANGE_L
// 09.12.2011 mf V0.509 ++FIS_HVPM..., FIS_HVSM...
// 14.12.2011 mf V0.510 ++C0 Fise DAQ
// 16.01.2012 mf V0.511 ++FIS_FACAN
// 17.01.2012 mf V0.512 ++Status_fahrstufe
// 02.02.2012 mt V0.513 ++DTCs Notlaufkonzept, --Histogramm-Jobs
// 02.02.2012 mt V0.514 ++ HVPM-Jobs, DCDC_Ansteuerung, System_ON_OFF, Spannungsfreiheit
// 21.02.2012 mt V0.515 bugfix DIAGJobs; SLE_LEISTUNG; SLE_SPANNUNG; BETRIEBSZUSTAND_SLE; CONNECTED_DRIVE
// 01.03.2012 mt V0.516 Bugfix DiagJobs; SLE, CONNECTED DRIVE, TSR LADEN
// 06.03.2012 mt V0.517 ++ HVPM-Job, LSC_LADEN
// 12.03.2012 mt V0.518 Bufix EWS_STATUS
// *******************************************************************
// *******************************************************************
// Konstanten
// *******************************************************************
#pragma best2_type ( win32 )
// Eigene SG-Adresse (Target-Address)
unsigned char TA = 0x1A;
// Anzahl der Argumente f<>r JOB STATUS_LESEN
unsigned char MAX_ARGUMENT_STATUS_LESEN = 5;
// Anzahl der Argumente f<>r JOB STATUS_BLOCK_LESEN
unsigned char MAX_ARGUMENT_STATUS_BLOCK_LESEN = 5;
// Keine Laengenueberpruefung
unsigned int UNCHECK_LEN_IDENTIFIER_LIST[] = {0};
// *******************************************************************
// Includes f<>r Job-Tabellen
// *******************************************************************
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\Tabellen.UDS"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Standardtabellen Unified Diagnostic Services (UDS) nach ISO 14229
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 22.03.2005 gh V0.001 Erstellung
// 28.07.2005 gh V0.002 Entfernung UDS_DID: Tabelle DataIdentifier
// 18.11.2005 gr V0.003 Anpassungen Dateinamen; Erweiterungen fuer SVK
// 18.11.2005 gr V0.003 BMW_PARA, BMW_AUTH entfernt
// 28.11.2005 rd V0.005 UDS_PARAMETER hinzu
// 08.12.2005 tm V0.005 UDS_TAB_FKLASSE hinzu
// 02.02.2006 gr V0.006 UDS_TAB_FKLASSE entfernt
// 02.02.2006 gr V0.006 STD_DIGI ersetzt UDS_TAB_DIGITAL_ARGUMENT
// 02.02.2006 gh V0.006 Include-Name ge<67>ndert (wie Tabellen-Name)
// 28.06.2006 gh V0.007 UDS_TAB_Fehlerklasse hinzu
// *******************************************************************
// TABELLEN.UDS @(#)@ V0.007 @(#)@
// *******************************************************************
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_PARAMETER.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Globale Variable : PARAMETER_BMW_FAST, PARAMETER_BMW_KWP2000
// PARAMETER_DS2, PARAMETER_KWP2000_STERN
// AWLEN_BMW_FAST, AWLEN_BMW_KWP2000
// AWLEN_DS2, AWLEN_KWP2000_STERN
// -------------------------------------------------------------------
// Globale Tabelle : KONZEPT_TABELLE
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 28.11.2005 rd V0.01 Erstellung
// 08.08.2006 rd V0.02 BMW-KWP2000-CAN Timeout und TP-Layer angepasst
// *******************************************************************
// UDS_PARAMETER.B2S @(#)@ V0.02 @(#)@
// *******************************************************************
#define INCLUDE_UDS_PARAMETER_B2S_NOT_FOUND
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_CONSTANTS.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 28.11.2005 rd V0.01 Erstellung
// 08.08.2006 rd V0.02 REPAET_COUNTER von 2 auf 1 reduziert
// rd V0.02 wegen Einsatz parallele Diagnose am D-CAN
// *******************************************************************
// UDS_CONSTANTS.B2S @(#)@ V0.02 @(#)@
// *******************************************************************
#define INCLUDE_UDS_CONSTANTS_B2S_NOT_FOUND
#define REPEAT_COUNTER 1
#define TRUE 1
#define FALSE 0
// ISO14229-1.2 Source Address Type: unsigned char Range 0x00-0xFF
#define SA 0xF1
// ISO14229-1.2 Type: enumeration Range: physical, functional
#define TA_TYPE_PHYSICAL 0x00
#define TA_TYPE_FUNCTIONAL 0x01
// end of : #include "UDS_CONSTANTS.B2S"
// ---------------- Ueberpruefung ob Tabellen includiert sind --------
INCLUDE_UDS_CONSTANTS_B2S_NOT_FOUND
int AWLEN_BMW_KWP2000_CAN[] = {0, 0};
long PARAMETER_BMW_KWP2000_CAN[] = {
0x110, // Konzept
500000, // Baudrate
1000, // Timeout receive FC after FF / CF Bs
0, // Tmin send FC after FF / CF Br
0, // Tmin send CF after FC Cs
1000, // Timeout receive CF after FC Cr
1000, // Timeout receive CF after CF Dr
1200, // Timeout receive response P2max
0, // Tmin send request P3min
5000, // Timeout receive response after $78
2, // Maximum number of negative response $78
1000, // Timeout receive FC after FC.wait Es
0, // Tmin send FC.wait Er
10, // Maximum number of wait frames
0, // ST min send StminUsedByInterface
0, // ST min Handling
// 0: 'disabled' (ST min from ECU FC)
// 1: 'enabled' (StminUsedByInterface)
0, // Tester Present time TimeTesterPresent in ms
// 0: 'disabled'
0, // Tester Present length LenTesterPresent maximum 11
// 0: 'disabled'
// Tester Present message TesterPresentMessage 11 Bytes
// unused bytes 0x00
0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,
1 // Tester Present wait for response
// 0: 'disabled'
// 1: 'enabled'
};
// end of : #include "UDS_PARAMETER.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_TAB_JobResult.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'Statusbyte <-> Statustext'
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// -------------------------------------------------------------------
// History:
// 18.11.2005 rd V0.001 Ersterstellung
// 14.12.2005 gr V0.002 Erweiterung f<>r Standard-Jobs FS_LESEN_DETAIL, SVK_LESEN
// 17.02.2006 gh V0.003 Erweiterung f<>r Standard-Jobs IS_LESEN_DETAIL
// 31.05.2006 rd V0.004 Erweiterung f<>r Standard-Jobs
// V0.004 STEUERN, STEUERN_IO, STEUERN_ROUTINE
// V0.004 STATUS_LESEN
// 21.06.2006 rd V0.005 Erweiterung f<>r Standard-Job STATUS_BLOCK_LESEN
// 19.01.2009 gr V0.006 Erweiterung der JobResult um die Antwort 0x25 ERROR_ECU_NO_RESPONSE_FROM_SUBNET_COMPONENT
// 20.01.2009 gr V0.007 Erweiterung der JobResult um die Antwort 0x26 ERROR_ECU_FAILURE_PREVENTS_EXECUTION_OF_REQUESTED_ACTION
// *******************************************************************
// UDS_TAB_JOBRESULT.B2S @(#)@ V0.007 @(#)@
// *******************************************************************
#define INCLUDE_UDS_TAB_JOBRESULT_B2S_NOT_FOUND
table JobResult[2][] = {
{ "SB" , "STATUS_TEXT" },
// Standard SG Fehlermeldungen
{ "0x10" , "ERROR_ECU_GENERAL_REJECT" },
{ "0x11" , "ERROR_ECU_SERVICE_NOT_SUPPORTED" },
{ "0x12" , "ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED" },
{ "0x13" , "ERROR_ECU_INCORRECT_MESSAGE_LENGTH_OR_INVALID_FORMAT" },
{ "0x14" , "ERROR_ECU_RESPONSE_TOO_LONG" },
{ "0x21" , "ERROR_ECU_BUSY_REPEAT_REQUEST" },
{ "0x22" , "ERROR_ECU_CONDITIONS_NOT_CORRECT" },
{ "0x24" , "ERROR_ECU_REQUEST_SEQUENCE_ERROR" },
{ "0x25" , "ERROR_ECU_NO_RESPONSE_FROM_SUBNET_COMPONENT" },
{ "0x26" , "ERROR_ECU_FAILURE_PREVENTS_EXECUTION_OF_REQUESTED_ACTION"},
{ "0x31" , "ERROR_ECU_REQUEST_OUT_OF_RANGE" },
{ "0x33" , "ERROR_ECU_SECURITY_ACCESS_DENIED" },
{ "0x35" , "ERROR_ECU_INVALID_KEY" },
{ "0x36" , "ERROR_ECU_EXCEED_NUMBER_OF_ATTEMPTS" },
{ "0x37" , "ERROR_ECU_REQUIRED_TIME_DELAY_NOT_EXPIRED" },
{ "0x70" , "ERROR_ECU_UPLOAD_DOWNLOAD_NOT_ACCEPTED" },
{ "0x71" , "ERROR_ECU_TRANSFER_DATA_SUSPENDED" },
{ "0x72" , "ERROR_ECU_GENERAL_PROGRAMMING_FAILURE" },
{ "0x73" , "ERROR_ECU_WRONG_BLOCK_SEQUENCE_COUNTER" },
{ "0x78" , "ERROR_ECU_REQUEST_CORRECTLY_RECEIVED__RESPONSE_PENDING" },
{ "0x7E" , "ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED_IN_ACTIVE_SESSION" },
{ "0x7F" , "ERROR_ECU_SERVICE_NOT_SUPPORTED_IN_ACTIVE_SESSION" },
{ "0x81" , "ERROR_ECU_RPM_TOO_HIGH" },
{ "0x82" , "ERROR_ECU_RPM_TOO_LOW" },
{ "0x83" , "ERROR_ECU_ENGINE_IS_RUNNING" },
{ "0x84" , "ERROR_ECU_ENGINE_IS_NOT_RUNNING" },
{ "0x85" , "ERROR_ECU_ENGINE_RUN_TIME_TOO_LOW" },
{ "0x86" , "ERROR_ECU_TEMPERATURE_TOO_HIGH" },
{ "0x87" , "ERROR_ECU_TEMPERATURE_TOO_LOW" },
{ "0x88" , "ERROR_ECU_VEHICLE_SPEED_TOO_HIGH" },
{ "0x89" , "ERROR_ECU_VEHICLE_SPEED_TOO_LOW" },
{ "0x8A" , "ERROR_ECU_THROTTLE_PEDAL_TOO_HIGH" },
{ "0x8B" , "ERROR_ECU_THROTTLE_PEDAL_TOO_LOW" },
{ "0x8C" , "ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_NEUTRAL" },
{ "0x8D" , "ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_GEAR" },
{ "0x8F" , "ERROR_ECU_BRAKE_SWITCH_NOT_CLOSED" },
{ "0x90" , "ERROR_ECU_SHIFTER_LEVER_NOT_IN_PARK" },
{ "0x91" , "ERROR_ECU_TORQUE_CONVERTER_CLUTCH_LOCKED" },
{ "0x92" , "ERROR_ECU_VOLTAGE_TOO_HIGH" },
{ "0x93" , "ERROR_ECU_VOLTAGE_TOO_LOW" },
// Standard JOB Okaymeldung
{ "?00?" , "OKAY" },
// Standard JOB Fehlermeldungen
{ "?01?" , "ERROR_ECU_NO_RESPONSE" },
{ "?02?" , "ERROR_ECU_INCORRECT_LEN" },
{ "?03?" , "ERROR_ECU_INCORRECT_RESPONSE_ID" },
{ "?04?" , "ERROR_ECU_TA_RESPONSE_NOT_SA_REQUEST" },
{ "?05?" , "ERROR_ECU_SA_RESPONSE_NOT_TA_REQUEST" },
{ "?06?" , "ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER" },
{ "?07?" , "ERROR_ECU_RESPONSE_TOO_MUCH_DATA" },
{ "?08?" , "ERROR_ECU_RESPONSE_TOO_LESS_DATA" },
{ "?09?" , "ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE" },
{ "?0A?" , "ERROR_TABLE" },
{ "?10?" , "ERROR_F_CODE" },
{ "?12?" , "ERROR_INTERPRETATION" },
{ "?13?" , "ERROR_F_POS" },
{ "?14?" , "ERROR_ECU_RESPONSE_INCORRECT_IO_CONTROL_PARAMETER" },
{ "?15?" , "ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_TYPE" },
{ "?16?" , "ERROR_ECU_RESPONSE_INCORRECT_SUB_FUNCTION" },
{ "?17?" , "ERROR_ECU_RESPONSE_INCORRECT_DYNAMICALLY_DEFINED_DATA_IDENTIFIER"},
{ "?18?" , "ERROR_ECU_RESPONSE_NO_STRING_END_CHAR" },
// Fehlermeldung bei Standard Job PRUEFSTEMPEL_SCHREIBEN
{ "?50?" , "ERROR_BYTE1" },
{ "?51?" , "ERROR_BYTE2" },
{ "?52?" , "ERROR_BYTE3" },
// Fehlermeldung bei Standard Job SVK_LESEN
{ "?80?" , "ERROR_SVK_INCORRECT_LEN" },
{ "?81?" , "ERROR_SVK_INCORRECT_FINGERPRINT" },
// Fehlermeldung bei sonstigen Standard-Jobs
{ "?F0?" , "ERROR_ARGUMENT" },
// keine gueltige Antwort
{ "0xXY" , "ERROR_ECU_UNKNOWN_NEGATIVE_RESPONSE" }
};
// end of : #include "UDS_TAB_JobResult.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_TAB_Lieferanten.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'Lieferantennummer <-> Lieferantentext'
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 18.11.2005 gr V0.001 Ersterstellung auf Basis STD_LIEF.B2S
// 13.12.2005 rd V0.002 0x76 neu hinzu
// 02.02.2006 gh V0.003 Include-Name ge<67>ndert (wie Tabellen-Name)
// 27.06.2006 rd V0.004 0x77 bis 0x80 neu hinzu
// 14.09.2006 rd V0.005 0x81 bis 0x84 neu hinzu
// 23.10.2006 rd V0.006 0x85 neu hinzu
// 15.11.2006 rd V0.007 0x86 bis 0x88 neu hinzu
// 24.11.2006 rd V1.000 0x000072 Rechtschreibfehler behoben
// V1.000 Freigabe
// 31.01.2007 rd V1.001 0x89 neu hinzu
// 02.02.2007 rd V1.002 0x90 neu hinzu
// 19.02.2007 rd V1.003 0x91, 0x92 neu hinzu
// 13.03.2007 rd V1.004 0x93 neu hinzu
// 14.03.2007 rd V1.005 0x94 - 0x96 neu hinzu
// 18.06.2007 rd V1.006 0x97 - 0x99 neu hinzu
// 22.11.2007 rd V1.007 0x9A - 0x9E neu hinzu
// 03.12.2007 as V1.008 0x9F neu hinzu
// 25.01.2008 rd V1.009 0xA0 neu hinzu
// 07.02.2008 rd V1.010 0xA1 neu hinzu
// 04.06.2008 rd V1.029 A2,A3 neu hinzu
// 17.06.2008 rd V1.030 A4 neu hinzu
// 21.10.2008 rd V1.031 A5 neu hinzu
// 17.11.2008 rd V1.032 A6, A7 neu hinzu
// 04.12.2008 rd V1.033 A8 neu hinzu
// 17.02.2009 rd V1.034 A9 neu hinzu
// 30.07.2009 rd V1.035 AA, AB neu hinzu
// 29.04.2010 rd V1.036 AC-AE neu hinzu
// 01.03.2011 rd V1.037 AF neu hinzu
// 02.03.2011 rd V1.038 B0 neu hinzu
// 02.05.2011 rd V1.039 B1, B2 neu hinzu
// 30.11.2011 rd V1.040 B3 neu hinzu
// 25.01.2012 rd V1.041 B4 neu hinzu
// *******************************************************************
// UDS_TAB_Lieferanten.B2S @(#)@ V1.041@(#)@
// *******************************************************************
#define INCLUDE_UDS_Lieferanten_B2S_NOT_FOUND
table Lieferanten[2][] = {
{ "LIEF_NR" , "LIEF_TEXT" },
{ "0x000001" , "Reinshagen => Delphi" },
{ "0x000002" , "Kostal" },
{ "0x000003" , "Hella" },
{ "0x000004" , "Siemens" },
{ "0x000005" , "Eaton" },
{ "0x000006" , "UTA" },
{ "0x000007" , "Helbako" },
{ "0x000008" , "Bosch" },
{ "0x000009" , "Loewe => Lear" },
{ "0x000010" , "VDO" },
{ "0x000011" , "Valeo" },
{ "0x000012" , "MBB" },
{ "0x000013" , "Kammerer" },
{ "0x000014" , "SWF" },
{ "0x000015" , "Blaupunkt" },
{ "0x000016" , "Philips" },
{ "0x000017" , "Alpine" },
{ "0x000018" , "Continental Teves" },
{ "0x000019" , "Elektromatik Suedafrika" },
{ "0x000020" , "Becker" },
{ "0x000021" , "Preh" },
{ "0x000022" , "Alps" },
{ "0x000023" , "Motorola" },
{ "0x000024" , "Temic" },
{ "0x000025" , "Webasto" },
{ "0x000026" , "MotoMeter" },
{ "0x000027" , "Delphi PHI" },
{ "0x000028" , "DODUCO => BERU" },
{ "0x000029" , "DENSO" },
{ "0x000030" , "NEC" },
{ "0x000031" , "DASA" },
{ "0x000032" , "Pioneer" },
{ "0x000033" , "Jatco" },
{ "0x000034" , "Fuba" },
{ "0x000035" , "UK-NSI" },
{ "0x000036" , "AABG" },
{ "0x000037" , "Dunlop" },
{ "0x000038" , "Sachs" },
{ "0x000039" , "ITT" },
{ "0x000040" , "FTE" },
{ "0x000041" , "Megamos" },
{ "0x000042" , "TRW" },
{ "0x000043" , "Wabco" },
{ "0x000044" , "ISAD Electronic Systems" },
{ "0x000045" , "HEC (Hella Electronics Corporation)" },
{ "0x000046" , "Gemel" },
{ "0x000047" , "ZF" },
{ "0x000048" , "GMPT" },
{ "0x000049" , "Harman Kardon" },
{ "0x000050" , "Remes" },
{ "0x000051" , "ZF Lenksysteme" },
{ "0x000052" , "Magneti Marelli" },
{ "0x000053" , "Borg Instruments" },
{ "0x000054" , "GETRAG" },
{ "0x000055" , "BHTC (Behr Hella Thermocontrol)" },
{ "0x000056" , "Siemens VDO Automotive" },
{ "0x000057" , "Visteon" },
{ "0x000058" , "Autoliv" },
{ "0x000059" , "Haberl" },
{ "0x000060" , "Magna Steyr" },
{ "0x000061" , "Marquardt" },
{ "0x000062" , "AB-Elektronik" },
{ "0x000063" , "Siemens VDO Borg" },
{ "0x000064" , "Hirschmann Electronics" },
{ "0x000065" , "Hoerbiger Electronics" },
{ "0x000066" , "Thyssen Krupp Automotive Mechatronics"},
{ "0x000067" , "Gentex GmbH" },
{ "0x000068" , "Atena GmbH" },
{ "0x000069" , "Magna-Donelly" },
{ "0x000070" , "Koyo Steering Europe" },
{ "0x000071" , "NSI B.V" },
{ "0x000072" , "AISIN AW CO.LTD" },
{ "0x000073" , "Shorlock" },
{ "0x000074" , "Schrader" },
{ "0x000075" , "BERU Electronics GmbH" },
{ "0x000076" , "CEL" },
{ "0x000077" , "Audio Mobil" },
{ "0x000078" , "rd electronic" },
{ "0x000079" , "iSYS RTS GmbH" },
{ "0x000080" , "Westfalia Automotive GmbH" },
{ "0x000081" , "Tyco Electronics" },
{ "0x000082" , "Paragon AG" },
{ "0x000083" , "IEE S.A" },
{ "0x000084" , "TEMIC AUTOMOTIVE of NA" },
{ "0x000085" , "AKsys GmbH" },
{ "0x000086" , "META System" },
{ "0x000087" , "H<>lsbeck & F<>rst GmbH & Co KG" },
{ "0x000088" , "Mann & Hummel Automotive GmbH" },
{ "0x000089" , "Brose Fahrzeugteile GmbH & Co" },
{ "0x000090" , "Keihin" },
{ "0x000091" , "Vimercati S.p.A." },
{ "0x000092" , "CRH" },
{ "0x000093" , "TPO Display Corp." },
{ "0x000094" , "K<>STER Automotive Control" },
{ "0x000095" , "Hitachi Automotive" },
{ "0x000096" , "Continental Automotive" },
{ "0x000097" , "TI-Automotive" },
{ "0x000098" , "Hydro" },
{ "0x000099" , "Johnson Controls" },
{ "0x00009A" , "Takata- Petri" },
{ "0x00009B" , "Mitsubishi Electric B.V. (Melco)" },
{ "0x00009C" , "Autokabel" },
{ "0x00009D" , "GKN-Driveline" },
{ "0x00009E" , "Zollner Elektronik AG" },
{ "0x00009F" , "PEIKER acustics GmbH" },
{ "0x0000A0" , "Bosal-Oris" },
{ "0x0000A1" , "Cobasys" },
{ "0x0000A2" , "Lighting Reutlingen GmbH" },
{ "0x0000A3" , "CONTI VDO" },
{ "0x0000A4" , "ADC Automotive Distance Control Systems GmbH"},
{ "0x0000A5" , "Funkwerk Dabendorf GmbH" },
{ "0x0000A6" , "Lame" },
{ "0x0000A7" , "Magna/Closures" },
{ "0x0000A8" , "Wanyu" },
{ "0x0000A9" , "Thyssen Krupp Presta" },
{ "0x0000AA" , "ArvinMeritor" },
{ "0x0000AB" , "Kongsberg Automotive GmbH" },
{ "0x0000AC" , "SMR Automotive Mirrors" },
{ "0x0000AD" , "So.Ge.Mi." },
{ "0x0000AE" , "MTA" },
{ "0x0000AF" , "Alfmeier" },
{ "0x0000B0" , "ELTEK VALERE DEUTSCHLAND GMBH" },
{ "0x0000B1" , "Omron Automotive Electronics Europe Group" },
{ "0x0000B2" , "ASK" },
{ "0x0000B3" , "CML Innovative Technologies GmbH & Co. KG" },
{ "0x0000B4" , "APAG Elektronik AG" },
{ "0xFFFFFF" , "unbekannter Hersteller" }
};
// end of : #include "UDS_TAB_Lieferanten.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_TAB_FArtTexte.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'Fehlerart-Nr -> Fehlerart-Text'
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 18.11.2005 gr V0.001 Ersterstellung aus Basis STD_FART.B2S
// 20.12.2005 gr V0.002 Anpassung Text bei 0x00
// 02.02.2006 gr V0.003 Anpassungen an neue DTCStatusMask 0C
// 02.02.2006 gr V0.003 Include-Name ge<67>ndert (wie Tabellen-Name)
// 06.08.2007 tm V0.004 Texte ge<67>ndert
// 05.05.2009 gr V0.005 0x40 "unbekannte Fehlerart" f<>r VP-Prozess hinzu
// *******************************************************************
// UDS_TAB_FArtTexte.B2S @(#)@ V0.005 @(#)@
// *******************************************************************
#define INCLUDE_UDS_TAB_FArtTexte_B2S_NOT_FOUND
table FArtTexte[2][] = {
{ "ARTNR" , "ARTTEXT" },
{ "0x00" , "keine Fehlerart verf<72>gbar" },
{ "0x04" , "Fehler momentan nicht vorhanden, aber bereits gespeichert" },
{ "0x05" , "Fehler momentan vorhanden und bereits gespeichert" },
{ "0x08" , "Fehler momentan nicht vorhanden, aber bereits gespeichert" },
{ "0x09" , "Fehler momentan vorhanden und bereits gespeichert" },
{ "0x0C" , "Fehler momentan nicht vorhanden, aber bereits gespeichert" },
{ "0x0D" , "Fehler momentan vorhanden und bereits gespeichert" },
{ "0x40" , "unbekannte Fehlerart" },
{ "0x44" , "Fehler gespeichert" },
{ "0x45" , "Fehler gespeichert" },
{ "0x48" , "Fehler gespeichert" },
{ "0x49" , "Fehler gespeichert" },
{ "0x4C" , "Fehler gespeichert" },
{ "0x4D" , "Fehler gespeichert" },
{ "0x10" , "Testbedingungen erf<72>llt" },
{ "0x11" , "Testbedingungen noch nicht erf<72>llt" },
{ "0x80" , "Fehler w<>rde kein Aufleuchten einer Warnlampe verursachen" },
{ "0x81" , "Fehler w<>rde das Aufleuchten einer Warnlampe verursachen" },
{ "0xFF" , "unbekannte Fehlerart" }
};
// end of : #include "UDS_TAB_FArtTexte.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\STD_DIGI.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'Text Digitalargument <-> Wert Digitalargument'
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 6
// Lastenheft Programmieren Programm/Daten 7 500 334 F
// -------------------------------------------------------------------
// History:
// 24.04.2002 gh V1.00 Namens<6E>nderung (Ursprung: BMW_DIGI.b2s)
// 22.04.2003 rd V1.01 Versionskennung hinzu
// 26.04.2004 rd V1.02 'an' neu hinzu
// *******************************************************************
// STD_DIGI.B2S @(#)@ V1.02 @(#)@
// *******************************************************************
#define INCLUDE_STD_DIGI_B2S_NOT_FOUND
table DigitalArgument[2][] = {
{ "TEXT" , "WERT" },
{ "ein" , "1" },
{ "aus" , "0" },
{ "ja" , "1" },
{ "nein" , "0" },
{ "auf" , "1" },
{ "ab" , "0" },
{ "an" , "1" },
{ "yes" , "1" },
{ "no" , "0" },
{ "on" , "1" },
{ "off" , "0" },
{ "up" , "1" },
{ "down" , "0" },
{ "true" , "1" },
{ "false" , "0" },
{ "1" , "1" },
{ "0" , "0" }
};
// end of : #include "STD_DIGI.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_TAB_Prozessklassen.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VERAENDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'Prozessklasse WERT <-> Prozessklasse BEZEICHNUNG'
// -------------------------------------------------------------------
// History:
// 14.11.2005 gr V0.001 Ersterstellung
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Tabellen-Name)
// 22.03.2007 gh V0.003 Prozessklassen ge<67>ndert (teilweise INKOMPATIBEL !!!)
// 01.02.2008 gr V0.004 Prozessklassen SWUP,SWIP, BLUP und FLUP hinzu
// 25.06.2011 gh V0.005 Prozessklasse wegen BDC hinzu: 0x04, GWTB
// ***************************************************************************
// UDS_TAB_Prozessklassen.B2S @(#)@ V0.005 @(#)@
// ***************************************************************************
#define INCLUDE_UDS_TAB_Prozessklassen_B2S_NOT_FOUND
table Prozessklassen[3][] = {
{ "WERT" , "PROZESSKLASSE" , "BEZEICHNUNG" },
{ "0x00" , "-" , "ungueltig" },
// nachfolgende Eintr<74>ge blieben gleich (V0.002 => V.0.003)
{ "0x01" , "HWEL" , "Hardware (Elektronik)" },
{ "0x02" , "HWAP" , "Hardwareauspraegung" },
{ "0x03" , "HWFR" , "Hardwarefarbe" },
{ "0x05" , "CAFD" , "Codierdaten" },
{ "0x06" , "BTLD" , "Bootloader" },
{ "0x08" , "SWFL" , "Software ECU Speicherimage" },
{ "0x09" , "SWFF" , "Flash File Software" },
{ "0x0A" , "SWPF" , "Pruefsoftware" },
{ "0x0B" , "ONPS" , "Onboard Programmiersystem" },
{ "0x0F" , "FAFP" , "FA2FP" },
{ "0x1A" , "TLRT" , "Temporaere Loeschroutine" },
{ "0x1B" , "TPRG" , "Temporaere Programmierroutine" },
// nachfolgende Eintr<74>ge kamen neu dazu (V0.002 => V.0.003)
{ "0x07" , "FLSL" , "Flashloader Slave" },
{ "0x0C" , "IBAD" , "Interaktive Betriebsanleitung Daten" },
{ "0x10" , "FCFA" , "Freischaltcode Fahrzeug-Auftrag" },
{ "0x1C" , "BLUP" , "Bootloader-Update Applikation" },
{ "0x1D" , "FLUP" , "Flashloader-Update Applikation" },
// nachfolgende Eintr<74>ge kamen neu dazu (V0.004 => V.0.005)
{ "0x04" , "GWTB" , "Gateway-Tabelle" },
// nachfolgende Eintr<74>ge wurden INKOMPATIBEL ge<67>ndert !
// bei V0.002 (alt)
//{ "0xA0" , "VEHI" , "Vehicle Info Spec" },
//{ "0xA1" , "COMS" , "Comparam Spec" },
//{ "0xA2" , "DIAG" , "Diag-Layer Container" },
//{ "0xA3" , "FLCU" , "Flash Datei" },
//{ "0xA4" , "JAJO" , "Java-Jobs" },
// bei V.0.003 (neu)
{ "0xA0" , "ENTD" , "Entertainment Daten" },
{ "0xA1" , "NAVD" , "Navigation Daten" },
{ "0xA2" , "FCFN" , "Freischaltcode Funktion" },
{ "0xC0" , "SWUP" , "Software-Update Package" },
{ "0xC1" , "SWIP" , "Index Software-Update Package" },
{ "0xFF" , "-" , "ungueltig" }
};
// end of : #include "UDS_TAB_Prozessklassen.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_TAB_SVK_ID.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VERAENDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'SVK ID <-> SVK Bezeichnung'
// -------------------------------------------------------------------
// History:
// 14.11.2005 gr V0.001 Ersterstellung
// 01.02.2006 gr V0.002 Tabelle um SVK_BACKUP erweitert
// ***************************************************************************
// UDS_TAB_SVK_ID.B2S @(#)@ V0.002 @(#)@
// ***************************************************************************
#define INCLUDE_UDS_TAB_SVK_ID_B2S_NOT_FOUND
table SVK_ID[2][] = {
{ "WERT" , "BEZEICHNUNG" },
{ "0x01" , "SVK_AKTUELL" },
{ "0x02" , "SVK_SUPPLIER" },
{ "0x03" , "SVK_WERK" },
{ "0x04" , "SVK_BACKUP_01" },
{ "0x05" , "SVK_BACKUP_02" },
{ "0x06" , "SVK_BACKUP_03" },
{ "0x07" , "SVK_BACKUP_04" },
{ "0x08" , "SVK_BACKUP_05" },
{ "0x09" , "SVK_BACKUP_06" },
{ "0x0A" , "SVK_BACKUP_07" },
{ "0x0B" , "SVK_BACKUP_08" },
{ "0x0C" , "SVK_BACKUP_09" },
{ "0x0D" , "SVK_BACKUP_10" },
{ "0x0E" , "SVK_BACKUP_11" },
{ "0x0F" , "SVK_BACKUP_12" },
{ "0x10" , "SVK_BACKUP_13" },
{ "0x11" , "SVK_BACKUP_14" },
{ "0x12" , "SVK_BACKUP_15" },
{ "0x13" , "SVK_BACKUP_16" },
{ "0x14" , "SVK_BACKUP_17" },
{ "0x15" , "SVK_BACKUP_18" },
{ "0x16" , "SVK_BACKUP_19" },
{ "0x17" , "SVK_BACKUP_20" },
{ "0x18" , "SVK_BACKUP_21" },
{ "0x19" , "SVK_BACKUP_22" },
{ "0x1A" , "SVK_BACKUP_23" },
{ "0x1B" , "SVK_BACKUP_24" },
{ "0x1C" , "SVK_BACKUP_25" },
{ "0x1D" , "SVK_BACKUP_26" },
{ "0x1E" , "SVK_BACKUP_27" },
{ "0x1F" , "SVK_BACKUP_28" },
{ "0x20" , "SVK_BACKUP_29" },
{ "0x21" , "SVK_BACKUP_30" },
{ "0x22" , "SVK_BACKUP_31" },
{ "0x23" , "SVK_BACKUP_32" },
{ "0x24" , "SVK_BACKUP_33" },
{ "0x25" , "SVK_BACKUP_34" },
{ "0x26" , "SVK_BACKUP_35" },
{ "0x27" , "SVK_BACKUP_36" },
{ "0x28" , "SVK_BACKUP_37" },
{ "0x29" , "SVK_BACKUP_38" },
{ "0x2A" , "SVK_BACKUP_39" },
{ "0x2B" , "SVK_BACKUP_40" },
{ "0x2C" , "SVK_BACKUP_41" },
{ "0x2D" , "SVK_BACKUP_42" },
{ "0x2E" , "SVK_BACKUP_43" },
{ "0x2F" , "SVK_BACKUP_44" },
{ "0x30" , "SVK_BACKUP_45" },
{ "0x31" , "SVK_BACKUP_46" },
{ "0x32" , "SVK_BACKUP_47" },
{ "0x33" , "SVK_BACKUP_48" },
{ "0x34" , "SVK_BACKUP_49" },
{ "0x35" , "SVK_BACKUP_50" },
{ "0x36" , "SVK_BACKUP_51" },
{ "0x37" , "SVK_BACKUP_52" },
{ "0x38" , "SVK_BACKUP_53" },
{ "0x39" , "SVK_BACKUP_54" },
{ "0x3A" , "SVK_BACKUP_55" },
{ "0x3B" , "SVK_BACKUP_56" },
{ "0x3C" , "SVK_BACKUP_57" },
{ "0x3D" , "SVK_BACKUP_58" },
{ "0x3E" , "SVK_BACKUP_59" },
{ "0x3F" , "SVK_BACKUP_60" },
{ "0x40" , "SVK_BACKUP_61" },
{ "0xXY" , "ERROR_UNKNOWN" }
};
// end of : #include "UDS_TAB_SVK_ID.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_TAB_DTCExtendedDataRecordNumber.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'Extended Identifier -> Extended Data-Text'
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 08.12.2005 gr V0.001 Ersterstellung
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Tabellen-Name)
// *******************************************************************
// UDS_TAB_DTCExtendedDataRecordNumber.B2S @(#)@ V0.002 @(#)@
// *******************************************************************
#define INCLUDE_UDS_TAB_DTCExtendedDataRecordNumber_B2S_NOT_FOUND
table DTCExtendedDataRecordNumber[3][] = {
{ "WERT" , "TEXT" , "ANZ_BYTE" },
{ "0x00" , "ISO_RESERVED" , "0" },
{ "0x01" , "CONDITION_BYTE" , "1" },
{ "0x02" , "HFK" , "1" },
{ "0x03" , "HLZ" , "1" },
{ "0xFF" , "RECORD_UNKNOWN" , "0" }
};
// end of : #include "UDS_TAB_DTCExtendedDataRecordNumber.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_TAB_DTCSnapshotIdentifier.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'Snapshot Identifier -> Snapshot-Text'
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 08.12.2005 gr V0.001 Ersterstellung
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Tabellen-Name)
// 21.02.2008 gr V0.003 Identifier 1731 hinzu (Anforderung S. Etessam)
// *******************************************************************
// UDS_TAB_DTCSnapshotIdentifier.B2S @(#)@ V0.003 @(#)@
// *******************************************************************
#define INCLUDE_UDS_TAB_DTCSnapshotIdentifier_B2S_NOT_FOUND
table DTCSnapshotIdentifier[9][] = {
{ "UWNR" , "UWTEXT" , "UW_EINH" , "L/H" , "UWTYP" , "NAME" , "MUL" , "DIV" , "ADD" },
{ "0x1700" , "KM_STAND" , "0-n" , "-" , "0xFFFFFF" , "-" , "1" , "1" , "0.000000" },
{ "0x1701" , "ABS_ZEIT" , "0-n" , "-" , "0xFFFFFFFF" , "-" , "1" , "1" , "0.000000" },
{ "0x1702" , "SAE_CODE" , "0-n" , "-" , "0xFFFFFF" , "-" , "1" , "1" , "0.000000" },
{ "0x1731" , "Fehlerklasse_DTC" , "-" , "-" , "u char" , "-" , "1" , "1" , "0.000000" },
{ "0xFFFF" , "IDENTIFIER_UNKNOWN" , "-" , "-" , "0xFFFFFF" , "-" , "1" , "1" , "0.000000" }
};
// end of : #include "UDS_TAB_DTCSnapshotIdentifier.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_TAB_Fehlerklasse.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'Fehlerklasse-Nr -> Fehlerklasse-Text'
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 05.12.2005 gr V0.001 Ersterstellung
// 23.06.2006 gh V0.002 Include-Name ge<67>ndert (wie Tabellen-Name)
// *******************************************************************
// UDS_TAB_Fehlerklasse.B2S @(#)@ V0.002 @(#)@
// *******************************************************************
#define INCLUDE_UDS_TAB_Fehlerklasse_B2S_NOT_FOUND
table Fehlerklasse[2][] = {
{ "NR" , "TEXT" },
{ "0x00" , "Keine Fehlerklasse verfuegbar" },
{ "0x01" , "Ueberpruefung bei naechstem Werkstattbesuch" },
{ "0x02" , "Ueberpruefung bei naechstem Halt" },
{ "0x04" , "Ueberpruefung sofort erforderlich !" },
{ "0xFF" , "unbekannte Fehlerklasse" }
};
// end of : #include "UDS_TAB_Fehlerklasse.B2S"
// end of : #include "Tabellen.UDS"
// UDS Standard Tabelle (f<>r Job Diagnose_Mode)
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_TAB_DiagMode.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Tabelle: DiagnosticMode
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// -------------------------------------------------------------------
// History:
// 16.12.2005 gr V0.001 Ersterstellung
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Tabellen-Name)
// 22.02.2006 gh V0.003 Korrektur: 0x03 = ECUExtendedDiagnosticSession
// 22.06.2006 gh V0.004 Integration weiterer Diagnose-Modi
// 20.01.2009 gr V0.005 Integration Diagnose-Modi 0x04 und 0x43
// *******************************************************************
// UDS_DiagMode.B2S @(#)@ V0.005 @(#)@
// *******************************************************************
#define INCLUDE_UDS_TAB_DiagMode_B2S_NOT_FOUND
table DiagMode[3][] = {
{ "NR" , "MODE" , "MODE_TEXT" },
{ "0x00" , "UNGUELTIG" , "DefaultMode" },
{ "0x01" , "DEFAULT" , "DefaultMode" },
{ "0x02" , "ECUPM" , "ECUProgrammingMode" },
{ "0x03" , "ECUEXTDIAG" , "ECUExtendedDiagnosticSession" },
{ "0x04" , "ECUSSDS" , "ECUSafetySystemDiagnosticSession" },
{ "0x40" , "ECUEOL" , "ECUEndOfLineSession" },
{ "0x41" , "ECUCODE" , "ECUCodingSession" },
{ "0x42" , "ECUSWT" , "ECUSwtSession" },
{ "0x43" , "ECUHDD" , "ECUHDDDownloadSession" },
{ "0x4F" , "ECUDEVELOP" , "ECUDevelopmentSession" },
{ "0xXY" , "--" , "unbekannter Diagnose-Mode" }
};
// end of : #include "UDS_TAB_DiagMode.B2S"
// UDS Standard Tabelle (f<>r Job Sensoren_Ident_Lesen)
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\STD_ISEN.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VERAENDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'Verbauortnr <-> Verbauorttext'
// -------------------------------------------------------------------
// Gueltig:
// Lastenheft Diagnose Ausgabe 6
// f<>r $22 ReadDataBydentifier
// $16xx SubbusMemberSerialNumber
// -------------------------------------------------------------------
// History:
// 23.05.2003 rd V0.01 Ersterstellung
// 26.05.2003 rd V0.02 Erweiterung 0x0400, 0x500
// 07.07.2003 rd V0.03 Erweiterung 0x0350
// 22.11.2004 rd V0.04 Erweiterung 0x0600, 0x700
// 30.06.2005 rd V0.05 Erweiterung 0x0800, 0x900
// 20.10.2005 rd V1.00 Erweiterung 0x0A00
// 05.10.2006 rd V1.01 Erweiterung 0x0A00
// V1.01 Sonderbehandlung bei DXC SG-Adresse 0x29
// 23.10.2006 rd V1.02 Erweiterung 0x0B00
// 07.12.2006 rd V1.03 Erweiterung 0x0C00
// 11.01.2007 tm V1.04 Erweiterung 0x0E00
// 15.01.2007 rd V1.05 Erweiterung 0x0F00-0x1300
// 08.02.2007 rd V1.06 Erweiterung 0x1400-0x1E00
// 15.02.2007 gr V1.07 Neue Spalte LIN_2_FORMAT zum Auslesen der zus<75>tlichen Infos
// 29.03.2007 rd V1.08 Erweiterung 0x2000
// 17.04.2007 rd V1.09 Erweiterung 0x2100
// 16.05.2007 rd V1.10 Erweiterung f<>r CAS4
// 25.06.2007 rd V1.11 Erweiterung FRM3, CAS4 Indizes verschoben
// 11.07.2007 rd V1.12 Erweiterung DME F01
// 13.08.2007 rd V1.13 FRM3 Aussenspiegel kein LIN_2_FORMAT
// 14.08.2007 rd V1.14 Sitzverstellschalter dazu
// 17.08.2007 rd V1.15 Sitzheizung ge<67>ndert / neu
// 17.01.2008 gr V1.16 Fond-Klimaanlage hinzu
// 30.01.2008 rd V1.17 Kraftstoffpumpe hinzu
// 13.02.2008 rd V1.18 Gep<65>ckraumschalter vorbereitet
// 20.02.2008 rd V1.19 Spurwechselradarsensor Lin 2 Format
// 25.02.2008 rd V1.20 PMA Sensoren hinzu
// 03.03.2008 rd V1.21 PMA Sensoren kein Lin 2 Format
// V1.21 Spurwechselradarsensor kein Lin 2 Format
// 04.03.2008 rd V1.22 Gep<65>ckraumschalter hinzu
// 07.03.2008 rd V1.23 Startergenerator, <20>lqualit<69>tsensor hinzu
// 17.03.2008 rd V1.24 Topview, Sideview, Rearview Kameras LIN_2_FORMAT
// 18.04.2008 rd V1.25 CID-Klappe dazu
// 05.06.2008 rd V1.26 Erweiterung f<>r F25
// 09.06.2008 rd V1.27 Erweiterung f<>r L7
// 03.07.2008 rd V1.28 Erweiterung f<>r F12
// 01.08.2008 rd V1.29 Erweiterung f<>r ACSM4
// 04.08.2008 rd V1.30 PMA Sensoren jetzt doch wieder Lin 2 Format
// 16.09.2008 rd V1.31 Erweiterung
// 21.10.2008 rd V1.32 Erweiterung
// 13.11.2008 rd V1.33 Erweiterung ELV Lin 2
// 18.11.2008 rd V1.34 Mirkrowellensensoren <20>berarbeitet
// 24.11.2008 rd V1.35 Zusatzwasserpumpe und Generator am Lin neu
// 02.12.2008 rd V1.36 EKK neu
// 16.01.2009 rd V1.37 Wasserpumpen 1 und 2 neu
// 16.02.2009 rd V1.38 ACSM neue Sensoren dazu
// 22.04.2009 rd V1.39 ACSM Sensoren. Jetzt doch nicht LIN 2
// 20.05.2009 rd V1.40 Audio Bedienteil LIN 2
// 08.09.2009 as V1.41 Klimaumf<6D>nge hinzu
// 22.09.2009 rd V1.42 ACSM neue Sensoren dazu
// 07.10.2009 rd V1.43 SMO, PT-Tank dazu
// 13.10.2009 rd V1.44 LED-Module dazu
// 28.10.2009 rd V1.45 EAC-Sensor dazu
// 22.02.2010 rd V1.46 Innenlichtelektronik dazu
// 20.07.2011 rd V1.47 Zentralinstrument dazu
// 23.09.2011 rd V1.48 Nackenw<6E>rmer dazu
// 08.11.2011 rd V1.49 ELSV und HOD dazu
// 15.12.2011 rd V1.50 Standheizung, W<>rmepumpe, Durchlaufheizer dazu
// rd V1.50 BDC Innenbeleuchtung dazu
// 02.02.2012 rd V1.51 Ionisator, Bedufter dazu
// 01.03.2012 rd V1.52 DCDC Versorgung Zustartbatterie dazu
// *******************************************************************
// STD_ISEN.B2S @(#)@ V1.52 @(#)@
// *******************************************************************
#define INCLUDE_STD_ISEN_B2S_NOT_FOUND
// Zuordnung von Verbauort-Nummer zu Verbauort-Text
// intelligenter Sensoren
table VerbauortTabelle[3][] = {
{ "ORT" , "ORTTEXT" , "LIN_2_FORMAT"},
{ "0x0100" , "Batteriesensor BSD" , "-" },
{ "0x0150" , "<22>lqualit<69>tsensor BSD" , "-" },
{ "0x0200" , "Elektrische Wasserpumpe BSD" , "-" },
{ "0x0250" , "Elektrische Kraftstoffpumpe BSD" , "-" },
{ "0x0300" , "Generator 1" , "-" },
{ "0x0350" , "Generator 2" , "-" },
{ "0x03A0" , "Druck- Temperatursensor Tank" , "1" },
{ "0x03C0" , "EAC-Sensor" , "-" },
{ "0x0400" , "Schaltzentrum Lenks<6B>ule" , "-" },
{ "0x0500" , "DSC Sensor-Cluster" , "-" },
{ "0x0600" , "Nahbereichsradarsensor links" , "-" },
{ "0x0700" , "Nahbereichsradarsensor rechts" , "-" },
{ "0x0800" , "Funkempf<70>nger" , "-" },
{ "0x0900" , "Elektrische Lenks<6B>ulenverriegelung" , "-" },
{ "0x0A00" , "Regen- Lichtsensor" , "-" },
{ "0x290A00" , "DSC Hydraulikblock" , "-" }, // Sonderbehandlung
{ "0x0B00" , "Nightvision Kamera" , "-" },
{ "0x0C00" , "TLC Kamera" , "-" },
{ "0x0D00" , "Spurwechselradarsensor hinten links" , "-" },
{ "0x0E00" , "Heckklima Bedienteil rechts" , "1" },
{ "0x0F00" , "Rearview Kamera hinten" , "1" },
{ "0x1000" , "Topview Kamera Au<41>enspiegel links" , "1" },
{ "0x1100" , "Topview Kamera Au<41>enspiegel rechts" , "1" },
{ "0x1200" , "Sideview Kamera Sto<74>f<EFBFBD>nger vorne links", "1" },
{ "0x1300" , "Sideview Kamera Sto<74>f<EFBFBD>nger vorne rechts", "1" },
// JBBF
{ "0x1400" , "Wischermotor" , "1" },
{ "0x1500" , "Regen- Lichtsensor" , "1" },
{ "0x1600" , "Innenspiegel" , "1" },
{ "0x1700" , "Garagentor<6F>ffner" , "1" },
{ "0x1800" , "AUC-Sensor" , "1" },
{ "0x1900" , "Druck- Temperatursensor" , "1" },
//{ "0x1A00" , "@Schalterblock@ @Sitzheizung@ @hinten@" , "1" },
{ "0x1A20" , "Schalterblock Sitzheizung hinten links", "1" },
{ "0x1A40" , "Schalterblock Sitzheizung hinten rechts", "1" },
{ "0x1A60" , "Sitzheizung Fahrer" , "1" },
{ "0x1A80" , "Sitzheizung Beifahrer" , "1" },
{ "0x1AA0" , "Sitzheizung Fahrer hinten" , "1" },
{ "0x1AC0" , "Sitzheizung Beifahrer hinten" , "1" },
{ "0x1B00" , "Schalterblock Sitzmemory/-massage Fahrer", "1" },
{ "0x1C00" , "Schalterblock Sitzmemory/-massage Beifahrer", "1" },
{ "0x1C80" , "Sitzverstellschalter Beifahrer <20>ber Fond" , "1" },
{ "0x1D00" , "Sonnenrollo Seitenfenster Fahrer" , "1" },
{ "0x1E00" , "Sonnenrollo Seitenfenster Beifahrer" , "1" },
{ "0x1E40" , "Heckklappenemblem" , "1" },
{ "0x1F00" , "KAFAS Kamera" , "1" },
{ "0x2000" , "Automatische Anh<6E>ngevorrichtung" , "1" },
{ "0x2100" , "SINE" , "1" },
// CAN Sine
{ "0x2110" , "DWA Mikrowellensensor vorne rechts" , "1" },
{ "0x2120" , "DWA Mikrowellensensor hinten rechts" , "1" },
{ "0x2130" , "DWA Mikrowellensensor hinten links" , "1" },
{ "0x2140" , "DWA Mikrowellensensor vorne links" , "1" },
{ "0x2150" , "DWA Mikrowellensensor hinten" , "1" },
{ "0x2180" , "DWA Ultraschallsensor" , "1" },
// FRM3
{ "0x2200" , "Aussenspiegel Fahrer" , "-" },
{ "0x2300" , "Aussenspiegel Beifahrer" , "-" },
{ "0x2400" , "Schaltzentrum T<>r" , "1" },
{ "0x2500" , "Schalterblock Sitz Fahrer" , "1" },
{ "0x2600" , "Schalterblock Sitz Beifahrer" , "1" },
{ "0x2700" , "Gurtbringer Fahrer" , "1" },
{ "0x2800" , "Gurtbringer Beifahrer" , "1" },
{ "0x2900" , "Treibermodul Scheinwerfer links" , "1" },
{ "0x2A00" , "Treibermodul Scheinwerfer rechts" , "1" },
{ "0x2B00" , "Bedieneinheit Fahrerassistenzsysteme" , "1" },
{ "0x2C00" , "Bedieneinheit Licht" , "1" },
{ "0x2D00" , "Smart Opener" , "1" },
{ "0x2E00" , "LED-Hauptlicht-Modul links" , "1" },
{ "0x2F00" , "LED-Hauptlicht-Modul rechts" , "1" },
// CAS4
{ "0x0910" , "Elektrische Lenks<6B>ulenverriegelung" , "1" },
{ "0x3200" , "Funkempf<70>nger" , "1" },
{ "0x3300" , "Funkempf<70>nger 2" , "1" },
{ "0x3400" , "T<>rgriffelektronik Fahrer" , "-" },
{ "0x3500" , "T<>rgriffelektronik Beifahrer" , "-" },
{ "0x3600" , "T<>rgriffelektronik Fahrer hinten" , "-" },
{ "0x3700" , "T<>rgriffelektronik Beifahrer hinten" , "-" },
{ "0x3800" , "Telestart-Handsender 1" , "-" },
{ "0x3900" , "Telestart-Handsender 2" , "-" },
{ "0x3A00" , "Fond-Fernbedienung" , "-" },
// DME
{ "0x3B00" , "Elektrische Wasserpumpe" , "1" },
{ "0x3B10" , "Elektrische Wasserpumpe 1" , "1" },
{ "0x3B20" , "Elektrische Wasserpumpe 2" , "1" },
{ "0x3B80" , "Elektrische Zusatzwasserpumpe" , "1" },
{ "0x3C00" , "Batteriesensor LIN" , "-" },
{ "0x3D00" , "Aktives K<>hlklappensystem" , "1" },
{ "0x3E00" , "PCU(DCDC)" , "1" },
{ "0x3E80" , "DCDC Versorgung Zustartbatterie" , "1" },
{ "0x3F00" , "Startergenerator" , "1" },
{ "0x3F80" , "Generator" , "1" },
// Sitzmodul
{ "0x4000" , "Sitzverstellschalter Fahrer" , "1" },
{ "0x4100" , "Sitzverstellschalter Beifahrer" , "1" },
{ "0x4200" , "Sitzverstellschalter Fahrer hinten" , "1" },
{ "0x4300" , "Sitzverstellschalter Beifahrer hinten" , "1" },
{ "0x4400" , "Gep<65>ckraumschalter links" , "1" },
{ "0x4500" , "Gep<65>ckraumschalter rechts" , "1" },
{ "0x4600" , "Nackenw<6E>rmer" , "1" },
{ "0x4700" , "Nackenw<6E>rmer Bedienschalter" , "1" },
// Klima
{ "0x4A00" , "Fond-Klimaanlage" , "1" },
{ "0x4B00" , "Elektrischer Klimakompressor" , "1" },
{ "0x4C00" , "Klimabedienteil" , "1" },
{ "0x4D00" , "Gebl<62>seregler" , "1" },
{ "0x4E00" , "Klappenmotor" , "0" },
{ "0x4F00" , "Elektrischer K<>ltemittelverdichter eKMV" , "1" },
{ "0x4F80" , "Elektrischer Zuheizer PTC" , "1" },
{ "0x6000" , "Standheizung" , "1" },
{ "0x6100" , "W<>rmepumpe" , "1" },
{ "0x6200" , "elektrischer Durchlaufheizer" , "1" },
{ "0x6300" , "Ionisator" , "1" },
{ "0x6400" , "Bedufter" , "1" },
// PMA
{ "0x5000" , "PMA Sensor links" , "1" },
{ "0x5100" , "PMA Sensor rechts" , "1" },
// CDM RR04
{ "0x5200" , "CID-Klappe" , "-" },
// F25
{ "0x5300" , "Schaltzentrum Lenks<6B>ule" , "1" },
{ "0x5400" , "Multifunktionslenkrad" , "1" },
{ "0x5500" , "Lenkradelektronik" , "1" },
// CID L7
{ "0x5600" , "CID" , "-" },
// ACSM 4
{ "0x5700" , "Satellit Upfront links" , "0" },
{ "0x5708" , "Satellit Upfront rechts" , "0" },
{ "0x5710" , "Satellit T<>r links" , "0" },
{ "0x5718" , "Satellit T<>r rechts" , "0" },
{ "0x5720" , "Satellit B-S<>ule links X" , "0" },
{ "0x5728" , "Satellit B-S<>ule rechts X" , "0" },
{ "0x5730" , "Satellit B-S<>ule links Y" , "0" },
{ "0x5738" , "Satellit B-S<>ule rechts Y" , "0" },
{ "0x5740" , "Satellit Zentralsensor X" , "0" },
{ "0x5748" , "Satellit Zentralsensor Y" , "0" },
{ "0x5750" , "Satellit Zentralsensor Low g Y" , "0" },
{ "0x5758" , "Satellit Zentralsensor Low g Z" , "0" },
{ "0x5760" , "Satellit Zentralsensor Roll Achse" , "0" },
{ "0x5768" , "Fussg<73>ngerschutz Sensor links" , "0" },
{ "0x5770" , "Fussg<73>ngerschutz Sensor rechts" , "0" },
{ "0x5778" , "Fussg<73>ngerschutz Sensor mitte" , "0" },
{ "0x5780" , "Fussg<73>ngerschutzsensor statisch" , "0" },
{ "0x5788" , "Satellit C-S<>ule links Y" , "0" },
{ "0x5790" , "Satellit C-S<>ule rechts Y" , "0" },
{ "0x5798" , "Satellit Zentrale K<>rperschall" , "0" },
{ "0x57A0" , "Kapazitive Insassen- Sensorik CIS" , "1" },
{ "0x57A8" , "Sitzbelegungserkennung Beifahrer SBR" , "1" },
{ "0x57B0" , "Fussg<73>ngerschutzsensor dynamisch 1" , "0" },
{ "0x57B8" , "Fussg<73>ngerschutzsensor dynamisch 2" , "0" },
{ "0x5800" , "HUD" , "1" },
{ "0x5900" , "Audio-Bedienteil" , "1" },
{ "0x5A00" , "Innenlichtelektronik" , "1" },
// Mini F56
{ "0x5B00" , "Zentralinstrument" , "-" },
// BDC
{ "0x5C00" , "Elektrische Lenks<6B>ulenverstellung ELSV" , "1" },
{ "0x5D00" , "Hands-Off Detection HOD" , "1" },
{ "0x5E01" , "Innenbeleuchtung Fu<46>raum Fahrer vorne" , "1" },
{ "0x5E02" , "Innenbeleuchtung Fu<46>raum Fahrer hinten" , "1" },
{ "0x5E03" , "Innenbeleuchtung Fu<46>raum Beifahrer vorne" , "1" },
{ "0x5E04" , "Innenbeleuchtung Fu<46>raum Beifahrer hinten" , "1" },
{ "0x5E05" , "Innenbeleuchtung Fahrert<72>r vorne oben" , "1" },
{ "0x5E06" , "Innenbeleuchtung Fahrert<72>r vorne Mitte" , "1" },
{ "0x5E07" , "Innenbeleuchtung Fahrert<72>r vorne unten" , "1" },
{ "0x5E08" , "Innenbeleuchtung Fahrert<72>r vorne Kartentasche" , "1" },
{ "0x5E09" , "Innenbeleuchtung Fahrert<72>r hinten oben" , "1" },
{ "0x5E0A" , "Innenbeleuchtung Fahrert<72>r hinten unten" , "1" },
{ "0x5E0B" , "Innenbeleuchtung Fahrert<72>r hinten Kartentasche" , "1" },
{ "0x5E0C" , "Innenbeleuchtung Beifahrert<72>r vorne oben" , "1" },
{ "0x5E0D" , "Innenbeleuchtung Beifahrert<72>r vorne Mitte" , "1" },
{ "0x5E0E" , "Innenbeleuchtung Beifahrert<72>r vorne unten" , "1" },
{ "0x5E0F" , "Innenbeleuchtung Beifahrert<72>r vorne Kartentasche" , "1" },
{ "0x5E10" , "Innenbeleuchtung Beifahrert<72>r hinten oben" , "1" },
{ "0x5E11" , "Innenbeleuchtung Beifahrert<72>r hinten unten" , "1" },
{ "0x5E12" , "Innenbeleuchtung Beifahrert<72>r hinten Kartentasche", "1" },
{ "0x5E13" , "Innenbeleuchtung I-Tafel Fahrer oben" , "1" },
{ "0x5E14" , "Innenbeleuchtung I-Tafel Fahrer unten" , "1" },
{ "0x5E15" , "Innenbeleuchtung I-Tafel oben Mitte" , "1" },
{ "0x5E16" , "Innenbeleuchtung I-Tafel unten Mitte" , "1" },
{ "0x5E17" , "Innenbeleuchtung I-Tafel oben Beifahrer" , "1" },
{ "0x5E18" , "Innenbeleuchtung I-Tafel unten Beifahrer" , "1" },
{ "0x5E19" , "Innenbeleuchtung B-S<>ule Fahrer" , "1" },
{ "0x5E1A" , "Innenbeleuchtung B-S<>ule Beifahrer" , "1" },
{ "0x5E1B" , "Innenbeleuchtung Lehne Fahrersitz" , "1" },
{ "0x5E1C" , "Innenbeleuchtung Lehne Beifahrersitz" , "1" },
{ "0x5E1D" , "Innenbeleuchtung Centerstack" , "1" },
{ "0x5E1E" , "Innenbeleuchtung Mittelkonsole Ablagefach" , "1" },
{ "0x5E1F" , "Innenbeleuchtung Gangwahlschalter links" , "1" },
{ "0x5E20" , "Innenbeleuchtung Gangwahlschalter rechts" , "1" },
{ "0xFFFF" , "unbekannter Verbauort" , "-" }
};
// Zuordnung von Teilenummer zu BMW-Teilenummer
// intelligenter Sensoren
// wenn vom Sensor nicht gegeben
table PartNrTabelle[3][] = {
{ "PART_NR" , "BMW_NR" , "KOMMENTAR" },
//{ "1234567890" , "1234567" , "Lin-Sensor Schrittmotor" },
{ "--" , "--" , "unbekannte Teilenummer" }
};
// end of : #include "STD_ISEN.b2s"
// UDS Standard Tabelle (f<>r Job Sensoren_Ident_Lesen)
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_TAB_LieferantenLIN.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'LIN-Lieferantennummer <-> LIN-Lieferantentext'
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 07.02.2007 gr V0.001 Ersterstellung auf www.lin-subbus.org -> Consortium\Supplier Codes
// 15.02.2007 gr V1.000 Freigabe
// 12.09.2007 gr V1.001 Nummer 0x51 bis 0x55 hinzu
// 26.02.2008 gr V1.002 Nummer 0x56 und 0x57 hinzu
// 25.03.2008 gr V1.003 Nummer 0x58 und 0x59 hinzu
// 17.07.2008 gr V1.004 Nummer 0x5A bis 0x5C hinzu
// 05.03.2009 gr V1.005 Nummer 0x60 bis 0x67 hinzu
// 09.07.2009 gr V1.006 Nummer 0x68 hinzu
// 07.08.2009 gr V1.007 Nummer 0x66 hinzu
// 16.11.2009 gr V1.008 Nummer 0x69 hinzu
// 16.11.2010 ms V1.009 Nummer 0x70 bis 0x73 hinzu
// *******************************************************************
// UDS_TAB_LieferantenLIN.B2S @(#)@ V1.009@(#)@
// *******************************************************************
#define INCLUDE_UDS_LieferantenLIN_B2S_NOT_FOUND
table LieferantenLIN[2][] = {
{ "LIEF_NR" , "LIEF_TEXT" },
{ "0x0001" , "Audi" },
{ "0x0002" , "BMW" },
{ "0x0003" , "DaimlerChrysler" },
{ "0x0004" , "Motorola" },
{ "0x0005" , "VCT/Mentor Graphics" },
{ "0x0006" , "VW (VW-Group)" },
{ "0x0007" , "Volvo Cars (Ford Group)" },
{ "0x000B" , "Freescale Semiconductor" },
{ "0x0011" , "NXP Semiconductors" },
{ "0x0012" , "ST Microelectronics" },
{ "0x0013" , "Melexis" },
{ "0x0014" , "Microchip" },
{ "0x0015" , "CRF" },
{ "0x0016" , "Renesas Technology Europe GmbH" },
{ "0x0017" , "Atmel" },
{ "0x0018" , "Magnet Marelli" },
{ "0x0019" , "NEC" },
{ "0x001A" , "Fujitsu" },
{ "0x001B" , "Opel" },
{ "0x001C" , "Infineon" },
{ "0x001D" , "AMI Semiconductor" },
{ "0x001E" , "Vector Informatik" },
{ "0x001F" , "Brose" },
{ "0x0020" , "ZMD" },
{ "0x0021" , "ihr" },
{ "0x0022" , "Visteon" },
{ "0x0023" , "ELMOS" },
{ "0x0024" , "ON Semi" },
{ "0x0025" , "Denso" },
{ "0x0026" , "c&s" },
{ "0x0027" , "Renault" },
{ "0x0028" , "Renesas Technology Europe Limited" },
{ "0x0029" , "Yazaki" },
{ "0x002A" , "Trinamic Microchips" },
{ "0x002B" , "Allegro Microsystems" },
{ "0x002C" , "Toyota" },
{ "0x002D" , "PSA Peugeot Citro<72>n" },
{ "0x002E" , "Wests<74>chsische Hochschule Zwickau" },
{ "0x002F" , "Micron AG" },
{ "0x0030" , "Delphi Deutschland GmbH" },
{ "0x0031" , "Texas Instruments Deutschland GmbH" },
{ "0x0032" , "Maxim Integrated Products" },
{ "0x0033" , "Bertrandt Ingenierb<72>ro GmbH" },
{ "0x0034" , "PKC Group Oyi" },
{ "0x0035" , "BayTech IKs" },
{ "0x0036" , "Hella KGaA Hueck & Co." },
{ "0x0037" , "Continental Temic microelectronic GmbH"},
{ "0x0038" , "Johnson Controls GmbH" },
{ "0x0039" , "Toshiba Electronics Europe GmbH" },
{ "0x003A" , "Analog Devices" },
{ "0x003B" , "TRW Automotive Electronics & Components GmbH & Co. KG" },
{ "0x003C" , "Advanced Data Controls, Corp." },
{ "0x003D" , "G<>PEL electronic GmbH" },
{ "0x003E" , "Dr. Ing. h.c. F. Porsche AG" },
{ "0x003F" , "Marquardt GmbH" },
{ "0x0040" , "ETAS GmbH" },
{ "0x0041" , "Micronas GmbH" },
{ "0x0042" , "Preh GmbH" },
{ "0x0043" , "GENTEX CORPORATION" },
{ "0x0044" , "ZF Lenksysteme GmbH" },
{ "0x0045" , "Nagares S.A." },
{ "0x0046" , "MAN Nutzfahrzeuge AG" },
{ "0x0047" , "BITRON SpA BU Grugliasco" },
{ "0x0048" , "Pierburg GmbH" },
{ "0x0049" , "Alps Electric Co., Ltd" },
{ "0x004A" , "Beru Electronics GmbH" },
{ "0x004B" , "Paragon AG" },
{ "0x004C" , "Silicon Laboratories" },
{ "0x004D" , "Sensata Technologies Holland B.V." },
{ "0x004E" , "Meta System S.p.A" },
{ "0x004F" , "Dr<44>xlmaier Systemtechnik GmbH" },
{ "0x0050" , "Grupo Antolin Ingenieria, S.A." },
{ "0x0051" , "MAGNA-Donnelly GmbH&Co.KG" },
{ "0x0052" , "IEE S.A." },
{ "0x0053" , "austriamicrosystems AG" },
{ "0x0054" , "Agilent Technologies" },
{ "0x0055" , "Lear Corporation " },
{ "0x0056" , "KOSTAL Ireland GmbH" },
{ "0x0057" , "LIPOWSKY Industrie-Elektronik GmbH " },
{ "0x0058" , "Sanken Electric Co.,Ltd" },
{ "0x0059" , "Elektrobit Automotive GmbH" },
{ "0x005A" , "VIMERCATI S.p.A." },
{ "0x005B" , "AB Volvo" },
{ "0x005C" , "SMSC Europe GmbH" },
{ "0x0060" , "Sitronic" },
{ "0x0061" , "Flextronics / Sidler Automotive" },
{ "0x0062" , "EAO Automotive" },
{ "0x0063" , "helag-electronic" },
{ "0x0064" , "Magna International" },
{ "0x0065" , "ARVINMERITOR" },
{ "0x0066" , "Valeo SA" },
{ "0x0067" , "Defond Holding / BJAutomotive" },
{ "0x0068" , "Industrie Saleri S. p. A." },
{ "0x0069" , "ROHM Semiconductor GmbH" },
{ "0x0070" , "Alfmeier AG" },
{ "0x0071" , "Sanden Corporation" },
{ "0x0072" , "Huf H<>lsbeck & F<>rst GmbH&Co KG" },
{ "0x0073" , "ebm-papst St. Georgen GmbH&Co. KG" },
{ "0xFFFF" , "unbekannter Hersteller" }
};
// end of : #include "UDS_TAB_LieferantenLIN.B2S"
// UDS Standard Tabelle (f<>r Job IS_Lesen)
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_TAB_IArtTexte.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'Fehlerart-Nr -> Fehlerart-Text'
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 05.12.2005 gr V0.001 Ersterstellung aus Basis UDS_TAB_FART.B2S
// 02.02.2006 gr V0.002 Anpassungen an neue DTCStatusMask 0C
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Tabellen-Name)
// 01.04.2008 as V0.003 Texte ge<67>ndert
// *******************************************************************
// UDS_TAB_IArtTexte.B2S @(#)@ V0.003 @(#)@
// *******************************************************************
#define INCLUDE_UDS_TAB_IArtTexte_B2S_NOT_FOUND
table IArtTexte[2][] = {
{ "ARTNR" , "ARTTEXT" },
{ "0x00" , "keine Fehlerart verf<72>gbar" },
{ "0x04" , "Fehler momentan nicht vorhanden, aber bereits gespeichert" },
{ "0x05" , "Fehler momentan vorhanden und bereits gespeichert" },
{ "0x08" , "Fehler momentan nicht vorhanden, aber bereits gespeichert" },
{ "0x09" , "Fehler momentan vorhanden und bereits gespeichert" },
{ "0x0C" , "Fehler momentan nicht vorhanden, aber bereits gespeichert" },
{ "0x0D" , "Fehler momentan vorhanden und bereits gespeichert" },
{ "0x44" , "Fehler gespeichert" },
{ "0x45" , "Fehler gespeichert" },
{ "0x48" , "Fehler gespeichert" },
{ "0x49" , "Fehler gespeichert" },
{ "0x4C" , "Fehler gespeichert" },
{ "0x4D" , "Fehler gespeichert" },
{ "0x10" , "Testbedingungen erf<72>llt" },
{ "0x11" , "Testbedingungen noch nicht erf<72>llt" },
{ "0x80" , "Fehler w<>rde kein Aufleuchten einer Warnlampe verursachen" },
{ "0x81" , "Fehler w<>rde das Aufleuchten einer Warnlampe verursachen" },
{ "0xFF" , "unbekannte Fehlerart" }
};
// end of : #include "UDS_TAB_IArtTexte.B2S"
// UDS Standard Tabelle (f<>r Job Response_On_Event)
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_TAB_ROE_AKTIV.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Verantwortung : BMW AG, Tobias Kraeker, EI-71
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'STAT_ROE_AKTIV-Nr -> STAT_ROE_AKTIV-Text'
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnosemaster
//
// -------------------------------------------------------------------
// History:
// 30.11.2006 aN V0.001 Ersterstellung (Albrecht Neff, EI-71)
//
// *******************************************************************
// UDS_TAB_ROE_AKTIV.B2S @(#)@ V0.001 @(#)@
// *******************************************************************
#define INCLUDE_UDS_TAB_ROE_AKTIV_B2S_NOT_FOUND
table UDS_TAB_ROE_AKTIV[2][] =
{
{ "NR" , "TEXT"},
{ "0x00" , "Aktive Fehlermeldung deaktiviert"},
{ "0x01" , "Aktive Fehlermeldung aktiviert"},
{ "0xFF" , "Status der aktiven Fehlermeldung nicht feststellbar"}
};
// end of : #include "UDS_TAB_ROE_AKTIV.B2S"
// *******************************************************************
// Tabellen
// *******************************************************************
table JobResultExtended[2][]={
{ "SB", "STATUS_TEXT" },
{ "0xXY", "ERROR_UNKNOWN" }
};
// Tabelle wird bei den Jobs: STATUS_BETRIEBSMODE / STEUERN_BETRIEBSMODE ben<65>tigt
table Betriebsmode[3][]={
{ "WERT", "TEXT", "BEDEUTUNG" },
{ "0x00", "Allgemeiner Fertigungs- und Energiesparmode", "Hier deaktivierte Funktionen gem<65><6D> FeTra-Liste festhalten" },
{ "0x01", "Spezieller Energiesparmode", "-" },
{ "0x02", "ECOS-Mode", "-" },
{ "0x03", "MOST-Mode", "-" },
{ "0x04", "Rollenmode", "-" },
{ "0xFF", "ung<6E>ltiger Betriebsmode", "ung<6E>ltig" }
};
table FOrtTexte[3][]={
{ "ORT", "ORTTEXT", "EREIGNIS_DTC" },
{ "0x021A00", "Energiesparmode aktiv", "0" },
{ "0x021A08", "Codierung: Steuerger<65>t ist nicht codiert", "0" },
{ "0x021A09", "Codierung: Fehler bei Codierdatentransaktion aufgetreten", "0" },
{ "0x021A0A", "Codierung: Signatur der Codierdaten ung<6E>ltig", "0" },
{ "0x021A0B", "Codierung: Codierdaten passen nicht zum Fahrzeug", "0" },
{ "0x021A0C", "Codierung: Unplausible Daten w<>hrend Codierdatentransaktion", "0" },
{ "0x02FF1A", "Dummy-Fehlerspeichereintrag im Komponentenfehlerbereich nur f<>r Testzwecke", "1" },
{ "0x21EA00", "interner Fehler, Ebene3, ROM-Fehler mc0", "0" },
{ "0x21EA01", "interner Fehler, Ebene3, RAM-Fehler mc0", "0" },
{ "0x21EA02", "interner Fehler, Ebene3, Stack-Fehler mc0", "0" },
{ "0x21EA06", "interner Fehler, FZM: Systemzustand unplausibel", "0" },
{ "0x21EA07", "ELUP: Allgemeiner Elup Fehler", "0" },
{ "0x21EA08", "ELUP: Betriebsbedingungen der Elup nicht erf<72>llt. M<>gliche Ursachen sind Montage Mode oder Spannung au<61>erhalb von 9 - 16 V", "0" },
{ "0x21EA09", "Parksperre, Sensor: Signal 1 Kurzschluss nach Masse", "0" },
{ "0x21EA0A", "Parksperre, Sensor: Signal 1 Kurzschluss nach Plus", "0" },
{ "0x21EA0B", "Parksperre, Sensor: Signal 2 Kurzschluss nach Masse", "0" },
{ "0x21EA0C", "Parksperre, Sensor: Signal 2 Kurzschluss nach Plus", "0" },
{ "0x21EA0D", "Parksperre, Sensor: Sensoren inkonsistent", "0" },
{ "0x21EA0E", "Parksprerre, HB-Spannung: nicht im zul<75>ssigen Bereich", "0" },
{ "0x21EA10", "Parksprerre, Aktuator: Maximalstrom<6F>berwachung", "0" },
{ "0x21EA11", "Parksperre, Aktuator: PS-Position in der zul<75>ssigen Zeit nicht erreicht", "0" },
{ "0x21EA12", "Parksperre, Aktuator: keine <20>nderung der PS-Position", "0" },
{ "0x21EA13", "Parksperre, Aktuator: angeforderte Position konnte nicht erreicht werden", "0" },
{ "0x21EA14", "Parksperre, Init: Keine Daten f<>r PS offen/geschlossen im NV-Ram vorhanden", "0" },
{ "0x21EA15", "Parksperre, EWS: Abgleich nicht erfolgreich", "0" },
{ "0x21EA16", "interner Fehler, Ebene3, Doppelablage-Fehler mc0", "0" },
{ "0x21EA17", "interner Fehler, Ebene3, Interner ADC-Fehler mc0", "0" },
{ "0x21EA19", "interner Fehler, Ebene3, Programablauf-Fehler mc0", "0" },
{ "0x21EA1A", "ELUP, Sensor: Unterdrucksensor elektrischer Fehler", "0" },
{ "0x21EA1B", "ELUP, Aktuator: keine Gegeninduktion", "0" },
{ "0x21EA1C", "ELUP, Aktuator: Kurzschluss nach Plus", "0" },
{ "0x21EA1D", "ELUP, Aktuator: Kurzschluss nach Masse", "0" },
{ "0x21EA1E", "ELUP, Aktuator: Unterbrechung oder nicht angesteckt", "0" },
{ "0x21EA1F", "ELUP, Treiber: Strom zu hoch", "0" },
{ "0x21EA20", "ELUP, Treiber: Schaltet nicht durch", "0" },
{ "0x21EA21", "ELUP, Treiber: Temperatur zu hoch", "0" },
{ "0x21EA22", "ELUP, Sensor: Temperatur Sensor defekt", "0" },
{ "0x21EA23", "interner Fehler, Ebene3, Konfigregister-Fehler mc0", "0" },
{ "0x21EA24", "interner Fehler, Ebene3, Ebene2Prime-Fehler mc0", "0" },
{ "0x21EA25", "interner Fehler, Ebene3, Externer Watchdog-Fehler mc0", "0" },
{ "0x21EA27", "Interner Fehler, Montagemodus aktiv", "0" },
{ "0x21EA28", "Parksperre, FUSI: Ebene1/Ebene2 Fehler", "0" },
{ "0x21EA29", "FUSI, L<>ngsdynamik: Quadrantenplausibilisierung", "0" },
{ "0x21EA2A", "F_M_BMW_CCM636_FAULTTYPE -> Checkcontrol 636 : Hochvoltsystem abgeschaltet", "1" },
{ "0x21EA2B", "F_M_BMW_CCM802_FAULTTYPE -> Checkcontrol 802 : Ladekabel pruefen", "1" },
{ "0x21EA2C", "F_M_BMW_CCM803_FAULTTYPE -> Checkcontrol 803 : Netzleistung zu gering", "1" },
{ "0x21EA2D", "F_M_BMW_CCM804_FAULTTYPE -> Checkcontrol 804 : Laden nicht moeglich", "1" },
{ "0x21EA2E", "F_M_BMW_CCM809_FAULTTYPE -> Checkcontrol 809 : Zum Laden P einlegen", "1" },
{ "0x21EA2F", "F_M_BMW_HVAUS_SOC_FAULTTYPE -> HV Powermanagement : HV Power Down aufgrund niedrigem Ladezustand HV Batterie", "0" },
{ "0x21EA30", "Hochvoltbatterie - Temperatur kritischer Wert", "0" },
{ "0x21EA31", "Hochvoltbatterie - Temperatur verl<72>sst Normalbereich", "0" },
{ "0x21EA32", "Hochvoltbatterie - Temperatur wieder im Normalbereich", "0" },
{ "0x21EA33", "F_M_BMW_LADEN_AC_ABBRUCH_FAULTTYPE -> Lademanagement : AC Spannung fehlt nach Ladebeginn", "0" },
{ "0x21EA34", "F_M_BMW_LADEN_AC_INSTABIL_FAULTTYPE -> Lademanagement : AC Spannung dauerhaft instabil", "0" },
{ "0x21EA35", "F_M_BMW_LADEN_FAILSAFE_FAULTTYPE -> Lademanagement : SLE/KLE in Failsafe", "0" },
{ "0x21EA36", "F_M_BMW_LADEN_LADEFEHLER_FAULTTYPE -> Lademanagement : Ladefehler", "0" },
{ "0x21EA37", "F_M_BMW_LADEN_LADEZIEL_FAULTTYPE -> Lademanagement : Ladeziel nicht erreichbar (SLE Leistung zu gering)", "0" },
{ "0x21EA38", "F_M_BMW_LADEN_NVBN_FAULTTYPE -> Lademanagement : Ladeziel nicht erreichbar (Entladeschutz NV BN)", "0" },
{ "0x21EA39", "F_M_BMW_LADEN_STECKER_UBK_FAULTTYPE -> Lademanagement : Zustand Ladestecker unbekannt", "0" },
{ "0x21EA3A", "F_M_BMW_LADEN_STOERUNG_FAULTTYPE -> Lademanagement : Ladestoerung", "0" },
{ "0x21EA3B", "F_M_BMW_PILOT_UNGUELTIG_FAULTTYPE -> Lademanagement : Pilotsignal ungueltig", "0" },
{ "0x21EA3C", "F_M_BMW_PILOT_UNGUELTIG_LK_FAULTTYPE -> Lademanagement : Pilotsignal ungueltig ausserhalb Ladebereitschaft", "0" },
{ "0x21EA3D", "F_M_BMW_VOKO_FEHLER_FAULTTYPE -> Lademanagement : Vorkonditionierung nicht moglich", "0" },
{ "0x21EA3E", "HV-Powermanagement: Anforderung Entlastung DCDC-Wandler an AEP", "1" },
{ "0x21EA3F", "Crash: Z<>ndpille aktiviert", "1" },
{ "0x21EA40", "HV-Powermanagement: HV Erstfreigabe erfolgt", "0" },
{ "0x21EA41", "F_M_BMW_HVBATT_ISOWARN_FAULTTYPE -> HV Batterie : Isolationswarnung", "0" },
{ "0x21EA42", "F_M_BMW_HVOFF_FAIL_FAULTTYPE -> HV Zwischenkreisentladung : HV Zwischenkreis nicht spannungsfrei trotz Anforderung", "1" },
{ "0x21EA43", "F_M_BMW_INLK_SYS_FAULTTYPE -> HV Powermanagement : Interlock unterbrochen", "0" },
{ "0x21EA44", "F_M_BMW_SCHUETZKLEBER_1_FAULTTYPE -> HV Batterie : einfacher Schuetzkleber", "0" },
{ "0x21EA45", "AE, ELUP, Unterdrucksystem, Lekage erkannt", "0" },
{ "0x21EA46", "AE, ELUP, Unterdrucksystem, Elektrische Unterdruckpumpe maximale Laufzeit <20>berschritten (Dauerlauf)", "0" },
{ "0x21EA47", "AE, ELUP, Unterdrucksystem, Elektrische Unterdruckpumpe F<>rderleistung zu gering", "0" },
{ "0x21EA48", "AE, ELUP, Unterdrucksystem, Unterdruckniveau zu gering", "0" },
{ "0x21EA49", "AE, ELUP, Unterdrucksystem, Unterdrucksensor Messwert au<61>erhalb g<>ltigem Bereich", "0" },
{ "0x21EA4A", "AE, ELUP, Unterdrucksystem, F<>rderleistung mechanische Pumpe zu gering, oder R<>ckschlagventil defekt", "0" },
{ "0x21EA4B", "Ganghaenger in N Getriebe der elektrische Achse", "1" },
{ "0x21EA4C", "Ganghaenger im 1. Gang Getriebe der elektrische Achse", "1" },
{ "0x21EA4D", "Ganghaenger im 2. Gang Getriebe der elektrische Achse", "1" },
{ "0x21EA4E", "Gang Getriebe der elektrische Achse unbekannt", "1" },
{ "0x21EA4F", "FIS EWP Zustand unbekannt", "1" },
{ "0x21EA60", "DCDC, Messwert<72>berpr<70>fung, Fataler Fehler in Messwerterfassung U_LV", "0" },
{ "0x21EA61", "DCDC, Messwert<72>berpr<70>fung, Fataler Fehler in Messwerterfassung I_LV", "0" },
{ "0x21EA62", "DCDC, Messwert<72>berpr<70>fung, Fehler in Messwerterfassung_Notlauf m<>glich", "0" },
{ "0x21EA6B", "DCDC, ProtectionHandler, Strom auf LV-Seite zu hoch", "0" },
{ "0x21EA6E", "DCDC, ProtectionHandler, Spannung auf LV-Seite zu hoch", "0" },
{ "0x21EA71", "DCDC, <20>berwachung, Spannung auf HV-Seite zu hoch", "0" },
{ "0x21EA72", "DCDC, <20>berwachung, Spannung auf HV-Seite zu niedrig", "0" },
{ "0x21EA76", "DCDC, <20>berwachung, Fehler Masseanbindung_Notlauf", "0" },
{ "0x21EA77", "Hochvoltsicherheitsmanager, HW AKS aktiv, Anforderer: Crash Klemme 30C", "0" },
{ "0x21EA78", "Hochvoltsicherheitsmanager, HW AKS aktiv, Anforderer: CY320 MC0", "0" },
{ "0x21EA79", "Hochvoltsicherheitsmanager, HW AKS aktiv, Anforderer: CY320 MC2", "0" },
{ "0x21EA95", "interner Fehler, Ebene3, ROM-Fehler mc2", "0" },
{ "0x21EA96", "interner Fehler, Ebene3, RAM-Fehler mc2", "0" },
{ "0x21EA97", "interner Fehler, Ebene3, Stack-Fehler mc2", "0" },
{ "0x21EA98", "interner Fehler, Ebene3, Doppelablage-Fehler mc2", "0" },
{ "0x21EA99", "interner Fehler, Ebene3, Interner ADC-Fehler mc2", "0" },
{ "0x21EA9B", "interner Fehler, Ebene3, Programablauf-Fehler mc2", "0" },
{ "0x21EA9C", "interner Fehler, Ebene3, Konfigregister-Fehler mc2", "0" },
{ "0x21EA9D", "interner Fehler, Ebene3, Ebene2Prime-Fehler mc2", "0" },
{ "0x21EA9E", "interner Fehler, Ebene3, Externer Watchdog-Fehler mc2", "0" },
{ "0x21EA9F", "interner Fehler, FUSI, Abschaltpfadtest-Fehler mc2", "0" },
{ "0x21EAA1", "Sensorfehler, Messwerterfassung, Winkelgeber/Drehzahlgeber defekt", "0" },
{ "0x21EAAE", "interner Fehler, AEPH, Zwischenkreisspannung oberen Grenzwert <20>berschritten", "0" },
{ "0x21EAAF", "interner Fehler, AEPH, Zwischenkreisspannung unteren Grenzwert unterschritten", "0" },
{ "0x21EAB2", "interner Fehler, AEPH, Gatetreiber Zwischenkreisspannung oberen Grenzwert <20>berschritten", "0" },
{ "0x21EAB3", "interner Fehler, AEPH, Gatetreiber Zwischenkreisspannung unteren Grenzwert unterschritten", "0" },
{ "0x21EAB4", "interner Fehler, AEPH, Interne 12V-Versorgungsspannung oberen Grenzwert <20>berschritten", "0" },
{ "0x21EAB5", "interner Fehler, AEPH, Interne 12V-Versorgungsspannung unteren Grenzwert unterschritten", "0" },
{ "0x21EAB6", "interner Fehler, AEPH, Interne 5V-Spannung vom CY320_MC0 oberen Grenzwert <20>berschritten", "0" },
{ "0x21EAB7", "interner Fehler, AEPH, Interne 5V-Spannung vom CY320_MC0 unteren Grenzwert unterschritten", "0" },
{ "0x21EAB8", "interner Fehler, AEPH, Interne 3V3-Spannung vom CY320_MC0 oberen Grenzwert <20>berschritten", "0" },
{ "0x21EAB9", "interner Fehler, AEPH, Interne 3V3-Spannung vom CY320_MC0 unteren Grenzwert unterschritten", "0" },
{ "0x21EABA", "interner Fehler, AEPH, Interne 1V5-Spannung vom CY320_MC0 oberen Grenzwert <20>berschritten", "0" },
{ "0x21EABB", "interner Fehler, AEPH, Interne 1V5-Spannung vom CY320_MC0 unteren Grenzwert unterschritten", "0" },
{ "0x21EABC", "interner Fehler, AEPH, Interne 5V-Spannung vom CY320_MC2 oberen Grenzwert <20>berschritten", "0" },
{ "0x21EABD", "interner Fehler, AEPH, Interne 5V-Spannung vom CY320_MC2 unteren Grenzwert unterschritten", "0" },
{ "0x21EABE", "interner Fehler, AEPH, interne 3V3-Spannung vom CY320_MC2 oberen Grenzwert <20>berschritten", "0" },
{ "0x21EABF", "interner Fehler, AEPH, Interne 3V3-Spannung vom CY320_MC2 unteren Grenzwert unterschritten", "0" },
{ "0x21EAC0", "interner Fehler, AEPH, Interne 1V5-Spannung vom CY320_MC2 oberen Grenzwert <20>berschritten", "0" },
{ "0x21EAC1", "interner Fehler, AEPH, Interne 1V5-Spannung vom CY320_MC2 unteren Grenzwert unterschritten", "0" },
{ "0x21EADA", "interner Fehler, AEPH, Temperatur auf dem Digitalbord am 320_MC0 oberen Grenzwert <20>berschritten", "0" },
{ "0x21EADB", "interner Fehler, AEPH, Temperatur auf dem Digitalbord am 320_MC0 unteren Grenzwert unterschritten", "0" },
{ "0x21EAE0", "interner Fehler, AEPH, Temperatur auf dem Digitalbord am 320_MC2 oberen Grenzwert <20>berschritten", "0" },
{ "0x21EAE1", "interner Fehler, AEPH, Temperatur auf dem Digitalbord am 320_MC2 unteren Grenzwert unterschritten", "0" },
{ "0x21EAE6", "interner Fehler, AEPH, Temperatur <20>ber internen Temperatursensor des MC0 oberen Grenzwert <20>berschritten", "0" },
{ "0x21EAE7", "interner Fehler, AEPH, Temperatur <20>ber internen Temperatursensor des MC0 unteren Grenzwert unterschritten", "0" },
{ "0x21EAE8", "interner Fehler, AEPH, Temperatur <20>ber internen Temperatursensor des MC2 oberen Grenzwert <20>berschritten", "0" },
{ "0x21EAE9", "interner Fehler, AEPH, Temperatur <20>ber internen Temperatursensor des MC2 unteren Grenzwert unterschritten", "0" },
{ "0x21EAF0", "EME, Plausibilisierung der Reglerspannungen", "0" },
{ "0x21EAF1", "EME, Hochvoltzwischenkreis: Spannungsgrenze Speicher <20>berschritten", "0" },
{ "0x21EAF2", "EME, Hochvoltzwischenkreis: Spannungsgrenze Speicher unterschritten", "0" },
{ "0x21EAF3", "EME, Hochvoltzwischenkreis: Lade-Stromgrenze Speicher <20>berschritten", "0" },
{ "0x21EAF4", "EME, Hochvoltzwischenkreis: Entlade-Stromgrenze Speicher <20>berschritten", "0" },
{ "0x21EAF5", "EME, interner Fehler, Momentenpfad: Abweichung Sollmoment Fehler", "0" },
{ "0x21EAF6", "EME, Versorgungsspannung, Wertebereichsverletzung: Unterspannung 12V-Versorgung", "0" },
{ "0x21EAF7", "Sensorfehler, Messwerterfassung, Sensor: Messsignal Motortemperatur 1 Kurzschluss zu GND", "0" },
{ "0x21EAF8", "Sensorfehler, Messwerterfassung, Sensor: Messsignal Motortemperatur 1 Kurzschluss zu UBAT", "0" },
{ "0x21EAF9", "Sensorfehler, Messwerterfassung, Sensor: Messsignal Motortemperatur 2 Kurzschluss zu GND", "0" },
{ "0x21EAFA", "Sensorfehler, Messwerterfassung, Sensor: Messsignal Motortemperatur 2 Kurzschluss zu UBAT", "0" },
{ "0x21EAFB", "Sensorfehler, Messwerterfassung, Sensor: Sensorsignal Pedalwertgeber 1 Kurzschluss zu GND", "0" },
{ "0x21EAFC", "Sensorfehler, Messwerterfassung, Sensor: Sensorsignal Pedalwertgeber 1 Kurzschluss zu UBAT", "0" },
{ "0x21EAFD", "Sensorfehler, Messwerterfassung, Sensor: Sensorsignal Pedalwertgeber 2 Kurzschluss zu GND", "0" },
{ "0x21EAFE", "Sensorfehler, Messwerterfassung, Sensor: Sensorsignal Pedalwertgeber 2 Kurzschluss zu UBAT", "0" },
{ "0x21EAFF", "Sensorfehler, Messwerterfassung, Sensor: Bremsunterdrucksensorsignal Kurzschluss zu GND", "0" },
{ "0x21EB00", "Sensorfehler, Messwerterfassung, Sensor: Bremsunterdrucksensorsignal Kurzschluss zu UBAT", "0" },
{ "0x21EB03", "DCDC, Hardware, Bauteilschutz, Unplausibler DutyCycle in Tiefsetzsteller 1", "0" },
{ "0x21EB04", "DCDC, Hardware, Bauteilschutz, Unplausibler DutyCycle in Tiefsetzsteller 2", "0" },
{ "0x21EB05", "DCDC, Hardware, Bauteilschutz, <20>berschreitung max. LV-Spannung", "0" },
{ "0x21EB06", "DCDC, Hardware, Bauteilschutz, <20>berschreitung max. LV-Strom", "0" },
{ "0x21EB07", "DCDC, Hardware, Bauteilschutz, <20>berschreitung max. Peak-Strom in Tiefsetzsteller Phase 1", "0" },
{ "0x21EB08", "DCDC, Hardware, Bauteilschutz, <20>berschreitung max. Peak-Strom in Tiefsetzsteller Phase 2", "0" },
{ "0x21EB09", "DCDC, Hardware, Bauteilschutz, <20>berschreitung max. Grenzspannung am Tiefsetzstellerausgang", "0" },
{ "0x21EB0A", "DCDC, Hardware, Bauteilschutz, <20>berschreitung max. Peak-Strom im Resonanzkreis", "0" },
{ "0x21EB0B", "DCDC, Hardware, Bauteilschutz, <20>berschreitung max. Temperatur am K<>hlk<6C>rper des Tiefsetzstellers", "0" },
{ "0x21EB0C", "DCDC, Hardware, Bauteilschutz, <20>berschreitung max. Temperatur am K<>hlk<6C>rper des Gegentaktwandlers", "0" },
{ "0x21EB0D", "DCDC, Hardware, Bauteilschutz, <20>berschreitung max. Temperatur am K<>hlk<6C>rper des Gleichrichters", "0" },
{ "0x21EB0E", "DCDC, Hardware, Bauteilschutz, <20>berschreitung der max. Board-Temperatur", "0" },
{ "0x21EB0F", "DCDC, Hardware, Bauteilschutz, Unplausibler Wirkungsgrad", "0" },
{ "0x21EB10", "DCDC, <20>berwachung, Fehler HW-Regler, Sollwerte werden nicht eingeregelt", "0" },
{ "0x21EB11", "DCDC, Hardware, Bauteilschutz, Unplausibles <20>bersetzungsverh<72>ltnis GTW", "0" },
{ "0x21EB12", "DCDC, Hardware, Bauteilschutz, Thermalmodel, JunctionTemp Schalter TS1", "0" },
{ "0x21EB13", "DCDC, Hardware, Bauteilschutz, Thermalmodel, JunctionTemp Schalter TS2", "0" },
{ "0x21EB14", "DCDC, Hardware, Bauteilschutz, Thermalmodel, JunctionTemp Diode TS1", "0" },
{ "0x21EB15", "DCDC, Hardware, Bauteilschutz, Thermalmodel, JunctionTemp Diode TS2", "0" },
{ "0x21EB16", "DCDC, Hardware, Bauteilschutz, Thermalmodel, JunctionTemp Schalter GTW HS1", "0" },
{ "0x21EB17", "DCDC, Hardware, Bauteilschutz, Thermalmodel, JunctionTemp Schalter GTW HS2", "0" },
{ "0x21EB18", "DCDC, Hardware, Bauteilschutz, Thermalmodel, JunctionTemp Schalter GTW LS1", "0" },
{ "0x21EB19", "DCDC, Hardware, Bauteilschutz, Thermalmodel, JunctionTemp Schalter GTW LS2", "0" },
{ "0x21EB1A", "DCDC, Hardware, Bauteilschutz, Thermalmodel, JunctionTemp GR1", "0" },
{ "0x21EB1B", "DCDC, Hardware, Bauteilschutz, Thermalmodel, JunctionTemp Schalter GR2", "0" },
{ "0x21EB1C", "DCDC, Hardware, Bauteilschutz, Unplausibler Resonanzstrom", "0" },
{ "0x21EB1D", "Interne Getriebe<62>berwachung -Parkposition aktuell nicht detektierbar", "0" },
{ "0x21EB1E", "Interne Getriebe<62>berwachung -Parkposition aktuell eingelegt, aktuell kein Fahrerwunsch Parken vorhanden", "0" },
{ "0x21EB1F", "Interne Getriebe<62>berwachung -Parkposition aktuell nicht eingelegt, aktuell Fahrerwunsch Parken vorhanden", "0" },
{ "0x21EB20", "SLE, SW und HW passen nicht zusammen.", "1" },
{ "0x21EB2A", "EME durch EWS gesperrt", "0" },
{ "0x21EB2B", "Interner Fehler, Messwerterfassung, interner Sensor defekt MC0", "0" },
{ "0x21EB2C", "Interner Fehler, Messwerterfassung, interner Sensor defekt MC2", "0" },
{ "0x21EB2D", "Messwerterfassung, Hardwarekalibrationswerte, eine bzw. mehrere Werte fehlen auf dem MC0", "0" },
{ "0x21EB2E", "Messwerterfassung, Hardwarekalibrationswerte, eine bzw. mehrere Werte fehlen auf dem MC2", "0" },
{ "0x21EB2F", "DCDC, SPI Kommunikation, DCDC- nach Controller-Board fehlerhaft", "0" },
{ "0x21EB30", "DCDC, SPI Kommunikation, Controller- nach DCDC-Board fehlerhaft", "0" },
{ "0x21EB31", "SLE, SPI Kommunikation, Lader- nach Controller-Board fehlerhaft", "0" },
{ "0x21EB32", "SLE, SPI Kommunikation, Controller- nach Lader-Board fehlerhaft", "0" },
{ "0x21EB33", "interner Fehler, FUSI, aktive Entladung-Fehler", "0" },
{ "0x21EB34", "Qualfierueberwachung, Signalausfall CAN von eDME", "0" },
{ "0x21EB35", "Qualfierueberwachung, Signalausfall CAN von SME", "0" },
{ "0x21EB36", "Qualfierueberwachung, Signalausfall Intern", "0" },
{ "0x21EB37", "Qualfierueberwachung, Signalausfall Resolver", "0" },
{ "0x21EB38", "Parksperre, Strommittelwert Kabel PS-Aktuator zu hoch", "0" },
{ "0x21EB3B", "HW-AKS aktiv, Angefordert durch FUSI, BTS oder Hardwareschaltung", "1" },
{ "0x21EB3C", "HW-Freilauf aktiv, Angefordert durch FUSI, BTS oder Hardwareschaltung", "1" },
{ "0x21EB3D", "interne Fehler, Inkompatibilit<69>t zwischen TriCore/PIC Softwareversionen", "0" },
{ "0x21EB3E", "E-Maschine Resolverabgleich nicht durchgef<65>hrt oder Rotorlagesensor-Offset nicht im Toleranzband.", "0" },
{ "0x21EB40", "Interner Fehler, HVIL, KS Ausgang gegen Masse oder KS Eingang gegen B+", "0" },
{ "0x21EB41", "Interner Fehler, HVIL, KS Ausgang gegen B+ oder KS Eingang gegen Masse", "0" },
{ "0x21EB42", "Interner Fehler, HVIL, Kurzschluss Eingang gegen Ausgang oder Leitung offen", "0" },
{ "0x21EB43", "Interner Fehler, HVIL, fehlerhaftes Signal", "0" },
{ "0x21EB44", "DCDC, Hardware, Bauteilschutz, GateTreiberVersorgung", "0" },
{ "0x21EB45", "Inverter, Temperatur ung<6E>ltig, nicht kompensierbar", "0" },
{ "0x21EB46", "Inverter, Temperatur ung<6E>ltig, kompensierbar", "0" },
{ "0x21EB47", "Inverter, Dauerhafte <20>bertemperatur IGBT/Diode", "0" },
{ "0x21EB48", "Inverter, Erh<72>hte Temperaturspreizung Platine zu IGBT/Diode", "0" },
{ "0x21EB49", "Inverter, Dauerhafte <20>bertemperatur NTC", "0" },
{ "0x21EB4A", "Inverter, Dauerhafte <20>bertemperatur K<>hlmittel", "0" },
{ "0x21EB4B", "SLE, <20>berstromerkennung Hochsetzer, max. Wert <20>berschritten", "0" },
{ "0x21EB4C", "SLE, <20>berstromerkennung Trafo, max. Wert <20>berschritten", "0" },
{ "0x21EB4D", "SLE, <20>berspannungserkennung Hochsetzer, max. Wert <20>berschritten", "0" },
{ "0x21EB4E", "SLE, <20>berspannungserkennung Zwischenkreis, max. Wert <20>berschritten", "0" },
{ "0x21EB4F", "SLE, Unterspannungserkennung Zwischenkreis, min. Wert unterschritten", "0" },
{ "0x21EB50", "SLE, <20>bertemperaturerkennung K<>hlk<6C>rper Hochsetzer, max. Wert <20>berschritten", "0" },
{ "0x21EB51", "SLE, <20>bertemperaturerkennung K<>hlk<6C>rper Gegentaktwandler, max. Wert <20>berschritten", "0" },
{ "0x21EB52", "SLE, <20>bertemperaturerkennung K<>hlk<6C>rper Gleichrichter, max. Wert <20>berschritten", "0" },
{ "0x21EB53", "SLE, <20>bertemperaturerkennung Sperrschicht MOSFET Hochsetzer, max. Wert <20>berschritten", "0" },
{ "0x21EB54", "SLE, <20>bertemperaturerkennung Sperrschicht Diode Hochsetzer, max. Wert <20>berschritten", "0" },
{ "0x21EB55", "SLE, <20>bertemperaturerkennung Sperrschicht MOSFET Zweig 1 Gegentaktwandler, max. Wert <20>berschritten", "0" },
{ "0x21EB56", "SLE, <20>bertemperaturerkennung Sperrschicht MOSFET Zweig 2 Gegentaktwandler, max. Wert <20>berschritten", "0" },
{ "0x21EB57", "SLE, <20>bertemperaturerkennung Sperrschicht Diode Gleichrichter, max. Wert <20>berschritten", "0" },
{ "0x21EB58", "SLE, <20>berspannungserkennung Eingangswechselspannung, max. Wert <20>berschritten", "0" },
{ "0x21EB59", "SLE, <20>bertemperaturerkennung Bord, max. Wert <20>berschritten", "0" },
{ "0x21EB5A", "SLE, Duty-Fehler Hochsetzer, von Bauteilschutz", "0" },
{ "0x21EB5B", "SLE, SPI-Fehler, von Bauteilschutz", "0" },
{ "0x21EB5C", "Interner Fehler, Freilauf Modus aktiv", "0" },
{ "0x21EB5D", "Interner Fehler, Freilauf Modus und 6km/h <20>berschritten", "0" },
{ "0x21EB5E", "FUSI, Radblockiererkennung: Anforderung AKS aktiv", "0" },
{ "0x21EB5F", "Leistungselektronik Pulswechselrichter, Stromregler verhindert Betrieb", "0" },
{ "0x21EB62", "FUSI, Nullmomentenplausibilisierung aktiv", "0" },
{ "0x21EB63", "Inverter, Fehlerhafter positiver Id-Strom erkannt", "0" },
{ "0x21EB64", "Inverter, DC <20>berstrom erkannt", "0" },
{ "0x21EB65", "Interner Fehler, Reset auf MC0", "0" },
{ "0x21EB66", "Interner Fehler, Reset auf MC2", "0" },
{ "0x21EB67", "DCDC, Bauteilschutz, <20>berspannung U_LV redundante Messung", "0" },
{ "0x21EB68", "DCDC, Bauteilschutz, <20>berstrom I_LV redundante Messung", "0" },
{ "0x21EB69", "interner Fehler, AEPH, Temperatur auf dem Digitalboard, Boardmitte oberen Grenzwert <20>berschritten", "0" },
{ "0x21EB6A", "interner Fehler, AEPH, Temperatur auf dem Digitalboard, Boardmitte unteren Grenzwert unterschritten", "0" },
{ "0x21EB6B", "interner Fehler, HVSM, Zwischenkreisspannung oberen Grenzwert <20>berschritten", "0" },
{ "0x21EB6C", "interner Fehler, HVSM, Zwischenkreisspannung unteren Grenzwert unterschritten", "0" },
{ "0x21EB6D", "FUSI, CPLD AKS Anforderung, CPLD FuSi/BTS Sammelfehler", "0" },
{ "0x21EB6E", "Funktionssicherheitsmanager, DCDC Gleichrichterabschaltung, R<>ckmeldung unplausibel", "0" },
{ "0x21EB6F", "Messwerterfassung, Hardwarekalibrationswerte, CRC Fehler MC0", "0" },
{ "0x21EB70", "Messwerterfassung, Hardwarekalibrationswerte, CRC Fehler MC2", "0" },
{ "0x21EB71", "Hochvoltsicherheitsmanager, HW AKS aktiv, Anforderer: Crash Hardwarepin", "0" },
{ "0x21EB72", "Hochvoltsicherheitsmanager, HW AKS aktiv, Anforderer: Crash Airbag SG MRS5", "0" },
{ "0x21EB73", "Hochvoltsicherheitsmanager, HW AKS aktiv, Anforderer: Dual Port RAM defekt", "0" },
{ "0x21EB74", "Hochvoltsicherheitsmanager, HW AKS aktiv, Anforderer: eDME", "0" },
{ "0x21EB75", "Sensorfehler, Messwerterfassung, Resolver Winkel", "0" },
{ "0x21EB76", "Sensorfehler, Messwerterfassung, Resolver Drehzahl", "0" },
{ "0x21EB77", "DCDC, Unzul<75>ssige MC6 Software Version", "0" },
{ "0x21EB78", "Inverter, Dauerhafte <20>bertemperatur am Gatetrieber", "0" },
{ "0x21EB79", "Inverter, <20>bertragener K<>hlmittelvolumenstrom unterhalb zul<75>ssiger Schwelle", "0" },
{ "0x21EB7A", "Resolver, Fehler Plausibilisierung Winkel", "0" },
{ "0x21EB7B", "Fehler bei der Dignose des Bremspedals", "0" },
{ "0x21EB7C", "CCM 848 (China); Fehler aufgrund zu hoher Temperatur der Antriebs-E-Maschine", "0" },
{ "0x21EB7D", "DCDC deaktiviert aufgrund zu hohen Stroms", "0" },
{ "0x21EB7E", "DCDC deaktiviert aufgrund Hardwarefehler", "0" },
{ "0x21EB7F", "DCDC deaktiviert aufgrund zu hoher Temperatur", "0" },
{ "0x21EB80", "DCDC deaktiviert aufgrund <20>berspannung", "0" },
{ "0x21EB81", "Leistungsreduzierung Antrieb Stufe 1", "0" },
{ "0x21EB82", "Leistungsreduzierung Antrieb Stufe 2", "0" },
{ "0x21EB83", "Fehler Antriebs-E-Maschine; Maximale Drehzahl <20>berschritten", "0" },
{ "0x21EB84", "Batterie Service Request", "0" },
{ "0x21EB85", "Batterie: 0-Stromanforderung", "0" },
{ "0x21EB86", "Batterie: Langsames <20>ffnen der Sch<63>tze", "0" },
{ "0x21EB87", "Batterie: Schnelles <20>ffnen der Sch<63>tze", "0" },
{ "0x21EB88", "Fehler im K<>hlsystem der Hochvoltbatterie", "0" },
{ "0x21EB89", "Aktiver Kurzschluss, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB8A", "Freilauf, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB8B", "0-Momentenanforderung, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB8C", "Notlauf-Betrieb, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB8D", "Batterie grenzen <20>berschritten. Erkennung, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB8E", "Momentenabweichung, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB8F", "Temperaturfehler, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB90", "Interlockfehler, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB91", "Wechselstromfehler, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB92", "Fehler Rotolagesensor, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB93", "CAN-Signalfehler, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB94", "Interner Signalfehler, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB95", "Wegfahrsperre Fehler, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB96", "Hardwarefehler, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB97", "Temperaturfehler Inverter, verbrennungsmotornahe HV E-Maschine", "0" },
{ "0x21EB98", "Aktiver Kurzschluss, verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EB99", "Freilauf, verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EB9A", "0-Momentenanforderung, verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EB9B", "Notlauf-Betrieb, verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EB9C", "Batterie grenzen <20>berschritten. Erkennung, verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EB9D", "Momentenabweichung, verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EB9E", "Temperaturfehler, verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EB9F", "Interlockfehler , verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EBA0", "Wechselstromfehler , verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EBA1", "Fehler Rotolagesensor , verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EBA2", "CAN-Signalfehler , verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EBA3", "Interner Signalfehler , verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EBA4", "Wegfahrsperre Fehler , verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EBA5", "Hardwarefehler , verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EBA6", "Temperaturfehler Inverter , verbrennungsmotorferne/ Traktions- HV E-Maschine", "0" },
{ "0x21EBA7", "Hochvoltsicherheitsmanager, HW AKS aktiv, Anforderer: FUSI L<>ngsdynamik", "0" },
{ "0x21EBA8", "Hochvoltsicherheitsmanager, HW AKS aktiv, Anforderer: Phasen<65>berstrom", "0" },
{ "0x21EBA9", "Sensorfehler, Messwerterfassung, Sensor: Messsignal Motortemperatur Drahtspulenende Kurzschluss zu GND", "0" },
{ "0x21EBAA", "Sensorfehler, Messwerterfassung, Sensor: Messsignal Motortemperatur Drahtspulenende Kurzschluss zu UBAT", "0" },
{ "0x21EBAB", "Sensorfehler, Messwerterfassung, Sensor: Messsignal Motortemperatur Stator Kurzschluss zu GND", "0" },
{ "0x21EBAC", "Sensorfehler, Messwerterfassung, Sensor: Messsignal Motortemperatur Stator Kurzschluss zu UBAT", "0" },
{ "0x21EE0B", "HV-Powermanagement: HV-batterieloser Betrieb wird verhindert aufgrund Sch<63>tzkleber", "0" },
{ "0x21EE0C", "HV-Powermanagement: wichtige Signale der Antriebselektronik ung<6E>ltig oder nicht empfangen", "0" },
{ "0x21EE0D", "HV-Powermanagement: wichtige Signale der HV-Batterie ung<6E>ltig oder nicht empfangen", "0" },
{ "0x21EE80", "EME, Stromplausibilisierung der drei Phasen: Summe der Phasenstr<74>me au<61>erhalb des erlaubten Bereichs", "0" },
{ "0x21EEC5", "Externer Temperatursensor E-Maschine Signal Wertebereichsverletzung : Untere Schwelle", "0" },
{ "0x21EEC6", "Externer Temperatursensor E-Maschine Signal Wertebereichsverletzung: Obere Schwelle", "0" },
{ "0x21EF09", "Interne EME-Temperatur Leistungselektronik Pulswechselrichter: Obere Temperaturschwelle <20>berschritten", "0" },
{ "0x21EF10", "EME, Stromsensor Phase U: <20>berstrom oder Sensor defekt", "0" },
{ "0x21EF18", "EME, Stromsemnsor Phase V: <20>berstrom oder Sensor defekt", "0" },
{ "0x21EF20", "EME, Stromsemnsor Phase W: <20>berstrom oder Sensor defekt", "0" },
{ "0x21EF41", "EME, E-Maschinenregelung, E-Maschine: Temperatur <20>ber 1. Schwelle", "0" },
{ "0x21EF42", "EME, E-Maschinenregelung, E-Maschine: Temperatur <20>ber 2. Schwelle", "0" },
{ "0x21EF43", "EME, E-Maschinenregelung, E-Maschine: <20>berdrehzahl erkannt", "0" },
{ "0x21EF44", "Externer Temperatursensor2 E-Maschine Signal Wertebereichsverletzung : Untere Schwelle", "0" },
{ "0x21EF45", "Externer Temperatursensor2 E-Maschine Signal Wertebereichsverletzung: Obere Schwelle", "0" },
{ "0x21EF46", "EME, E-Maschinenregelung, E-Maschine: Temperatursensor2 <20>ber 2. Schwelle", "0" },
{ "0x21EF55", "HV-Powermanagement: Unterversorgung 12V-Bordnetz (Ladekontrollleuchte aktiv)", "1" },
{ "0x21EF90", "Externer Crashsensor <20>ber CAN: Crash detektiert (wird von BMW-Funktion HVPM eingetragen)", "1" },
{ "0x21EF96", "EME, HV-Kommunikation: Sch<63>tzkleber 2 von SME <20>ber CAN gemeldet (B_schuetzkleber_2)", "1" },
{ "0x21EFAA", "HV-Powermanagement: Anforderung 12V-Verbraucherreduzierung an AEP", "0" },
{ "0x21EFAE", "HV-Powermanagement: HV-Power-Down aufgrund niedrigem Ladezustand HV-Batterie", "0" },
{ "0x21EFD8", "HV-Powermanagement: keine HV-Freigabe trotz Anforderung", "1" },
{ "0x21EFEF", "HV-Powermanagement: Systembedingte Degradation des DCDC-Wandlers", "1" },
{ "0xCF840A", "FA-CAN Control Module Bus OFF", "0" },
{ "0xCF8486", "A-CAN Control Module Bus OFF", "0" },
{ "0xCF8BFF", "Dummy-Fehlerspeichereintrag im Netzwerkfehlerbereich nur f<>r Testzwecke", "1" },
{ "0xCF9402", "A-CAN, Botschaft ausgefallenl DEGR_MOT_TRCT", "1" },
{ "0xCF9403", "A-CAN, Botschaft ausgefallen ENERG_COSP_ERR_ST_KLE", "1" },
{ "0xCF9404", "A-CAN, Botschaft ausgefallen KLEMMEN", "1" },
{ "0xCF9405", "A-CAN, Botschaft ausgefallen LIM_CHG_DCHG_HVSTO", "1" },
{ "0xCF9406", "A-CAN, Botschaft ausgefallen LIM_KLE", "1" },
{ "0xCF9407", "A-CAN, Botschaft ausgefallen ST_CHG_HVSTO_3", "1" },
{ "0xCF9411", "A-CAN, Botschaft ausgefallen SPEC_MOT_TRCT", "1" },
{ "0xCF9413", "A-CAN, Botschaft ausgefallen ST_HYB_2", "1" },
{ "0xCF9414", "A-CAN, Botschaft ausgefallen STAT_HVSTO_2", "1" },
{ "0xCF9415", "A-CAN, Botschaft ausgefallen AVL_DT_KLE", "1" },
{ "0xCF9416", "A-CAN, Botschaft ausgefallen AVL_DT_KLE_LT", "1" },
{ "0xCF9419", "A-CAN, CRC Fehler, SPEC_MOT_TRCT", "1" },
{ "0xCF941A", "A-CAN, Alive-Counter Fehler SPEC-MOT_TRCT", "1" },
{ "0xCF941D", "A-CAN, CAN_Signal ung<6E>ltig RQ_ELUP, Botschaft ELUP_SPEC", "1" },
{ "0xCF941F", "A-CAN, Botschaft ausgefallen CTR_CRASH_SWO_EKP", "1" },
{ "0xCF9420", "A-CAN, Botschaft ausgefallen FZZSTD", "1" },
{ "0xCF9421", "A-CAN, Botschaft ausgefallen KILOMETERSTAND", "1" },
{ "0xCF9422", "A-CAN, Botschaft ausgefallen RELATIVZEIT", "1" },
{ "0xCF9423", "A-CAN, Botschaft ausgefallen V_VEH", "1" },
{ "0xCF9424", "A-CAN, CRC Fehler V_VEH", "1" },
{ "0xCF9425", "A-CAN, Alive-Counter Fehler V_VEH", "1" },
{ "0xCF9426", "A-CAN, Botschaft ausgefallen FAHRGESTELLNUMMER", "1" },
{ "0xCF942A", "A-CAN, Botschaft ausgefallen A_TEMP", "1" },
{ "0xCF942B", "A-CAN, Botschaft ausgefallen AVL_DT_SRT_MOT_1", "1" },
{ "0xCF942C", "A-CAN, Botschaft ausgefallen CTR_PRTNT", "1" },
{ "0xCF942D", "A-CAN, Botschaft ausgefallen DT_EL_GEY", "1" },
{ "0xCF942E", "A-CAN, Botschaft ausgefallen DT_HVSTO", "1" },
{ "0xCF942F", "A-CAN, Botschaft ausgefallen DT_PT_1", "1" },
{ "0xCF9430", "A-CAN, Botschaft ausgefallen DT_PT_2", "1" },
{ "0xCF9431", "A-CAN, Botschaft ausgefallen DT_PT_3", "1" },
{ "0xCF9432", "A-CAN, Botschaft ausgefallen FRC_OPRNG_MOT_1", "1" },
{ "0xCF9433", "A-CAN, Botschaft ausgefallen HYB_SPEC", "1" },
{ "0xCF9434", "A-CAN, Botschaft ausgefallen IDENT_HVSTO_0R", "1" },
{ "0xCF9435", "A-CAN, Botschaft ausgefallen INFO_MOT_1", "1" },
{ "0xCF9436", "A-CAN, Botschaft ausgefallen MOD_VC", "1" },
{ "0xCF9437", "A-CAN, Botschaft ausgefallen OBD_INQY_LIM_TORQ", "1" },
{ "0xCF9438", "A-CAN, Botschaft ausgefallen PWMG_LV", "1" },
{ "0xCF9439", "A-CAN, Botschaft ausgefallen RLS_COOL_HVSTO", "1" },
{ "0xCF943A", "A-CAN, Botschaft ausgefallen RQ_RPM_MOT_2", "1" },
{ "0xCF943B", "A-CAN, Botschaft ausgefallen RQ_TORQ_OSTR", "1" },
{ "0xCF943C", "A-CAN, Botschaft ausgefallen ST_CHG_HVSTO_2", "1" },
{ "0xCF943D", "A-CAN, Botschaft ausgefallen ST_DT_MOT_1", "1" },
{ "0xCF943E", "A-CAN, Botschaft ausgefallen ST_GWS", "1" },
{ "0xCF943F", "A-CAN, CRC Fehler ST_GWS_CRC", "1" },
{ "0xCF9440", "A-CAN, Alive-Counter Fehler ST_GWS_ALV", "1" },
{ "0xCF9441", "A-CAN, Botschaft ausgefallen ST_HT_HVSTO", "1" },
{ "0xCF9442", "A-CAN, Botschaft ausgefallen ST_HVSTO_1", "1" },
{ "0xCF9443", "A-CAN, Botschaft ausgefallen ST_INFO_CENG", "1" },
{ "0xCF9444", "A-CAN, Botschaft ausgefallen ST_STA_PWR_DRV", "1" },
{ "0xCF9445", "A-CAN, Botschaft ausgefallen SU_SW_DRDY", "1" },
{ "0xCF9446", "A-CAN, Botschaft ausgefallen TORQ_CRSH_1", "1" },
{ "0xCF9447", "A-CAN, Botschaft ausgefallen UHRZEIT_DATUM", "1" },
{ "0xCF9448", "FA-CAN, Botschaft ausgefallen A_TEMP", "1" },
{ "0xCF9449", "FA-CAN, Botschaft ausgefallen ACLNX_MASSCNTR", "1" },
{ "0xCF944A", "FA-CAN, Botschaft ausgefallen ANG_ACPD", "1" },
{ "0xCF944B", "FA-CAN, Botschaft ausgefallen AVL_BRTORQ_SUM", "1" },
{ "0xCF944C", "FA-CAN, Botschaft ausgefallen AVL_DT_LT_CENG_REX", "1" },
{ "0xCF944D", "FA-CAN, Botschaft ausgefallen AVL_RPM_WHL_UPRT", "1" },
{ "0xCF944E", "FA-CAN, Botschaft ausgefallen FLLUPT_GPWSUP", "1" },
{ "0xCF944F", "FA-CAN, Botschaft ausgefallen KLEMMEN", "1" },
{ "0xCF9450", "FA-CAN, Botschaft ausgefallen RQ_2_WMOM_PT_SUM_DRS", "1" },
{ "0xCF9451", "FA-CAN, Botschaft ausgefallen RQ_AIC_1", "1" },
{ "0xCF9452", "FA-CAN, Botschaft ausgefallen RQ_AIC", "1" },
{ "0xCF9453", "FA-CAN, Botschaft ausgefallen ST_BLT_CT_SOCCU", "1" },
{ "0xCF9454", "FA-CAN, Botschaft ausgefallen ST_CDC_CHGNG_1", "1" },
{ "0xCF9455", "FA-CAN, Botschaft ausgefallen ST_CDC_CHGNG_2", "1" },
{ "0xCF9456", "FA-CAN, Botschaft ausgefallen ST_CDC_CHGNG_3", "1" },
{ "0xCF9457", "FA-CAN, Botschaft ausgefallen ST_CHGINTF", "1" },
{ "0xCF9458", "FA-CAN, Botschaft ausgefallen ST_STAB_DSC", "1" },
{ "0xCF9459", "FA-CAN, Botschaft ausgefallen ST_VHSS", "1" },
{ "0xCF945A", "FA-CAN, CRC Fehler ST_VHSS", "1" },
{ "0xCF945B", "FA-CAN, Alive-Counter Fehler ST_VHSS", "1" },
{ "0xCF945C", "FA-CAN, Botschaft ausgefallen STAT_DS_VRFD", "1" },
{ "0xCF945D", "FA-CAN, Botschaft ausgefallen STAT_ENG_STA_AUTO", "1" },
{ "0xCF945E", "FA-CAN, Botschaft ausgefallen TS_CALL_ST", "1" },
{ "0xCF945F", "FA-CAN, Botschaft ausgefallen U_BN", "1" },
{ "0xCF9460", "FA-CAN, Botschaft ausgefallen UHRZEIT_DATUM", "1" },
{ "0xCF9461", "FA-CAN, Botschaft ausgefallen WMOM_DRV_5", "1" },
{ "0xFFFFFF", "unbekannter Fehlerort", "0" }
};
// Bitte Flags ausw<73>hlen!
table FDetailStruktur[2][]={
{ "NAME", "TYP" },
{ "F_UWB_ERW", "ja" },
{ "SAE_CODE", "nein" },
{ "F_HLZ", "ja" },
{ "F_SEVERITY", "nein" },
{ "F_UWB_SATZ", "2" },
{ "F_HLZ_VIEW", "ja" }
};
// In dieser Tabelle werden die m<>glichen Bereiche f<>r Fehlerorte definiert.
table DTCBereiche[4][]={
{ "DTC-TYP", "MINIMALWERT", "MAXIMALWERT", "BESCHREIBUNG" },
{ "AllgemeinerDTC", "020000", "02FFFF", "Die zul<75>ssigen Bereiche sind f<>r jedes Steuerger<65>t festgelegt. Es k<>nnen mehrere g<>ltige Bereiche (Kacheln) definiert werden." },
{ "SystembusDTC", "CF8473", "CF847C", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SystembusDTC", "930030", "930055", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SystembusDTC", "CF850B", "CF8514", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SystembusDTC", "930000", "930011", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SystembusDTC", "CF8469", "CF8472", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SystembusDTC", "CF8401", "CF840A", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SystembusDTC", "CF847D", "CF8486", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SystembusDTC", "CF8487", "CF848F", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SystembusDTC", "CF843F", "CF8449", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SystembusDTC", "CF8415", "CF841E", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SystembusDTC", "CF8501", "CF850A", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SystembusDTC", "CF840B", "CF8414", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SystembusDTC", "CF845F", "CF8468", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SystembusDTC", "CF841F", "CF843E", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SubbusDTC", "CF8C00", "CF93FF", "Zul<75>ssiger Bereich wird mittels Formel berechnet. Enth<74>lt physikalische Fehler bzw. Protokollfehler des Systembusses." },
{ "SignalDTC", "CF9400", "CFC3FF", "Ist aus einem vorgegebenen Offset-Bereich frei w<>hlbar. Enth<74>lt Signalfehler, die SG-spezifisch sind." },
{ "SignalDTC", "CF9400", "CFC3FF", "Ist aus einem vorgegebenen Offset-Bereich frei w<>hlbar. Enth<74>lt Signalfehler, die SG-spezifisch sind." },
{ "SignalDTC", "CF8BFF", "CF8BFF", "Ist aus einem vorgegebenen Offset-Bereich frei w<>hlbar. Enth<74>lt Signalfehler, die SG-spezifisch sind." },
{ "KomponentenDTC", "21EE00", "21EFFF", "Die zul<75>ssigen Bereiche sind f<>r jedes Steuerger<65>t festgelegt. Es k<>nnen mehrere g<>ltige Bereiche (Kacheln) definiert werden." },
{ "KomponentenDTC", "21EA00", "21EBFF", "Die zul<75>ssigen Bereiche sind f<>r jedes Steuerger<65>t festgelegt. Es k<>nnen mehrere g<>ltige Bereiche (Kacheln) definiert werden." }
};
// Tabelle ausf<73>llen, wenn F_UWB_ERW = ja gesetzt!
table FUmweltTexte[9][]={
{ "UWNR", "UWTEXT", "UW_EINH", "L/H", "UWTYP", "NAME", "MUL", "DIV", "ADD" },
{ "0x170C", "UBAT", "mV", "High", "unsigned int", "-", "1.0", "1.0", "0.0" },
{ "0x4100", "UWB_AE_EM_DREHZAL", "1/min", "High", "unsigned int", "-", "0.5", "1.0", "20000.0" },
{ "0x4101", "UWB_AE_PS_AKTUELLER_BEFEHL", "-", "High", "unsigned char", "-", "1.0", "1.0", "0.0" },
{ "0x4102", "UWB_AE_PS_STROM_HBRUECKE", "mA", "High", "signed int", "-", "1.0", "1.0", "0.0" },
{ "0x4103", "UWB_AE_PS_POS_SENS1", "%", "High", "unsigned char", "-", "1.0", "1.0", "0.0" },
{ "0x4104", "UWB_AE_PS_POS_SENS2", "%", "High", "unsigned char", "-", "1.0", "1.0", "0.0" },
{ "0x4105", "UWB_AE_PS_SPG_SENS1", "mV", "High", "unsigned char", "-", "20.0", "1.0", "0.0" },
{ "0x4107", "UWB_AE_EM_TEMPERATUR", "<22>C", "High", "unsigned char", "-", "1.0", "1.0", "-40.0" },
{ "0x4108", "UWB_AE_INV_TEMP_U", "<22>C", "High", "unsigned char", "-", "1.0", "1.0", "-40.0" },
{ "0x4109", "UWB_AE_INV_TEMP_V", "<22>C", "High", "unsigned char", "-", "1.0", "1.0", "-40.0" },
{ "0x410A", "UWB_AE_INV_TEMP_W", "<22>C", "High", "unsigned char", "-", "1.0", "1.0", "-40.0" },
{ "0x410B", "UWB_AE_EM_MD_SOLL", "Nm", "High", "unsigned int", "-", "0.5", "1.0", "-1023.5" }
};
// In diese Tabelle alle Fehlerorte eintragen!
table IOrtTexte[3][]={
{ "ORT", "ORTTEXT", "EREIGNIS_DTC" },
{ "0x1A0043", "Interner Fehler, Messwerterfassung, Sensor: Temperatur SLE PFC fehlerhaft", "0" },
{ "0x1A0015", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Digitalboard CY320_MC2 fehlerhaft", "0" },
{ "0x1A0016", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Phasenstromsensoren Temperaturkompensation des gemessenen Stroms MC2 fehlerhaft", "0" },
{ "0x1A003F", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Digitalboard fehlerhaft", "0" },
{ "0x1A0064", "Qualifierueberwachung, CAN von eDME, Signalausfall 2", "0" },
{ "0x1A0045", "Interner Fehler, Messwerterfassung, Sensor: SLE PFC-Strom 2 fehlerhaft", "0" },
{ "0x1A007E", "Checkcontrol 394: Eventuell Wahlhebel gest<73>rt!", "0" },
{ "0x1A002D", "Interner Fehler, Messwerterfassung, Sensor: R<>ckmessung Spannungsversorgung Pedalwergeber2 fehlerhaft", "0" },
{ "0x1A0013", "Interner Fehler, Messwerterfassung, Sensor: Analogsignal Spannungs<67>berwachung interne 3.3V CY320_MC0 fehlerhaft", "0" },
{ "0x1A0053", "FUSI, Radblockiererkennung: Anforderung 0 Nm aktiv", "0" },
{ "0x1A000D", "Interner Fehler, Messwerterfassung, Sensor: Phasenstrom Inverter Phase W fehlerhaft", "0" },
{ "0x1A000F", "Interner Fehler, Messwerterfassung, Sensor: Versorgungsspannung Inverter Gatetreiber Phase V fehlerhaft", "0" },
{ "0x1A040F", "Interner Fehler, Messwerterfassung, Sensor: CY320 MC2 Versorgungsspannung 3 fehlerhaft", "0" },
{ "0x1A001B", "Interner Fehler, Messwerterfassung, Sensor: Variantenerkennung Inverter fehlerhaft", "0" },
{ "0x1A005B", "CPLD AKS Anforderung mit Signal /I_S_AKS_REQ_MC0", "0" },
{ "0x1A041D", "Interner Fehler, Messwerterfassung, Sensor: gefilterte SLE LLC Transformator Temperatur fehlerhaft", "0" },
{ "0x1A0018", "Interner Fehler, Messwerterfassung, Sensor: Phasenstrom Inverter Phase U (redundant) fehlerhaft", "0" },
{ "0x1A0042", "Interner Fehler, Messwerterfassung, Sensor: Temperatur SLE Gleichrichter fehlerhaft", "0" },
{ "0x1A0058", "Zwischenkreis Br<42>ckenkurzschluss <20>ber CPLD ermittelt", "0" },
{ "0xC90402", "Fehler konnte nach maximaler Anzahl von Versuchen nicht gesendet werden", "1" },
{ "0x1A0047", "Interner Fehler, Messwerterfassung, Sensor: verst<73>rkter SLE PFC-Summenstrom fehlerhaft", "0" },
{ "0x1A002B", "Interner Fehler, Messwerterfassung, Sensor: Sensorsignal Pedalwertgeber 2 fehlerhaft", "0" },
{ "0x1A000B", "Interner Fehler, Messwerterfassung, Sensor: Phasenstrom Inverter Phase U fehlerhaft", "0" },
{ "0x1A0010", "Interner Fehler, Messwerterfassung, Sensor: Versorgungsspannung Inverter Gatetreiber Phase W fehlerhaft", "0" },
{ "0x1A0039", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Digitalboard CY320_MC0 fehlerhaft", "0" },
{ "0x002001", "NVM_E_WRITE_FAILED", "0" },
{ "0x1A000E", "Interner Fehler, Messwerterfassung, Sensor: Versorgungsspannung Inverter Gatetreiber Phase U fehlerhaft", "0" },
{ "0x1A001C", "Interner Fehler, Messwerterfassung, Sensor: Variantenerkennung Steuer-/Ladeelektronik fehlerhaft", "0" },
{ "0x1A0041", "Interner Fehler, Messwerterfassung, Sensor: Temperatur SLE Gegentaktwandler fehlerhaft", "0" },
{ "0x1A005C", "CPLD AKS Anforderung mit Signal /I_S_CRASH von ACSM und Auswerteschaltung", "0" },
{ "0x1A002F", "Interner Fehler, Messwerterfassung, Sensor: Strommessung Parksperre Halbbr<62>cke 2 fehlerhaft", "0" },
{ "0x1A003C", "Interner Fehler, Messwerterfassung, Sensor: Variantenerkennung Controllerboard fehlerhaft", "0" },
{ "0x1A002E", "Interner Fehler, Messwerterfassung, Sensor: Strommessung Parksperre Halbbr<62>cke 1 fehlerhaft", "0" },
{ "0x002010", "NVM_E_WRONG_CONFIG_ID", "0" },
{ "0x1A0044", "Interner Fehler, Messwerterfassung, Sensor: SLE PFC-Strom 1 fehlerhaft", "0" },
{ "0x1A0063", "Qualifierueberwachung, CAN von eDME, Signalausfall 1", "0" },
{ "0x1A040C", "Interner Fehler, Messwerterfassung, Sensor: Zweiganggetriebe Aktuatorstrom fehlerhaft", "0" },
{ "0x1A0023", "Interner Fehler, Messwerterfassung, Sensor: Temperatur DC/DC Board fehlerhaft", "0" },
{ "0x1A0004", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Inverter Phase V fehlerhaft", "0" },
{ "0x1A000A", "Interner Fehler, Messwerterfassung, Sensor: DC Strom Inverter fehlerhaft", "0" },
{ "0x1A002A", "Interner Fehler, Messwerterfassung, Sensor: Sensorsignal Pedalwertgeber 1 fehlerhaft", "0" },
{ "0x1A040D", "Interner Fehler, Messwerterfassung, Sensor: CY320 MC2 Versorgungsspannung 1 fehlerhaft", "0" },
{ "0x1A0030", "Interner Fehler, Messwerterfassung, Sensor: Stromr<6D>ckmessung Parksperrenaktuator Ansteuerung fehlerhaft", "0" },
{ "0x1A0054", "Diagnose, AKS via Diagnosejob angefordert", "0" },
{ "0x1A0014", "Interner Fehler, Messwerterfassung, Sensor: Analogsignal Spannungs<67>berwachung interne 1.5V CY320_MC0 fehlerhaft", "0" },
{ "0x1A002C", "Interner Fehler, Messwerterfassung, Sensor: R<>ckmessung Spannungsversorgung Pedalwergeber1 fehlerhaft", "0" },
{ "0x1A0020", "Interner Fehler, Messwerterfassung, Sensor: Temperatur DC/DC Gegentaktwandler fehlerhaft", "0" },
{ "0x1A0060", "CPLD AKS Anforderung mit Signal /MC2_VOLT_FAIL", "0" },
{ "0x1A0001", "Interner Fehler, Messwerterfassung, Sensor: Messsignal Motortemperatur 1 fehlerhaft", "0" },
{ "0x1A0412", "Interner Fehler, Messwerterfassung, Sensor: CY320 MC0 Versorgungsspannung 3 fehlerhaft", "0" },
{ "0x1A0415", "Interner Fehler, Messwerterfassung, Sensor: 2.5V Spannungseingang Dcdc Board fehlerhaft", "0" },
{ "0xE89400", "Botschaft (Fahrzeugzustand, 0x3A0) fehlt", "1" },
{ "0x1A004F", "Interner Fehler, Messwerterfassung, Sensor: DC/DC-Strom 1 Trafo fehlerhaft", "0" },
{ "0x1A006E", "Ebene2 Fehler PS, Strom Aktuator in Ruhe zu hoch", "0" },
{ "0x1A0029", "Interner Fehler, Messwerterfassung, Sensor: analoger Messeingang COS-Resolversignal", "0" },
{ "0x1A003D", "Interner Fehler, Messwerterfassung, Sensor: CPLD Version fehlerhaft", "0" },
{ "0x1A040A", "Interner Fehler, Messwerterfassung, Sensor: Zweiganggetriebe Feedback H-Br<42>cke 1 fehlerhaft", "0" },
{ "0x1A0031", "Interner Fehler, Messwerterfassung, Sensor: Bremsunterdrucksensorsignal fehlerhaft", "0" },
{ "0x002004", "NVM_E_ERASE_FAILED", "0" },
{ "0x1A0040", "Interner Fehler, Messwerterfassung, Sensor: Temperatur SLE Board fehlerhaft", "0" },
{ "0x1A004C", "Interner Fehler, Messwerterfassung, Sensor: SLE Gatetreiber Spannung fehlerhaft", "0" },
{ "0x1A006B", "Ebene2 Fehler PS, Command-Auswertung E1/E2 unterschiedlich", "0" },
{ "0x1A0409", "Interner Fehler, Messwerterfassung, Sensor: Position Zweiganggetriebe fehlerhaft", "0" },
{ "0x1A0017", "Interner Fehler, Messwerterfassung, Sensor: Zwischenkreisspannung fehlerhaft", "0" },
{ "0x1A0057", "Zwischenkreisspannung, <20>berspannung <20>ber CPLD ermittelt", "0" },
{ "0x1A0406", "Interner Fehler, Messwerterfassung, Sensor: Messsignal Motortemperatur Stator fehlerhaft", "0" },
{ "0x1A040B", "Interner Fehler, Messwerterfassung, Sensor: Zweiganggetriebe Feedback H-Br<42>cke 2 fehlerhaft", "0" },
{ "0x1A003E", "Interner Fehler, Messwerterfassung, Sensor: Temperatur 2 ELUP Endstufe fehlerhaft", "0" },
{ "0x1A0002", "Interner Fehler, Messwerterfassung, Sensor: Messsignal Motortemperatur 2 fehlerhaft", "0" },
{ "0x1A0070", "Ebene2 Fehler PS, Timeout Positionsverstellung", "0" },
{ "0x1A0038", "Interner Fehler, Messwerterfassung, Sensor: R<>ckmessung interne 32V fehlerhaft", "0" },
{ "0x1A0077", "Ebene2 Fehler PS, PS-Positions<6E>nderung ohne g<>ltiges PS-Kommando", "0" },
{ "0x1A0422", "Interner Fehler, Messwerterfassung, Sensor: Spannungswert SLE Board Revision fehlerhaft", "0" },
{ "0x1A0408", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Phasenstromsensoren fehlerhaft", "0" },
{ "0x1A0052", "Interner Fehler, Messwerterfassung, Sensor: DC/DC Zwischenkreisspannung fehlerhaft", "0" },
{ "0x1A0071", "Ebene2 Fehler PS, Timeout Init 10ms-Task E1", "0" },
{ "0x1A0059", "CPLD AKS Anforderung mit Signal /I_S_RST5_Cy0", "0" },
{ "0x1A0019", "Interner Fehler, Messwerterfassung, Sensor: Phasenstrom Inverter Phase V (redundant) fehlerhaft", "0" },
{ "0x002002", "NVM_E_READ_FAILED", "0" },
{ "0x1A005A", "CPLD AKS Anforderung mit Signal /I_S_RST5_Cy2", "0" },
{ "0x1A001A", "Interner Fehler, Messwerterfassung, Sensor: Phasenstrom Inverter Phase W (redundant) fehlerhaft", "0" },
{ "0x1A041B", "Interner Fehler, Messwerterfassung, Sensor: gefilterte SLE PFC Board Temperatur 1 fehlerhaft", "0" },
{ "0x1A0072", "Ebene2 Fehler PS, Drehrichtung PS schliessen falsch", "0" },
{ "0xC90401", "Puffer f<>r ausgehende Fehlermeldungen ist voll", "1" },
{ "0x002003", "NVM_E_CONTROL_FAILED", "0" },
{ "0x1A0008", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Inverter Gatedriver Phase W fehlerhaft", "0" },
{ "0x1A0027", "Interner Fehler, Messwerterfassung, Sensor: DC/DC Gatetreiber Spannung fehlerhaft", "0" },
{ "0x1A0006", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Inverter Gatedriver Phase U fehlerhaft", "0" },
{ "0x002006", "NVM_E_WRITE_ALL_FAILED", "0" },
{ "0x1A0403", "HV-Batterie: Ausfall Batteriek<65>hlung", "1" },
{ "0x1A0007", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Inverter Gatedriver Phase V fehlerhaft", "0" },
{ "0x1A0028", "Interner Fehler, Messwerterfassung, Sensor: analoger Messeingang SIN-Resolversignal fehlerhaft", "0" },
{ "0x1A0401", "HV-Powermanagement: eKMV degradiert bei Fahrbereitschaft", "1" },
{ "0x1A0005", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Inverter Phase W fehlerhaft", "0" },
{ "0x1A0035", "Interner Fehler, Messwerterfassung, Sensor: Analogsignal Spannungs<67>berwachung interne 5V CY320_MC2 fehlerhaft", "0" },
{ "0x1A0055", "Interner Fehler, Messwerterfassung, Sensor: DC/DC-Spannung2 Niedervoltseite fehlerhaft", "0" },
{ "0x1A0074", "Ebene2 Fehler PS, Drehrichtung PS oeffnen falsch", "0" },
{ "0x1A0402", "HV-Powermanagement: Verhindern Standfunktionen aufgrund niedrigem Ladezustand HV-Batterie", "1" },
{ "0x1A0066", "Qualifierueberwachung, CAN von eDME, Signalausfall 4", "0" },
{ "0x1A0400", "F_M_BMW_SIG_HVPM_FAULTTYPE -> Signalausfall : HV Powermanagement", "1" },
{ "0x1A0056", "Interner Fehler, Messwerterfassung, Sensor: DC/DC-Strom2 auf der Niedervoltseite fehlerhaft", "0" },
{ "0x1A0036", "Interner Fehler, Messwerterfassung, Sensor: Analogsignal Spannungs<67>berwachung interne 3.3V CY320_MC2 fehlerhaft", "0" },
{ "0x1A0003", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Inverter Phase U fehlerhaft", "0" },
{ "0x1A006C", "Ebene2 Fehler PS, EWS-Auswertung E1/E2 unterschiedlich", "0" },
{ "0x1A004D", "Interner Fehler, Messwerterfassung, Sensor: Steuer-/Ladeelektronik Pic nicht verbunden", "0" },
{ "0x002007", "NVM_E_READ_ALL_FAILED", "0" },
{ "0x1A004E", "Interner Fehler, Messwerterfassung, Sensor: DC/DC Pic nicht verbunden", "0" },
{ "0x1A006D", "Ebene2 Fehler PS, Sensor-Auswertung E1/E2 unterschiedlich", "0" },
{ "0x1A0411", "Interner Fehler, Messwerterfassung, Sensor: CY320 MC0 Versorgungsspannung 2 fehlerhaft", "0" },
{ "0x1A0079", "Checkcontrol 175: Getriebe-Position P gest<73>rt!", "0" },
{ "0x1A0078", "Checkcontrol 174: Getriebe-Position P nur im Stillstand!", "0" },
{ "0x1A0413", "Interner Fehler, Messwerterfassung, Sensor: Feedback Signal f<>r Parksperrenaktuator Notfallentriegelung fehlerhaft", "0" },
{ "0x1A000C", "Interner Fehler, Messwerterfassung, Sensor: Phasenstrom Inverter Phase V fehlerhaft", "0" },
{ "0x1A0410", "Interner Fehler, Messwerterfassung, Sensor: CY320 MC0 Versorgungsspannung 1 fehlerhaft", "0" },
{ "0x1A0416", "Interner Fehler, Messwerterfassung, Sensor: 3.3V Spannungseingang Dcdc Board fehlerhaft", "0" },
{ "0x1A0407", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Inverter Gatedriver fehlerhaft", "0" },
{ "0x1A0033", "Interner Fehler, Messwerterfassung, Sensor: analoges Messsignal <20>berwachung ELUP-Spannung fehlerhaft", "0" },
{ "0x1A007A", "Checkcontrol 203: Getriebe in Position N!", "0" },
{ "0x1A040E", "Interner Fehler, Messwerterfassung, Sensor: CY320 MC2 Versorgungsspannung 2 fehlerhaft", "0" },
{ "0x1A041A", "Interner Fehler, Messwerterfassung, Sensor: gefilterter Effektivwert von SLE PFC Strom fehlerhaft", "0" },
{ "0x1A0421", "Interner Fehler, Messwerterfassung, Sensor: gefilterte SLE PFC Board Temperatur 3 fehlerhaft", "0" },
{ "0x1A0049", "Interner Fehler, Messwerterfassung, Sensor: SLE Eingangsspannung fehlerhaft", "0" },
{ "0x1A0068", "Qualifierueberwachung, CAN von SME, Signalausfall 2", "0" },
{ "0x1A041E", "Interner Fehler, Messwerterfassung, Sensor: gefilterte SLE PFC Zwischenkreis Temperatur fehlerhaft", "0" },
{ "0x1A0420", "Interner Fehler, Messwerterfassung, Sensor: gefilterte SLE PFC Board Temperatur 2 fehlerhaft", "0" },
{ "0x1A0024", "Interner Fehler, Messwerterfassung, Sensor: DC/DC-Spannung Niedervoltseite fehlerhaft", "0" },
{ "0x1A006A", "Qualifierueberwachung, CAN von SME, Signalausfall 4", "0" },
{ "0x1A004B", "Interner Fehler, Messwerterfassung, Sensor: Spannung Ausgang PFC Stufe fehlerhaft", "0" },
{ "0x1A0021", "Interner Fehler, Messwerterfassung, Sensor: Temperatur DC/DC Tiefsetzsteller fehlerhaft", "0" },
{ "0x1A0061", "CPLD AKS Anforderung mit Signal /I_S_PHASE_OC_CPLD", "0" },
{ "0x1A0419", "Interner Fehler, Messwerterfassung, Sensor: gefilterter SLE LLC Strom fehlerhaft", "0" },
{ "0x1A0046", "Interner Fehler, Messwerterfassung, Sensor: SLE PFC-Summenstrom fehlerhaft", "0" },
{ "0x1A0000", "EME, interner Fehler, Momentenpfad: Abweichung Sollmoment Warnung", "0" },
{ "0x1A005F", "CPLD AKS Anforderung mit Signal I_S_INV_TEMP_CMP", "0" },
{ "0x1A001F", "Interner Fehler, Messwerterfassung, Sensor: Variantenerkennung DC/DC fehlerhaft", "0" },
{ "0x1A0076", "Ebene2 Fehler PS, PWM im Ruhezustand > 0", "0" },
{ "0x1A0418", "Interner Fehler, Messwerterfassung, Sensor: gefilterter Dcdc Trafostrom fehlerhaft", "0" },
{ "0x1A0417", "Interner Fehler, Messwerterfassung, Sensor: 5V Spannungseingang Dcdc Board fehlerhaft", "0" },
{ "0x001001", "Signal (Zeit_Sekunde_Zaehler_Relativ, 0x328): ung<6E>ltig", "1" },
{ "0x1A004A", "Interner Fehler, Messwerterfassung, Sensor: SLE Zwischenkreisspannung fehlerhaft", "0" },
{ "0x1A0069", "Qualifierueberwachung, CAN von SME, Signalausfall 3", "0" },
{ "0x1A0032", "Interner Fehler, Messwerterfassung, Sensor: Stromsignal der elektrischen Unterdruckpumpe fehlerhaft", "0" },
{ "0x1A0025", "Interner Fehler, Messwerterfassung, Sensor: DC/DC-Strom auf der Niedervoltseite fehlerhaft", "0" },
{ "0x1A0009", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Inverter Mux_Adc fehlerhaft", "0" },
{ "0x1A0051", "Interner Fehler, Messwerterfassung, Sensor: Ausgangsspannung DC/DC Tiefsetzsteller fehlerhaft", "0" },
{ "0x1A0048", "Interner Fehler, Messwerterfassung, Sensor: SLE Summenstrom Trafo fehlerhaft", "0" },
{ "0x1A0067", "Qualifierueberwachung, CAN von SME, Signalausfall 1", "0" },
{ "0x1A007F", "Checkcontrol 557: Fahrzeug gegen Wegrollen sichern!", "0" },
{ "0x1A0414", "Interner Fehler, Messwerterfassung, Sensor: Diagnoseeingang f<>r Massefehler fehlerhaft", "0" },
{ "0x1A003A", "Interner Fehler, Messwerterfassung, Sensor: Temperatur Phasenstromsensoren Temperaturkompensation des gemessenen Stroms MC0 fehlerhaft", "0" },
{ "0x1A007B", "Checkcontrol 244: Zum Gang einlegen Bremse treten!", "0" },
{ "0x1A007D", "Checkcontrol 252: Gong", "0" },
{ "0x1A0075", "Ebene2 Fehler PS, Unbekannter Zustand Regler beim PS oeffnen", "0" },
{ "0x1A0011", "Interner Fehler, Messwerterfassung, Sensor: Analogsignal Spannungs<67>berwachung interne 12V Klemme 30B fehlerhaft", "0" },
{ "0x1A041F", "Interner Fehler, Messwerterfassung, Sensor: SLE 3V A/D Konverter Referenzspannung fehlerhaft", "0" },
{ "0x1A0065", "Qualifierueberwachung, CAN von eDME, Signalausfall 3", "0" },
{ "0x1A0050", "Interner Fehler, Messwerterfassung, Sensor: DC/DC-Strom 2 Trafo fehlerhaft", "0" },
{ "0x1A006F", "Ebene2 Fehler PS, 10ms-Task E1 nicht aktiv", "0" },
{ "0x1A041C", "Interner Fehler, Messwerterfassung, Sensor: gefilterte SLE Hochvolttemperatur fehlerhaft", "0" },
{ "0x1A007C", "Checkcontrol 250: Gang ohne Bremse einlegbar!", "0" },
{ "0x1A0012", "Interner Fehler, Messwerterfassung, Sensor: Analogsignal Spannungs<67>berwachung interne 5V CY320_MC0 fehlerhaft", "0" },
{ "0x1A0022", "Interner Fehler, Messwerterfassung, Sensor: Temperatur DC/DC Gleichrichter fehlerhaft", "0" },
{ "0x1A0062", "CPLD AKS Anforderung mit Signal I_S_CPLD_SPARE_1", "0" },
{ "0x1A0073", "Ebene2 Fehler PS, Unbekannter Zustand Regler beim PS schliessen", "0" },
{ "0x1A0034", "Interner Fehler, Messwerterfassung, Sensor: Temperatur ELUP Endstufe fehlerhaft", "0" },
{ "0x1A0037", "Interner Fehler, Messwerterfassung, Sensor: Analogsignal Spannungs<67>berwachung interne 1.5V CY320_MC2 fehlerhaft", "0" },
{ "0x1A0404", "F_M_BMW_HVBATT_ISOERRDBL_FAULTTYPE -> HV Batterie : Isoaltionsfehler", "1" },
{ "0x1A005D", "CPLD AKS Anforderung mit Signal I_S_KL30C, Eingangssignal vom Einganspin der AE", "0" },
{ "0x1A001D", "Interner Fehler, Messwerterfassung, Sensor: DC/DC Tiefsetzsteller-Strom 1 fehlerhaft", "0" },
{ "0x1A0080", "Checkcontrol 565: Getriebe-Position P nur im Stillstand!", "0" },
{ "0x1A001E", "Interner Fehler, Messwerterfassung, Sensor: DC/DC Tiefsetzsteller-Strom 2 fehlerhaft", "0" },
{ "0x1A005E", "CPLD AKS Anforderung mit Signal /I_S_AKS_REQ_MC2", "0" },
{ "0x1A0405", "Interner Fehler, Messwerterfassung, Sensor: Messsignal Motortemperatur Drahtspuelenende fehlerhaft", "0" },
{ "0xFFFFFF", "unbekannter Fehlerort", "0" }
};
// Bitte Flags ausw<73>hlen!
table IDetailStruktur[2][]={
{ "NAME", "TYP" },
{ "F_UWB_ERW", "nein" },
{ "SAE_CODE", "nein" },
{ "F_HLZ", "nein" },
{ "F_SEVERITY", "nein" }
};
// Tabelle nur f<>r SGBDen der ISO 14229! Weitere Informationen finden Sie im Dokument: Anleitung_STATUS_STEUERN_UDS.pdf
table SG_Funktionen[16][]={
{ "ARG", "ID", "RESULTNAME", "INFO", "EINHEIT", "LABEL", "L/H", "DATENTYP", "NAME", "MUL", "DIV", "ADD", "SG_ADR", "SERVICE", "ARG_TABELLE", "RES_TABELLE" },
{ "STEUERN_START_LADEN", "0xADC0", "-", "Ladestart anfordern", "-", "B_remote_ladestart", "-", "-", "-", "-", "-", "-", "-", "31", "ARG_0xADC0", "-" },
{ "STEUERN_STOP_LADEN", "0xADC1", "-", "Ladestop anfordern", "-", "B_remote_ladestop", "-", "-", "-", "-", "-", "-", "-", "31", "ARG_0xADC1", "-" },
{ "REX_ON_OFF", "0xADC4", "-", "Ein-/Ausschalten des Range Extender Verbrennungsmotor", "-", "Pe_rex_soll_diag", "-", "-", "-", "-", "-", "-", "-", "31", "ARG_0xADC4", "-" },
{ "AE_EWP", "0xADC9", "-", "Ansteuern und Auslesen der elektrischen Wasserpumpe (Ansteuerung nur m<>glich bei AE Temperatur unter Schwelle, house keeping nicht aktiv, EWP nicht abgeschaltet und manuelle Drehzahl deaktivert)", "-", "V_e_EWP_ctl_status_test_job", "-", "-", "-", "-", "-", "-", "-", "31", "ARG_0xADC9", "RES_0xADC9" },
{ "EME_DCDC_WANDLER", "0xADF1", "-", "Steuern oder Auslesen des Status vom DC/DC-Wandler", "-", "-", "-", "-", "-", "-", "-", "-", "-", "31", "ARG_0xADF1", "RES_0xADF1" },
{ "EME_AKS_EMK", "0xADF4", "-", "E-Maschine in den AKS kommandieren: 0 - Kontrolle an EME-SW; 1 - AKS E-Maschine angefordert", "-", "V_e_DcmAksReq", "-", "-", "-", "-", "-", "-", "-", "31", "ARG_0xADF4", "RES_0xADF4" },
{ "AE_ROTORLAGESENSOR_ANLERNEN", "0xADF6", "-", "Anlernen Rotorlagesensor (TA-EOL STEUERN)", "-", "V_e_Rls_stdiag", "-", "-", "-", "-", "-", "-", "-", "31", "ARG_0xADF6", "RES_0xADF6" },
{ "AE_KLASSIERUNG", "0xADF8", "-", "Auslesen der Drehzahl/Drehmoment-Klassierungsdaten", "-", "-", "-", "-", "-", "-", "-", "-", "-", "31", "ARG_0xADF8", "RES_0xADF8" },
{ "AE_DCDC_HISTOGRAMM", "0xADF9", "-", "Lesen des angeforderten Histogramm des DCDC-Wandlers", "-", "-", "-", "-", "-", "-", "-", "-", "-", "31", "ARG_0xADF9", "RES_0xADF9" },
{ "EME_DCDC_LV", "0xDDF6", "-", "Spannung / Strom DCDC (12V Bordnetz) am B+ Bolzen", "-", "AVL_U_LV_DCDC_CNV", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDDF6" },
{ "EME_HVPM_DCDC_ANSTEUERUNG", "0xDE00", "-", "R<>ckgabewerte vom HVPM f<>r DCDC Ansteuerung", "-", "CHGCOND_HVSTO", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE00" },
{ "EME_HVPM_HV_SYSTEM_ON_OFF", "0xDE02", "-", "Hochvoltsystem An / Aus", "-", "AVL_U_HV_LINK_MOT_TRCT", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE02" },
{ "EME_HVPM_ENERGIEBORDNETZ", "0xDE03", "-", "R<>ckgabewerte des HVPM <20>ber HV-Energie und Zellspannungen", "-", "-", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE03" },
{ "EME_HVPM_ENERGIEBORDNETZ_2", "0xDE04", "-", "Anzahl der Herstellung von Fahrbereitschaft im SOC Bereich", "-", "-", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE04" },
{ "EME_HVPM_PKOR", "0xDE06", "-", "HVPM Leistungskoordinator", "-", "-", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE06" },
{ "EME_HVPM_INFOSPEICHER_PKOR_LOESCHEN", "0xDE08", "-", "Alle Infospeicher des Diagnosejobs STATUS_HVPM_EKMV werden auf Null gesetzt.", "-", "-", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0xDE08", "-" },
{ "EME_HVPM_INFOSPEICHER_STRZLR_LOESCHEN", "0xDE09", "-", "L<>schen des Infospeicher HSPM (STRZL)", "-", "-", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0xDE09", "-" },
{ "EME_HVPM_INFOSPEICHER_SPMON_LOESCHEN", "0xDE0A", "-", "L<>schen des Infospeichers HVPMP (SPMON)", "-", "-", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0xDE0A", "-" },
{ "EME_HVIL_GESAMT", "0xDE0C", "STAT_HVIL_GESAMT_NR", "Auslesen des HVIL-Zustandes in der EME; falls HVIL unterbrochen, dann n.i.O.", "0-n", "V_e_HvilError", "high", "unsigned char", "TAB_STAT_HVIL_GESAMT_NR", "1.0", "1.0", "0.0", "-", "22", "-", "-" },
{ "EME_HVPM_SPANNUNGSFREIHEIT", "0xDE18", "-", "Infospeicher zur Spannungsfreiheit des Hochvoltsystems (durch HVPM <20>berwacht)", "-", "NV_ZEIT_START_CCM_636[0]", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE18" },
{ "EME_ELUP", "0xDE19", "-", "Anzahl der Bremsbet<65>tigungen, Laufzeit und Anl<6E>ufe der ELUP", "-", "Anzahl_brems_bttg", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE19" },
{ "EME_HVPM_DCDC_ALS", "0xDE1C", "-", "HVPM DCDC ALS", "-", "-", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE1C" },
{ "AE_CPLD_VERSION", "0xDE2D", "STAT_CPLD_VERSION_WERT", "CPLD-Version", "-", "V_e_CpldVersion", "high", "unsigned char", "-", "1.0", "1.0", "0.0", "-", "22", "-", "-" },
{ "AE_CHARGE_ENABLE", "0xDE71", "STAT_CHARGE_ENABLE_NR", "Aussage <20>ber die Erteilung der Ladefreigabe", "0-n", "ST_CHGNG_ENB", "high", "unsigned char", "TAB_AE_CHARGE_ENABLE", "-", "-", "-", "-", "22", "-", "-" },
{ "AE_PARKSPERRE_SENSOREN", "0xDE74", "-", "Status Sensoren der Parksperre", "-", "VaPS_StaSen1_CanTx", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE74" },
{ "AE_HV_SPANNUNG_LESEN", "0xDE75", "-", "Werte aller Zwischenkreisspannungen", "-", "V_U_SleZk", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE75" },
{ "AE_PARKSPERRE_SW", "0xDE76", "STAT_PS_SW_NR", "Status Parksperren Software", "0-n", "VaPS_Quallifier_CanTx", "high", "unsigned char", "TAB_AE_PARKSPERREN_SW", "-", "-", "-", "-", "22", "-", "-" },
{ "AE_PARKSPERRE", "0xDE77", "-", "Zustand Parksperre / Einlegen Parksperre", "-", "-", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0xDE77", "-" },
{ "AE_PARKSPERRE_EINLERNEN", "0xDE78", "-", "Parksperre / Einlernen Parksperre", "-", "removeJob2", "-", "-", "-", "-", "-", "-", "-", "22;2E", "ARG_0xDE78", "RES_0xDE78" },
{ "AE_PARKSPERRE_POSITION", "0xDE79", "STAT_POSITION_PARKSPERRE_NR", "Aktuelle Position der Parksperre", "0-n", "removeJob3", "high", "unsigned int", "TAB_AE_PARKSPERRE_POSTION", "-", "-", "-", "-", "22", "-", "-" },
{ "AE_PARKSPERRE_POSITIONEN", "0xDE7A", "-", "R<>ckgabe angelernte Parksperrenpositionen", "-", "VaPS_PosGeschlossen", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE7A" },
{ "AE_PARKSPERRE_STROM", "0xDE7B", "STAT_STROM_PARKSPERRE_WERT", "Aktueller Strom Parksperrenaktuator", "A", "V_I_Psa", "high", "unsigned int", "-", "1.0", "1.0", "0.0", "-", "22", "-", "-" },
{ "AE_PARKSPERRE_SPANNUNGEN", "0xDE7C", "-", "Spannungen der Parksperre", "-", "VaPS_HB_Voltage", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE7C" },
{ "AE_ROHSIG_AUSGANG", "0xDE7D", "-", "Rohsignale Ausgangspins", "-", "V_DC_pbwHBModGrad_UE2", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE7D" },
{ "AE_ROHSIG_EINGANG_SENS_ELUP_BUDS", "0xDE7E", "-", "Rohsignale Ausgangspins Sensoren ELUP, BUDS", "-", "V_T_ElupLe_cal", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE7E" },
{ "AE_ROHSIG_EINGANG_SENS_EM_INV", "0xDE7F", "-", "Rohsignale Sensoren/Eing<6E>nge f<>r E-Maschine/Umrichter", "-", "V_T_Motor1_cal", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE7F" },
{ "AE_ROHSIG_EINGANG_SENS_PARKSPERRE", "0xDE80", "-", "Rohsignale Sensoren/Eing<6E>nge Parksperre", "-", "-", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE80" },
{ "AE_ROHSIG_EINGANG_SENS_SG", "0xDE81", "-", "Rohsignale Sensoren/Eing<6E>nge Steuerger<65>t", "-", "V_U_Int12V_cal", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE81" },
{ "AE_ROHSIG_EINGANG_SENS_SLE", "0xDE82", "-", "Rohsignale Sensoren/Eing<6E>nge SLE", "-", "-", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE82" },
{ "AE_ROHSIG_EINGANG_SENS_DCDC", "0xDE83", "-", "Rohsignale Sensoren/Eing<6E>nge DC/DC Wandler", "-", "V_U_DcdcLv_cal", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE83" },
{ "AE_BETRIEBSZUSTAND_SLE", "0xDE84", "-", "Betriebsarten SLE", "-", "V_F_SleAc", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE84" },
{ "AE_SLE_LEISTUNG", "0xDE85", "-", "Leistungswerte Zwischenkreis der SLE", "-", "V_P_XleIntLe_hv_ist", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE85" },
{ "AE_SLE_SPANNUNG", "0xDE86", "-", "AC und DC Spannungen SLE", "-", "V_U_SleAc", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE86" },
{ "AE_SLE_STROM", "0xDE87", "-", "AC und DC Str<74>me SLE", "-", "V_I_SlePfc", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE87" },
{ "AE_SPANNUNG_KLEMME30B", "0xDE88", "STAT_SPANNUNG_KL30B_WERT", "aktuelle Spannung an KL30B", "V", "V_U_Int12V", "high", "unsigned int", "-", "0.01", "1.0", "0.0", "-", "22", "-", "-" },
{ "AE_STROM_DCDC", "0xDE89", "-", "Str<74>me DC/DC Wandler", "-", "AVL_I_HV_DCDC", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE89" },
{ "AE_STROM_MAX", "0xDE8B", "-", "maximal gemessene Str<74>me seit letztem R<>cksetzen oder R<>cksetzen der Werte", "-", "V_I_DcdcHlDiag_Hv_mx_out", "-", "-", "-", "-", "-", "-", "-", "22;2E", "ARG_0xDE8B", "RES_0xDE8B" },
{ "AE_TEMP_LE", "0xDE8C", "-", "Temperaturen Steuerger<65>t Antriebselektronik", "-", "V_T_InvU", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE8C" },
{ "AE_ZUSTAND_1_DCDC", "0xDE92", "-", "Status DC/DC-Wandler", "-", "AVL_OPMO_DCDC_CNV", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE92" },
{ "AE_ELUP", "0xDE93", "-", "aktueller Zustand ELUP bzw. aktivieren/deaktivieren ELUP", "-", "V_e_DcmCtrlJobAct[ST_ELUP]", "-", "-", "-", "-", "-", "-", "-", "2E;22", "ARG_0xDE93", "RES_0xDE93" },
{ "AE_PARKSPERRE_MAGNET", "0xDE94", "-", "Einschalten Magnet Parksperre", "-", "-", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0xDE94", "-" },
{ "AE_PARKSPERRE_NVRAM_LOESCHEN", "0xDE95", "-", "L<>scht NV-RAM Daten der Parksperre", "-", "-", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0xDE95", "-" },
{ "AE_ZUSTAND_DCDC_FEHLERBILD", "0xDE96", "-", "R<>ckgabe aktiver/inaktiver Fehler DC/DC-Wandler", "bit", "V_e_DcdcHl_ErSt_out", "-", "BITFIELD", "RES_0xDE96", "-", "-", "-", "-", "22", "-", "-" },
{ "STATUS_CONNECTED_DRIVE", "0xDE9E", "-", "Informationen <20>ber Connected Drive", "-", "Hym_Ts_status_laden", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDE9E" },
{ "STATUS_TSR_LADEN", "0xDEA0", "-", "Alle R<>ckgabewert bez<65>glich TSR Laden", "-", "NV_anzahl_ladevorgaenge_gesamt", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDEA0" },
{ "AE_BUDS", "0xDEA5", "STAT_BUDS_WERT", "Sensorwert des Bremsunterdrucks", "hPa", "AVL_LOWP_BRKFA", "high", "unsigned char", "-", "4.0", "1.0", "-1000.0", "-", "22", "-", "-" },
{ "AE_TEMP_EMASCHINE", "0xDEA6", "-", "Wert der aktuellen Temperaturen der E-Maschine in Grad Celsius", "-", "V_T_Motor1", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDEA6" },
{ "AE_ELEKTRISCHE_MASCHINE", "0xDEA7", "-", "Auslesen von Drehzahl, Drehmoment und Betriebsart der E-Maschine", "-", "AVL_RPM_MOT_TRCT", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDEA7" },
{ "AE_ZUSTAND_2_DCDC", "0xDEA9", "-", "R<>ckgabe verschiederer Status vom DCDC-Wandler", "bit", "V_e_DcdcHl_St_out", "-", "BITFIELD", "RES_0xDEA9", "-", "-", "-", "-", "22", "-", "-" },
{ "AE_PARKSPERRE_VERSION", "0xDEB0", "-", "R<>ckgabe der aktuellen Version der Parksperren-SW", "-", "-", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDEB0" },
{ "AE_ROTORLAGESENSOR_SCHREIBEN", "0xDEB1", "-", "Direktes Schreiben des Resolveroffset Winkels", "-", "V_phi_DcmDiagRlsoffsetMan_def", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0xDEB1", "-" },
{ "AE_DCDC_TEMPHISTOGRAMM_LESEN", "0xDEB2", "-", "Auslesen Temperatur-Histogramme DCDC / R<>cksetzen Temperatur-Histogramme (0 = kein Reset; 1 = Reset)", "-", "V_e_DcmDcdcDiag_Histo_T_rst", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0xDEB2", "-" },
{ "AE_DCDC_LEISTUNGSHISTOGRAMM", "0xDEB3", "-", "Auslesen Leistungs-Histogramme DCDC-Wandler / Zur<75>cksetzen Leistungs-Histogramme (0 = kein Reset; 1 = Reset)", "-", "V_e_DcdcDiag_Histo_P_rst", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0xDEB3", "-" },
{ "AE_RESET_TEMP_MIN_MAX", "0xDEB4", "-", "R<>cksetzen der minimalen und maximalen Temperatur des DC/DC Wandlers (0 = kein Reset; 1 = Reset)", "-", "V_e_DcdcDiag_T_rst", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0xDEB4", "-" },
{ "AE_PIC_SW_VERSION", "0xDEB5", "-", "Gibt aktuellen Versionen der PIC-SW zur<75>ck", "-", "V_s_DcdcSwVersion", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDEB5" },
{ "AE_ROTORLAGESENSOR_RESET", "0xDEB6", "-", "Zur<75>cksetzen des Resolveroffsetwinkels", "-", "V_e_DcmDiagRlsoffsetReset", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0xDEB6", "-" },
{ "AE_KLASSIERUNG_LOESCHEN", "0xDEB7", "-", "Loeschen der gesamten Klassierungsdaten", "-", "-", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0xDEB7", "-" },
{ "AE_CTRL_VERSION", "0xDEBC", "STAT_CTRL_VERSION_WERT", "Controllerbord-Version", "-", "V_e_CtrlVarIn", "high", "unsigned char", "-", "1.0", "1.0", "0.0", "-", "22", "-", "-" },
{ "AE_SPANNUNG_DCDC", "0xDEBD", "-", "Spannungen DCDC Wandler", "-", "V_U_DcdcGtMc6", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDEBD" },
{ "AE_SPANNUNG_LE", "0xDEBE", "-", "Interne Spannungen der Leistungselektronik", "-", "V_U_Int5VMc0", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDEBE" },
{ "AE_SYSSTATE", "0xDEBF", "-", "Interne Statuszust<73>nde des Steuerger<65>t", "-", "V_e_VsmDprActive", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDEBF" },
{ "AE_FAHRSTUFE", "0xDEDD", "STAT_POS_PRND_NR", "aktuelle Ist-Position des Antriebsstrangs (PRND)", "0-n", "Hym_Vetrgr_e_achvdtrnspos", "high", "unsigned char", "TAB_AE_FAHRSTUFE", "-", "-", "-", "-", "22", "-", "-" },
{ "AE_LSC_LADEN", "0xDEDE", "-", "R<>ckmeldung zum Ladeverfahrens", "-", "Hym_St_ladeverfahren_diag", "-", "-", "-", "-", "-", "-", "-", "22", "-", "RES_0xDEDE" },
{ "AE_SN_SETZEN", "0x400C", "-", "Seriennummer", "-", "-", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0x400C", "-" },
{ "AE_HWCAL_SETZEN", "0x400D", "-", "Hardware Kalibrierungsdaten der AE setzen Es kann nicht die Seriennummer gesetz werden (eigener Job _steuern_sn_setzen)!!!", "-", "-", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0x400D", "-" },
{ "AE_HWCAL_FLASHEN", "0x400E", "-", "Schreibt die HWCALs eines bestimmten Blocks ins Flash", "-", "-", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0x400E", "-" },
{ "AE_HWCAL_MODE", "0x400F", "-", "SG in den HWCAL Flash-Mode bringen", "-", "-", "-", "-", "-", "-", "-", "-", "-", "2E", "ARG_0x400F", "-" },
{ "AE_HWCAL_LESEN", "0xF010", "-", "Auslesen der HWCALs anhand von Blocknummer und Prozessor", "-", "-", "-", "-", "-", "-", "-", "-", "-", "31", "ARG_0xF010", "RES_0xF010" },
{ "AE_RESETINFO_LESEN", "0xF011", "-", "Auslesen der Resetinfo aus dem Flash", "-", "-", "-", "-", "-", "-", "-", "-", "-", "31", "ARG_0xF011", "RES_0xF011" },
{ "AE_FREILAUF_MODUS", "0xF050", "-", "Freilauf Modus", "-", "-", "-", "-", "-", "-", "-", "-", "-", "31", "-", "RES_0xF050" }
};
table RES_0x1700[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_DID_1700_KILOMETER_WERT", "-", "-", "unsigned long", "-", "-", "-", "-", "-", "-" }
};
table ARG_0x1700[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "DIAG_DID_1700_KILOMETER", "-", "-", "unsigned long", "-", "-", "-", "-", "-", "-", "-", "-" }
};
// -
table TAB_STAT_ROTORLAGESENSOR_STATUS_MODE[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Die Routine Rotorlagesensor Anlernen ist nicht angefordert." },
{ "0x01", "Die Routine Rotorlagesensor Anlernen ist angefordert und aktiv, aber es findet gerade kein aktiver Abgleich statt." },
{ "0x02", "Die Routine Rotorlagesensor Anlernen ist angefordert und aktiv." },
{ "0x03", "Die Routine Rotorlagesensor Anlernen wurde fehlerhaft beendet." },
{ "0x04", "Die Routine Rotorlagesensor Anlernen wurde erfolgreich beendet." }
};
// WERTE
table TAB_AE_SYSSYSTATE_MCS[2][]={
{ "WERT", "TEXT" },
{ "0x00", "eINITIALIZATION" },
{ "0x01", "ePREDRIVE" },
{ "0x02", "eREADY" },
{ "0x03", "eWAITSLEEPACKNOWLEDGE" },
{ "0x04", "eFUNCTIONPOSTDRIVE" }
};
// BITFIELD
table BF_SYSSYSTATE_KLEMMEN[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_SYSSYSTATE_KL153_0", "0/1", "high", "unsigned char", "0x01", "-", "-", "-", "-", "Klemmenzustand (bitcodiert): Bit0 = Kl15_3" },
{ "STAT_SYSSYSTATE_KL15WUP_1", "0/1", "high", "unsigned char", "0x02", "-", "-", "-", "-", "Klemmenzustand (bitcodiert): Bit1 = Kl15WUP" },
{ "STAT_SYSSYSTATE_KL30B_2", "0/1", "high", "unsigned char", "0x04", "-", "-", "-", "-", "Klemmenzustand (bitcodiert): Bit2 = KL30B" },
{ "STAT_SYSSYSTATE_KL30C_3", "0/1", "high", "unsigned char", "0x08", "-", "-", "-", "-", "Klemmenzustand (bitcodiert): Bit3 = KL30C" }
};
// WERTE
table TAB_AE_RESET_CRASHZAEHLER[2][]={
{ "WERT", "TEXT" },
{ "0x00", "keine Aktion" },
{ "0x01", "r<>cksetzen 1.Crashz<68>hler" },
{ "0x02", "r<>cksetzen 2.Crashz<68>hler" },
{ "0x03", "r<>cksetzen 1.Crashz<68>hlers und 2.Crashz<68>hlers" },
{ "0xFE", "nicht definiert" },
{ "0xFF", "ung<6E>ltiger Wert" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xADC0[14][]={
{ "ARG", "STR", "STPR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "STAT_ANFORDERUNG_START_LADEN", "+", "-", "0/1", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "-", "-", "Ladestart anfordern = 1; keine Anforderung = 0" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xADC1[14][]={
{ "ARG", "STR", "STPR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "STAT_ANFORDERUNG_STOP_LADEN", "+", "-", "0/1", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "-", "-", "Ladestopp anfordern = 1; keine Anforderung = 0" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xADC4[14][]={
{ "ARG", "STR", "STPR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "REX_SOLL_LEISTUNG", "+", "-", "W", "high", "unsigned int", "-", "-", "1.0", "100.0", "0.0", "0.0", "28000.0", "Sollleistung, die der Motor liefern soll" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xADC9[14][]={
{ "ARG", "STR", "STPR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "STAT_EWP_ANST_WERT", "+", "-", "%", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "1.0", "100.0", "Ansteuerwert in % (0 - 100%)" },
{ "STAT_EWP_TO_ANST_WERT", "+", "-", "s", "high", "unsigned char", "-", "-", "0.5", "1.0", "0.0", "0.0", "510.0", "Timeout elektrische Wasserpumpe (0-510s)" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xADF1[14][]={
{ "ARG", "STR", "STPR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "ST_DIAG_DCDC_ANF", "+", "-", "0-n", "high", "unsigned char", "-", "TAB_ST_DIAG_DCDC_ANF", "1.0", "1.0", "0.0", "-", "-", "Anforderung Betriebsart DCDC" },
{ "ST_B_DIAG_DCDC", "+", "-", "0-n", "high", "unsigned char", "-", "TAB_ST_B_DIAG_DCDC", "-", "-", "-", "-", "-", "Auswahl der Systemgrenze" },
{ "I_DIAG_DCDC_LV_OUT", "+", "-", "A", "high", "int", "-", "-", "10.0", "1.0", "0.0", "-200.0", "200.0", "LV Strom Systemgrenze" },
{ "I_DIAG_DCDC_HV_OUT", "+", "-", "A", "high", "int", "-", "-", "10.0", "1.0", "0.0", "-25.0", "25.0", "HV Strom Systemgrenze" },
{ "U_DIAG_DCDC_LV_OUT", "+", "-", "V", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "0.0", "33.0", "LV Spannung Systemgrenze" },
{ "U_DIAG_DCDC_HV_OUT", "+", "-", "V", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "0.0", "300.0", "HV Spannung Systemgrenze" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xADF4[14][]={
{ "ARG", "STR", "STPR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKS_ANFORDERUNG", "+", "-", "0/1", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "-", "-", "0 - Kontrolle an EME-SW; 1 - AKS E-Maschine angefordert" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xADF6[14][]={
{ "ARG", "STR", "STPR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKTION", "+", "-", "0-n", "high", "unsigned char", "-", "TAB_AE_ROTORLAGESENSOR_ANLEREN_AKTION", "-", "-", "-", "-", "-", "0x00 = Auto RLS-Anlernen 0x01 = Hochdrehen/Freilauf" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xADF8[14][]={
{ "ARG", "STR", "STPR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "DREHZAHL_KLASSE", "+", "-", "0-n", "high", "unsigned char", "-", "TAB_AE_DREHZAHL_KLASSE", "-", "-", "-", "-", "-", "Drehzahl-Klasse: 0 = 0-2000 U/min 1 = 2000-4000 U/min 2 = 4000-6000 U/min 3 = 6000-8000 U/min 4 = 8000-10000 U/min 5 = 10000-12000 U/min 6 = 12000-14000 U/min" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xADF9[14][]={
{ "ARG", "STR", "STPR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "HISTOGRAMM_NR", "+", "-", "0-n", "high", "unsigned char", "-", "TAB_AE_DCDC_HISTOGRAMM", "-", "-", "-", "-", "-", "Histogramm das angefordert wird: 0 = PHistoF 1 = PHistoL 2 = T1HistoF 3 = T1HistoL 4 = T2HistoF 5 = T2HistoL 6 = T3HistoF 7 = T3HistoL 8 = T4HistoF 9 = T4HistoL 10 = rUtil 11 = rUtilF" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDE08[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "DUMMY", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "-", "-", "wegen Kompatibilit<69>t zu ToolSet32" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDE09[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "DUMMY", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "-", "-", "wegen Kompatibilit<69>t zu ToolSet32" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDE0A[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "DUMMY", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "-", "-", "wegen Kompatibilit<69>t zu ToolSet32" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDE77[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKTION", "0-n", "high", "unsigned char", "-", "TAB_AE_PARKSPERRE", "-", "-", "-", "-", "-", "<22>ndern des Zustandes der Parksperre ( 0 = kein Einlegen; 1 = Einlegen der Parksperre )" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDE78[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKTION", "0-n", "high", "unsigned char", "-", "TAB_AE_PARKSPERRE_EINLERNEN_STEUERN", "-", "-", "-", "-", "-", "Vorgabe Anlernen ( 0 = kein Anlernen; 1 = Anlernen der Parksperre)" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDE8B[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKTION", "0-n", "high", "unsigned char", "-", "TAB_AE_RESET_STROM_MAX", "-", "-", "-", "-", "-", "Anforderung der Str<74>me, die zur<75>ckgesetzt werden sollen" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDE93[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKTION", "0-n", "high", "unsigned char", "-", "TAB_AE_ELUP_STEUERN", "-", "-", "-", "-", "-", "Ansteuerung der ELUP f<>r 1 Sekunde (elektrische <20>berwachung bleibt aktiv!)" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDE94[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKTION", "0-n", "high", "unsigned char", "-", "TAB_AE_PARKSPERRE_MAGNET_STEUERN", "-", "-", "-", "-", "-", "M<>gliche Zust<73>nde des Parksperren-Magneten ( 0 = kein Einschalten; 1 = Einschalten )" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDE95[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKTION", "0-n", "high", "unsigned char", "-", "TAB_AE_PARKSPERRE_NVRAM_LOESCHEN", "-", "-", "-", "-", "-", "M<>gliche Ausf<73>hrung des L<>schens vom NV-RAM der Parksperre ( 0 = kein L<>schen; 1 = L<>schen )" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDEB1[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "OFFSET", "<22>", "high", "int", "-", "-", "1.0", "0.0055", "0.0", "-", "-", "Resolver Offset Winkel" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDEB2[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKTION", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "-", "-", "Aktion: 0 = kein Reset; 1 = Reset" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDEB3[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKTION", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "-", "-", "Aktion: 0 = kein Reset; 1 = Reset" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDEB4[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKTION", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "-", "-", "Aktion: 0 = kein Reset; 1 = Reset" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDEB6[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKTION", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "-", "-", "0 = nicht r<>cksetzen; 1 = r<>cksetzen" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xDEB7[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKTION", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "-", "-", "0 = nicht loeschen 1 = loeschen" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xADC9[13][]={
{ "RESULTNAME", "STR", "STPR", "RRR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_EWP_STATUS_NR", "-", "-", "+", "0-n", "high", "unsigned char", "-", "TAB_AE_EWP_STATUS", "-", "-", "-", "Status der Elektrischen Wasserpumpe" },
{ "STAT_EWP_ANST_WERT", "-", "-", "+", "%", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Drehzahl der Wasserpumpe in Prozent (0 - 100%)" },
{ "STAT_EWP_TESTER_DOND", "-", "-", "+", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "Bedingung f<>r Testerkontrolle: 0 = nicht erf<72>llt; 1 = erf<72>llt" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xADF1[13][]={
{ "RESULTNAME", "STR", "STPR", "RRR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ST_DIAG_DCDC_MODUS", "-", "-", "+", "0-n", "high", "unsigned char", "-", "TAB_STAT_ST_DIAG_DCDC_MODUS", "1.0", "1.0", "0.0", "R<>ckmeldung Betriebsart DCDC" },
{ "STAT_ST_DIAG_DCDC_GRENZEN", "-", "-", "+", "0-n", "high", "unsigned char", "-", "TAB_STAT_ST_DIAG_DCDC_GRENZEN", "1.0", "1.0", "0.0", "R<>ckmeldung Grenzen" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xADF4[13][]={
{ "RESULTNAME", "STR", "STPR", "RRR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_AKS_ANFORDERUNG", "-", "-", "+", "0-n", "high", "unsigned char", "-", "TAB_STAT_AKS_ANFORDERUNG", "-", "-", "-", "0 - kein AKS; 1 - AKS; 2 - Fehler" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xADF6[13][]={
{ "RESULTNAME", "STR", "STPR", "RRR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_BF_ROTORLAGESENSOR_STATUS_ERROR", "-", "-", "+", "Bit", "high", "bitfield", "-", "BF_AE_ROTORLAGESENSOR_ERROR", "-", "-", "-", "Infos zum Status des Rotorlagesensor Anlernens und zum Fehler" },
{ "STAT_ROTORLAGESENSOR_WERT", "-", "-", "+", "-", "high", "unsigned int", "-", "-", "0.0055", "1.0", "-180.22", "EPS Offset" },
{ "STAT_UDSPANNUNG_WERT", "-", "-", "+", "V", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "R<>cklesen der Ud Spannung" },
{ "STAT_UQSPANNUNG_WERT", "-", "-", "+", "V", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "R<>cklesen der Uq Spannung" },
{ "STAT_DREHZAHL_WERT", "-", "-", "+", "1/min", "high", "int", "-", "-", "1.0", "1.0", "0.0", "R<>cklesen der Drehzahl" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xADF8[13][]={
{ "RESULTNAME", "STR", "STPR", "RRR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_DREHZAHL_KLASSE", "+", "-", "-", "0-n", "high", "unsigned char", "-", "TAB_AE_DREHZAHL_KLASSE", "-", "-", "-", "Drehzahl-Klasse" },
{ "STAT_KMSTAND_START_WERT", "+", "-", "-", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Kilometerstand bei Start der Klassierung" },
{ "STAT_KMSTAND_AKTUELL_WERT", "+", "-", "-", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Kilometerstand der Klassierung (aktuell)" },
{ "STAT_DKVAL01_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 01" },
{ "STAT_DKVAL02_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 02" },
{ "STAT_DKVAL03_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 03" },
{ "STAT_DKVAL04_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 04" },
{ "STAT_DKVAL05_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 05" },
{ "STAT_DKVAL06_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 06" },
{ "STAT_DKVAL07_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 07" },
{ "STAT_DKVAL08_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 08" },
{ "STAT_DKVAL09_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 09" },
{ "STAT_DKVAL10_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 10" },
{ "STAT_DKVAL11_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 11" },
{ "STAT_DKVAL12_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 12" },
{ "STAT_DKVAL13_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 13" },
{ "STAT_DKVAL14_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 14" },
{ "STAT_DKVAL15_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 15" },
{ "STAT_DKVAL16_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 16" },
{ "STAT_DKVAL17_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 17" },
{ "STAT_DKVAL18_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 18" },
{ "STAT_DKVAL19_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 19" },
{ "STAT_DKVAL20_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 20" },
{ "STAT_DKVAL21_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 21" },
{ "STAT_DKVAL22_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 22" },
{ "STAT_DKVAL23_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 23" },
{ "STAT_DKVAL24_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 24" },
{ "STAT_DKVAL25_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 25" },
{ "STAT_DKVAL26_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 26" },
{ "STAT_DKVAL27_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 27" },
{ "STAT_DKVAL28_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 28" },
{ "STAT_DKVAL29_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 29" },
{ "STAT_DKVAL30_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 30" },
{ "STAT_DKVAL31_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 31" },
{ "STAT_DKVAL32_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 32" },
{ "STAT_DKVAL33_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 33" },
{ "STAT_DKVAL34_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 34" },
{ "STAT_DKVAL35_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 35" },
{ "STAT_DKVAL36_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 36" },
{ "STAT_DKVAL37_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 37" },
{ "STAT_DKVAL38_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 38" },
{ "STAT_DKVAL39_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 39" },
{ "STAT_DKVAL40_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Drehzahl-Klasse Wert 40" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xADF9[13][]={
{ "RESULTNAME", "STR", "STPR", "RRR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_HISTVAL_01_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "1. Wert des angeforderten Histogramm" },
{ "STAT_HISTVAL_02_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "2. Wert des angeforderten Histogramm" },
{ "STAT_HISTVAL_03_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "3. Wert des angeforderten Histogramm" },
{ "STAT_HISTVAL_04_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "4. Wert des angeforderten Histogramm" },
{ "STAT_HISTVAL_05_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "5. Wert des angeforderten Histogramm" },
{ "STAT_HISTVAL_06_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "6. Wert des angeforderten Histogramm" },
{ "STAT_HISTVAL_07_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "7. Wert des angeforderten Histogramm" },
{ "STAT_HISTVAL_08_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "8. Wert des angeforderten Histogramm" },
{ "STAT_HISTVAL_09_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "9. Wert des angeforderten Histogramm" },
{ "STAT_HISTVAL_10_WERT", "+", "-", "-", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "10. Wert des angeforderten Histogramm" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDDF6[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_SPANNUNG_DCDC_LV_WERT", "V", "high", "unsigned int", "-", "-", "0.01", "1.0", "0.0", "DCDC Wandler: IST-Spannung LV-Seite am B+ Bolzen" },
{ "STAT_STROM_DCDC_LV_WERT", "A", "high", "int", "-", "-", "0.1", "1.0", "0.0", "DCDC Wandler: IST-Strom LV-Seite am B+ Bolzen" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE00[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_SOC_HVB_WERT", "%", "high", "unsigned int", "-", "-", "0.1", "1.0", "0.0", "Ladezustand HV Batterie" },
{ "STAT_SOC_HVB_MIN_WERT", "%", "high", "unsigned char", "-", "-", "0.5", "1.0", "0.0", "Startf<74>higkeitsgrenze Ladezustand HV Batterie" },
{ "STAT_LADEGERAET", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "Ladeger<65>t erkannt (1 = erkannt / 0 = nicht erkannt)" },
{ "STAT_FREMDLADUNG", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "Fremdladung (1 = erkannt / 0 = nicht erkannt)" },
{ "STAT_FAHRB", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "Fahrbereitschaft (1 = aktiv / 0 = nicht aktiv)" },
{ "STAT_BA_DCDC_KOMM_NR", "0-n", "high", "unsigned char", "-", "TAB_EME_KOMM_BETRIEBSART_DCDC", "-", "-", "-", "Kommandierte Betriebsart DC/DC Wandler" },
{ "STAT_I_DCDC_HV_OUT_WERT", "A", "high", "int", "-", "-", "0.1", "1.0", "0.0", "Stromgrenze HV-Seite" },
{ "STAT_U_DCDC_HV_OUT_WERT", "V", "high", "unsigned int", "-", "-", "0.1", "1.0", "0.0", "Spannungsgrenze HV-Seite" },
{ "STAT_I_DCDC_LV_OUT_WERT", "A", "high", "int", "-", "-", "0.1", "1.0", "0.0", "Stromgrenze NV-Seite" },
{ "STAT_U_DCDC_LV_OUT_WERT", "V", "high", "unsigned int", "-", "-", "0.01", "1.0", "0.0", "Spannungsgrenze NV-Seite" },
{ "STAT_BA_DCDC_IST_NR", "0-n", "high", "unsigned char", "-", "TAB_EME_IST_BETRIEBSART_DCDC", "-", "-", "-", "IST-Betriebsart DCDC-Wandler" },
{ "STAT_ALS_DCDC_WERT", "%", "high", "unsigned char", "-", "-", "0.5", "1.0", "0.0", "Auslastung DC/DC-Wandler" },
{ "STAT_I_DCDC_HV_WERT", "A", "high", "int", "-", "-", "0.1", "1.0", "0.0", "Strom HV-Seite" },
{ "STAT_U_DCDC_HV_WERT", "V", "high", "unsigned int", "-", "-", "0.1", "1.0", "0.0", "Spannung HV-Seite" },
{ "STAT_I_DCDC_LV_WERT", "A", "high", "int", "-", "-", "0.1", "1.0", "0.0", "Strom NV-Seite" },
{ "STAT_U_DCDC_LV_WERT", "V", "high", "unsigned int", "-", "-", "0.01", "1.0", "0.0", "Spannung NV-Seite" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE02[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_U_DC_HV_LE_WERT", "V", "high", "int", "-", "-", "0.0313", "1.0", "0.0", "HV-Zwischenkreisspannung" },
{ "STAT_HV_READY", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "Freigabe HV" },
{ "STAT_HDCAC_EREQ", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "Anforderung Schlie<69>en Sch<63>tze HV-Batterie" },
{ "STAT_I0ANF_HVB", "0-n", "high", "unsigned char", "-", "TAB_EME_I0ANF_HVB", "-", "-", "-", "Status Nullstromanforderung" },
{ "STAT_ANF_ENTL_DCDC", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "Anforderung Entladung HV-Zwischenkreis durch DCDC-Wandler" },
{ "STAT_HVSTART_KOMM", "0-n", "high", "unsigned char", "-", "TAB_EME_HVSTART_KOMM", "-", "-", "-", "Ausgabe des Stateflow-Status des HVPM Startsystems" },
{ "STAT_ANF_ENTL_EME", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "Anforderung Notentladung ZK: 0 = nicht aktiv; 1 = aktiv" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE03[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_NV_MSA_DCDC_WERT", "Ah", "high", "unsigned int", "-", "-", "0.0010", "1.0", "0.0", "Z<>hler Ladungsmenge DC/DC MSA" },
{ "STAT_NV_MSA_EKK_WERT", "Ah", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Z<>hler Ladungsmenge EKK MSA" },
{ "STAT_NV_ENTL_EKK_STD_WERT", "Ah", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Z<>hler Ladungsmenge EKK Standk<64>hlung" },
{ "STAT_NV_ENTL_EKK15_WERT", "Ah", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Z<>hler Ladungsmenge EKK Kl15" },
{ "STAT_NV_ENTL_DCDC15_WERT", "Ah", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Z<>hler Ladungsmenge DC/DC Kl15" },
{ "STAT_NV_ENTL_EM1_WERT", "Ah", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Z<>hler Ladungsmenge EM1" },
{ "STAT_NV_ENTL_EKK_WERT", "Ah", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Z<>hler Ladungsmenge EKK" },
{ "STAT_NV_ENTL_DCDC_WERT", "Ah", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Z<>hler Ladungsmenge DC/DC" },
{ "STAT_NV_MSA_EM1_WERT", "Ah", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Z<>hler Ladungsmenge EM1 MSA" },
{ "STAT_NV_UHVB_SB_NULL_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB0" },
{ "STAT_NV_UHVB_SB_1_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB1" },
{ "STAT_NV_UHVB_SB_2_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB2" },
{ "STAT_NV_UHVB_SB_3_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB3" },
{ "STAT_NV_UHVB_SB_4_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB4" },
{ "STAT_NV_UHVB_SB_5_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB5" },
{ "STAT_NV_UHVB_SB_6_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB6" },
{ "STAT_NV_UHVB_SB_7_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB7" },
{ "STAT_NV_UHVB_SB_8_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB8" },
{ "STAT_NV_UHVB_SB_9_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB9" },
{ "STAT_NV_UHVB_SB_10_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB10" },
{ "STAT_NV_UHVB_SB_11_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB11" },
{ "STAT_NV_UHVB_SB_12_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB12" },
{ "STAT_NV_UHVB_SB_13_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB13" },
{ "STAT_NV_UHVB_SB_14_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB14" },
{ "STAT_NV_UHVB_SB_15_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB15" },
{ "STAT_NV_UHVB_SB_16_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB16" },
{ "STAT_NV_UHVB_SB_17_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB17" },
{ "STAT_NV_UHVB_SB_18_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB18" },
{ "STAT_NV_UHVB_SB_19_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB19" },
{ "STAT_NV_UHVB_SB_20_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB20" },
{ "STAT_NV_UHVB_SB_21_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB21" },
{ "STAT_NV_UHVB_SB_22_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB22" },
{ "STAT_NV_UHVB_SB_23_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB23" },
{ "STAT_NV_UHVB_SB_24_WERT", "s", "high", "long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittliche Zellenspannung in SB24" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE04[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_NV_HVB_SOC_FAHRB_0_20_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" },
{ "STAT_NV_HVB_SOC_FAHRB_20_25_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" },
{ "STAT_NV_HVB_SOC_FAHRB_25_30_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" },
{ "STAT_NV_HVB_SOC_FAHRB_30_33_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" },
{ "STAT_NV_HVB_SOC_FAHRB_33_36_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" },
{ "STAT_NV_HVB_SOC_FAHRB_36_39_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" },
{ "STAT_NV_HVB_SOC_FAHRB_39_42_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" },
{ "STAT_NV_HVB_SOC_FAHRB_42_45_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" },
{ "STAT_NV_HVB_SOC_FAHRB_45_48_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" },
{ "STAT_NV_HVB_SOC_FAHRB_48_51_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" },
{ "STAT_NV_HVB_SOC_FAHRB_51_56_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" },
{ "STAT_NV_HVB_SOC_FAHRB_56_65_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" },
{ "STAT_NV_HVB_SOC_FAHRB_65_80_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" },
{ "STAT_NV_HVB_SOC_FAHRB_80_100_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ladezustand HV-Batterie bei Herstellung Fahrbereitschaft" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE06[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_NV_KM_DEG_EKMV_VM_AN_A_WERT", "km", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "Kilometerstand bei Beginn der Reduzierung EKMV bei VM an. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_T_DEG_EKMV_VM_AN_A_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Gesamtdauer der Reduzierungen EKMV bei VM an. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_KM_DEG_BUCK_VM_AN_A_WERT", "km", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "Kilometerstand bei beginn der Reduzierung Buckmode bei VM an. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_T_DEG_BUCK_VM_AN_A_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Gesamtdauer der Reduzierungen Buckmode bei VM an. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_KM_DEG_EKMV_VM_AUS_A_WERT", "km", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "Kilometerstand bei beginn der Reduzierung EKMV bei VM aus. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_T_DEG_EKMV_VM_AUS_A_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Gesamtdauer der Reduzierungen EKMV bei VM aus. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_KM_DEG_BUCK_VM_AUS_A_WERT", "km", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "Kilometerstand bei beginn der Reduzierung Buckmode bei VM aus. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_T_DEG_BUCK_VM_AUS_A_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Gesamtdauer der Reduzierungen Buckmode bei VM aus. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_KM_DEG_EKMV_VM_AN_B_WERT", "km", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "Kilometerstand bei beginn der Reduzierung EKMV bei VM an. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_T_DEG_EKMV_VM_AN_B_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Gesamtdauer der Reduzierungen EKMV bei VM an. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_KM_DEG_BUCK_VM_AN_B_WERT", "km", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "Kilometerstand bei beginn der Reduzierung Buckmode bei VM an. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_T_DEG_BUCK_VM_AN_B_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Gesamtdauer der Reduzierungen Buckmode bei VM an. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_KM_DEG_EKMV_VM_AUS_B_WERT", "km", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "Kilometerstand bei Beginn der Reduzierung EKMV bei VM aus. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_T_DEG_EKMV_VM_AUS_B_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Gesamtdauer der Reduzierungen EKMV bei VM aus. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_KM_DEG_BUCK_VM_AUS_B_WERT", "km", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "Kilometerstand bei beginn der Reduzierung Buckmode bei VM aus. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_T_DEG_BUCK_VM_AUS_B_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Gesamtdauer der Reduzierungen Buckmode bei VM aus. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_KM_DEG_EM1_LL_A_WERT", "km", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "Kilometerstand bei beginn der Reduzierung EM im Leerlauf. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_T_DEG_EM1_LL_A_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Gesamtdauer der Reduzierungen EM im Leerlauf. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_KM_DEG_EM1_LL_B_WERT", "km", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "Kilometerstand bei beginn der Reduzierung EM im Leerlauf. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_T_DEG_EM1_LL_B_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Gesamtdauer der Reduzierungen EM nicht im Leerlauf. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_KM_DEG_EM1_NOTLL_A_WERT", "km", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "Kilometerstand bei beginn der Reduzierung EM nicht im Leerlauf. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_T_DEG_EM1_NOTLL_A_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Gesamtdauer der Reduzierungen EM nicht im Leerlauf. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_KM_DEG_EM1_NOTLL_B_WERT", "km", "high", "unsigned int", "-", "-", "10.0", "1.0", "0.0", "Kilometerstand bei beginn der Reduzierung EM nicht im Leerlauf. <20>nderung nur bei Reduzierungen > 1min." },
{ "STAT_NV_T_DEG_EM1_NOTLL_B_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Gesamtdauer der Reduzierungen EM nicht im Leerlauf. <20>nderung nur bei Reduzierungen > 1min." }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE18[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ZEIT_START_CCM_636_0_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Startzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang)" },
{ "STAT_ZEIT_STOP_CCM_636_0_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Stopzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang)" },
{ "STAT_KM_START_CCM_636_0_WERT", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Kilometerstand bei Aktivieren der CC-Meldung HV-System abgeschaltet (letzter Vorgang)" },
{ "STAT_ABBRUCHBEDINGUNG_0_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Abbruchbedingung CC-Meldung HV-System abgeschalte t(letzter Vorgang)" },
{ "STAT_ZEIT_START_CCM_636_1_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Startzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -1)" },
{ "STAT_ZEIT_STOP_CCM_636_1_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Stopzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -1)" },
{ "STAT_KM_START_CCM_636_1_WERT", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Kilometerstand bei Aktivieren der CC-Meldung HV-System abgeschaltet (letzter Vorgang -1)" },
{ "STAT_ABBRUCHBEDINGUNG_1_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Abbruchbedingung CC-Meldung HV-System abgeschaltet (letzter Vorgang -1)" },
{ "STAT_ZEIT_START_CCM_636_2_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Startzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -2)" },
{ "STAT_ZEIT_STOP_CCM_636_2_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Stopzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -2)" },
{ "STAT_KM_START_CCM_636_2_WERT", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Kilometerstand bei Aktivieren der CC-Meldung HV-System abgeschaltet (letzter Vorgang -2)" },
{ "STAT_ABBRUCHBEDINGUNG_2_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Abbruchbedingung CC-Meldung HV-System abgeschaltet (letzter Vorgang -2)" },
{ "STAT_ZEIT_START_CCM_636_3_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Startzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -3)" },
{ "STAT_ZEIT_STOP_CCM_636_3_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Stopzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -3)" },
{ "STAT_KM_START_CCM_636_3_WERT", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Kilometerstand bei Aktivieren der CC-Meldung HV-System abgeschaltet (letzter Vorgang -3)" },
{ "STAT_ABBRUCHBEDINGUNG_3_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Abbruchbedingung CC-Meldung HV-System abgeschaltet (letzter Vorgang -3)" },
{ "STAT_ZEIT_START_CCM_636_4_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Startzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -4)" },
{ "STAT_ZEIT_STOP_CCM_636_4_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Stopzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -4)" },
{ "STAT_KM_START_CCM_636_4_WERT", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Kilometerstand bei Aktivieren der CC-Meldung HV-System abgeschaltet (letzter Vorgang -4)" },
{ "STAT_ABBRUCHBEDINGUNG_4_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Abbruchbedingung CC-Meldung HV-System abgeschaltet (letzter Vorgang -4)" },
{ "STAT_ZEIT_START_CCM_636_5_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Startzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -5)" },
{ "STAT_ZEIT_STOP_CCM_636_5_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Stopzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -5)" },
{ "STAT_KM_START_CCM_636_5_WERT", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Kilometerstand bei Aktivieren der CC-Meldung HV-System abgeschaltet (letzter Vorgang -5)" },
{ "STAT_ABBRUCHBEDINGUNG_5_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Abbruchbedingung CC-Meldung HV-System abgeschaltet (letzter Vorgang -5)" },
{ "STAT_ZEIT_START_CCM_636_6_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Startzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -6)" },
{ "STAT_ZEIT_STOP_CCM_636_6_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Stopzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -6)" },
{ "STAT_KM_START_CCM_636_6_WERT", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Kilometerstand bei Aktivieren der CC-Meldung HV-System abgeschaltet (letzter Vorgang -6)" },
{ "STAT_ABBRUCHBEDINGUNG_6_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Abbruchbedingung CC-Meldung HV-System abgeschaltet (letzter Vorgang -6)" },
{ "STAT_ZEIT_START_CCM_636_7_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Startzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -7)" },
{ "STAT_ZEIT_STOP_CCM_636_7_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Stopzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -7)" },
{ "STAT_KM_START_CCM_636_7_WERT", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Kilometerstand bei Aktivieren der CC-Meldung HV-System abgeschaltet (letzter Vorgang -7)" },
{ "STAT_ABBRUCHBEDINGUNG_7_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Abbruchbedingung CC-Meldung HV-System abgeschaltet (letzter Vorgang -7)" },
{ "STAT_ZEIT_START_CCM_636_8_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Startzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -8)" },
{ "STAT_ZEIT_STOP_CCM_636_8_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Stopzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -8)" },
{ "STAT_KM_START_CCM_636_8_WERT", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Kilometerstand bei Aktivieren der CC-Meldung HV-System abgeschaltet (letzter Vorgang -8)" },
{ "STAT_ABBRUCHBEDINGUNG_8_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Abbruchbedingung CC-Meldung HV-System abgeschaltet (letzter Vorgang -8)" },
{ "STAT_ZEIT_START_CCM_636_9_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Startzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -9)" },
{ "STAT_ZEIT_STOP_CCM_636_9_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Stopzeit der CC-Meldung HV-System abgeschaltet (letzter Vorgang -9)" },
{ "STAT_KM_START_CCM_636_9_WERT", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Kilometerstand bei Aktivieren der CC-Meldung HV-System abgeschaltet (letzter Vorgang -9)" },
{ "STAT_ABBRUCHBEDINGUNG_9_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Abbruchbedingung CC-Meldung HV-System abgeschaltet (letzter Vorgang -9)" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE19[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ANZAHL_BREMSBTG_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Anzahl Bremsbet<65>tigungen" },
{ "STAT_LAUFZEIT_ELUP_S_WERT", "s", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Laufzeit Elup" },
{ "STAT_ANLAUFE_ELUP_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Anzahl Anl<6E>ufe Elup" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE1C[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_NV_DCDC_ALS_HIST_BEREICH_NULL_WERT", "s", "high", "unsigned long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittlicher DCDC Strom im Buckmode LV-seitig in Bereich 0" },
{ "STAT_NV_DCDC_ALS_HIST_BEREICH_1_WERT", "s", "high", "unsigned long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittlicher DCDC Strom im Buckmode LV-seitig in Bereich 1" },
{ "STAT_NV_DCDC_ALS_HIST_BEREICH_2_WERT", "s", "high", "unsigned long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittlicher DCDC Strom im Buckmode LV-seitig in Bereich 2" },
{ "STAT_NV_DCDC_ALS_HIST_BEREICH_3_WERT", "s", "high", "unsigned long", "-", "-", "0.1", "1.0", "0.0", "Zeit durchschnittlicher DCDC Strom im Buckmode LV-seitig in Bereich 3" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE74[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_SENSOR_1_NR", "0-n", "high", "unsigned char", "-", "TAB_AE_PARKSPERRE_SENSOREN", "-", "-", "-", "Status Sensor 1" },
{ "STAT_SENSOR_2_NR", "0-n", "high", "unsigned char", "-", "TAB_AE_PARKSPERRE_SENSOREN", "-", "-", "-", "Status Sensor 2" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE75[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_SPANNUNG_HV_SLE_WERT", "V", "high", "unsigned int", "-", "-", "0.2", "1.0", "0.0", "HV Spannung in der SLE" },
{ "STAT_SPANNUNG_HV_SLE_PFC_WERT", "V", "high", "unsigned int", "-", "-", "0.2", "1.0", "0.0", "SLE Power Factor Corrector Spannung" },
{ "STAT_SPANNUNG_HV_SLE_AC_WERT", "V", "high", "unsigned int", "-", "-", "0.2", "1.0", "0.0", "SLE Eingangsspannung" },
{ "STAT_SPANNUNG_HV_DCDC_WERT", "V", "high", "unsigned int", "-", "-", "0.2", "1.0", "0.0", "HV Spannung im DC/DC-Wandler" },
{ "STAT_SPANNUNG_HV_UMRICHTER_WERT", "V", "high", "unsigned int", "-", "-", "0.2", "1.0", "0.0", "HV Spannung im Umrichter" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE78[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_PARKSPERRE_EINLERNEN", "0-n", "high", "unsigned char", "-", "TAB_AE_PARKSPERRE_EINLERNEN_STATUS", "-", "-", "-", "Einlernzustand Parksperre ( 0 = nicht eingelernt; 1 = eingelernt )" },
{ "STAT_PARKSPERRE_DIAG_NR", "0-n", "high", "unsigned char", "-", "TAB_AE_PARKSPERRE_ZUSTAND", "-", "-", "-", "R<>ckmeldung bzgl. Einlernvorgang" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE7A[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_PS_POSITION_EINGELEGT_WERT", "Bit", "high", "unsigned int", "-", "-", "-", "-", "-", "Position der Parksperre eingelegt" },
{ "STAT_PS_POSITION_OFFEN_WERT", "%", "high", "unsigned int", "-", "-", "0.1", "1.0", "0.0", "Position der Parksperre offen" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE7C[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_PS_SPG_HBRUECKE_WERT", "mV", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Spannung der H-Br<42>cke" },
{ "STAT_PS_POSITION_OFFEN_WERT", "mV", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Spannung der Sensierung" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE7D[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ROHSIGNAL_ANSTEURUNG_PARKSPERRE1_WERT", "%", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Rohsignal Ansteuerung Parksperre (Duty Cycle H-Bruecke)." },
{ "STAT_ROHSIGNAL_ANSTEURUNG_PARKSPERRE2", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "Rohsignal Ansteuerung Parksperre (Richtung)." },
{ "STAT_ROHSIGNAL_ANSTEURUNG_PARKSPERRE_NOTENTRIEGELUNG", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "Rohsignal Ansteuerung Parksperre Notentrieglungsmagnet ( 0 = nicht angesteuert; 1 = angesteuert )" },
{ "STAT_ROHSIGNAL_ANSTEURUNG_ELUP_NR", "0-n", "high", "unsigned char", "-", "TAB_AE_ELUP_ROHSIGNALE", "-", "-", "-", "Rohsignal Ansteuerung ELUP." }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE7E[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ROHSIGNAL_TEMP_ENDSTUFE_ELUP_WERT", "V", "high", "unsigned long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Temperaturmessung Endstufe f<>r ELUP." },
{ "STAT_ROHSIGNAL_BUDS_WERT", "V", "high", "unsigned long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal BUDS." }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE7F[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ROHSIGNAL_TEMP_EMASCHINE_STATOR_WERT", "V", "high", "unsigned long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Temperatursensor E-Maschine Stator" },
{ "STAT_ROHSIGNAL_TEMP_UMRICHTER_PHASE_U_WERT", "V", "high", "unsigned long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Temperatursensor Umrichter Phase U." },
{ "STAT_ROHSIGNAL_TEMP_UMRICHTER_PHASE_V_WERT", "V", "high", "unsigned long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Temperatursensor Umrichter Phase V." },
{ "STAT_ROHSIGNAL_TEMP_UMRICHTER_PHASE_W_WERT", "V", "high", "unsigned long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Temperatursensor Umrichter Phase W." },
{ "STAT_ROHSIGNAL_SPANNUNG_HVDC_UMRICHTER_WERT", "V", "high", "unsigned long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal HV DC Spannung Umrichter" },
{ "STAT_ROHSIGNAL_STROM_HVDC_UMRICHTER_WERT", "A", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal HV DC Strom Umrichter." },
{ "STAT_ROHSIGNAL_STROM_U_WERT", "A", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Stromsensor Phase U." },
{ "STAT_ROHSIGNAL_STROM_V_WERT", "A", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Stromsensor Phase V." },
{ "STAT_ROHSIGNAL_STROM_W_WERT", "A", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Stromsensor Phase W." },
{ "STAT_ROHSIGNAL_ROTORLAGESENSOR_WERT", "rad", "high", "unsigned int", "-", "-", "0.0010", "1.0", "0.0", "Rotorlagesensor korrigierte elektrische Winkelposition (Radian)" },
{ "STAT_ROHSIGNAL_SPANNUNG_U_WERT", "V", "high", "unsigned long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Spannungssensor Phase U." },
{ "STAT_ROHSIGNAL_SPANNUNG_V_WERT", "V", "high", "unsigned long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Spannungssensor Phase V." },
{ "STAT_ROHSIGNAL_SPANNUNG_W_WERT", "V", "high", "unsigned long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Spannungssensor Phase W." }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE80[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ROHSIGNAL_STROM_PARKSPERRE_WERT", "A", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Strommessung Parksperre." },
{ "STAT_ROHSIGNAL_POSITION_PARKSPERRE3_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Rohsignal 3 Positionsmessung Parksperre ( 0-1000=0-100%; 2000=ungueltig)" },
{ "STAT_ROHSIGNAL_POSITION_PARKSPERRE4_WERT", "-", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "Rohsignal 4 Positionsmessung Parksperre (0-1000=0-100%; 2000=ungueltig)" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE81[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ROHSIGNAL_KL30B_WERT", "V", "high", "unsigned long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Spannungsmessung Klemme30b" },
{ "STAT_ROHSIGNAL_KL15WUO_NR", "0-n", "high", "unsigned char", "-", "TAB_AE_ROHSIGNAL_ZUSTAND", "-", "-", "-", "Rohsignal Klemme 15WUO (0 = nicht aktiv, 1 = aktiv)" },
{ "STAT_ROHSIGNAL_KL15_3_NR", "0-n", "high", "unsigned char", "-", "TAB_AE_ROHSIGNAL_ZUSTAND", "-", "-", "-", "Rohsignal Klemme 15_3 ( 0 = nicht aktiv; 1 = aktiv )" },
{ "STAT_ROHSIGNAL_KL30C_NR", "0-n", "high", "unsigned char", "-", "TAB_AE_ROHSIGNAL_ZUSTAND", "-", "-", "-", "Rohsignal Klemme 30c; elektrisch ( 0 = nicht aktiv; 1 = aktiv )" },
{ "STAT_ROHSIGNAL_CRASHSIGNAL_NR", "0-n", "high", "unsigned char", "-", "TAB_AE_ROHSIGNAL_ZUSTAND", "-", "-", "-", "Rohsignal Crasheingang Crashsignal elektrisch ( 0 = nicht aktiv; 1 = aktiv )" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE82[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ROHSIGNAL_SPANNUNG_AC_NETZ_L1_WERT", "V", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Rohsignal Spannungsmessung Phase L1 im AC Netz; Aufl<66>sung, Quantisierung, Range etc. wie in SG-interner Funktion verwendet wird." },
{ "STAT_ROHSIGNAL_SPANNUNG_AC_NETZ_L2_WERT", "V", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Rohsignal Spannungsmessung Phase L2 im AC Netz; Aufl<66>sung, Quantisierung, Range etc. wie in SG-interner Funktion verwendet wird." },
{ "STAT_ROHSIGNAL_SPANNUNG_AC_NETZ_L3_WERT", "V", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Rohsignal Spannungsmessung Phase L3 im AC Netz; Aufl<66>sung, Quantisierung, Range etc. wie in SG-interner Funktion verwendet wird." },
{ "STAT_ROHSIGNAL_STROM_AC_NETZ_L1_WERT", "A", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Rohsignal Strommessung Phase L1 im AC Netz; Aufl<66>sung, Quantisierung, Range etc. wie in SG-interner Funktion verwendet wird." },
{ "STAT_ROHSIGNAL_STROM_AC_NETZ_L2_WERT", "A", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Rohsignal Strommessung Phase L2 im AC Netz; Aufl<66>sung, Quantisierung, Range etc. wie in SG-interner Funktion verwendet wird." },
{ "STAT_ROHSIGNAL_STROM_AC_NETZ_L3_WERT", "A", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Rohsignal Strommessung Phase L3 im AC Netz; Aufl<66>sung, Quantisierung, Range etc. wie in SG-interner Funktion verwendet wird." },
{ "STAT_ROHSIGNAL_FREQUENZ_AC_NETZ_L1_WERT", "Hz", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Rohsignal Frequenzmessung Phase L1 im AC Netz; Aufl<66>sung, Quantisierung, Range etc. wie in SG-interner Funktion verwendet wird." },
{ "STAT_ROHSIGNAL_FREQUENZ_AC_NETZ_L2_WERT", "Hz", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Rohsignal Frequenzmessung Phase L2 im AC Netz; Aufl<66>sung, Quantisierung, Range etc. wie in SG-interner Funktion verwendet wird." },
{ "STAT_ROHSIGNAL_FREQUENZ_AC_NETZ_L3_WERT", "Hz", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Rohsignal Frequenzmessung Phase L3 im AC Netz; Aufl<66>sung, Quantisierung, Range etc. wie in SG-interner Funktion verwendet wird." },
{ "STAT_ROHSIGNAL_E_S_CHARGE_EN_WERT", "-", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Rohsignal Charge Enable Leitung; Aufl<66>sung, Quantisierung, Range etc. wie in SG-interner Funktion verwendet wird." }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE83[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ROHSIGNAL_SPANNUNG_LV_DCDC_WERT", "V", "high", "unsigned long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Spannungsmessung LV DCDC Wandler." },
{ "STAT_ROHSIGNAL_STROM_LV_DCDC_WERT", "A", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Strommessung LV DCDC Wandler." },
{ "STAT_ROHSIGNAL_STROM_HV_DCDC_WERT", "A", "high", "long", "-", "-", "0.0010", "1.0", "0.0", "Rohsignal Strommessung HV DCDC Wandler." }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE84[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_NETZFREQUENZ_PHASE_1_WERT", "-", "high", "unsigned int", "-", "-", "0.25", "1.0", "0.0", "Aktuelle Netzfrequenz Phase 1" },
{ "STAT_LADEDAUER_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "R<>ckgabe der im aktuellen Ladezyklus verstrichenen Ladezeit" },
{ "STAT_FEHLERZUSTAND_NR", "0-n", "high", "unsigned char", "-", "TAB_AE_SLE_FEHLERZUSTAENDE", "-", "-", "-", "SLE Fehlerzust<73>nde: 0=Derating 1=Ladeunterbrechung 2=Notlauf 3=Kommunikationsausfall 4=Reserviert 255 Signal ung<6E>ltig" },
{ "STAT_SLE_DERATING_WERT", "%", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Wert, um den die DC-HV-Ausgangsleistung reduziert ist. 0-254%" },
{ "STAT_BETRIEBSART_NR", "0-n", "high", "unsigned char", "-", "TAB_AE_SLE_BETRIEBSMODE", "-", "-", "-", "Betriebsart: 1=Standby 2=HV-DC Laden 3=Reserviert 15 Signal ung<6E>ltig" },
{ "STAT_WIRKUNGSGRAD_LADEZYKLUS_WERT", "%", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Wirkungsgrad Ladezyklus" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE85[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_SLE_DC_HV_LEISTUNG_WERT", "W", "high", "unsigned int", "-", "-", "1.0", "1.0", "-30000.0", "Abgegebende Momentanleistung in den Zwischenkreis" },
{ "STAT_SLE_DC_HV_LEISTUNG_MAX_WERT", "W", "high", "unsigned int", "-", "-", "1.0", "1.0", "-30000.0", "Maximal abgebbare Leistung in den Zwischenkreis" },
{ "STAT_SLE_AC_WIRKLEISTUNG_WERT", "W", "high", "unsigned int", "-", "-", "1.0", "1.0", "-30000.0", "Entnommene Momentanwirkleistung aus dem Netz" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE86[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_SPANNUNG_RMS_AC_PHASE_1_WERT", "V", "high", "unsigned int", "-", "-", "0.1", "1.0", "0.0", "Effektivwerte der AC Leiterspannungen (Phase1)" },
{ "STAT_SPANNUNG_SLE_DC_HV_WERT", "V", "high", "unsigned int", "-", "-", "0.1", "1.0", "0.0", "SLE DC HV Spannung" },
{ "STAT_SPANNUNG_SLE_DC_HV_OBERGRENZE_WERT", "V", "high", "unsigned int", "-", "-", "0.1", "1.0", "0.0", "SLE DC HV Spannungsobergrenze" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE87[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_STROM_PCF_SUM_WERT", "A", "high", "unsigned int", "-", "-", "0.01", "1.0", "-100.0", "kalibrierter SLE Power Corrector Factor Summenstrom" },
{ "STAT_STROM_PCF1_WERT", "A", "high", "unsigned int", "-", "-", "0.01", "1.0", "-100.0", "kalibrierter SLE Power Corrector Factor1 Strom" },
{ "STAT_STROM_PCF2_WERT", "A", "high", "unsigned int", "-", "-", "0.01", "1.0", "-100.0", "kalibrierter SLE Power Corrector Factor2 Strom" },
{ "STAT_STROM_TRAFO_WERT", "A", "high", "unsigned int", "-", "-", "0.01", "1.0", "-100.0", "kalibrierter SLE Trafostrom" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE89[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_STROM_DCDC_WANDLER_HV_WERT", "A", "high", "unsigned int", "-", "-", "0.05", "1.0", "-100.0", "Strom des DCDC-Wandlers auf der HV-Seite" },
{ "STAT_STROM_DCDC_WANDLER_12V_WERT", "A", "high", "unsigned int", "-", "-", "1.0", "1.0", "-1000.0", "Strom des DCDC-Wandlers auf der 12V-Seite" },
{ "STAT_STROM_DCDC_TS1_WERT", "A", "high", "unsigned int", "-", "-", "0.01", "1.0", "0.0", "DC/DC Tiefsetzsteller-Strom 1" },
{ "STAT_STROM_DCDC_TS2_WERT", "A", "high", "unsigned int", "-", "-", "0.01", "1.0", "0.0", "DC/DC Tiefsetzsteller-Strom 2" },
{ "STAT_STROM_DCDC_TRAFO1_WERT", "A", "high", "unsigned int", "-", "-", "0.01", "1.0", "0.0", "DC/DC Trafostrom 1" },
{ "STAT_STROM_DCDC_TRAFO2_WERT", "A", "high", "unsigned int", "-", "-", "0.01", "1.0", "0.0", "DC/DC Trafostrom 2" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE8B[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_STROM_DCDC_HV_IST_MAX_WERT", "A", "high", "unsigned int", "-", "-", "0.05", "1.0", "-100.0", "Maximaler betragsm<73><6D>iger HV Stroms des DCDC-Wandlers" },
{ "STAT_STROM_DCDC_LV_IST_MAX_WERT", "A", "high", "unsigned int", "-", "-", "1.0", "1.0", "-512.0", "Maximaler betragsm<73><6D>iger LV Stroms DCDC-Wandler" },
{ "STAT_STROM_EKMV_MAX_WERT", "A", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Maximaler Strom zum eKMV" },
{ "STAT_ERREGERSTROM_MAX_WERT", "A", "high", "unsigned int", "-", "-", "0.1", "1.0", "0.0", "Maximaler Erregerstrom der Emaschine" },
{ "STAT_STROM_DC_HV_UMRICHTER_MOTOR_WERT", "A", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Max. HV-DC Strom des Umrichters f<>r den EM-Stator im motorischen Betrieb" },
{ "STAT_STROM_DC_HV_UMRICHTER_GENERATOR_WERT", "A", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Max. HV-DC Strom des Umrichters f<>r den EM-Stator im generatorischem Betrieb" },
{ "STAT_STROM_SLE_DC_HV_IST_MAX_WERT", "A", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Maximaler betragsm<73><6D>iger HV Stroms der SLE DC HV" },
{ "STAT_STROM_SLE_AC_RMS_IST_MAX_WERT", "A", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Maximaler betragsm<73><6D>iger HV Stroms der SLE AC RMS" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE8C[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_TEMP_UMRICHTER_PHASE_U_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur Umrichter Phase U" },
{ "STAT_TEMP_UMRICHTER_PHASE_V_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur Umrichter Phase V" },
{ "STAT_TEMP_UMRICHTER_PHASE_W_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur Umrichter Phase W" },
{ "STAT_TEMP_UMRICHTER_GT_PHASE_U_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur Inverter Gatedriver Phase U" },
{ "STAT_TEMP_UMRICHTER_GT_PHASE_V_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur Inverter Gatedriver Phase U" },
{ "STAT_TEMP_UMRICHTER_GT_PHASE_W_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur Inverter Gatedriver Phase W" },
{ "STAT_TEMP_UMRICHTER_MUX_ADC_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur am MUX_ADC des Inverters" },
{ "STAT_TEMP_DCDC_BO_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur des DCDC Boards" },
{ "STAT_TEMP_DCDC_GTW_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur DC/DC-Gegentaktwandler" },
{ "STAT_TEMP_DCDC_TS_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur DC/DC-Tiefsetzer" },
{ "STAT_TEMP_DCDC_GR_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur des DCDC Boards" },
{ "STAT_TEMP_SLE_PFC_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur SLE-PowerFactorCorrection" },
{ "STAT_TEMP_SLE_GR_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur SLE-Gleichrichter" },
{ "STAT_TEMP_SLE_GTW_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur SLE-Gegentaktwandler" },
{ "STAT_TEMP_SLE_BO_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur des SLE Boards" },
{ "STAT_TEMP_ELUP_LE_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur auf dem Powerbord - Messstelle ELUP Leistungsendstufe" },
{ "STAT_TEMP_DIG_CY320_MC0_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur auf dem Digitalbord am CY320_MC0" },
{ "STAT_TEMP_DIG_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur auf dem Digitalbord" },
{ "STAT_TEMP_DIG_CY320_MC2_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur auf dem Digitalbord am CY320_MC2" },
{ "STAT_TEMP_PROZESSOR_MC0_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur Prozessor MC0" },
{ "STAT_TEMP_PROZESSOR_MC2_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "Temperatur Prozessor MC2" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE92[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_BETRIEBSART_DCDC_IST", "0-n", "high", "unsigned char", "-", "TAB_AE_ZST_AKTIV_NAKTIV", "-", "-", "-", "Ist-Betriebsart des DCDC-Wandlers" },
{ "STAT_SPANNUNG_LV_IST_WERT", "V", "high", "unsigned int", "-", "-", "0.05", "1.0", "0.0", "-" },
{ "STAT_AUSLASTUNG_WERT", "%", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Auslastung des DCDC-Wandlers" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE93[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ELUP_ANSTEUERUNG", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "Aktueller Schaltzustand der ELUP ( 0 = aus; 1 = an )" },
{ "STAT_ELUP_SPANNUNG_WERT", "V", "high", "unsigned char", "-", "-", "0.1", "1.0", "0.0", "Spannung am ELUP Ausgang" },
{ "STAT_ELUP_STROM_WERT", "A", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Strom am ELUP-Ausgang" },
{ "STAT_ELUP_TEMP_WERT", "<22>C", "high", "unsigned char", "-", "-", "1.0", "1.0", "-40.0", "Temperatur des ELUP-Treibers" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE96[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_FEHLER_BIT0_EIN", "0/1", "high", "unsigned int", "0x0001", "-", "-", "-", "-", "Diagnosestatus des DCDC-Wandler: Bit 0: Shutdown Undervoltage 0=nicht aktiv 1=aktiv" },
{ "STAT_FEHLER_BIT1_EIN", "0/1", "high", "unsigned int", "0x0002", "-", "-", "-", "-", "Diagnosestatus des DCDC-Wandler: Bit 1: Shutdown Overvoltage 0=nicht aktiv 1=aktiv" },
{ "STAT_FEHLER_BIT2_EIN", "0/1", "high", "unsigned int", "0x0004", "-", "-", "-", "-", "Diagnosestatus des DCDC-Wandler: Bit 2: Shutdown Overtemperature 0=nicht aktiv 1=aktiv" },
{ "STAT_FEHLER_BIT3_EIN", "0/1", "high", "unsigned int", "0x0008", "-", "-", "-", "-", "Diagnosestatus des DCDC-Wandler: Bit 3: Shutdown Overcurrent 0=nicht aktiv 1=aktiv" },
{ "STAT_FEHLER_BIT4_EIN", "0/1", "high", "unsigned int", "0x0010", "-", "-", "-", "-", "Diagnosestatus des DCDC-Wandler: Bit 4: Interlock Fault 0=nicht aktiv 1=aktiv" },
{ "STAT_FEHLER_BIT5_EIN", "0/1", "high", "unsigned int", "0x0020", "-", "-", "-", "-", "Diagnosestatus des DCDC-Wandler: Bit 5: Not in commanded mode 0=nicht aktiv 1=aktiv" },
{ "STAT_FEHLER_BIT6_EIN", "0/1", "high", "unsigned int", "0x0040", "-", "-", "-", "-", "Diagnosestatus des DCDC-Wandler: Bit 6: Genereller HW-Fehler (Err_State) 0=nicht aktiv 1=aktiv" },
{ "STAT_FEHLER_BIT7_EIN", "0/1", "high", "unsigned int", "0x0080", "-", "-", "-", "-", "Diagnosestatus des DCDC-Wandler: Bit 7: -Vorhalt- Verfeinerung HW-Fehler 1 0=nicht aktiv 1=aktiv" },
{ "STAT_FEHLER_BIT8_EIN", "0/1", "high", "unsigned int", "0x0100", "-", "-", "-", "-", "Diagnosestatus des DCDC-Wandler: Bit 8: -Vorhalt- Verfeinerung HW-Fehler 2 0=nicht aktiv 1=aktiv" },
{ "STAT_FEHLER_BIT9_EIN", "0/1", "high", "unsigned int", "0x0200", "-", "-", "-", "-", "Diagnosestatus des DCDC-Wandler: Bit9: -Vorhalt- Verfeinerung HW-Fehler 3 0=nicht aktiv 1=aktiv" },
{ "STAT_FEHLER_BIT10_EIN", "0/1", "high", "unsigned int", "0x0400", "-", "-", "-", "-", "Diagnosestatus des DCDC-Wandler: Bit10: -Vorhalt- Verfeinerung HW-Fehler 4 0=nicht aktiv 1=aktiv" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDE9E[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_LADEN_NR", "0-n", "high", "unsigned char", "-", "TAB_EDME_STATUS_LADEN", "-", "-", "-", "Information <20>ber den aktuellen Status des Ladens (siehe TAB_EDME_STATUS_LADEN)" },
{ "STAT_REMOTE_LADEN_NR", "0-n", "high", "unsigned char", "-", "TAB_EDME_REMOTE_LADEN", "-", "-", "-", "Bit0: RemoteLaden nicht aktiv Bit1: RemoteLaden on Hold Bit2: RemoteLaden aktiv" },
{ "STAT_TIMER_LADEN_NR", "0-n", "high", "unsigned char", "-", "TAB_EDME_TIMER_LADEN_NR", "-", "-", "-", "Bit0: TimerLaden nicht aktiv Bit1: TimerLaden on Hold Bit2: TimerLaden aktiv" },
{ "STAT_HV_SOC_WERT", "%", "high", "unsigned char", "-", "-", "0.5", "1.0", "0.0", "Anzeige Ladezustand HV-Batterie" },
{ "STAT_ZEIT_LADEENDE_WERT", "min", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Ladedauer" },
{ "STAT_MAX_LADESTROM_LADEGERAET_WERT", "A", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Maximaler AC-Ladestrom Ladeger<65>t" },
{ "STAT_IST_AC_SPANNUNG_LADEGERAET_WERT", "V", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ist-AC-Spannung Ladeger<65>t" },
{ "STAT_REICHWEITE_WERT", "km", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Reichweite" },
{ "STAT_HVB_TEMP_WERT", "<22>", "high", "int", "-", "-", "0.1", "1.0", "0.0", "Temperatur der HV-Batterie" },
{ "STAT_TRIGGER_SEGMENTSPEICHER_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ausl<73>sebedingung f<>r das Lesen des Segmentspeichers" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDEA0[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ANZ_LADEVORGAENGE_GESAMT_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Anzahl Ladevorg<72>nge seit letztem TSR" },
{ "STAT_ANZ_LADEVORGAENGE_REG_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Anzahl Ladevorg<72>nge seit letztem TSR gr<67><72>er eine Minute" },
{ "STAT_TIME_LADEBEGINN_HR_WERT", "h", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Uhrzeit bei Ladebeginn (Kombi) Stunde" },
{ "STAT_TIME_LADEBEGINN_MIN_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Uhrzeit bei Ladebeginn (Kombi) Minute" },
{ "STAT_KM_STAND_LADEBEGINN_WERT", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "km-Stand bei Ladebeginn" },
{ "STAT_DELTA_RANGE_WERT", "km", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Differenz Reichweitenprognose zu letztem Ladeende und aktuellem Ladebeginn" },
{ "STAT_DELTA_KM_STAND_WERT", "km", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Differenz km-Stand seit letztem Ladeende und aktuellem Ladebeginn" },
{ "STAT_DELTA_SOC_WERT", "%", "high", "int", "-", "-", "0.1", "1.0", "0.0", "SoC-Hub zwischen letztem Ladevorgang und aktuellem Ladebeginn" },
{ "STAT_SOC_LADEBEGINN_WERT", "%", "high", "int", "-", "-", "0.1", "1.0", "0.0", "HV-SoC bei Ladebeginn" },
{ "STAT_SOC_LADEENDE_WERT", "%", "high", "int", "-", "-", "0.1", "1.0", "0.0", "HV-SoC bei Ladeende" },
{ "STAT_ABBRUCHBED_LADEN_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Start- und Abbruchbedingung Laden" },
{ "STAT_LADEDAUER_GESAMT_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer Ladevorgang gesamt" },
{ "STAT_LADEDAUER_EFFEKTIV_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer Ladevorgang ohne Ladeunterbrechungen" },
{ "STAT_ANZ_LADEUNTERBR_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Anzahl Ladeunterbrechungen" },
{ "STAT_REAS_LDUNTERBR_WERT", "-", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Ursache f<>r die letzten 4 Ladeunterbrechungen" },
{ "STAT_PROGNOSE_LADEDAUER_WERT", "min", "high", "unsigned int", "-", "-", "5.0", "1.0", "0.0", "Prognostizierte Ladedauer zu Ladebeginn" },
{ "STAT_DAUER_DER_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Deratings" },
{ "STAT_MIN_VALUE_DER_WERT", "W", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Minimal auftretender Wert w<>hrend Derating" },
{ "STAT_DERATING_PROZENTUAL_WERT", "%", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Mittlerer Wert des Deratings" },
{ "STAT_I_LIM_GRID_WERT", "A", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Netzseitige Stromgrenze" },
{ "STAT_T_AMB_LADEBEGINN_WERT", "<22>C", "high", "int", "-", "-", "0.5", "1.0", "0.0", "Umgebungstemperatur Ladebeginn" },
{ "STAT_T_AMB_LADEENDE_WERT", "<22>C", "high", "int", "-", "-", "0.5", "1.0", "0.0", "Umgebungstemperatur Ladeende" },
{ "STAT_T_HVB_LADEBEGINN_WERT", "<22>C", "high", "int", "-", "-", "1.0", "1.0", "0.0", "Temperatur HV-Batterie" },
{ "STAT_T_HVB_LADEENDE_WERT", "<22>C", "high", "int", "-", "-", "1.0", "1.0", "0.0", "Temperatur HV-Batterie Ladeende" },
{ "STAT_U_GRID_MIN_WERT", "V", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Minimale Netzspannung" },
{ "STAT_U_GRID_MAX_WERT", "V", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Maximale Netzspannung" },
{ "STAT_HIST_P_KLE_0_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall 0-1 kW" },
{ "STAT_HIST_P_KLE_1_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall 1-2 kW" },
{ "STAT_HIST_P_KLE_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall 2-3 kW" },
{ "STAT_HIST_P_KLE_3_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall 3-4 kW" },
{ "STAT_HIST_P_KLE_4_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall 4-5 kW" },
{ "STAT_HIST_P_KLE_5_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall 5-6 kW" },
{ "STAT_HIST_P_KLE_6_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall > 6 kW" },
{ "STAT_ENERGIE_KLE_WERT", "Ws", "high", "unsigned int", "-", "-", "3600.0", "1.0", "0.0", "Energieverbrauch KLE" },
{ "STAT_HIST_P_EKMV_EDH_0_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs von EKMV und EDH im Intervall 0-1 kW" },
{ "STAT_HIST_P_EKMV_EDH_1_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs von EKMV und EDH im Intervall 1-2 kW" },
{ "STAT_HIST_P_EKMV_EDH_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs von EKMV und EDH im Intervall 2-3 kW" },
{ "STAT_HIST_P_EKMV_EDH_3_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs von EKMV und EDH im Intervall 3-4 kW" },
{ "STAT_HIST_P_EKMV_EDH_4_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs von EKMV und EDH im Intervall 4-5 kW" },
{ "STAT_HIST_P_EKMV_EDH_5_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs von EKMV und EDH im Intervall > 5 kW" },
{ "STAT_ENERGIE_EDH_EKMV_WERT", "Ws", "high", "unsigned int", "-", "-", "3600.0", "1.0", "0.0", "Energieverbrauch EDH und EKMV" },
{ "STAT_ANF_ART_VOKO_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Bit0: Voko Innenraum Bit1: Voko Innenraum forced Bit2: Voko Batt Bit3: Voko Batt forced" },
{ "STAT_HIST_P_HVB_0_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB < -4 kW" },
{ "STAT_HIST_P_HVB_1_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB -4 kW bis -3 kW" },
{ "STAT_HIST_P_HVB_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB -3 kW bis -2 kW" },
{ "STAT_HIST_P_HVB_3_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB -2 kW bis -1 kW" },
{ "STAT_HIST_P_HVB_4_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB -1 kW bis 0 kW" },
{ "STAT_HIST_P_HVB_5_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 0 kW bis 1 kW" },
{ "STAT_HIST_P_HVB_6_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 1 kW bis 2 kW" },
{ "STAT_HIST_P_HVB_7_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 2 kW bis 3 kW" },
{ "STAT_HIST_P_HVB_8_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 3 kW bis 4 kW" },
{ "STAT_HIST_P_HVB_9_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 4 kW bis 5 kW" },
{ "STAT_HIST_P_HVB_10_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 5 kW bis 6 kW" },
{ "STAT_HIST_P_HVB_11_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 6 kW bis 7 kW" },
{ "STAT_HIST_P_HVB_12_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB > 7 kW" },
{ "STAT_ENERGIE_HVB_WERT", "Ws", "high", "unsigned int", "-", "-", "3600.0", "1.0", "0.0", "Energieverbrauch HVB" },
{ "STAT_P_AVG_DCDC_HV_WERT", "W", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Durchschnittliche Leistung DCDC-Wandler HV-seitig" },
{ "STAT_DAUER_SPANNUNGSGRENZE_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer in Spannungsbegrenzung w<>hrend Ladevorgang" },
{ "STAT_SOC_SPANNUNGSGRENZE_WERT", "%", "high", "int", "-", "-", "0.1", "1.0", "0.0", "SoC bei der Spannungsgrenze erreicht wird" },
{ "STAT_TIME_LADEBEGINN_HR_2_WERT", "h", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Uhrzeit bei Ladebeginn (Kombi) Stunde 2" },
{ "STAT_TIME_LADEBEGINN_MIN_2_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Uhrzeit bei Ladebeginn (Kombi) Minute 2" },
{ "STAT_KM_STAND_LADEBEGINN_2_WERT", "km", "high", "unsigned long", "-", "-", "1.0", "1.0", "0.0", "km-Stand bei Ladebeginn 2" },
{ "STAT_DELTA_RANGE_2_WERT", "km", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Differenz Reichweitenprognose zu letztem Ladeende und aktuellem Ladebeginn 2" },
{ "STAT_DELTA_KM_STAND_2_WERT", "km", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Differenz km-Stand seit letztem Ladeende und aktuellem Ladebeginn 2" },
{ "STAT_DELTA_SOC_2_WERT", "%", "high", "int", "-", "-", "0.1", "1.0", "0.0", "SoC-Hub zwischen letztem Ladevorgang und aktuellem Ladebeginn 2" },
{ "STAT_SOC_LADEBEGINN_2_WERT", "%", "high", "int", "-", "-", "0.1", "1.0", "0.0", "HV-SoC bei Ladebeginn 2" },
{ "STAT_SOC_LADEENDE_2_WERT", "%", "high", "int", "-", "-", "0.1", "1.0", "0.0", "HV-SoC bei Ladeende 2" },
{ "STAT_ABBRUCHBED_LADEN_2_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Start- und Abbruchbedingung Laden 2" },
{ "STAT_LADEDAUER_GESAMT_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer Ladevorgang gesamt 2" },
{ "STAT_LADEDAUER_EFFEKTIV_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer Ladevorgang ohne Ladeunterbrechungen 2" },
{ "STAT_ANZ_LADEUNTERBR_2_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Anzahl Ladeunterbrechungen 2" },
{ "STAT_REAS_LDUNTERBR_2_WERT", "-", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Ursache f<>r die letzten 4 Ladeunterbrechungen 2" },
{ "STAT_PROGNOSE_LADEDAUER_2_WERT", "min", "high", "unsigned int", "-", "-", "5.0", "1.0", "0.0", "Prognostizierte Ladedauer zu Ladebeginn 2" },
{ "STAT_DAUER_DER_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Deratings 2" },
{ "STAT_MIN_VALUE_DER_2_WERT", "W", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Minimal auftretender Wert w<>hrend Derating 2" },
{ "STAT_DERATING_PROZENTUAL_2_WERT", "%", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Mittlerer Wert des Deratings 2" },
{ "STAT_I_LIM_GRID_2_WERT", "A", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Netzseitige Stromgrenze 2" },
{ "STAT_T_AMB_LADEBEGINN_2_WERT", "<22>C", "high", "int", "-", "-", "0.5", "1.0", "0.0", "Umgebungstemperatur Ladebeginn 2" },
{ "STAT_T_AMB_LADEENDE_2_WERT", "<22>C", "high", "int", "-", "-", "0.5", "1.0", "0.0", "Umgebungstemperatur Ladeende 2" },
{ "STAT_T_HVB_LADEBEGINN_2_WERT", "<22>C", "high", "int", "-", "-", "1.0", "1.0", "0.0", "Temperatur HV-Batterie 2" },
{ "STAT_T_HVB_LADEENDE_2_WERT", "<22>C", "high", "int", "-", "-", "1.0", "1.0", "0.0", "Temperatur HV-Batterie Ladeende 2" },
{ "STAT_U_GRID_MIN_2_WERT", "V", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Minimale Netzspannung 2" },
{ "STAT_U_GRID_MAX_2_WERT", "V", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Maximale Netzspannung 2" },
{ "STAT_HIST_P_KLE_0_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall 0-1 kW 2" },
{ "STAT_HIST_P_KLE_1_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall 1-2 kW 2" },
{ "STAT_HIST_P_KLE_2_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall 2-3 kW 2" },
{ "STAT_HIST_P_KLE_3_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall 3-4 kW 2" },
{ "STAT_HIST_P_KLE_4_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall 4-5 kW 2" },
{ "STAT_HIST_P_KLE_5_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall 5-6 kW 2" },
{ "STAT_HIST_P_KLE_6_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs KLE im Intervall > 6 kW 2" },
{ "STAT_ENERGIE_KLE_2_WERT", "Ws", "high", "unsigned int", "-", "-", "3600.0", "1.0", "0.0", "Energieverbrauch KLE 2" },
{ "STAT_HIST_P_EKMV_EDH_0_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs von EKMV und EDH im Intervall 0-1 kW 2" },
{ "STAT_HIST_P_EKMV_EDH_1_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs von EKMV und EDH im Intervall 1-2 kW 2" },
{ "STAT_HIST_P_EKMV_EDH_2_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs von EKMV und EDH im Intervall 2-3 kW 2" },
{ "STAT_HIST_P_EKMV_EDH_3_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs von EKMV und EDH im Intervall 3-4 kW 2" },
{ "STAT_HIST_P_EKMV_EDH_4_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs von EKMV und EDH im Intervall 4-5 kW 2" },
{ "STAT_HIST_P_EKMV_EDH_5_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfs von EKMV und EDH im Intervall > 5 kW 2" },
{ "STAT_ENERGIE_EDH_EKMV_2_WERT", "Ws", "high", "unsigned int", "-", "-", "3600.0", "1.0", "0.0", "Energieverbrauch EDH und EKMV 2" },
{ "STAT_ANF_ART_VOKO_2_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Bit0: Voko Innenraum_2 Bit1: Voko Innenraum forced_2 Bit2: Voko Batt_2 Bit3: Voko Batt forced_2" },
{ "STAT_HIST_P_HVB_0_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB < -4 kW 2" },
{ "STAT_HIST_P_HVB_1_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB -4 kW bis -3 kW 2" },
{ "STAT_HIST_P_HVB_2_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB -3 kW bis -2 kW 2" },
{ "STAT_HIST_P_HVB_3_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB -2 kW bis -1 kW 2" },
{ "STAT_HIST_P_HVB_4_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB -1 kW bis 0 kW 2" },
{ "STAT_HIST_P_HVB_5_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 0 kW bis 1 kW 2" },
{ "STAT_HIST_P_HVB_6_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 1 kW bis 2 kW 2" },
{ "STAT_HIST_P_HVB_7_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 2 kW bis 3 kW 2" },
{ "STAT_HIST_P_HVB_8_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 3 kW bis 4 kW 2" },
{ "STAT_HIST_P_HVB_9_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 4 kW bis 5 kW 2" },
{ "STAT_HIST_P_HVB_10_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 5 kW bis 6 kW 2" },
{ "STAT_HIST_P_HVB_11_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB 6 kW bis 7 kW 2" },
{ "STAT_HIST_P_HVB_12_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer des Leistungsbedarfes der HVB > 7 kW 2" },
{ "STAT_ENERGIE_HVB_2_WERT", "Ws", "high", "unsigned int", "-", "-", "3600.0", "1.0", "0.0", "Energieverbrauch HVB 2" },
{ "STAT_P_AVG_DCDC_HV_2_WERT", "W", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Durchschnittliche Leistung DCDC-Wandler HV-seitig 2" },
{ "STAT_DAUER_SPANNUNGSGRENZE_2_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer in Spannungsbegrenzung w<>hrend Ladevorgang 2" },
{ "STAT_SOC_SPANNUNGSGRENZE_2_WERT", "%", "high", "int", "-", "-", "0.1", "1.0", "0.0", "SoC bei der Spannungsgrenze erreicht wird 2" },
{ "STAT_ANZ_NACHLADEANF_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Anzahl Nachladeanforderungen seit letztem TSR" },
{ "STAT_DAUER_NACHLADEANF_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer der letzen Nachladeanforderung" },
{ "STAT_P_LADE_AVG_NVB_WERT", "W", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Durchschnittliche Ladeleistung NVB w<>hrend Nachladeanforderung" },
{ "STAT_P_LADE_AVG_DCDC_HV_WERT", "W", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Durchschnittliche Leistung DCDC-Wandler HV-seitig w<>hrend Nachladeanforderung" },
{ "STAT_ZUSATZINFO_NACHLADEANF_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Bit0: Nachladeanforderung nach Wecken durch IBS Bit1: Ladevorgang bei Fahrzeug wach Bit2: Vorbehalt Bit3: Vorbehalt Bit4: HVB-SoC min. unterschritten Bit5: Min. Nachladestrom NVB unterschritten Bit6: Abbruch durch St_kl_15 Bit7: Schlechte Ladebilanz" },
{ "STAT_GESAMTDAUER_NACHLAUF_WERT", "s", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Aufsummierte Nachlaufdauer seit letzten TSR" },
{ "STAT_P_AVG_DCDC_INSGESAMT_WERT", "W", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Durchschnittliche Leistung DCDC-Wandler w<>hrend Nachlauf" },
{ "STAT_P_AVG_BATT_INSGESAMT_WERT", "W", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Durchschnittliche Ladeleistung NVB w<>hrend Nachlauf" },
{ "STAT_DELTA_SOC_STANDZEIT_1_WERT", "%", "high", "int", "-", "-", "0.1", "1.0", "0.0", "<22>nderung SoC <20>ber Standzeit_1" },
{ "STAT_DAUER_STANDZEIT_1_WERT", "min", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer Standzeit_1" },
{ "STAT_DELTA_SOC_STANDZEIT_2_WERT", "%", "high", "int", "-", "-", "0.1", "1.0", "0.0", "<22>nderung SoC <20>ber Standzeit_2" },
{ "STAT_DAUER_STANDZEIT_2_WERT", "min", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Dauer Standzeit_2" },
{ "STAT_REAS_DERATING_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ursache(n) des Deratings Bit0: <20>bertemperatur Bit1: Netzfrequenz zu niedrig Bit2: Ausfall eines Lademoduls Bit3: DC-Strombegrenzung Bit4: Netzseitig verf<72>gbare Leistung kleiner Nennleistung" },
{ "STAT_REAS_DERATING_2_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Ursache(n) des Deratings Bit0: <20>bertemperatur Bit1: Netzfrequenz zu niedrig Bit2: Ausfall eines Lademoduls Bit3: DC-Strombegrenzung Bit4: Netzseitig verf<72>gbare Leistung kleiner Nennleistung" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDEA6[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_TEMP1_E_MOTOR_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "E-Motor Temperatur 1" },
{ "STAT_TEMP2_E_MOTOR_WERT", "<22>C", "high", "int", "-", "-", "0.0156", "1.0", "0.0", "E-Motor Temperatur 2" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDEA7[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ELEKTRISCHE_MASCHINE_DREHZAHL_WERT", "1/min", "high", "unsigned int", "-", "-", "0.5", "1.0", "-5000.0", "Drehzahl der E-Maschine" },
{ "STAT_ELEKTRISCHE_MASCHINE_IST_MOMENT_WERT", "Nm", "high", "int", "-", "-", "0.5", "1.0", "0.0", "IST Moment der E-Maschine" },
{ "STAT_ELEKTRISCHE_MASCHINE_SOLL_MOMENT_WERT", "Nm", "high", "int", "-", "-", "0.5", "1.0", "0.0", "SOLL Moment der E-Maschine" },
{ "STAT_ELEKTRISCHE_BETRIEBSART_NR", "0-n", "high", "unsigned char", "-", "TAB_AE_ELEKTRISCHE_BETRIEBSART", "-", "-", "-", "aktuelle Betriebsart der E-Maschine" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDEA9[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_DIAG_BIT0", "0/1", "high", "unsigned int", "0x0001", "-", "-", "-", "-", "Limitierung durch die kommandierte Leistungsgrenze: 0=nicht aktiv 1=aktiv" },
{ "STAT_DIAG_BIT1", "0/1", "high", "unsigned int", "0x0002", "-", "-", "-", "-", "Limitierung der Ausgangsleistung wegen Spannungskriterium: 0=nicht aktiv 1=aktiv" },
{ "STAT_DIAG_BIT2", "0/1", "high", "unsigned int", "0x0004", "-", "-", "-", "-", "Limitierung durch kommandierte Minimalspannung auf HV-Seite: 0=nicht aktiv 1=aktiv" },
{ "STAT_DIAG_BIT3", "0/1", "high", "unsigned int", "0x0008", "-", "-", "-", "-", "Limitierung wegen Temperaturkriterium: 0=nicht aktiv 1=aktiv" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDEB0[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_PS_VERSION_MAIN_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Main-Version Parksperren-SW" },
{ "STAT_PS_VERSION_SUB_WERT", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Revision Parksperren-SW" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDEB5[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_DCDC_SW_VERSION_WERT", "-", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Softwareversion des DCDC Pics" },
{ "STAT_SLE_SW_VERSION_WERT", "-", "high", "unsigned int", "-", "-", "1.0", "1.0", "0.0", "Softwareversion des SLE Pics" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDEBD[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_SPANNUNG_GT_WERT", "V", "high", "unsigned int", "-", "-", "0.0010", "1.0", "0.0", "DC/DC Gatetreiber Spannung" },
{ "STAT_SPANNUNG_LV_WERT", "V", "high", "unsigned int", "-", "-", "0.0010", "1.0", "0.0", "DC/DC-Spannung Niedervoltseite" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDEBE[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_SPANNUNG_CY0_5V0_WERT", "V", "high", "unsigned int", "-", "-", "0.0010", "1.0", "0.0", "Spannungs<67>berwachung der internen 5V von CY320_MC0" },
{ "STAT_SPANNUNG_CY2_5V0_WERT", "V", "high", "unsigned int", "-", "-", "0.0010", "1.0", "0.0", "Spannungs<67>berwachung der internen 5V von CY320_MC2" },
{ "STAT_SPANNUNG_CY0_3V3_WERT", "V", "high", "unsigned int", "-", "-", "0.0010", "1.0", "0.0", "Spannungs<67>berwachung der internen 3,3V von CY320_MC0" },
{ "STAT_SPANNUNG_CY2_3V3_WERT", "V", "high", "unsigned int", "-", "-", "0.0010", "1.0", "0.0", "Spannungs<67>berwachung der internen 3,3V von CY320_MC2" },
{ "STAT_SPANNUNG_CY0_1V5_WERT", "V", "high", "unsigned int", "-", "-", "0.0010", "1.0", "0.0", "Spannungs<67>berwachung der internen 1,5V von CY320_MC0" },
{ "STAT_SPANNUNG_CY2_1V5_WERT", "V", "high", "unsigned int", "-", "-", "0.0010", "1.0", "0.0", "Spannungs<67>berwachung der internen 1,5V von CY320_MC2" },
{ "STAT_SPANNUNG_PWG1_WERT", "V", "high", "unsigned int", "-", "-", "0.0010", "1.0", "0.0", "R<>ckmessung der Spannungsversorgung des PWG1" },
{ "STAT_SPANNUNG_PWG2_WERT", "V", "high", "unsigned int", "-", "-", "0.0010", "1.0", "0.0", "R<>ckmessung der Spannungsversorgung des PWG2" },
{ "STAT_SPANNUNG_32V_WERT", "V", "high", "unsigned int", "-", "-", "0.0010", "1.0", "0.0", "R<>ckmessung der internen 32 V" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDEBF[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_SYSSTATE_DPR", "0/1", "high", "unsigned char", "-", "-", "-", "-", "-", "Dualported RAM aktiv 0 = nicht aktiv 1 = aktiv" },
{ "STAT_SYSSTATE_MC0_NR", "0-n", "high", "unsigned char", "-", "TAB_AE_SYSSTATE_MCS", "-", "-", "-", "Systemzustand des MC0" },
{ "STAT_SYSSTATE_MC2_NR", "0-n", "high", "unsigned char", "-", "TAB_AE_SYSSTATE_MCS", "-", "-", "-", "Systemzustand des MC2" },
{ "STAT_SYSSTATE_KLX", "Bit", "high", "bitfield", "-", "BF_SYSSTATE_KLEMMEN", "-", "-", "-", "Klemmenzustand" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xDEDE[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_LADEVERFAHREN_NR", "0-n", "high", "unsigned char", "-", "TAB_LADEVERFAHREN", "-", "-", "-", "Art des Ladetyps" },
{ "STAT_LADESTATUS_NR", "0-n", "high", "unsigned char", "-", "TAB_LADESTATUS", "-", "-", "-", "Art des Ladestatus" },
{ "STAT_BEGINN_FENSTER_STD_WERT", "h", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Nur bei AC-Laden: Beginn des g<>nstigen Ladefensters (Stunden)" },
{ "STAT_BEGINN_FENSTER_MIN_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Nur bei AC-Laden: Beginn des g<>nstigen Ladefensters (Minuten)" },
{ "STAT_ENDE_FENSTER_STD_WERT", "h", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Nur bei AC-Laden: Ende des g<>nstigen Ladefensters (Stunden)" },
{ "STAT_ENDE_FENSTER_MIN_WERT", "min", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Nur bei AC-Laden: Ende des g<>nstigen Ladefensters (Minuten)" },
{ "STAT_LADEFENSTER1_AUSWAHL_NR", "0-n", "high", "unsigned char", "-", "TAB_LADEFENSTER_1", "-", "-", "-", "Nur bei AC-Laden, Zwei Zeit Wecker: Auswahl des g<>nstigen Ladefensters" },
{ "STAT_LADEFENSTER2_AUSWAHL_NR", "0-n", "high", "unsigned char", "-", "TAB_LADEFENSTER_1", "-", "-", "-", "Nur bei AC-Laden, Zwei Zeit Wecker: Auswahl des g<>nstigen Ladefensters" },
{ "STAT_FAKTOR_STROMBEGRENZUNG_NR", "0-n", "high", "unsigned char", "-", "TAB_FAKTOR_STROMBEGRENZUNG", "-", "-", "-", "Nur bei AC-Laden R<>ckmeldung der Strombegrenzung" },
{ "STAT_STROMBEGRENZUNG_AUSWAHL_NR", "0-n", "high", "unsigned char", "-", "TAB_STROMBEGRENZUNG_AUSWAHL", "-", "-", "-", "R<>ckmeldung der AC- Strombegrenzungauswahl Nur bei AC-Laden:" },
{ "STAT_POLY_TIM_1_WERT", "-", "high", "unsigned char", "-", "-", "0.01", "1.0", "0.0", "R<>ckmeldung der SOC Unterst<73>tzpunkte: Zeit(normiert) des ersten St<53>tzpunktes" },
{ "STAT_POLY_SOC_1_WERT", "%", "high", "unsigned char", "-", "-", "0.01", "1.0", "0.0", "R<>ckmeldung der SOC Unterst<73>tzpunkte: SOC des ersten St<53>tzpunktes" },
{ "STAT_POLY_TIM_2_WERT", "-", "high", "unsigned char", "-", "-", "0.01", "1.0", "0.0", "R<>ckmeldung der SOC Unterst<73>tzpunkte: Zeit(normiert) des zweiten St<53>tzpunktes" },
{ "STAT_POLY_SOC_2_WERT", "%", "high", "unsigned char", "-", "-", "0.01", "1.0", "0.0", "R<>ckmeldung der SOC Unterst<73>tzpunkte: SOC des zweiten St<53>tzpunktes" },
{ "STAT_POLY_TIM_3_WERT", "-", "high", "unsigned char", "-", "-", "0.01", "1.0", "0.0", "R<>ckmeldung der SOC Unterst<73>tzpunkte: Zeit(normiert) des dritten St<53>tzpunktes" },
{ "STAT_POLY_SOC_3_WERT", "%", "high", "unsigned char", "-", "-", "0.01", "1.0", "0.0", "R<>ckmeldung der SOC Unterst<73>tzpunkte: SOC des dritten St<53>tzpunktes" },
{ "STAT_POLY_TIM_4_WERT", "-", "high", "unsigned char", "-", "-", "0.01", "1.0", "0.0", "R<>ckmeldung der SOC Unterst<73>tzpunkte: Zeit(normiert) des vierten St<53>tzpunktes" },
{ "STAT_POLY_SOC_4_WERT", "%", "high", "unsigned char", "-", "-", "0.01", "1.0", "0.0", "R<>ckmeldung der SOC Unterst<73>tzpunkte: SOC des f<>nften St<53>tzpunktes" },
{ "STAT_POLY_TIM_5_WERT", "-", "high", "unsigned char", "-", "-", "0.01", "1.0", "0.0", "R<>ckmeldung der SOC Unterst<73>tzpunkte: Zeit(normiert) des f<>nften St<53>tzpunktes" },
{ "STAT_POLY_SOC_5_WERT", "%", "high", "unsigned char", "-", "-", "0.01", "1.0", "0.0", "R<>ckmeldung der SOC Unterst<73>tzpunkte: SOC des f<>nften St<53>tzpunktes" },
{ "STAT_HV_SOC_IST_WERT", "%", "high", "unsigned int", "-", "-", "0.01", "1.0", "0.0", "Aktueller SOC der HV-Batterie" },
{ "STAT_LADEN_PROGNOSE_WERT", "min", "high", "unsigned char", "-", "-", "5.0", "1.0", "0.0", "Ladezeitprognose" },
{ "STAT_LADEN_SPANNUNG_WERT", "V", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "AC-Ladespannung (nur bei AC Laden)" },
{ "STAT_LADEN_STROM_WERT", "A", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "AC-Ladestrom (nur bei AC Laden)" },
{ "STAT_ENERGIEINHALT_IST_WERT", "Ws", "high", "unsigned int", "-", "-", "3600.0", "1.0", "0.0", "Prognostizierte Energieinhalt in Abh<62>ngigkeit des Ladezustands und des Bordnetzverbrauches" },
{ "STAT_LSC_TRIGGER_INHALT_NR", "0-n", "high", "unsigned char", "-", "TAB_LSC_TRIGGER_INHALT", "-", "-", "-", "Status des LSC-Triggers" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0x400C[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "SERIENNUMMER", "-", "high", "string[10]", "-", "-", "1.0", "1.0", "0.0", "-", "-", "Seriennummer (10 Zeichen)" },
{ "JAHR", "HEX", "high", "unsigned char", "-", "-", "-", "-", "-", "-", "-", "JAHR in HEX-Format Bsp.: 15.12.2011 JAHR=0x11" },
{ "MONAT", "HEX", "high", "unsigned char", "-", "-", "-", "-", "-", "-", "-", "MONAT in HEX-Format Bsp.: 15.12.2011 MONAT=0x12" },
{ "TAG", "HEX", "high", "unsigned char", "-", "-", "-", "-", "-", "-", "-", "TAG in HEX-Format Bsp.: 15.12.2011 TAG=0x15" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0x400D[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "PROZESSOR", "0-n", "high", "unsigned char", "-", "TAB_PROZESSOR", "1.0", "1.0", "0.0", "-", "-", "Prozessor auf dem die HWCALs geschrieben werden sollen" },
{ "SENSOR_BLOCK", "0-n", "high", "unsigned char", "-", "TAB_SENSOR_BLOCK_SETHWCAL", "-", "-", "-", "-", "-", "Sensor Block: 0 = nicht definiert 1 = CPU-Sensoren 2 = PCP-Sensoren 3 = PIC-SensorenA 4 = PIC-SensorenB" },
{ "SENSOR_NR", "HEX", "-", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "-", "-", "Nummer des Sensors im ausgew<65>hlten Sensor Block: 0 = nicht definiert 1-63 = Nummer des Sensors 64 - 255 = nicht definiert" },
{ "GAIN", "HEX", "high", "unsigned long", "-", "-", "-", "-", "-", "-", "-", "Gain-Korrektur des Sensors im HEX-Format (4Byte)" },
{ "OFFSET", "HEX", "high", "unsigned long", "-", "-", "-", "-", "-", "-", "-", "Offset-Korrektur des Sensors im HEX-Format (4Byte)" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0x400E[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "PROZESSOR", "0-n", "high", "unsigned char", "-", "TAB_PROZESSOR", "1.0", "1.0", "0.0", "-", "-", "Prozessor" },
{ "SENSOR_BLOCK", "0-n", "high", "unsigned char", "-", "TAB_SENSOR_BLOCK", "-", "-", "-", "-", "-", "Sensor-Block, der geschrieben werden soll 0 = Seriennummer 1 = CPU-Sensoren 2 = PCP-Sensoren 3 = PIC-SensorenA 4 = PIC-SensorenB" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0x400F[12][]={
{ "ARG", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "AKTION", "0/1", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "-", "-", "Hardwarekalibrationsmode setzen (0/1): 0 = keine Aktion 1 = Hardwarekalibrationsmode" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xF010[14][]={
{ "ARG", "STR", "STPR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "PROZESSOR", "+", "-", "0-n", "high", "unsigned char", "-", "TAB_PROZESSOR", "1.0", "1.0", "0.0", "-", "-", "Prozessor auf dem die HWCALs geschrieben werden sollen" },
{ "SENSOR_BLOCK", "+", "-", "0-n", "high", "unsigned char", "-", "TAB_SENSOR_BLOCK_SETHWCAL", "-", "-", "-", "-", "-", "Sensor Block: 0 = Seriennummer 1 = CPU-Sensoren 2 = PCP-Sensoren 3 = PIC-SensorenA 4 = PIC-SensorenB" },
{ "SENSOR_NR", "+", "-", "HEX", "-", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "-", "-", "Nummer des Sensors im ausgew<65>hlten Sensor Block: 0 = nicht definiert 1-63 = Nummer des Sensors 64 - 255 = nicht definiert" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table ARG_0xF011[14][]={
{ "ARG", "STR", "STPR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "MIN", "MAX", "INFO" },
{ "RESET_NR", "+", "-", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "1.0", "64.0", "Nummer des Resets der im Flash abgespeichert wurde" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xF010[13][]={
{ "RESULTNAME", "STR", "STPR", "RRR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_GAIN_WERT", "+", "-", "-", "HEX", "high", "unsigned long", "-", "-", "-", "-", "-", "Gain-Korrektur des Sensors im HEX-Format (4Byte)" },
{ "STAT_OFFSET_WERT", "+", "-", "-", "HEX", "high", "unsigned long", "-", "-", "-", "-", "-", "Offset-Korrektur des Sensors im HEX-Format (4Byte)" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xF011[13][]={
{ "RESULTNAME", "STR", "STPR", "RRR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_NUMENTRY_WERT", "+", "-", "-", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Nummer des angeforderten Reset Slots" },
{ "STAT_TYPE_WERT", "+", "-", "-", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Single Reset=1; Permanent Reset=2" },
{ "STAT_CAUSE_WERT", "+", "-", "-", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Resetgrund: POWERUP_RST = 0, EXT_WATCHDOG_RST=1, INT_WATCHDOG_RST=2, SOFTWARE_RST=3, EXCEPTION_RST=4, UNKNOWN_RST=5" },
{ "STAT_EXCADDR_WERT", "+", "-", "-", "HEX", "high", "unsigned long", "-", "-", "-", "-", "-", "Erweiterte Adresse" },
{ "STAT_EXCCLASS_WERT", "+", "-", "-", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Erweiterte Klasse" },
{ "STAT_EXCTIN_WERT", "+", "-", "-", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "excTin" },
{ "STAT_WD_ERRCTR_WERT", "+", "-", "-", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Watchdog-Error-Counter" },
{ "STAT_OWN_VSMSTATE_WERT", "+", "-", "-", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Eigener System State" },
{ "STAT_PARTNER_VSMSTATE_WERT", "+", "-", "-", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Partner System State" },
{ "STAT_OWN_SYNCSTATE_WERT", "+", "-", "-", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Eigener Sync State" },
{ "STAT_PARTNER_SYNCSTATE_WERT", "+", "-", "-", "-", "high", "unsigned char", "-", "-", "1.0", "1.0", "0.0", "Partner Sync State" },
{ "STAT_RESETDUMP_DATA", "+", "-", "-", "DATA", "high", "data[128]", "-", "-", "1.0", "1.0", "0.0", "Hex-Dump des Resets-Slots aus dem Flash" }
};
// Das <20>ndern der Tabelle erfolgt im Formular SG Funktionen
table RES_0xF050[13][]={
{ "RESULTNAME", "STR", "STPR", "RRR", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_STATUS", "-", "-", "+", "0-n", "high", "char", "-", "TAB_AKTIV", "-", "-", "-", "0=inaktiv; 1=aktiv" }
};
// WERTE
table RDBI_PC_PCS_DOP[2][]={
{ "WERT", "TEXT" },
{ "0", "ECUMehrmalsProgrammierbar" },
{ "1", "ECUMindestensEinmalVollstaendigProgrammierbar" },
{ "2", "ECUNichtMehrProgrammierbar" }
};
// WERTE
table TAB_AE_PARKSPERRE_SENSOREN[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Offen" },
{ "0x01", "Geschlossen" },
{ "0x02", "In Bewegung" },
{ "0x03", "Ung<6E>ltig" }
};
// WERTE
table DM_TAB_ROE_ACTIVATED_DOP[2][]={
{ "WERT", "TEXT" },
{ "0", "Aktive Fehlermeldung deaktiviert" },
{ "1", "Aktive Fehlermeldung aktiviert" }
};
// WERTE
table TAB_AE_CHARGE_ENABLE[2][]={
{ "WERT", "TEXT" },
{ "0x00", "keine Aussage" },
{ "0x01", "wahr" },
{ "0x02", "falsch" },
{ "0x03", "ung<6E>ltig" }
};
// WERTE
table TAB_AE_SLE_FEHLERZUSTAENDE[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Derating" },
{ "0x01", "Ladeunterbrechung" },
{ "0x02", "Notlauf" },
{ "0x03", "Kommunikationsausfall" },
{ "0x04", "Reserviert" },
{ "0xFF", "Signal ung<6E>ltig" }
};
// WERTE
table TAB_EDME_TIMER_LADEN_NR[2][]={
{ "WERT", "TEXT" },
{ "0x00", "TimerLaden nicht aktiv" },
{ "0x01", "TimerLaden on Hold" },
{ "0x02", "TimerLaden aktiv" }
};
// WERTE
table TAB_STAT_ST_DIAG_DCDC_MODUS[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Antwort ausstehend" },
{ "0x01", "Erfolg" },
{ "0x02", "Fehler" }
};
// WERTE
table TAB_EDME_REMOTE_LADEN[2][]={
{ "WERT", "TEXT" },
{ "0x00", "RemoteLaden nicht aktiv" },
{ "0x01", "RemoteLaden on Hold" },
{ "0x02", "RemoteLaden aktiv" }
};
// WERTE
table TAB_AE_PARKSPERRE_NVRAM_LOESCHEN[2][]={
{ "WERT", "TEXT" },
{ "0x00", "kein L<>schen" },
{ "0x01", "L<>schen des NV-Ram (Parksperre)" }
};
// WERTE
table TAB_AE_PARKSPERRE_EINLERNEN_STATUS[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Parksperre nicht eingelernt" },
{ "0x01", "Parksperre eingelernt" }
};
// WERTE
table ENERGIESPARMODE_DOP[2][]={
{ "WERT", "TEXT" },
{ "0", "Normalmode" },
{ "1", "Fertigungsmode" },
{ "2", "Transportmode" },
{ "3", "Flashmode" }
};
// WERTE
table TAB_AE_SLE_BETRIEBSMODE[2][]={
{ "WERT", "TEXT" },
{ "0x01", "Standby" },
{ "0x02", "HV-DC Laden" },
{ "0x03", "Reserviert" },
{ "0x0F", "Signal ung<6E>ltig" }
};
// WERTE
table TAB_LSC_TRIGGER_INHALT[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Kein Trigger f<>r TS-Dienst Last State Call " },
{ "0x01", "Laden ist aufgestartet (Ladeparameter liegen vor)" },
{ "0x02", "Toleranz f<>r Abweicheung zwischen dem prognostizerten und dem Ist-Ladezustand des HV-Speichers <20>berschritten" },
{ "0x03", "Tempor<6F>re Aufhebung des Teilnetzbetriebs" },
{ "0x04", "Aufladung des Hochvoltspeichers abgeschlossen (Ladeziel erreicht oder Kunde hat beendet)" },
{ "0x05", "Laden abgebrochen" },
{ "0x06", "Laden f<>r Ladepause unterbrochen" },
{ "0x07", "Zyklisches Nachladen wegen Energiemangel nicht m<>glich" },
{ "0x08", "Zyklisches Nachladen nicht m<>glich" },
{ "0x0D", "Signal nicht verf<72>gbar m<>glich" },
{ "0x0E", "Fehler" },
{ "0x0F", "Signal nicht verf<72>gbar" }
};
// ARG
table TAB_AE_DREHZAHL_KLASSE[2][]={
{ "WERT", "TEXT" },
{ "0x00", "0-2000 U/min" },
{ "0x01", "2000-4000 U/min" },
{ "0x02", "4000-6000 U/min" },
{ "0x03", "6000-8000 U/min" },
{ "0x04", "8000-10000 U/min" },
{ "0x05", "10000-12000 U/min" },
{ "0x06", "12000-14000 U/min" }
};
// WERTE
table TAB_ST_B_DIAG_DCDC[2][]={
{ "WERT", "TEXT" },
{ "0x02", "I_diag_dcdc_lv_out verwenden" },
{ "0x04", "I_diag_dcdc_hv_out verwenden" },
{ "0x08", "U_diag_dcdc_lv_out verwenden" },
{ "0x10", "U_diag_dcdc_hv_out verwenden" }
};
// WERTE
table TAB_STAT_ST_DIAG_DCDC_GRENZEN[2][]={
{ "WERT", "TEXT" },
{ "0x01", "erfolgreich" },
{ "0x02", "nicht erfolgreich: mindestens eine geforderte Grenze verletzt eine Systemgrenze, stattdessen wird diese Systemgrenze verwendet." }
};
// WERTE
table TAB_STAT_AKS_ANFORDERUNG[2][]={
{ "WERT", "TEXT" },
{ "0x00", "kein AKS" },
{ "0x01", "AKS" },
{ "0x02", "Fehler" }
};
// WERTE
table TAB_LADEVERFAHREN[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Kein Ladeverfahren" },
{ "0x01", "AC-Laden mit Steckertyp 1 (Yazaki)" },
{ "0x02", "AC-Laden mit Steckertyp 2 (Mennekes)" },
{ "0x03", "DC-Laden mit CHAdeMo-Protokoll" },
{ "0x04", "DC-Laden mit SAE-Protokoll" },
{ "0x05", "AC-Laden China" },
{ "0xFD", "Signal nicht verf<72>gbar" },
{ "0xFE", "Fehler" },
{ "0xFF", "Signal ung<6E>ltig" }
};
// WERTE
table TAB_AE_ELUP_ROHSIGNALE[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Nicht definiert" },
{ "0x01", "Ausschalten" },
{ "0x02", "Einschalten" }
};
// WERTE
table TAB_AE_PARKSPERRE_POSTION[2][]={
{ "WERT", "TEXT" },
{ "0x00", "offen" },
{ "0x01", "geschlossen" },
{ "0x02", "nicht definiert" }
};
// WERTE
table SVK_VERSION_DOP[2][]={
{ "WERT", "TEXT" },
{ "0", "reserved" },
{ "1", "SVKVersion_01" }
};
// BITFIELD
table BF_SYSSTATE_KLEMMEN[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_SYSSTATE_KL153_0", "0/1", "high", "unsigned char", "0x01", "-", "-", "-", "-", "Klemmenzustand (bitcodiert): Bit0 = Kl15_3" },
{ "STAT_SYSSTATE_KL15WUP_1", "0/1", "high", "unsigned char", "0x02", "-", "-", "-", "-", "Klemmenzustand (bitcodiert): Bit1 = Kl15WUP" },
{ "STAT_SYSSTATE_KL30B_2", "0/1", "high", "unsigned char", "0x04", "-", "-", "-", "-", "Klemmenzustand (bitcodiert): Bit2 = KL30B" },
{ "STAT_SYSSTATE_KL30C_3", "0/1", "high", "unsigned char", "0x08", "-", "-", "-", "-", "Klemmenzustand (bitcodiert): Bit3 = KL30C" }
};
// WERTE
table RDBI_ADS_DOP[2][]={
{ "WERT", "TEXT" },
{ "0", "ISOSAEReserved_00" },
{ "1", "defaultSession" },
{ "2", "programmingSession" },
{ "3", "extendedDiagnosticSession" },
{ "4", "safetySystemDiagnosticSession" },
{ "64", "vehicleManufacturerSpecific_40" },
{ "65", "codingSession" },
{ "66", "SWTSession" }
};
// WERTE
table TAB_AE_PARKSPERRE_MAGNET_STEUERN[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Kein Einschalten" },
{ "0x01", "Einschalten des Parksperren-Magneten" }
};
// WERTE
table PROG_DEP_DOP[2][]={
{ "WERT", "TEXT" },
{ "0", "reserved" },
{ "1", "correctResult" },
{ "2", "incorrectResult" },
{ "3", "incorrectResult error SWE - HWE" },
{ "4", "incorrectResult error SWE - SWE" },
{ "255", "reserved" }
};
// WERTE
table TAB_SENSOR_BLOCK[2][]={
{ "WERT", "TEXT" },
{ "0x0", "Seriennummer" },
{ "0x1", "CPU-Sensoren" },
{ "0x2", "PCP-Sensoren" },
{ "0x3", "PIC-SensorenA" },
{ "0x4", "PIC-SensorenB" },
{ "0xff", "nicht definiert" }
};
// WERTE
table TAB_EME_IST_BETRIEBSART_DCDC[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Standby" },
{ "0x01", "Buck" }
};
// WERTE
table TAB_EME_I0ANF_HVB[2][]={
{ "WERT", "TEXT" },
{ "0x00", "keine Anforderung" },
{ "0x01", "Anforderung Nullstrom ohne EV: HV-Batteriefehler der Kategorie 5 oder geringe Ladeleistung" },
{ "0x02", "Anforderung Nullstrom mit EV: Entladeschutzfunktion HV-Batterie" },
{ "0x03", "Anforderung Nullstrom mit EV: HV-Power-Down" },
{ "0x04", "Anforderung Nullstrom mit EV: Batterieloser Betrieb" }
};
// WERTE
table TAB_STROMBEGRENZUNG_AUSWAHL[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Nicht ausgew<65>hlt" },
{ "0x01", "Ausgew<65>hlt" },
{ "0x03", "Ung<6E>ltig" }
};
// WERTE
table TAB_AKTIV[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Inaktiv" },
{ "0x01", "Aktiv" },
{ "0xFF", "unbekannt" }
};
// WERTE
table TAB_AE_FAHRSTUFE[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Initialisierung" },
{ "0x01", "ung<6E>ltig" },
{ "0x02", "ung<6E>ltig" },
{ "0x03", "ung<6E>ltig" },
{ "0x04", "ung<6E>ltig" },
{ "0x05", "D" },
{ "0x06", "N" },
{ "0x07", "R" },
{ "0x08", "P" },
{ "0x0F", "ung<6E>ltig" }
};
// WERTE
table TAB_AE_PARKSPERRE_ZUSTAND[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Einlernvorgang abgeschlossen und OK" },
{ "0x01", "Einlernvorgang abgeschlossen und NOK" },
{ "0x02", "Einlernvorgang aktiv" }
};
// BITFIELD
table BF_AE_ROTORLAGESENSOR_ERROR[10][]={
{ "RESULTNAME", "EINHEIT", "L/H", "DATENTYP", "MASKE", "NAME", "MUL", "DIV", "ADD", "INFO" },
{ "STAT_ROTORLAGESENSOR_STATUS_ERROR_0", "0/1", "high", "unsigned int", "0x0001", "-", "-", "-", "-", "Status Code: Bit 0: Abgleich erfolgreich beendet 0=nicht aktiv 1=aktiv" },
{ "STAT_ROTORLAGESENSOR_STATUS_ERROR_1", "0/1", "high", "unsigned int", "0x0002", "-", "-", "-", "-", "Status Code: Bit 1: Abgleich ung<6E>ltig beendet 0=nicht aktiv 1=aktiv" },
{ "STAT_ROTORLAGESENSOR_STATUS_ERROR_2", "0/1", "high", "unsigned int", "0x0004", "-", "-", "-", "-", "Status Code: Bit 2: Beschleunigungsphase aktiv 0=nicht aktiv 1=aktiv" },
{ "STAT_ROTORLAGESENSOR_STATUS_ERROR_3", "0/1", "high", "unsigned int", "0x0008", "-", "-", "-", "-", "Status Code: Bit 3: Abgleichsphase aktiv 0=nicht aktiv 1=aktiv" },
{ "STAT_ROTORLAGESENSOR_STATUS_ERROR_4", "0/1", "high", "unsigned int", "0x0010", "-", "-", "-", "-", "Error Code: Bit 4: Beschleunigungszeit zu hoch 0=nicht aktiv 1=aktiv" },
{ "STAT_ROTORLAGESENSOR_STATUS_ERROR_5", "0/1", "high", "unsigned int", "0x0020", "-", "-", "-", "-", "Error Code: Bit 5: Auslaufzeit zu gering 0=nicht aktiv 1=aktiv" },
{ "STAT_ROTORLAGESENSOR_STATUS_ERROR_6", "0/1", "high", "unsigned int", "0x0040", "-", "-", "-", "-", "Error Code: Bit 6: Ermittelter Offsetwert ung<6E>ltig 0=nicht aktiv 1=aktiv" },
{ "STAT_ROTORLAGESENSOR_STATUS_ERROR_7", "0/1", "high", "unsigned int", "0x0080", "-", "-", "-", "-", "Error Code: Bit 7: Nullstromabweichung in Abgleichphase 0=nicht aktiv 1=aktiv" }
};
// WERTE
table TAB_AE_ELEKTRISCHE_BETRIEBSART[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Standby (AKS)" },
{ "0x01", "Drehmomentenregelung" },
{ "0x0C", "sicherer Zustand / Fehler (AKS)" },
{ "0x0D", "Initialisierung" },
{ "0x0E", "Zwischenkreisvorladung" }
};
// WERTE
table TAB_AE_PARKSPERREN_SW[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Keine Fehler" },
{ "0x01", "Fehler steht an!" }
};
// WERTE
table TAB_AE_PARKSPERRE[2][]={
{ "WERT", "TEXT" },
{ "0x00", "keine Aktion" },
{ "0x01", "Einlegen der Parksperre" },
{ "0x02", "Auslegen der Parksperre" }
};
// WERTE
table TAB_LADEFENSTER_1[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Nicht ausgew<65>hlt" },
{ "0x01", "Ausgew<65>hlt" },
{ "0x03", "Nicht g<>ltig" }
};
// WERTE
table TAB_STAT_HVIL_GESAMT_NR[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Interlock nicht unterbrochen" },
{ "0x01", "Interlock unterbrochen" },
{ "0xFF", "nicht definiert" }
};
// ARG
table TAB_AE_DCDC_HISTOGRAMM[2][]={
{ "WERT", "TEXT" },
{ "0x00", "PHistoF" },
{ "0x01", "PHistoL" },
{ "0x02", "T1HistoF" },
{ "0x03", "T1HistoL" },
{ "0x04", "T2HistoF" },
{ "0x05", "T2HistoL" },
{ "0x06", "T3HistoF" },
{ "0x07", "T3HistoL" },
{ "0x08", "T4HistoF" },
{ "0x09", "T4HistoL" },
{ "0x0A", "rUtil" },
{ "0x0B", "rUtilF" }
};
// WERTE
table TAB_ST_DIAG_DCDC_ANF[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Kontrolle an EME-SW" },
{ "0x01", "Anforderung Buck-Modus" },
{ "0x03", "Anforderung Standby-Modus" }
};
// WERTE
table TAB_AE_EWP_STATUS[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Inaktiv (Grundzustand nach Initialisierung oder EWP ausgeschaltet)" },
{ "0x01", "Aktiv - OK" },
{ "0x02", "Aktiv - Trockenlauf" },
{ "0x03", "Aktiv - blockiert" },
{ "0x04", "Aktiv - <20>bertemperatur" },
{ "0x05", "Aktiv - minimale Drehzahl" },
{ "0x06", "Elektrischer Fehler oder Kommunikationsfehler am Leistungs - ASIC" },
{ "0x07", "Elektrischer Fehler Kurzschluss auf Masse" }
};
// WERTE
table TAB_EME_HVSTART_KOMM[2][]={
{ "WERT", "TEXT" },
{ "0x00", "HV aus" },
{ "0x01", "HV ein Anforderung" },
{ "0x02", "Freigabe HV" },
{ "0x03", "HV-Batterie Nullstromanforderung" },
{ "0x04", "HV Nachlauf 1" },
{ "0x05", "HV Nachlauf 2" },
{ "0x06", "Shutdown: Anforderung Sch<63>tze <20>ffnen" },
{ "0x07", "Shutdown: Anforderung HV-Zwischenkreisentladung" },
{ "0x09", "Anforderung Batterieloser Betrieb" },
{ "0x0A", "HV Batterieloser Betrieb: Anforderung Sch<63>tze <20>ffnen" },
{ "0x0B", "HV Batterieloser Betrieb aktiv" },
{ "0x0C", "fehlerbedingter Shutdown: R<>cknahme Freigabe HV" },
{ "0x0D", "fehlerbedingter Shutdown: Anforderung Sch<63>tze <20>ffnen" },
{ "0x0E", "fehlerbedingter Shutdown: Anforderung HV-Zwischenkreisentladung" },
{ "0x0F", "HV St<53>rung" },
{ "0x10", "Initialisierung / ung<6E>ltig" }
};
// WERTE
table FEHLERKLASSE_DOP[2][]={
{ "WERT", "TEXT" },
{ "0", "Keine Fehlerklasse verfuegbar" },
{ "1", "Ueberpruefung beim naechsten Werkstattbesuch" },
{ "2", "Ueberpruefung beim naechsten Halt" },
{ "4", "Ueberpruefung sofort erforderlich" }
};
// WERTE
table TAB_PROZESSOR[2][]={
{ "WERT", "TEXT" },
{ "0x0", "undefiniert" },
{ "0x1", "mc0" },
{ "0x2", "mc2" }
};
// WERTE
table TAB_EME_KOMM_BETRIEBSART_DCDC[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Anforderung Standby" },
{ "0x01", "Anforderung Buck" }
};
// WERTE
table TAB_LADESTATUS[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Kein Laden" },
{ "0x01", "Initialisierung" },
{ "0x02", "Laden aktiv" },
{ "0x03", "Ladepulse" },
{ "0x04", "Laden beendet" },
{ "0x05", "Ladefehler" },
{ "0x0F", "Signal ung<6E>ltig" }
};
// WERTE
table TAB_AE_SYSSTATE_MCS[2][]={
{ "WERT", "TEXT" },
{ "0x00", "eINITIALIZATION" },
{ "0x01", "ePREDRIVE" },
{ "0x02", "eREADY" },
{ "0x03", "eWAITSLEEPACKNOWLEDGE" },
{ "0x04", "eFUNCTIONPOSTDRIVE" }
};
// WERTE
table TAB_AE_ROTORLAGESENSOR_ANLEREN_AKTION[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Auto RLS-Anlernen" },
{ "0x01", "Hochdrehen/Freilauf" }
};
// WERTE
table TAB_SENSOR_BLOCK_SETHWCAL[2][]={
{ "WERT", "TEXT" },
{ "0x0", "nicht definiert" },
{ "0x1", "CPU-Sensoren" },
{ "0x2", "PCP-Sensoren" },
{ "0x3", "PIC-SensorenA" },
{ "0x4", "PIC-SensorenB" },
{ "0xff", "nicht definiert" }
};
// WERTE
table TAB_AE_ELUP_STEUERN[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Keine Aktion!" },
{ "0x01", "ELUP ansteuern" }
};
// WERTE
table TAB_EDME_STATUS_LADEN[2][]={
{ "WERT", "TEXT" },
{ "0x00", "kein Laden" },
{ "0x01", "Ladestecker gesteckt - kein Laden" },
{ "0x02", "Laden aktiv" },
{ "0x03", "Laden beendet" },
{ "0x04", "Ladest<73>rung" },
{ "0x05", "Ladefehler" }
};
// WERTE
table TAB_AE_PARKSPERRE_EINLERNEN_STEUERN[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Kein Anlernen" },
{ "0x01", "Anlernen der Parksperre" }
};
// WERTE
table TAB_AE_ZST_AKTIV_NAKTIV[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Nicht aktiv" },
{ "0x01", "Aktiv" }
};
// WERTE
table TAB_AE_ROHSIGNAL_ZUSTAND[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Nicht aktiv" },
{ "0x01", "Aktiv" }
};
// WERTE
table TAB_FAKTOR_STROMBEGRENZUNG[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Maximales Laden mit vollem AC Ladestrom." },
{ "0x01", "Reduziertes Laden mit reduziertem AC Ladestrom." },
{ "0x02", "Minimales Laden mit minimalen AC Ladestrom." },
{ "0xFF", "Signal ung<6E>ltig" }
};
// WERTE
table TAB_AE_RESET_STROM_MAX[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Keine Aktion." },
{ "0x01", "Alle maximale Str<74>me zur<75>cksetzen." },
{ "0x02", "Strom zum eKMV zur<75>cksetzen." },
{ "0x03", "Strom zum EDH zur<75>cksetzen." },
{ "0x04", "Strom zur E-Maschine zur<75>cksetzen." },
{ "0x05", "Maximalen Strom zur SLE zur<75>cksetzen." },
{ "0x06", "Maximalen Strom zum DC/DC Wandler zur<75>cksetzen." }
};
// start of : #include "MONTAGEMODUS_TAB.b2s"
/*********************** E:\MONTAGEMODUS_TAB2.b2s ******************************
// Ersteller: qx35475
// Datum der Erstellung: 27.05.10 13:42
// SGBD-Generator Version: 5.5.0_b10
*/
// -
table TAB_AE_FUNKSTAT_MONTAGEMODUS[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Funktion noch nicht gestartet" },
{ "0x01", "Start-/Ansteuerbedingung nicht erfuellt" },
{ "0x02", "Uebergabeparameter nicht plausibel" },
{ "0x03", "Funktion wartet auf Freigabe" },
{ "0x04", "nicht verfuegbarer Wert" },
{ "0x05", "Funktion laeuft" },
{ "0x06", "Funktion beendet (ohne Ergebnis)" },
{ "0x07", "Funktion abgebrochen (kein Zyklusflag/Readiness gesetzt)" },
{ "0x08", "Funktion vollst<73>ndig durchlaufen (Zyklusflag/Readiness gesetzt) und kein Fehler erkannt" },
{ "0x09", "Funktion vollst<73>ndig durchlaufen (Zyklusflag/Readiness gesetzt) und Fehler erkannt" },
{ "0xFE", "nicht definiert" },
{ "0xFF", "ungueltiger Wert" }
};
// -
table TAB_AE_STAT_MONTAGEMODUS[2][]={
{ "WERT", "TEXT" },
{ "0x00", "Montage-Modus ist inaktiv" },
{ "0x01", "Montage-Modus ist aktiv" },
{ "0xFE", "nicht definiert" },
{ "0xFF", "ungueltiger Wert" }
};
// end of : #include "MONTAGEMODUS_TAB.b2s"
// start of : #include "STATUS_EWS_TAB.b2s"
// *******************************************************************
//
// -------------------------------------------------------------------
// Tabelle: Zuordnung 'Statusbyte <-> Statustext'
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft EWS4_Funktionsbeschreibung (SAP 10001217)
// -------------------------------------------------------------------
// History:
// 09.07.2006 Schl V0.001 Erstellung fuer UDS
// 01.07.2008 Schl V1.000 Text Z<>ndung, Einspritzung, Motorlauf entfernt
// 06.03.2011 Schl V1.001 Tabelle StatEwsVerTxt erg<72>nzt
// *******************************************************************
//
// *******************************************************************
#define INCLUDE_UDS_TAB_DMEEWSTXT_B2S_NOT_FOUND
table StatClientAuthTxt[2][]={
{ "SB", "TEXT" },
{ "0x00", "Freigabe (noch) nicht erteilt (noch nicht versucht oder Kommunikation gest<73>rt)" },
{ "0x01", "Freigabe erteilt (Challenge-Response erfolgreich)" },
{ "0x02", "Freigabe abgelehnt (Challenge-Response fehlgeschlagen, falsche Response, Kommunikation i.O.)" },
{ "0x03", "nicht definiert" }
};
table StatFreeSkTxt[2][]={
{ "SB", "TEXT" },
{ "0xFE", "Ablage unbegrenzt" },
{ "0xFF", "ung<6E>ltig" },
{ "0xXY", "freie Ablagen" }
};
table StatEwsVerTxt[2][]={
{ "SB", "TEXT" },
{ "0x01", "Direktschreiben des SecretKey" },
{ "0x02", "Direktschreiben des SecretKey und DH-Abgleich" },
{ "0x03", "DH-Abgleich" },
{ "0x11", "Direktschreiben des SecretKey und EWS5" },
{ "0x12", "Direktschreiben des SecretKey und EWS5 und DH-Abgleich" },
{ "0xXY", "unbekannt" }
};
// end of : #include "STATUS_EWS_TAB.b2s"
// *******************************************************************
// Includes f<>r Jobs
// *******************************************************************
// Standard Diagnose-Jobs
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_PACKAGE.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Die Include-Paket-Nummer ist im INFO-Job mit Result PACKAGE lesbar.
// -------------------------------------------------------------------
// History:
// 14.03.2005 gh V0.01 Erstellung
// Datei UDS_INIT.B2S
// Job INITIALISIERUNG
// Datei UDS_INFO.B2S
// Job INFO
// Datei UDS_22_IDENT.B2S
// Job IDENT
// Datei UDS_19_02.B2S
// Job FS_LESEN
// Datei UDS_19_04_06.B2S ?
// Job FS_LESEN_DETAIL ?
// Datei UDS_14.B2S
// Job FS_LOESCHEN
// Datei UDS_22_1000.B2S
// Job PRUEFSTEMPEL_LESEN
// Datei UDS_2E_1000.B2S
// Job PRUEFSTEMPEL_SCHREIBEN
// 18.04.2005 gh V0.02 Datei UDS_22_IDENT.B2S
// Job IDENT_VORAB => IDENT
// 28.07.2005 gh V0.03 alle Dateien
// Namens<6E>nderung auf mehr als 8 Zeichen
// Datei UDS_19_04_06_FS_LESEN_DETAIL.B2S
// neu dazu
// 18.11.2005 gr V0.04 alle Dateien
// Umstellung auf send_and_receive_uds
// 28.11.2005 rd V0.05 Datei UDS_CONSTANTS.B2S
// Datei UDS_PARAMETER.B2S
// neu dazu
// 02.02.2006 gr V0.06 Datei UDS_TAB_FKLASSE.B2S
// Entfall (aufgrund Entfall SeverityByte)
// Datei UDS_TAB_DIGITAL_ARGUMENT.B2S
// Entfall (keine Aenderung zu STD_DIGI)
// Dateien UDS_85_02_FS_SPERREN.B2S, UDS_10_DIAG_MODE.B2S, UDS_3E_DIAG_AUFRECHT.B2S
// Anpassungen fuer STD_DIGI
// Dateien UDS_19_02_FS_LESEN.B2S, UDS_19_04_06_FS_LESEN_DETAIL.B2S, UDS_TAB_FART.B2S
// UDS_TAB_IART.B2S
// Anpassungen an DTCStatusMask 0x0C
// Dateien UDS_31_01_0F_0C_ENERGIESPARMODE.B2S, UDS_31_01_10_03_STEUERN_BETRIEBSMODE.B2S
// UDS_31_01_0F_06_IS_LOESCHEN.B2S, UDS_14_FS_LOESCHEN.B2S
// Fehlerkorrekturen
// Dateien UDS_19_02_FS_LESEN.B2S, UDS_19_04_06_FS_LESEN_DETAIL.B2S
// Anpassungen an DTCStatusMask 0x0C
// Datei UDS_TAB_SVK_ID.B2S
// Erweiterung Tabelle
// 02.02.2006 gh V0.06 Datei UDS_10_DIAGNOSE_MODE.B2S
// Datei UDS_11_STEUERGERAETE_RESET.B2S
// Datei UDS_22_10_00_PRUEFSTEMPEL_LESEN.B2S
// Datei UDS_22_16_00_SENSOREN_ANZAHL_LESEN.B2S
// Datei UDS_22_16_XX_SENSOREN_IDENT_LESEN.B2S
// Datei UDS_22_F1_8A_8B_HERSTELLINFO_LESEN.B2S
// Datei UDS_22_F1_8C_SERIENNUMMER_LESEN.B2S
// Datei UDS_2E_10_00_PRUEFSTEMPEL_SCHREIBEN.B2S
// Datei UDS_3E_DIAGNOSE_AUFRECHT.B2S
// Datei UDS_INITIALISIERUNG.B2S
// Datei STANDARD.UDS
// Include-Name ge<67>ndert (wie Job-Name)
// Datei UDS_TAB_DiagMode.B2S
// Datei UDS_TAB_DTCExtendedDataRecordNumber.B2S
// Datei UDS_TAB_DTCSnapshotIdentifier.B2S
// Datei UDS_TAB_FArtTexte.B2S
// Datei UDS_TAB_IArtTexte.B2S
// Datei UDS_TAB_Lieferanten.B2S
// Datei UDS_TAB_Prozessklassen.B2S
// Datei TABELLEN.UDS
// Datei UDS_10_DIAGNOSE_MODE.B2S
// Datei UDS_19_02_FS_LESEN.B2S
// Datei UDS_19_04_06_FS_LESEN_DETAIL.B2S
// Datei UDS_22_20_00_IS_LESEN.B2S
// Datei UDS_22_F1_01_SVK_LESEN.B2S
// Datei UDS_22_F1_8A_8B_HERSTELLINFO_LESEN.B2S
// Include-Name ge<67>ndert (wie Tabellen-Name)
// 17.02.2006 gh V0.07 Datei UDS_19_04_06_FS_LESEN_DETAIL.B2S
// Datei UDS_22_20_00_IS_LESEN_DETAIL.B2S
// Datei UDS_FS_DetailStruktur.B2S (Sub-Include)
// Datei UDS_FS_Ort_Art.B2S (Sub-Include)
// Datei UDS_FS_Extended_Data.B2S (Sub-Include)
// Datei UDS_FS_Snapshot.B2S (Sub-Include)
// IS_LESEN_DETAIL: neu dazu
// FS/IS_LESEN_DETAIL: Sub-Includes abgespalten
// 20.02.2006 gh V0.08 Datei UDS_19_04_06_FS_LESEN_DETAIL.B2S
// Datei UDS_22_20_00_IS_LESEN_DETAIL.B2S
// Datei UDS_FS_Extended_Data.B2S (Sub-Include)
// Datei UDS_FS_Snapshot.B2S (Sub-Include)
// Anzahl der Ergebniss<73>tze wie bei KWP2000
// F_UW_ZEIT_DATUM => F_UW_DATUM_ZEIT
// 22.02.2006 gh V0.09 Datei UDS_TAB_DiagMode.B2S
// Korrektur: 0x03 = ECUExtendedDiagnosticSession
// 23.02.2006 gh V0.10 Datei UDS_19_04_06_FS_LESEN_DETAIL.B2S
// Datei UDS_22_20_00_IS_LESEN_DETAIL.B2S
// Datei UDS_FS_Snapshot.B2S (Sub-Include)
// Integration Sub-Tabellen "Tab_<Index>"
// 24.02.2006 gh V0.11 Datei CODIER.UDS
// neu angelegt (wegen CPS_LESEN)
// Datei STANDARD.UDS
// Jobs DIAGNOSE_AUFRECHT und STATUS_BLOCK_LESEN entfernt
// 24.03.2006 gh V0.12 Datei UDS_22_F1_8C_SERIENNUMMER_LESEN.B2S
// Interpretation ge<67>ndert von ASCII nach HEX
// Datei UDS_19_04_06_FS_LESEN_DETAIL.B2S
// Datei UDS_22_20_00_IS_LESEN_DETAIL.B2S
// Datei UDS_FS_Ort_Art.B2S
// Zuweisung Result F_HEX_CODE erweitert
// Datei UDS_FS_Snapshot.B2S
// Zuweisung Result F_UW_DATUM_ZEIT pr<70>zisiert
// Schaltjahrberechnung korrigiert
// 27.03.2006 gh V0.13 Datei UDS_FS_Snapshot.B2S
// diskrete UW: F_UWi_WERT jetzt real
// Format bei F_UW_DATUM_ZEIT optimiert
// Datei UDS_19_04_06_FS_LESEN_DETAIL.B2S
// Datei UDS_22_20_00_IS_LESEN_DETAIL.B2S
// Abbruch, wenn zu wenig Daten in SG-Antwort
// 28.03.2006 gh Datei UDS_19_04_06_FS_LESEN_DETAIL.B2S
// Datei UDS_22_20_00_IS_LESEN_DETAIL.B2S
// Abbruch, wenn Anzahl der Daten in SG-Antwort falsch
// 29.03.2006 gh Datei UDS_FS_Snapshot.B2S
// Trace-Meldungen bzgl. return_with_message optimiert
// 30.03.2006 gh Datei UDS_22_F1_01_SVK_LESEN.B2S
// PROZESSKLASSE_WERT und VERSION: Berechnung korrigiert
// 31.05.2006 rd V0.14 Datei UDS_22_STATUS_LESEN.B2S
// <20>berarbeitet
// Datei UDS_2E_STEUERN.B2S
// <20>berarbeitet
// Datei UDS_2F_STEUERN_IO.B2S
// neu
// Datei UDS_31_STEUERN_ROUTINE.B2S
// neu
// UDS_TAB_JOBRESULT.B2S
// <20>berarbeitet
// 12.06.2006 rd V0.15 Datei UDS_22_STATUS_LESEN.B2S
// Datentyp integer und BITFIELD dazu
// Datei UDS_2E_STEUERN.B2S
// Datentyp integer dazu
// Datei UDS_2F_STEUERN_IO.B2S
// Datentyp integer dazu
// Datei UDS_31_STEUERN_ROUTINE.B2S
// Datentyp integer dazu
// 21.06.2006 rd V0.16 Datei UDS_2C_STATUS_BLOCK_LESEN.B2S
// neu
// Datei UDS_22_STATUS_LESEN.B2S
// Fehlermeldung bei string <20>berarbeitet
// Service<63>berpr<70>fung dazu aber noch nicht aktiviert
// Datei UDS_2F_STEUERN_IO.B2S
// Fehlermeldung bei string <20>berarbeitet
// Service<63>berpr<70>fung dazu aber noch nicht aktiviert
// Datei UDS_31_STEUERN_ROUTINE.B2S
// Fehlermeldung bei string <20>berarbeitet
// Service<63>berpr<70>fung dazu aber noch nicht aktiviert
// Unterschiedliche Result- und Argumentauswertung
// f<>r STR, STPR, RRR
// Datei UDS_2E_STEUERN.B2S
// Service<63>berpr<70>fung dazu aber noch nicht aktiviert
// UDS_TAB_JOBRESULT.B2S
// Erweiterung f<>r Standard-Job STATUS_BLOCK_LESEN
// 27.06.2006 rd V0.17 Datei UDS_TAB_Lieferanten.B2S
// Lieferantentext 0x77 bis 0x80 neu hinzu
// 28.06.2006 gh V0.18 Datei STANDARD.UDS
// Includes STEUERN_IO und STEUERN_ROUTINE entfernt
// Datei TABELLEN.UDS
// UDS_TAB_Fehlerklasse hinzu
// Datei UDS_19_02_FS_LESEN.B2S
// Angleichung der Auswertung an Job IS_LESEN
// Datei UDS_22_20_00_IS_LESEN.B2S
// Angleichung der Auswertung an Job FS_LESEN
// Datei UDS_19_04_06_FS_LESEN_DETAIL.B2S
// Integration Severity-Byte
// Result "F_UW_DATUM_ZEIT" entfernt
// Datei UDS_22_20_00_IS_LESEN_DETAIL.B2S
// Integration Severity-Byte
// Result "F_UW_DATUM_ZEIT" entfernt
// Datei UDS_FS_DetailStruktur.B2S
// Integration Flag "severity_exist"
// Datei UDS_FS_Snapshot.B2S
// Zuweisung Result "F_UW_DATUM_ZEIT" auskommentiert
// Datei UDS_TAB_Fehlerklasse.B2S
// neu
// Datei UDS_22_F1_8C_SERIENNUMMER_LESEN.B2S
// Anpassung an LH SAP 10000970
// Datei UDS_TAB_DiagMode.B2S
// Integration weiterer Diagnose-Modi
// 29.06.2006 gh V0.19 Datei UDS_FS_DetailStruktur.B2S
// Fehlerbehandlung Flags
// 08.08.2006 rd V0.20 Datei UDS_CONSTANTS.UDS
// REPAET_COUNTER von 2 auf 1 reduziert
// wegen Einsatz parallele Diagnose am D-CAN
// Datei UDS_PARAMETER.B2S
// BMW-KWP2000-CAN Timeout und TP-Layer angepasst
// 14.09.2006 rd V0.21 Datei UDS_TAB_LIEFERANTEN.B2S
// Lieferanten 0x81 und 0x84 dazu
// 18.09.2006 gh V0.22 Datei STANDARD.UDS
// Job SERIENNUMMER_LESEN dazu
// 15.11.2006 gh V0.23 Datei UDS_19_04_06_FS_LESEN_DETAIL.B2S
// Sonderfall Fehler nicht in SG gespeichert
// Anzahl UWB-S<>tze einstellbar
// komplexe UWB: Ausgabe als Text (string)
// Datei UDS_22_20_00_IS_LESEN_DETAIL.B2S
// Anpassungen wegen Erweiterung FS_LESEN_DETAIL
// Datei UDS_FS_DetailStruktur.B2S
// Anzahl UWB-S<>tze einstellbar
// Datei UDS_FS_Snapshot.B2S
// komplexe UWB: Ausgabe als Text (string)
// 04.12.2006 gh V0.24 Datei UDS_TAB_ROE_AKTIV.B2S
// neu dazu (Tabelle bzgl. Response On Event)
// Datei UDS_JOBS_ROE.B2S
// neu dazu (Sanmmelinclude: 5 Jobs bzgl. Response On Event)
// Datei UDS_86_00_02_STEUERN_ROE_STOP.B2S
// neu dazu (optionaler Jobs bzgl. Response On Event)
// Datei UDS_86_04_STATUS_ROE_REPORT.B2S
// neu dazu (optionaler Jobs bzgl. Response On Event)
// Datei UDS_86_05_02_STEUERN_ROE_START.B2S
// neu dazu (optionaler Jobs bzgl. Response On Event)
// Datei UDS_86_40_02_STEUERN_ROE_PERSISTENT_STOP.B2S
// neu dazu (optionaler Jobs bzgl. Response On Event)
// Datei UDS_86_45_02_STEUERN_ROE_PERSISTENT_START.B2S
// neu dazu (optionaler Jobs bzgl. Response On Event)
// 23.03.2007 gh V0.25 Datei UDS_22_16_XX_SENSOREN_IDENT_LESEN.B2S
// Verbauort mit SG-Adresse verkn<6B>pft
// Auswertung optionaler LIN-Daten hinzu
// Datei UDS_22_F1_86_DIAG_SESSION_LESEN.B2S
// Anforderung W 2.4, Richard Kolbeck (fuer LDM)
// Datei UDS_22_25_02_PROG_ZAEHLER_LESEN.B2S
// Anforderung W 2.4, Richard Kolbeck (fuer LDM)
// Datei UDS_22_25_03_PROG_MAX_LESEN.B2S
// Anforderung W 2.4, Richard Kolbeck (fuer LDM)
// Datei UDS_22_25_04_FLASH_TP_LESEN.B2S
// Anforderung W 2.4, Richard Kolbeck (fuer LDM)
// Datei UDS_31_01_FF_01_PROG_ABHAENGIGKEITEN_LESEN.B2S
// Anforderung W 2.4, Richard Kolbeck (fuer LDM)
// Datei UDS_TAB_Lieferanten.B2S
// Lieferanten 0x85 bis 0x96 neu dazu
// Lieferant 0x72 Rechtschreibfehler behoben
// Datei UDS_22_37_FE_CPS_LESEN.B2S
// BEST-Befehl dataclear integriert
// Datei UDS_22_F1_8A_8B_HERSTELLINFO_LESEN.B2S
// Service $F18A jetzt optional
// Datei UDS_22_20_00_IS_LESEN_DETAIL.B2S
// Sonderfall "anzahl_snapshotRecord = 0" ohne Error "Division by Zero"
// Datei UDS_TAB_Prozessklassen.B2S
// Prozessklassen ge<67>ndert (teilweise INKOMPATIBEL !!!)
// 28.03.2007 gh V0.26 Datei UDS_31_01_FF_01_PROG_ABHAENGIGKEITEN_LESEN.B2S
// entfernt, da Job nur in ProgrammingSession m<>glich
// Datei UDS_22_F1_01_SVK_LESEN.B2S
// Result (int) PROG_TEST dazu
// Datei UDS_22_STATUS_LESEN.B2S
// Service<63>berpr<70>fung aktiv
// Resultname beginnend mit _STAT_ jetzt erlaubt
// Datei UDS_2C_STATUS_BLOCK_LESEN.B2S
// Service<63>berpr<70>fung aktiv
// Resultname beginnend mit _STAT_ jetzt erlaubt
// Datei UDS_2E_STEUERN.B2S
// Service<63>berpr<70>fung aktiv
// Datei UDS_2F_STEUERN_IO.B2S
// Service<63>berpr<70>fung aktiv
// Resultname beginnend mit _STAT_ jetzt erlaubt
// Datei UDS_31_STEUERN_ROUTINE.B2S
// Service<63>berpr<70>fung aktiv
// Resultname beginnend mit _STAT_ jetzt erlaubt
// 02.05.2007 gh V0.27 Datei UDS_22_25_04_FLASH_TP_LESEN.B2S
// Reihenfolge bei 18-Byte-Antwort korrigiert
// Datei CBS5JOBS.B2S
// Korrektur von Stefan Jurthe, EF620 (Job CBS_RESET)
// 30.10.2007 gr V0.28 Datei UDS_19_02_FS_LESEN.B2S angepasst
// 22.11.2007 rd V0.29 Datei UDS_TAB_Lieferanten.B2S
// Lieferanten 0x9A bis 0x9E neu dazu
// 20.02.2008 rd V1.00 Datei STD_ISEN.B2S
// Spurwechselradarsensor Lin 2 Format
// 25.02.2008 rd V1.01 Datei STD_ISEN.B2S
// PMA Sensoren hinzu
// 07.03.2008 rd V1.02 Datei STD_ISEN.B2S
// Startergenerator, <20>lqualit<69>tsensor hinzu
// 17.03.2008 rd V1.03 Datei STD_ISEN.B2S
// Topview, Sideview, Rearview Kameras LIN_2_FORMAT
// 01.04.2008 as V1.04 Datei UDS_TAB_IArtTexte.B2S
// Texte von UDS_TAB_FArtTexte.B2S <20>bernommen
// 14.06.2008 rd V1.05 Datei UDS_TAB_Lieferante.B2S
// Lieferanten bis 0xA4 dazu
// 01.08.2008 rd V1.06 Datei STD_ISEN.B2S
// ACSM4 Sensoren dazu
// 15.09.2008 gr V1.07 Datei UDS_22_20_00_IS_LESEN.B2S
// Korrektur bei Result F_HEX_CODE
// 21.10.2008 rd V1.08 Datei UDS_TAB_Lieferanten.B2S
// Lieferant 0xA5 dazu
// 18.11.2008 rd V1.09 Datei STD_ISEN.B2S
// Mirkrowellensensoren <20>berarbeitet
// 19.01.2009 as V1.10 Datei UDS_TAB_JobResult.B2S
// Erweiterung der JobResult-Tabelle
// 19.01.2009 as V1.11 Datei UDS_TAB_JobResult.B2S, UDS_TAB_DiagMode.B2S
// Erweiterung der JobResult-Tabelle, Modierweiterung
// 19.01.2009 gh V1.12 Datei UDS_19_15_FS_LESEN_PERMANENT.B2S hinzu
// 30.07.2009 rd V1.13 Datei UDS_TAB_Lieferanten.B2S
// Lieferanten aktualisiert
// 30.07.2009 gr V1.14 Datei UDS_TAB_LieferantenLIN.B2S
// Lieferanten aktualisiert
// 07.12.2009 rd V1.15 Datei UDS_TAB_LieferantenLIN.B2S
// Lieferanten aktualisiert
// Datei UDS_TAB_GROBNAME.B2S
// Aktualisiert
// 05.03.2010 rd V1.16 Datei UDS_TAB_GROBNAME.B2S
// Aktualisiert
// 29.04.2010 gh V1.17 Datei UDS_FS_Snapshot.B2S
// Sub-Tabellen f<>r diskrete UW: Spaltenname "UWTEXT" oder "TEXT"
// rd Datei UDS_TAB_Lieferanten.B2S
// Lieferanten aktualisiert
// 10.12.2010 gh V1.18 Datei UDS_TAB_LIEFERANTENLIN.B2S
// Lieferanten aktualisiert
// Datei UDS_2C_STATUS_BLOCK_LESEN.B2S
// Datei UDS_2E_STEUERN.B2S
// Datei UDS_2F_STEUERN_IO.B2S
// Datei UDS_31_STEUERN_ROUTINE.B2S
// Datei UDS_22_STATUS_LESEN.B2S
// neue Einheit DATA, TEXT dazu
// Integration DUMMY_ bei Einheit DATA
// Integration Entfall L<>ngenpr<70>fung
// Anforderungen VH-53,Waegner und EA-410, Lorch
// Datei UDS_MOSTJOBS.B2S
// Datei UDS_MOST_TAB.B2S
// Update, neue Verantwortung: Florian Lange, EI-42
// 26.05.2011 gh V1.19 Datei UDS_TAB_Prozessklassen.B2S
// Prozessklasse 0x04 GWTB hinzu
// 30.11.2011 rd V1.20 Datei UDS_TAB_Lieferanten.B2S
// Lieferanten aktualisiert
// 15.12.2011 rd V1.21 Datei STD_ISEN.B2S
// <20>berarbeitet
// 25.01.2012 rd V1.22 Datei UDS_TAB_Lieferanten.B2S
// Lieferanten aktualisiert
// 02.02.2012 rd V1.23 Datei STD_ISEN.B2S
// <20>berarbeitet
// 24.02.2012 rd V1.24 Datei UDS_22_10_0B_I_STUFE_LESEN.B2S
// Backup jetzt CAS oder KOMBI oder FEM
// 01.03.2012 rd V1.25 Datei STD_ISEN.B2S
// <20>berarbeitet
// *******************************************************************
// UDS_PACKAGE.B2S @(#)@ V1.25 @(#)@
// *******************************************************************
#define __PACKAGE__ "1.25"
// end of : #include "UDS_PACKAGE.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\STD_INFO.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : INFO
// -------------------------------------------------------------------
// History:
// 31.01.2001 rd V0.01 Erstellung
// 25.03.2002 rd V1.00 Freigabe
// 22.04.2003 rd V1.01 Versionskennung hinzu
// *******************************************************************
// STD_INFO.B2S @(#)@ V1.01 @(#)@
// *******************************************************************
job ( name : INFO;
comment : Information SGBD;
result : ECU;
type : string;
defrslt : ;
comment : Steuerger<65>t im Klartext;
result : ORIGIN;
type : string;
defrslt : ;
comment : Steuerger<65>te-Verantwortlicher;
result : REVISION;
type : string;
defrslt : ;
comment : Versions-Nummer;
result : AUTHOR;
type : string;
defrslt : ;
comment : Namen aller Autoren;
result : COMMENT;
type : string;
defrslt : ;
comment : wichtige Hinweise;
result : PACKAGE;
type : string;
defrslt : ;
comment : Include-Paket-Nummer;
result : SPRACHE;
type : string;
defrslt : ;
comment : deutsch, english;
)
{
ECU = __ECU__;
ORIGIN = __ORIGIN__;
REVISION = __REVISION__;
AUTHOR = __AUTHOR__;
COMMENT = __ECUCOMMENT__;
PACKAGE = __PACKAGE__;
SPRACHE = "deutsch";
}
// end of : #include "STD_INFO.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_INITIALISIERUNG.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : INITIALISIERUNG
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 18.11.2005 rd V0.001 Erstellung
// 28.11.2005 rd V0.002 CAN Parameter dazu
// 02.02.2006 gh V0.003 Include-Name ge<67>ndert (wie Job-Name)
// *******************************************************************
// UDS_INITIALISIERUNG.B2S @(#)@ V0.003 @(#)@
// *******************************************************************
job ( name : INITIALISIERUNG;
comment : Initialisierung und Kommunikationsparameter;
result : DONE;
type : int;
defrslt : ;
comment : 1, wenn Okay;
)
{
open_communication(); // Kommunikation starten
stop_frequent(); // evtl. bestehende ACK killen
set_repeat_counter(REPEAT_COUNTER); // Wiederholzaehler setzen
set_communication_pars(PARAMETER_BMW_KWP2000_CAN); // Konzept einstellen
set_answer_length(AWLEN_BMW_KWP2000_CAN); // Antwortlaenge
DONE = 1; // muss immer 'DONE' heissen !
}
// end of : #include "UDS_INITIALISIERUNG.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_F1_50_IDENT.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : IDENT
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 18.11.2005 gr V0.001 Erstellung
// *******************************************************************
// UDS_22_F1_50_IDENT.B2S @(#)@ V0.001 @(#)@
// *******************************************************************
job ( name : IDENT;
comment : Identdaten;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $F150 Sub-Parameter SGBD-Index;
comment : Modus: Default;
result : ID_SG_ADR;
type : long;
comment : Steuergeraeteadresse;
result : ID_SGBD_INDEX;
type : long;
comment : Index zur Erkennung der SG-Variante;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x22, 0xF1, 0x50};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if(ID_SG_ADR)
ID_SG_ADR = SA_response;
if(ID_SGBD_INDEX)
ID_SGBD_INDEX = (response[3] << 16) + (response[4] << 8) + response[5];
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_22_F1_50_IDENT.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_19_02_FS_LESEN.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : FS_LESEN
// -------------------------------------------------------------------
// Globale Tabelle : JobResult, FOrtTexte, FArtTexte
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 15.11.2005 gr V0.001 Erstellung
// 02.02.2006 gr V0.002 Anpassung an neue DTCStatusMask 0C
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Tabellen-Name)
// 22.06.2006 gh V0.003 Angleichung der Auswertung an Job IS_LESEN
// 30.10.2007 gr V0.004 Ausgabe des F_HEX_CODE korrigiert (dataclear(temp))
// *******************************************************************
// UDS_19_02_FS_LESEN.B2S @(#)@ V0.003 @(#)@
// *******************************************************************
job ( name : FS_LESEN;
comment : Fehlerspeicher lesen (alle Fehler / Ort und Art);
comment : UDS : $19 ReadDTCInformation;
comment : UDS : $02 ReadDTCByStatusMask;
comment : UDS : $0C StatusMask (Bit2, Bit3);
comment : Modus: Default;
result : F_VERSION;
type : int;
defrslt : 3;
comment : Typ des Fehlerspeichers;
comment : Fuer UDS immer 3;
result : F_HEX_CODE;
type : data;
comment : Fehlerdaten pro Fehler als Hexcode;
result : F_ORT_NR;
type : long;
comment : Index fuer Fehlerort;
result : F_ORT_TEXT;
type : string;
comment : Fehlerort als Text;
comment : table FOrtTexte ORTTEXT;
result : F_EREIGNIS_DTC;
type : int;
comment : 0: DTC kein Ereignis DTC;
comment : 1: DTC ist Ereignis DTC;
comment : table FOrtTexte EREIGNIS_DTC;
result : F_READY_NR;
type : int;
comment : Readyness Flag (Standard-Fehlerart) als Zahl;
result : F_READY_TEXT;
type : string;
comment : Readyness Flag (Standard-Fehlerart) als Text;
comment : table FArtTexte ARTTEXT;
result : F_VORHANDEN_NR;
type : int;
comment : Fehler vorhanden (Standard-Fehlerart) als Zahl;
result : F_VORHANDEN_TEXT;
type : string;
comment : Fehler vorhanden (Standard-Fehlerart) als Text;
comment : table FArtTexte ARTTEXT;
result : F_WARNUNG_NR;
type : int;
comment : Warnlampen Flag (Standard-Fehlerart) als Zahl;
result : F_WARNUNG_TEXT;
type : string;
comment : Warnlampen Flag (Standard-Fehlerart) als Text;
comment : table FArtTexte ARTTEXT;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// Variablen fuer Kommunikation
unsigned char request[] = {0x19, 0x02, 0x0C};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// Variablen fuer Job
unsigned char temp[];
unsigned char text[];
int anzahl;
int index;
int offset;
long wert;
int LIStatusDTC = 0x00;
// ---------------- Ueberpruefung ob Tabellen includiert sind --------
INCLUDE_UDS_TAB_FArtTexte_B2S_NOT_FOUND;
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
index = 0;
offset = 3;
anzahl = (datalen(response) - 3) / 4;
// Verifikation der Datenlaenge
if (datalen(response) != (3 + (anzahl*4))) { // Rundungsfehler bei Berechnung der ANZAHL
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "ERROR_ECU_INCORRECT_LEN";
return;
}
while (index < anzahl) {
LIStatusDTC = response[offset + 3] & 0x4D; // Auslesen des Status Bytes. F<>r die Auswertung sind die Bits 0,2,3,6 entscheidend
if (F_HEX_CODE) {
dataclear(temp);
datacopy(temp, response, offset, 4);
F_HEX_CODE = temp;
}
if (F_ORT_NR || F_ORT_TEXT || F_EREIGNIS_DTC || F_READY_NR || F_READY_TEXT || F_VORHANDEN_NR || F_VORHANDEN_TEXT || F_WARNUNG_NR || F_WARNUNG_TEXT) {
// Ausgabe Fehlerort
wert = (response[offset] << 16) + (response[offset + 1] << 8) + response[offset + 2];
F_ORT_NR = wert;
// Dazugehoeriger Fehlertext
tabset("FOrtTexte");
tab_suche_unsigned("ORT", wert);
tabget(text, "ORTTEXT");
F_ORT_TEXT = text;
// Ereignis-DTC ja / nein
tabget(text, "EREIGNIS_DTC");
F_EREIGNIS_DTC = atoi(text);
// Gibt an, ob Test seit dem letzten loeschen einmal komplett durchlaufen wurde; Offset 0x10 wird addiert, um Tabelle FArtTexte verwenden zu k<>nnen
wert = ((response[offset+3] >> 4) & 0x01) + 0x10;
F_READY_NR = wert;
tabset("FArtTexte");
tab_suche_unsigned("ARTNR", wert);
tabget(text, "ARTTEXT");
F_READY_TEXT = text;
// Fehler aktuell vorhanden? Bit 0 und Bit 6 muessen beide 1 beinhalten, dann ist Fehler aktuell vorhanden
F_VORHANDEN_NR = LIStatusDTC;
tab_suche_unsigned("ARTNR", LIStatusDTC);
tabget(text, "ARTTEXT");
F_VORHANDEN_TEXT = text;
// Geht eine Warnlampe an oder nicht
wert = ((response[offset+3] >> 7) & 0x01) + 0x80;
F_WARNUNG_NR = wert;
tab_suche_unsigned("ARTNR", wert);
tabget(text, "ARTTEXT");
F_WARNUNG_TEXT = text;
}
new_set_of_results(); // neuer Ergebnissatz
index++;
offset += 4;
}
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_19_02_FS_LESEN.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_19_04_06_FS_LESEN_DETAIL.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : FS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, FOrtTexte, FArtTexte, FDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// FUmweltTexte
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 28.07.2005 gh V0.001 Erstellung (nur Teilumfang !)
// 24.11.2005 gr V0.002 Erweiterung
// 14.12.2005 gr V0.003 Result F_SATZ_ZEIT_DATUM hinzu
// 20.12.2005 gr V0.004 *_SATZ_* aus den Results entfernt (Verwendbarkeit)
// 20.12.2005 gr V0.004 SAECodeTexte auf externe Tabellen-SGBD T_SCOD umgestellt
// 02.02.2006 gr V0.005 Entfall Abfrage ServerityByte (Beschluss AKD)
// 02.02.2006 gr V0.005 Include-Name ge<67>ndert (wie Tabellen-Name)
// 09.02.2006 gh V0.006 4 Sub-Includes abgespalten
// 15.02.2006 gh V0.007 gestestet mit Simulation
// 16.02.2006 gh V0.008 Zuweisung "response1 = response;" integriert
// 20.02.2006 gh V0.009 Umbenennung F_UW_ZEIT_DATUM => F_UW_DATUM_ZEIT
// 22.02.2006 gh V0.010 Integration Subtabellen Tab_<Index>
// 23.02.2006 gh V0.010 Korrektur Variablendefinition: unsigned !
// 24.03.2006 gh V0.011 Zuweisung Result F_HEX_CODE integriert
// 24.03.2006 gh V0.011 Sonderf<72>lle 0xFFFFFF(FF) bei F_UW_KM / F_UW_DATUM_ZEIT
// 24.03.2006 gh V0.011 _RESPONSE_* auch bei Abbruch
// 27.03.2006 gh V0.012 Abbruch, wenn zu wenig Daten in SG-Antwort
// 28.03.2006 gh V0.012 Abbruch, wenn Anzahl der Daten in SG-Antwort falsch
// 23.06.2006 gh V0.013 Integration Severity-Byte
// 28.06.2006 gh V0.014 Result "F_UW_DATUM_ZEIT" entfernt
// 29.06.2006 gh V0.015 Results bzgl. Severity-Byte in Satz 1
// 18.10.2006 gh V0.020 $19 $04: Sonderfall Fehler nicht in SG gespeichert
// 18.10.2006 gh V0.020 $19 $04: Anzahl UWB-S<>tze einstellbar
// 19.10.2006 gh V0.020 $19 $04: komplexe UWB: Ausgabe als Text (string)
// 14.03.2008 gr V0.021 Variable LIHlzValid hinzu
// *******************************************************************
// UDS_19_04_06_FS_LESEN_DETAIL.B2S @(#)@ V0.021 @(#)@
// *******************************************************************
job ( name : FS_LESEN_DETAIL;
comment : Fehlerspeicher lesen (einzelner Fehler / Ort und Art);
comment : UDS : $19 ReadDTCInformation;
comment : UDS : $04 reportDTCSnapshotRecordByDTCNumber;
comment : UDS : $06 reportDTCExtendedDataRecordByDTCNumber;
comment : UDS : $09 reportSeverityInformationOfDTC;
comment : Modus: Default;
argument : F_CODE;
type : long;
comment : gewaehlter Fehlercode;
result : F_VERSION;
type : int;
defrslt : 3;
comment : Typ des Fehlerspeichers;
comment : Fuer UDS immer 3;
result : F_HEX_CODE;
type : data;
comment : Fehlerdaten pro Fehler als Hexcode;
result : F_ORT_NR;
type : long;
comment : Index fuer Fehlerort;
result : F_ORT_TEXT;
type : string;
comment : Fehlerort als Text;
comment : table FOrtTexte ORTTEXT;
result : F_EREIGNIS_DTC;
type : int;
comment : 0: DTC kein Ereignis DTC;
comment : 1: DTC ist Ereignis DTC;
comment : table FOrtTexte EREIGNIS_DTC;
result : F_READY_NR;
type : int;
comment : Readyness Flag (Standard-Fehlerart) als Zahl;
result : F_READY_TEXT;
type : string;
comment : Readyness Flag (Standard-Fehlerart) als Text;
comment : table FArtTexte ARTTEXT;
result : F_VORHANDEN_NR;
type : int;
comment : Fehler vorhanden (Standard-Fehlerart) als Zahl;
result : F_VORHANDEN_TEXT;
type : string;
comment : Fehler vorhanden (Standard-Fehlerart) als Text;
comment : table FArtTexte ARTTEXT;
result : F_WARNUNG_NR;
type : int;
comment : Warnlampen Flag (Standard-Fehlerart) als Zahl;
result : F_WARNUNG_TEXT;
type : string;
comment : Warnlampen Flag (Standard-Fehlerart) als Text;
comment : table FArtTexte ARTTEXT;
result : F_HFK;
type : int;
comment : Haufigkeitszaehler als Zahl;
comment : Wertebereich 0 - 255;
comment : Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf;
result : F_HLZ;
type : int;
comment : Heilungsszaehler als Zahl;
comment : Wertebereich 0 - 255;
comment : -1: ohne Haufigkeitszaehler;
result : F_UEBERLAUF;
type : int;
comment : 0: Kein Ueberlauf des Fehlerspeichers;
comment : 1: Ueberlauf des Fehlerspeichers;
result : F_FEHLERKLASSE_NR;
type : int;
comment : 0: Keine Fehlerklasse verfuegbar;
comment : 1: Ueberpruefung bei naechstem Werkstattbesuch;
comment : 2: Ueberpruefung bei naechstem Halt;
comment : 4: Ueberpruefung sofort erforderlich !;
result : F_FEHLERKLASSE_TEXT;
type : string;
comment : Ausgabe der Fehlerklasse als Text;
comment : table Fehlerklasse TEXT;
result : F_UW_ANZ;
type : int;
comment : Anzahl der Umweltbedingungen;
comment : Je nach dieser Anzahl i (i = 1, 2, ...);
comment : existieren i mal folgende Results:;
comment : (long) F_UWi_NR Index der i. Umweltbedingung;
comment : (string) F_UWi_TEXT Text zur i. Umweltbedingung;
comment : (real) F_Uwi_WERT Wert der i. Umweltbedingung;
comment : (string) F_UWi_EINH Einheit der i. Umweltbedingung;
result : F_UW_KM;
type : long;
comment : Umweltbedingung Kilometerstand (3 Byte);
comment : Wertebereich: 0 - 16777215 km;
comment : -1, wenn Kilometerstand nicht zur Verfuegung steht;
result : F_UW_ZEIT;
type : long;
comment : Umweltbedingung Absolute Zeit (4 Byte);
comment : Genauigkeit: in Sekunden;
comment : -1, wenn Absolute Zeit nicht zur Verfuegung steht;
/*
result : F_UW_DATUM_ZEIT;
type : string;
comment : Umweltbedingung Absolute Zeit im Datumsformat DD.MM.YYYY hh:mm:ss;
comment : Beginn: 01.01.2000 00:00:00;
*/
result : F_SAE_CODE;
type : unsigned int;
comment : Wertebereich 0x000000 - 0xFFFFFF;
comment : externe Tabelle T_SCOD;
result : F_SAE_CODE_STRING;
type : string;
comment : 5 stelliger Text in der Form 'Sxxxx';
result : F_SAE_CODE_TEXT;
type : string;
comment : Text zu F_SAE_CODE;
result : _RESPONSE_SNAPSHOT;
type : data;
comment : Hex-Antwort von SG;
result : _RESPONSE_EXTENDED_DATA;
type : data;
comment : Hex-Antwort von SG;
result : _RESPONSE_SEVERITY;
type : data;
comment : Hex-Antwort von SG;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
)
{
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
unsigned int LIStatusDTC = 0x00;
unsigned char temp[];
unsigned char text[];
unsigned char text1[];
unsigned char response1[];
long wert;
unsigned long code;
unsigned int offset;
unsigned int LILaengeData;
unsigned long LLData;
unsigned long zeit_aktuell;
// Variablen f<>r die Basis-Infos des DTC
int LIExtendedRecordNumber;
int LIUWErweitertExist;
int LIHlzExist;
int LIHlzValid; // Hinzu in Version 0.021
int LISaeCodeExist;
int severity_exist;
unsigned char severity_byte;
/* // Variablen zur Zeitberechnung
unsigned int LIJahr;
unsigned int LIMonat;
unsigned int LITag;
unsigned int LIStunden;
unsigned int LIMinuten;
unsigned int LISekunden;
unsigned int LIAbbruch;
unsigned int LISchaltjahr;
*/
// Variablen fuer die Umweltsaetze
unsigned long LLAnzahlSnapshotIdentifier;
unsigned int LISnapshotNumber;
unsigned int LIIdentifier;
unsigned int LICounterUW;
unsigned int LIAnzUW;
unsigned int LICounterIdentifier;
int uw_satz_anzahl;
unsigned int uw_sub_index; // Index der Sub-UW
unsigned int uw_sub_anz; // Anzahl der Sub-UWs
unsigned int identifier_sub; // Identifier der Sub-UW
unsigned int offset_start; // Startwert bei Extended Data
unsigned int uw_laenge; // Laenge der einzelnen UW [Bytes]
unsigned char uw_gueltig; // Flag, ob UW gueltig d.h. "offset < daten_laenge"
unsigned long uw_mask; // Maske fuer digitale bzw. diskrete UW
unsigned long uw_wert_mask; // Puffer fuer F_UWn_WERT (Bitmaske: digital / diskret)
long uw_wert; // Puffer fuer F_UWn_WERT (long)
real uw_wert_real; // Puffer fuer F_UWn_WERT (real)
real uw_mul_real; // fuer Berechnung analoger UW
real uw_div_real; // fuer Berechnung analoger UW
real uw_add_real; // fuer Berechnung analoger UW
unsigned int daten_laenge; // "datalen(daten)" (kommt mehrfach vor)
unsigned int uw_typ; // ODER-Verknuefpung von UW-Typ-Flags
unsigned int uw_typ_digital = 0x0001; // Flag fuer digitale UW (Grundtyp / Zuweisung )
unsigned int uw_typ_diskret = 0x0002; // Flag fuer diskrete UW (Grundtyp / Zuweisung )
unsigned int uw_typ_analog = 0x0004; // Flag fuer analoge UW (long) (Grundtyp / Zuweisung )
unsigned int uw_typ_float = 0x0008; // Flag fuer analoge UW (real / float) (Zusatz / Veroderung)
unsigned int uw_typ_double = 0x0010; // Flag fuer analoge UW (real / double) (Zusatz / Veroderung)
unsigned int uw_typ_signed = 0x0020; // Flag fuer Vorzeichen der UW (unsigned / signed) (Zusatz / Veroderung)
unsigned int uw_typ_Motorola = 0x0040; // Flag fuer Prozessor (Intel / Motorola) (Zusatz / Veroderung)
unsigned int uw_typ_low_high = 0x0080; // Flag fuer Reihenfolge (high/low, low/high) (Zusatz / Veroderung)
unsigned int uw_typ_hex = 0x0100; // Flag fuer hexadezimale UW (1, 2, 4 Byte => string) (Grundtyp / Zuweisung )
unsigned int uw_typ_text = 0x0200; // Flag fuer UW als Text (string mit n Bytes) (Grundtyp / Zuweisung )
// Telegram fuer Severity-Byte
unsigned char request[] = {0x19,0x09,0xFF,0xFF,0xFF};
// Service ReadDTCInformation --------+ | | | |
// SubPara SeverityInformationOfDTC -------+ | | |
// DTCNumber------------------------------------+----+----+
// ---------------- Ueberpruefung ob Tabellen includiert sind --------
INCLUDE_UDS_TAB_FArtTexte_B2S_NOT_FOUND;
INCLUDE_UDS_TAB_DTCExtendedDataRecordNumber_B2S_NOT_FOUND;
INCLUDE_UDS_TAB_DTCSnapshotIdentifier_B2S_NOT_FOUND;
INCLUDE_UDS_TAB_Fehlerklasse_B2S_NOT_FOUND;
// ---------------- Argumente des Jobs auswerten ---------------------
if (exist(F_CODE)) {
code = F_CODE;
request[2] = (code >>16) & 0xFF;
request[3] = (code >> 8) & 0xFF;
request[4] = code & 0xFF;
}
else {
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
// ---------------- Auswertung XDetailStruktur -----------------------
#define DetailStruktur "FDetailStruktur"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_FS_DetailStruktur.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : FS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, FOrtTexte, FArtTexte, FDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// FUmweltTexte
// -------------------------------------------------------------------
// Jobname : IS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, IOrtTexte, IArtTexte, IDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// IUmweltTexte
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// -------------------------------------------------------------------
// Hinweise allgemein:
// (1) : JOB_STATUS = "ERROR_TABLE"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// erkannt wird, dass eine Tabelle falsch befuellt ist.
// (2) : JOB_STATUS = "ERROR_INTERPRETATION"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// ein Fall auftritt, der undefiniert ist.
// (Dies sollte normalerweise nie passieren !)
// (1),(2): Das Result "ERROR_MESSAGE" enthaelt zusaetzliche Hinweise.
//
// (3) : EDIABAS_BIP_0010 / CONSTANT DATA ACCESS ERROR
// -> Dieser EDIABAS-Fehler tritt auf, wenn im Job eine Tabellen-
// Spalte, die in der SGBD benutzt wird, nicht existiert
// (z.B. bei fehlerhaft dimensionierten Tabellen).
// Es entsteht deshalb eine EDIABAS-Fehlermeldung, da die
// Ueberpruefung der Tabellen-Spalten erst zur Laufzeit
// geschieht.
// -------------------------------------------------------------------
// History:
// 09.02.2006 gh V0.001 Erstellung
// 15.02.2006 gh V0.002 getestet mit Simulation
// 23.06.2006 gh V0.003 Integration Flag "severity_exist"
// 29.06.2006 gh V0.004 Fehlerbehandlung Flags
// 18.10.2006 gh V0.020 neues Konfigurationselement: F_UWB_SATZ
// 14.03.2007 gr V0.021 neues Konfigurationselement: F_HLZ_VIEW
// *******************************************************************
// UDS_FS_DetailStruktur.B2S @(#)@ V0.021 @(#)@
// *******************************************************************
// ---------------- Auswertung XDetailStruktur -----------------------
tabset(DetailStruktur); // Tabelle nicht vorhanden muss noch abgefangen werden (bei Generator immer vorhanden!)
// ................ Auswertung Umweltbedingungen erweitert ...........
if (tabseek("NAME", "F_UWB_ERW")) {
tabget(temp, "TYP");
temp[0] = temp[0] | 0x20; // erstes Zeichen in Kleinschrift
if (temp[0] == 0x6E) // Handelt es sich bei dem ersten Zeichen um ein "n" ?
LIUWErweitertExist = 0;
else
LIUWErweitertExist = 1;
}
else
LIUWErweitertExist = 0;
// ................ Auswertung Umweltbedingungs-S<>tze ................
if (tabseek("NAME", "F_UWB_SATZ")) {
tabget(temp, "TYP");
uw_satz_anzahl = atoi(temp);
}
else
uw_satz_anzahl = 2;
// ................ Auswertung SAE-Codes .............................
dataclear(temp);
if (tabseek("NAME", "F_SAE_CODE")) {
tabget(temp, "TYP");
temp[0] = temp[0] | 0x20; // erstes Zeichen in Kleinschrift
if (temp[0] == 0x6E) // Handelt es sich bei dem ersten Zeichen um ein "n" ?
LISaeCodeExist = 0;
else
LISaeCodeExist = 1;
}
else
LISaeCodeExist = 0;
// ................ Auswertung Heilungsz<73>hler ........................
dataclear(temp);
if (tabseek("NAME", "F_HLZ")) {
tabget(temp, "TYP");
temp[0] = temp[0] | 0x20; // erstes Zeichen in Kleinschrift
if (temp[0] == 0x6E) { // Handelt es sich bei dem ersten Zeichen um ein "n" ?
LIHlzExist = 0;
if (F_HLZ)
F_HLZ = -1;
}
else
LIHlzExist = 1;
}
else
LIHlzExist = 0;
// ................ Auswertung Severity-Byte .........................
dataclear(temp);
if (tabseek("NAME", "F_SEVERITY")) {
tabget(temp, "TYP");
temp[0] = temp[0] | 0x20; // erstes Zeichen in Kleinschrift
if (temp[0] == 0x6E) // Handelt es sich bei dem ersten Zeichen um ein "n" ?
severity_exist = 0;
else
severity_exist = 1;
}
else
severity_exist = 0;
// ................ Auswertung Heilungsz<73>hler g<>ltig .........................
// Parameter ist solange erfoderlich, bis das Problem mit dem HLZ im Standard-Core gel<65>st ist
dataclear(temp);
if (tabseek("NAME", "F_HLZ_VIEW")) {
tabget(temp, "TYP");
if (temp[0] == 0x2D) // Handelt es sich bei diesem Zeichen um ein '-'?
LIHlzValid = 1; // Wenn nichts angebenen wird, dann richtet sich die Auswertung allein nach F_HLZ
else
{
temp[0] = temp[0] | 0x20; // erstes Zeichen in Kleinschrift
if (temp[0] == 0x6E) // Handelt es sich bei dem ersten Zeichen um ein "n" ?
LIHlzValid = 0;
else
LIHlzValid = 1;
}
}
else
LIHlzValid = 1; // Wenn nichts angebenen wird, dann richtet sich die Auswertung allein nach F_HLZ
// End of file
// end of : #include "UDS_FS_DetailStruktur.b2s"
#undef DetailStruktur
// ---------------- 1. Kommunikation (Severity) ----------------------
if (severity_exist) {
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) {
if (_RESPONSE_SEVERITY) _RESPONSE_SEVERITY = response;
return;
}
// ---------------- 1. Test: richtiger Fehlercode ? ------------------
if (code != ((response[5] << 16) + (response[6] << 8) + response[7]))
return_with_message("?10?", "ERROR-CODE RESPONSE IS NOT ERROR-CODE REQUEST", response, "_RESPONSE_SEVERITY", 0);
}
// ---------------- Auswertung Severity-Byte -------------------------
if (severity_exist)
severity_byte = (response[3] >> 5) & 0x07; // Es werden nur die obersten 3 Bit ben<65>tigt.
else
severity_byte = 0; // There is no severity information available.
if (F_FEHLERKLASSE_NR)
F_FEHLERKLASSE_NR = severity_byte;
if (F_FEHLERKLASSE_TEXT) {
tabset("Fehlerklasse");
tab_suche_unsigned("NR", severity_byte);
tabget(text,"TEXT");
F_FEHLERKLASSE_TEXT = text;
}
/*
if (_RESPONSE_SEVERITY) // w<>rde im 1. Ergebnissatz abgelegt !
if (severity_exist)
_RESPONSE_SEVERITY = response;
else
_RESPONSE_SEVERITY = "-";
*/
// ---------------- 2. Kommunikation (Extended Data) -----------------
dataclear(request);
dataclear(response);
request = {0x19,0x06,0xFF,0xFF,0xFF,0xFF};
// Service ReadDTCInformation --------+ | | | | |
// SubPara ExtendedDataRecordByDTCNumber --+ | | | |
// DTCNumber -----------------------------------+----+----+ |
// DTCExtendedDataRecordNumber (alle) -------------------------+
request[2] = (code >>16) & 0xFF;
request[3] = (code >> 8) & 0xFF;
request[4] = code & 0xFF;
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) {
if (_RESPONSE_EXTENDED_DATA) _RESPONSE_EXTENDED_DATA = response;
return;
}
response1 = response; // zwischenpuffern, da erst am Ende des Jobs ben<65>tigt
// ---------------- 2. Test: richtiger Fehlercode ? ------------------
if (code != ((response[2] << 16) + (response[3] << 8) + response[4]))
return_with_message("?10?", "ERROR-CODE RESPONSE IS NOT ERROR-CODE REQUEST", response, "_RESPONSE_EXTENDED_DATA", 0);
// ---------------- Zuweisung F-Ort, F-Arten -----------------------
offset = 5; // Startpunkt: Byte "statusOfDTC"
#define OrtTexte "FOrtTexte"
#define ArtTexte "FArtTexte"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_FS_Ort_Art.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : FS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, FOrtTexte, FArtTexte, FDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// FUmweltTexte
// -------------------------------------------------------------------
// Jobname : IS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, IOrtTexte, IArtTexte, IDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// IUmweltTexte
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// -------------------------------------------------------------------
// Hinweise allgemein:
// (1) : JOB_STATUS = "ERROR_TABLE"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// erkannt wird, dass eine Tabelle falsch befuellt ist.
// (2) : JOB_STATUS = "ERROR_INTERPRETATION"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// ein Fall auftritt, der undefiniert ist.
// (Dies sollte normalerweise nie passieren !)
// (1),(2): Das Result "ERROR_MESSAGE" enthaelt zusaetzliche Hinweise.
//
// (3) : EDIABAS_BIP_0010 / CONSTANT DATA ACCESS ERROR
// -> Dieser EDIABAS-Fehler tritt auf, wenn im Job eine Tabellen-
// Spalte, die in der SGBD benutzt wird, nicht existiert
// (z.B. bei fehlerhaft dimensionierten Tabellen).
// Es entsteht deshalb eine EDIABAS-Fehlermeldung, da die
// Ueberpruefung der Tabellen-Spalten erst zur Laufzeit
// geschieht.
// -------------------------------------------------------------------
// History:
// 09.02.2006 gh V0.001 Erstellung
// 15.02.2006 gh V0.002 getestet mit Simulation
// 16.02.2006 gh V0.003 Zuweisung "response1 = response;" entfernt
// 24.03.2006 gh V0.004 Zuweisung Result F_HEX_CODE entfernt
// *******************************************************************
// UDS_FS_Ort_Art.B2S @(#)@ V0.004 @(#)@
// *******************************************************************
// ................ R<>ckgabe buffer l<>schen ..........................
dataclear(temp);
dataclear(text);
dataclear(text1);
// ................ R<>ckgabe Basis-Infos .............................
LIStatusDTC = response[offset] & 0x4D; // Auslesen des Status Bytes. F<>r die Auswertung sind die Bits 0,2,3,6 entscheidend
if (F_ORT_NR || F_ORT_TEXT || F_EREIGNIS_DTC || F_READY_NR || F_READY_TEXT || F_VORHANDEN_NR || F_VORHANDEN_TEXT || F_WARNUNG_NR || F_WARNUNG_TEXT) {
dataclear(temp);
F_ORT_NR = code; // Ausgabe Fehlerort
tabset(OrtTexte); // Dazugehoeriger Fehlertext
tab_suche_unsigned("ORT", code);
tabget(temp, "ORTTEXT");
F_ORT_TEXT = temp;
tabget(temp, "EREIGNIS_DTC"); // Ereignis-DTC ja / nein
F_EREIGNIS_DTC = atoi(temp);
wert = ((response[offset] >> 4) & 0x01) + 0x10; // Gibt an, ob Test seit dem letzten L<>schen einmal komplett durchlaufen wurde
F_READY_NR = wert; // Offset 0x10 wird addiert, um Tabelle FArtTexte verwenden zu k<>nnen
tabset(ArtTexte);
tab_suche_unsigned("ARTNR", wert);
tabget(text, "ARTTEXT");
F_READY_TEXT = text;
F_VORHANDEN_NR = LIStatusDTC; // Fehler aktuell vorhanden? (siehe Matrix in XArtTexte)
tab_suche_unsigned("ARTNR", LIStatusDTC);
tabget(text, "ARTTEXT");
F_VORHANDEN_TEXT = text;
wert = ((response[offset] >> 7) & 0x01) + 0x80; // Geht eine Warnlampe an oder nicht
F_WARNUNG_NR = wert;
tab_suche_unsigned("ARTNR", wert);
tabget(text, "ARTTEXT");
F_WARNUNG_TEXT = text;
}
// end of : #include "UDS_FS_Ort_Art.b2s"
#undef OrtTexte
#undef ArtTexte
// ---------------- Auswertung Extended Data -------------------------
daten_laenge = datalen(response);
offset = 6; // DTCExtendedDataRecordNumber #1
if (daten_laenge == 6) { // Sonderfall: Fehler nicht in SG gespeichert
;
// F_UEBERLAUF = -1;
// F_HFK = -1;
}
else {
offset_start = offset;
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_FS_Extended_Data.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : FS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, FOrtTexte, FArtTexte, FDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// FUmweltTexte
// -------------------------------------------------------------------
// Jobname : IS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, IOrtTexte, IArtTexte, IDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// IUmweltTexte
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// -------------------------------------------------------------------
// Hinweise allgemein:
// (1) : JOB_STATUS = "ERROR_TABLE"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// erkannt wird, dass eine Tabelle falsch befuellt ist.
// (2) : JOB_STATUS = "ERROR_INTERPRETATION"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// ein Fall auftritt, der undefiniert ist.
// (Dies sollte normalerweise nie passieren !)
// (1),(2): Das Result "ERROR_MESSAGE" enthaelt zusaetzliche Hinweise.
//
// (3) : EDIABAS_BIP_0010 / CONSTANT DATA ACCESS ERROR
// -> Dieser EDIABAS-Fehler tritt auf, wenn im Job eine Tabellen-
// Spalte, die in der SGBD benutzt wird, nicht existiert
// (z.B. bei fehlerhaft dimensionierten Tabellen).
// Es entsteht deshalb eine EDIABAS-Fehlermeldung, da die
// Ueberpruefung der Tabellen-Spalten erst zur Laufzeit
// geschieht.
// -------------------------------------------------------------------
// History:
// 09.02.2006 gh V0.001 Erstellung
// 15.02.2006 gh V0.002 getestet mit Simulation
// 20.02.2006 gh V0.003 Entfernung "new_set_of_results();"
// 14.03.2008 gr V0.004 Abfrage, ob Heilungsz<73>hler angezeigt werden soll
// *******************************************************************
// UDS_FS_Extended_Data.B2S @(#)@ V0.004 @(#)@
// *******************************************************************
// ................ Solange noch Eintr<74>ge vorhanden sind .............
while (offset < (datalen(response))) {
LIExtendedRecordNumber = response[offset];
tabset("DTCExtendedDataRecordNumber");
tab_suche_unsigned("WERT", LIExtendedRecordNumber);
tabget(temp, "ANZ_BYTE");
LILaengeData = atoi(temp);
LLData = 0;
while (LILaengeData > 0) { // Anzahl der Bytes
offset = offset + 1;
LLData = LLData + (response[offset] << ((LILaengeData - 1) * 8));
LILaengeData--;
}
if (LIExtendedRecordNumber == 0x01) { // Condition-Byte ist Pflicht
if (F_UEBERLAUF)
F_UEBERLAUF = LLData & 0x01;
}
if (LIExtendedRecordNumber == 0x02) { // Haeufigkeitszaehler ist Pflicht
if (F_HFK)
F_HFK = LLData;
}
if ((LIExtendedRecordNumber == 0x03) && (LIHlzExist == 1) && (LIHlzValid == 1)) { // Heilungsz<73>hler (optional)
if (F_HLZ)
F_HLZ = LLData;
}
offset = offset + 1;
}
// end of : #include "UDS_FS_Extended_Data.b2s"
// Abfrage, nach LIHlzValid darf nicht gemacht werden, da sonst Telegramml<6D>nge nicht mehr stimmt.
if (((LIHlzExist == 1) && ((datalen(response) - offset_start) != 6)) ||
((LIHlzExist != 1) && ((datalen(response) - offset_start) != 4))) {
return_with_message("?12?", "INCORRECT NUMBER OF DATA IN RESPONSE-TELEGRAM", response1,"_RESPONSE_EXTENDED_DATA", 1);
}
}
// ---------------- 3. Kommunikation (Snapshots) ---------------------
dataclear(request);
dataclear(response);
dataclear(text);
request = {0x19,0x04,0xFF,0xFF,0xFF,0xFF};
// Service ReadDTCInformation --------+ | | | | |
// SubPara SnapshotRecordByDTCNumber-------+ | | | |
// DTCNumber------------------------------------+----+----+ |
// DTCSnapshotRecordNumber (alle)------------------------------+
request[2] = (code >>16) & 0xFF;
request[3] = (code >> 8) & 0xFF;
request[4] = code & 0xFF;
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) {
if (_RESPONSE_SNAPSHOT) _RESPONSE_SNAPSHOT = response;
if (_RESPONSE_EXTENDED_DATA) _RESPONSE_EXTENDED_DATA = response1;
return;
}
// ................ Zuweisung F_HEX_CODE (ohne Severity!) ............
if (F_HEX_CODE) {
text1 = response1; // Extended Data
dataerase(text1, 0, 2);
text = response; // Snapshots
dataerase(text, 0, 2);
datacat(text, text1);
F_HEX_CODE = text;
}
// ---------------- 3. Test: richtiger Fehlercode ? ------------------
if (code != ((response[2] << 16) + (response[3] << 8) + response[4])) {
new_set_of_results();
if (_RESPONSE_EXTENDED_DATA) _RESPONSE_EXTENDED_DATA = response1;
return_with_message("?10?", "ERROR-CODE RESPONSE IS NOT ERROR-CODE REQUEST", response, "_RESPONSE_SNAPSHOT", 0);
}
// ---------------- Auswertung Snapshots -----------------------------
daten_laenge = datalen(response);
offset = 7; // Ab dem 8. Byte beginnen die relevanten Nutzdaten
LISnapshotNumber = 1;
while (LISnapshotNumber <= uw_satz_anzahl) { // Es gibt maximal uw_satz_anzahl Snapshots
LIAnzUW = 0; // Anzahl der zusaetzlichen Umweltbedingungen zuruecksetzen
LLAnzahlSnapshotIdentifier = response[offset]; // Anzahl der Identifier f<>r diesen Snapshot
LICounterIdentifier = LLAnzahlSnapshotIdentifier;
if (daten_laenge == 6) { // Sonderfall: Fehler nicht in SG gespeichert
F_UW_ANZ = 0;
// F_UW_KM = -1;
// F_UW_ZEIT = -1;
offset = daten_laenge; // sonst JOB_STATUS ungleich "OKAY"
new_set_of_results(); // neuer Ergebnissatz !
break;
}
if (LLAnzahlSnapshotIdentifier < 2) { // Abbruch, wenn zu wenig Daten in SG-Antwort
new_set_of_results();
if (_RESPONSE_EXTENDED_DATA) _RESPONSE_EXTENDED_DATA = response1;
return_with_message("?12?", "OBLIGATORY SNAPSHOTS (MILAGE / TIME) ARE MISSING", response,"_RESPONSE_SNAPSHOT", 0);
}
offset = offset + 1;
LICounterUW = 1; // Z<>hler der Umweltbedingungen zur<75>ck setzen
uw_gueltig = 1;
while (LICounterIdentifier > 0) {
#define UmweltTexte "FUmweltTexte"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_FS_Snapshot.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : FS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, FOrtTexte, FArtTexte, FDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// FUmweltTexte
// -------------------------------------------------------------------
// Jobname : IS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, IOrtTexte, IArtTexte, IDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// IUmweltTexte
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// -------------------------------------------------------------------
// Hinweise allgemein:
// (1) : JOB_STATUS = "ERROR_TABLE"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// erkannt wird, dass eine Tabelle falsch befuellt ist.
// (2) : JOB_STATUS = "ERROR_INTERPRETATION"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// ein Fall auftritt, der undefiniert ist.
// (Dies sollte normalerweise nie passieren !)
// (1),(2): Das Result "ERROR_MESSAGE" enthaelt zusaetzliche Hinweise.
//
// (3) : EDIABAS_BIP_0010 / CONSTANT DATA ACCESS ERROR
// -> Dieser EDIABAS-Fehler tritt auf, wenn im Job eine Tabellen-
// Spalte, die in der SGBD benutzt wird, nicht existiert
// (z.B. bei fehlerhaft dimensionierten Tabellen).
// Es entsteht deshalb eine EDIABAS-Fehlermeldung, da die
// Ueberpruefung der Tabellen-Spalten erst zur Laufzeit
// geschieht.
// -------------------------------------------------------------------
// History:
// 09.02.2006 gh V0.001 Erstellung
// 15.02.2006 gh V0.002 getestet mit Simulation
// 20.02.2006 gh V0.003 Umbenennung F_UW_ZEIT_DATUM => F_UW_DATUM_ZEIT
// 22.02.2006 gh V0.004 Integration Subtabellen Tab_<Index>
// 24.03.2006 gh V0.005 Sonderfall 0xFFFFFF bei F_UW_KM
// 24.03.2006 gh V0.005 Sonderfall 0xFFFFFFFF bei F_UW_DATUM_ZEIT
// 24.03.2006 gh V0.005 Korrektur Schaltjahrberechnung
// 27.03.2006 gh V0.006 diskrete UW: real bei F_UWi_WERT, zusammengesetzter Text bei F_UWi_TEXT
// 27.03.2006 gh V0.006 Format bei F_UW_DATUM_ZEIT optimiert
// 29.03.2006 gh V0.006 Trace-Meldungen bzgl. return_with_message optimiert
// 28.06.2006 gh V0.007 Zuweisung Result "F_UW_DATUM_ZEIT" auskommentiert
// 19.10.2006 gh V0.020 $19 $04: komplexe UWB: Ausgabe als Text (string)
// 03.12.2007 rd V0.021 Bug behoben bei hex, text Abfrage
// 21.02.2008 gr V0.022 Auskommentierten Teil F_UW_DATUM_ZEIT entfernt
// 21.02.2008 gr V0.022 Bei SAE-Codes von Tabelle T_SCOD auf Tabelle T_PCOD umgestellt
// 21.02.2008 gr V0.022 Bei SAE-Codes werden nur die ersten beiden Byte verwendet
// 21.02.2008 gr V0.022 Zus<75>tzliche Eintr<74>ge der Tabelle DTCSnapshotIdentifier m<>glich
// 12.03.2010 gh V0.030 Sub-Tabellen f<>r diskrete UW: Spaltenname "UWTEXT" oder "TEXT" m<>glich
// *******************************************************************
// UDS_FS_Snapshot.B2S @(#)@ V0.030 @(#)@
// *******************************************************************
uw_laenge = 0; // Laenge der Umweltbedingung zuruecksetzen
uw_typ = 0x00;
LIIdentifier = (response[offset] << 8) + response[offset+1];
offset = offset + 2; // bei digitaler oder diskreter UW nicht grunds<64>tzlich weiterschalten !!!
// Einlesen des Identifier
tabset("DTCSnapshotIdentifier");
if (tab_suche_unsigned("UWNR", LIIdentifier) == 0) { // Falls der Identifier nicht in der Standard-UW-Tabelle enthalten ist, muss die spezielle Tabelle ausgewertet werden
if (LIUWErweitertExist == 1) {
tabset(UmweltTexte);
if (tab_suche_unsigned("UWNR", LIIdentifier) == 0) { // Falls der Identifier auch nicht in der speziellen UW-Tabelle enthalten ist => Fehler
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?12?", "IDENTIFIER NOT DEFINED", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?12?", "IDENTIFIER NOT DEFINED", response,"_RESPONSE_200X", 0);
}
}
}
else {
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?12?", "IDENTIFIER NOT DEFINED", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?12?", "IDENTIFIER NOT DEFINED", response,"_RESPONSE_200X", 0);
}
}
} // Ende 'if (tab_suche_unsigned("UWNR", LIIdentifier) == 0)'
// ... Standard-Identifier (KM, Zeit, SAE-Code) ......................
if (LIIdentifier == 0x1700 || LIIdentifier == 0x1701 || LIIdentifier == 0x1702) {
if (LIIdentifier == 0x1700) { // KM-Stand
uw_laenge = 3;
LLData = (response[offset] << 16) + (response[offset+1] << 8) + (response[offset+2]);
if (LLData == 0xFFFFFF) // Bei 0xFFFFFF steht der KM-Stand nicht zur Verf<72>gung.
LLData = -1; // Hier soll analog zu F_UW_ZEIT der Wert -1 kommen.
if (F_UW_KM)
var_result_long("F_UW_KM", LLData);
}
// Auswertung des Datensatzes
if (LIIdentifier == 0x1701) { // Absolute Zeit
uw_laenge = 4;
LLData = (response[offset] << 24) + (response[offset+1] << 16) + (response[offset+2] << 8) + (response[offset+3]); // Angabe der Zeit seit 01.01.2000
zeit_aktuell = LLData;
if (F_UW_ZEIT)
var_result_long("F_UW_ZEIT", zeit_aktuell);
} // Ende 'if (LIIdentifier == 0x1701)'
// Auswertung des Datensatzes
if (LIIdentifier == 0x1702) { // SAE-Code
uw_laenge = 3;
// alte Zuordnung
// LLData = (response[offset] << 16) + (response[offset+1] << 8) + (response[offset+2]);
// Bei den SAE-Codes werden doch nur die ersten beiden Bytes belegt
// Da ein 3-Byte-Wert geliefert wird, wird das letzte Byte abgeschnitten
LLData = (response[offset] << 8) + response[offset+1];
if (F_SAE_CODE)
F_SAE_CODE = LLData;
tabsetext("T_PCOD","PCodeTexte");
tab_suche_unsigned("PCODE", LLData);
if (F_SAE_CODE_STRING) {
tabget(text, "STRING");
F_SAE_CODE_STRING = text;
}
if (F_SAE_CODE_TEXT) {
tabget(text, "TEXT");
F_SAE_CODE_TEXT = text;
}
}
} // Ende IF-Zweig 'if (LIIdentifier == 0x1700 || LIIdentifier == 0x1701 || LIIdentifier == 0x1703)'
// ... SG-spezifischer Identifier ....................................
else {
uw_sub_index = 0;
// . . f<>r alle Sub-Identifier . . . . . . . . . . . . . . . . . . . .
do {
// . . nur beim ersten Mal . . . . . . . . . . . . . . . . . . . . . .
if (uw_sub_index == 0) {
identifier_sub = LIIdentifier;
set_trap_mask(0x0400); // Trap-Bit f<>r Tabellenzugriff setzen
strcpy(text, "Tab_");
itoax(temp, identifier_sub);
dataerase(temp, 2, 4);
strcat(text, temp);
tabset(text); // Erweiterungsmatrix <20>ffnen
set_trap_mask(0); // Trap-Bit f<>r Tabellenzugriff ruecksetzen
if (get_error(10)) { // Sub-Tabelle existiert nicht
uw_sub_index = 0; // keine Aktion
}
else { // Sub-Tabelle existiert
++uw_sub_index; // 1. Wert: uw_sub_index = 1;
tabline(0);
tabget(text1, "UW_ANZ");
uw_sub_anz = atoi(text1);
}
}
// . . ab dem ersten Mal . . . . . . . . . . . . . . . . . . . . . . .
if (uw_sub_index > 0) {
if (uw_sub_index <= uw_sub_anz) { // Suchen in Zusatz-Matrix
strcpy(text, "Tab_");
itoax(temp, identifier_sub);
dataerase(temp, 2, 4);
strcat(text, temp);
tabset(text); // Erweiterungsmatrix <20>ffnen
tabline(0);
itoad(temp, uw_sub_index);
strinsert(temp, "UW", 0);
strcat(temp, "_NR");
tab2fix(LIIdentifier, temp); // neue "uw_nr" aus Zusatz-Matrix
if (uw_sub_index == uw_sub_anz) { // ! letzter digit./diskr. Wert
// ++uw_sub_anz;
uw_sub_index = 0;
}
else // sonst: weiterschalten !
++uw_sub_index;
}
else { // !!! darf eigentlich nie vorkommen
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?12?", "INCREMENT (++uw_sub_index)", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?12?", "INCREMENT (++uw_sub_index)", response,"_RESPONSE_200X", 0);
}
}
}
// . . UW normal abarbeiten . . . . . . . . . . . . . . . . . . . . .
LIAnzUW++; // Anzahl der echten UW-Bedingungen hochzaehlen
text = "F_UW";
itoad(text1, LIAnzUW);
strinsert(text1, text , 0);
// Es wird zuerst die Standard-Tabelle durchsucht
tabset("DTCSnapshotIdentifier");
if (tab_suche_unsigned("UWNR", LIIdentifier) == 0)
tabset(UmweltTexte); // Wenn in der Standard-Tabelle der Eintrag nicht enthalten ist, dann wird auf die spezifische UW-Daten gegangen
tab_suche_unsigned("UWNR", LIIdentifier); // (wieder) in die richtige Zeile springen
tabget(text, "UW_EINH"); // !!! >> "text" wird noch gebraucht (F_UWn_EINH)
if (!strcmp(text, "0/1"))
uw_typ = uw_typ_digital; // ! Typ -> digital
else if (!strcmp(text, "0-n"))
uw_typ = uw_typ_diskret; // ! Typ -> diskret
else {
temp = text;
temp[0] = temp[0] | 0x20; // ! Kleinschrift (1. Zeichen) h t
temp[1] = temp[1] | 0x20; // ! Kleinschrift (2. Zeichen) e e
temp[2] = temp[2] | 0x20; // ! Kleinschrift (3. Zeichen) x x
if (temp[3] != 0x00) // V0.021
temp[3] = temp[3] | 0x20; // ! Kleinschrift (4. Zeichen) \0 t
if (!strcmp(temp, "hex"))
uw_typ = uw_typ_hex; // ! Typ -> hex (neu)
else if (!strcmp(temp, "text"))
uw_typ = uw_typ_text; // ! Typ -> text (neu)
else
uw_typ = uw_typ_analog; // ! Typ -> analog (evtl. -> real (siehe unten))
} // Ende ELSE-Zweig !strcmp(text
// . . Zuweisung Result "F_UWn_NR" . . . . . . . . . . . . . . . . . .
temp = text1;
strcat(temp, "_NR");
var_result_long(temp, LIIdentifier);
// . . Zuweisung Result "F_UWn_TEXT" . . . . . . . . . . . . . . . . .
/***
tabget(text, "UWTEXT");
temp = text1;
strcat(temp, "_TEXT");
var_result_string(temp, text);
***/
// . . Zuweisung Result "F_UWn_EINH" . . . . . . . . . . . . . . . . .
tabget(text, "UW_EINH");
temp = text1;
strcat(temp, "_EINH");
var_result_string(temp, text);
// . . Aufschluesselung des Types um die Laenge der UW zu ermitteln
tabget(text, "UWTYP");
if ((uw_typ & uw_typ_analog) || (uw_typ & uw_typ_hex)) {
get_token(temp, text, " ", 1);
temp[0] = temp[0] | 0x20; // ! immer Kleinschrift
if (temp[0] == 's') // unsigned / signed
uw_typ = uw_typ | uw_typ_signed; // ! hier : "ODER"
if (temp[0] == 'm') // Intel / Motorola
uw_typ = uw_typ | uw_typ_Motorola; // ! hier : "ODER"
// . . Feststellen der Art der UW (3) Datentyp -> "uw_laenge" . . . .
get_token(temp, text, " ", 2);
temp[0] = temp[0] | 0x20; // ! immer Kleinschrift
if (temp[0] == 'c') // char
uw_laenge = 1;
else if (temp[0] == 'i') // int
uw_laenge = 2;
else if (temp[0] == 'l') // long
uw_laenge = 4;
else if (temp[0] == 'f') { // float
uw_laenge = 4;
uw_typ = uw_typ | uw_typ_float; // ! Typ -> float (! hier : "ODER")
}
else if (temp[0] == 'd') { // double
uw_laenge = 8;
uw_typ = uw_typ | uw_typ_double; // ! Typ -> double (! hier : "ODER")
}
else { // ! Default: FEHLER
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?0A?", "NOT DEFINED TYPE (use: char, int, long, float, double)", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?0A?", "NOT DEFINED TYPE (use: char, int, long, float, double)", response,"_RESPONSE_200X", 0);
}
}
}
else if (uw_typ & uw_typ_text)
uw_laenge = atoi(text); // Fehlerbehandlung ?
else if ((uw_typ & uw_typ_digital) || (uw_typ & uw_typ_diskret))
uw_laenge = (strlen(text) - 2) / 2;
// z.B.: 0x4321 => 1.) strlen()-2=4 (ohne "0x")
// 2.) 4 /2=2 (2 Hex-Ziffern pro Byte)
// else FEHLERMELDUNG
// ---------------------------------
// Zuweisung WERT
// . . Puffer f<>r Ergebnis zuweisen (uw_wert_real, uw_wert_mask, uw_wert, ...)
if (uw_gueltig == 1) { //Nur bei gueltiger UW
if ((uw_typ & uw_typ_float) || (uw_typ & uw_typ_double)) // analoger Wert (real)
data_to_real(uw_wert_real, response, offset, uw_laenge-4, uw_typ & uw_typ_Motorola);
else if (uw_typ & uw_typ_text) { // string mit n Bytes
tabget(temp, "L/H"); // Auswertung Byte-Order
temp[0] = temp[0] | 0x20; // ! immer Kleinschrift
if (temp[0] == 'l')
uw_typ = uw_typ | uw_typ_low_high; // ! hier : "ODER"
}
else { // Analogwert (long) oder digitaler/diskreter Wert . . . . . .
tabget(temp, "L/H"); // Auswertung Byte-Order
temp[0] = temp[0] | 0x20; // ! immer Kleinschrift
if (temp[0] == 'l')
uw_typ = uw_typ | uw_typ_low_high; // ! hier : "ODER"
switch (uw_laenge) {
case 4: // signed long / ! unsigned long NICHT moeglich
// Sonderfall: Fuer Bitmasken unsigned erforderlich falls das hoechste Bit gesetzt ist
if ((uw_typ & uw_typ_digital) || (uw_typ & uw_typ_diskret)) {
if (uw_typ & uw_typ_low_high) // low / middle_l / middle_h / high
uw_wert_mask = response[offset]+ (response[offset+1] << 8) + (response[offset+2] << 16) + (response[offset+3] << 24);
else // high / middle_h / middle_l / low
uw_wert_mask = (response[offset] << 24) + (response[offset+1] << 16) + (response[offset+2] << 8) + response[offset+3];
}
else { // Normalfall: analoger Wert (signed)
if (uw_typ & uw_typ_low_high) // low / middle_l / middle_h / high
uw_wert = response[offset] + (response[offset+1] << 8) + (response[offset+2] << 16) + (response[offset+3] << 24);
else // high / middle_h / middle_l / low
uw_wert = (response[offset] << 24) + (response[offset+1] << 16) + (response[offset+2] << 8) + response[offset+3];
}
break;
case 2: // unsigned int
if (uw_typ & uw_typ_low_high) // low / high
uw_wert = response[offset] + (response[offset+1] << 8);
else
uw_wert = (response[offset ] << 8) + response[offset+1];
if (uw_typ & uw_typ_signed) { // -> signed
if (uw_wert > 32767)
uw_wert = uw_wert - 65536;
}
uw_wert_mask = uw_wert; // bei int kein Unterschied
break;
case 1: // unsigned char
uw_wert = response[offset];
if (uw_typ & uw_typ_signed) { // -> signed
if (uw_wert > 127)
uw_wert = uw_wert - 256;
}
uw_wert_mask = uw_wert; // bei char kein Unterschied
break;
default: // ! Default: FEHLER
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?0A?", "LENGTH (BYTES) OF ENVIRONMENT CONDITION NOT ALLOWED", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?0A?", "LENGTH (BYTES) OF ENVIRONMENT CONDITION NOT ALLOWED", response,"_RESPONSE_200X", 0);
}
} // Ende 'switch (uw_laenge)'
} // Ende else Zweig von 'if ((uw_typ & uw_typ_float) || (uw_typ & uw_typ_double))'
// . . 1. Fall: digitale UW . . . . . . . . . . . . . . . . . . . . .
if (uw_typ & uw_typ_digital) {
tabget(temp, "UWTYP");
if (uw_laenge == 4) { // ! Ein Wert vom Typ "unsigned long" kann !
text = temp; // ! mit "atoi" nicht direkt interpretiert werden !
strerase(temp, 6, 4); // ! -> (1) Aufteilung in 2 "int"-Werte !
uw_mask = atoi(temp) & 0xFFFF;// ! -> (2) anschliessend zusammensetzen !
uw_mask = uw_mask << 16;
strerase(text, 2, 4);
uw_mask = uw_mask | (atoi(text) & 0xFFFF);
}
else // Normalfall: direkte Wandlung
uw_mask = atoi(temp);
if ((uw_wert_mask & uw_mask) == uw_mask)
uw_wert = 1;
else
uw_wert = 0;
itor(uw_wert_real, uw_wert); // -> real
} // Ende 'if (uw_typ & uw_typ_digital)'
// . . 2. Fall: diskrete UW . . . . . . . . . . . . . . . . . . . . .
else if (uw_typ & uw_typ_diskret) {
// ! tab2fix(uw_mask, "UWTYP"); // ! funktioniert nicht fuer hoechstes Bit
tabget(temp, "UWTYP");
if (uw_laenge == 4) { // ! Ein Wert vom Typ "unsigned long" kann !
strerase(temp, 6, 4); // ! mit "atoi" nicht direkt interpretiert werden !
uw_mask = atoi(temp) & 0xFFFF; // ! -> (1) Aufteilung in 2 "int"-Werte !
uw_mask = uw_mask << 16; // ! -> (2) anschliessend zusammensetzen !
tabget(temp, "UWTYP");
strerase(temp, 2, 4);
uw_mask = uw_mask | (atoi(temp) & 0xFFFF);
}
else // Normalfall: direkte Wandlung
uw_mask = atoi(temp);
tabget(text, "NAME"); // Zusatztabelle <Name>
set_trap_mask(0x0400); // Trap-Bit f<>r Tabellenzugriff setzen
tabset(text); // Tabelle bzgl. diskreter Werte oeffnen
if (get_error(10)) {
text1 = "Table not found";
strinsert(text1, text, 6);
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?0A?", text1, response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?0A?", text1, response,"_RESPONSE_200X", 0);
}
}
set_trap_mask(0); // Trap-Bit f<>r Tabellenzugriff ruecksetzen
uw_wert_mask = uw_wert_mask & uw_mask; // ! beide Masken unsigned int
itor(uw_wert_real, uw_wert_mask); // -> real (f<>r F_UWi_WERT) /*** ***/
tab_suche_unsigned("WERT", uw_wert_mask);
set_trap_mask(0x0400); // Trap-Bit f<>r Tabellenzugriff setzen
tabget(text, "UWTEXT"); // !!! >> "text1" wird noch gebraucht (F_UWn_WERT)
set_trap_mask(0); // Trap-Bit f<>r Tabellenzugriff ruecksetzen
if (get_error(10))
tabget(text, "TEXT"); // !!! >> "text1" wird noch gebraucht (F_UWn_WERT)
} // Ende 'else if (uw_typ & uw_typ_diskret)' !!! >> "text" wird noch gebraucht (F_UWn_TEXT)
// . . 3 Fall: UW vom Typ Hex . . . . . . . . . . . . . . . . . . . .
else if (uw_typ & uw_typ_hex) {
itoax(text, uw_wert); // !!! >> "text1" wird noch gebraucht (F_UWn_WERT)
strerase(text, 0, 10 - (2 * uw_laenge)) ; // Anzahl: 2 + (8 - (2 * uw_laenge))
}
// . . 4 Fall: UW vom Typ text . . . . . . . . . . . . . . . . . . .
else if (uw_typ & uw_typ_text) {
; // keine Ergebnisberechnung erforderlich
}
// . . 5 Fall: analoge UW . . . . . . . . . . . . . . . . . . . . . .
else if (uw_typ & uw_typ_analog) {
// ! nur bei long: d.h. nicht float / nicht double
if (!(uw_typ & uw_typ_float) && !(uw_typ & uw_typ_double))
itor(uw_wert_real, uw_wert); // <Bytes aus SG-Antwort> -> real
tabget(temp, "MUL"); // Multiplikator MUL
if (!strcmp(temp, "-") || !strcmp(temp, "--")) // bei "-" oder "--"
temp = "1"; // Default : 1
ator(uw_mul_real, temp); // -> real
tabget(temp, "DIV"); // Divisor DIV
if (!strcmp(temp, "-") || !strcmp(temp, "--")) // bei "-" oder "--"
temp = "1"; // Default : 1
ator(uw_div_real, temp); // -> real
ator(uw_add_real, "0.0"); // uw_add_real kurzfristig als (real) 0.0
if (realcomp(uw_div_real, "==", uw_add_real)) { // ! FEHLER (Division durch "0")
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?0A?", "DIVISION BY ZERO", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?0A?", "DIVISION BY ZERO", response,"_RESPONSE_200X", 0);
}
}
tabget(temp, "ADD"); // Offset ADD
if (!strcmp(temp, "-") || !strcmp(temp, "--")) // bei "-" oder "--"
temp = "0"; // Default : 0
ator(uw_add_real, temp); // -> real
realmul (uw_wert_real, uw_mul_real); // uw_wert_real = ( uw_wert_real * uw_mul_real
realdiv (uw_wert_real, uw_div_real); // / uw_div_real)
realadd (uw_wert_real, uw_add_real); // + uw_add_real;
} // Ende 'else if (uw_typ & uw_typ_analog'
// . . 6 Fall: Fehler, da nichts passt . . . . . . . . . . . . . . .
else {
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?12?", "TYPE uw_typ NOT DEFINED (1)", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?12?", "TYPE uw_typ NOT DEFINED (1)", response,"_RESPONSE_200X", 0);
}
}
// . . Zuweisung Result "F_UWn_WERT" . . . . . . . . . . . . . . . . .
temp = text1;
strcat(temp, "_WERT");
/***
if ((uw_typ & uw_typ_diskret) || (uw_typ & uw_typ_hex)) // (string) bei diskreten UW (string) bei UW vom Typ "Hex"
var_result_string(temp, text); // !!! << text1 wieder frei
else // (real) bei sonstigen UW
var_result_real(temp, uw_wert_real);
***/
if (uw_typ & uw_typ_hex) // (string) bei UW vom Typ "Hex"
var_result_string(temp, text);
else if (uw_typ & uw_typ_text) { // (string) mit VS (Hr. Graf) abgestimmt !
dataclear(temp);
datacopy(temp, response, offset, uw_laenge);
if (uw_typ & uw_typ_low_high)
datarevers(temp);
hex2ascii(text, temp, 0, uw_laenge);
temp = text1;
strcat(temp, "_WERT");
var_result_string(temp, text);
}
else // (real) bei sonstigen UW
var_result_real(temp, uw_wert_real);
// . . Zuweisung Result "F_UWn_TEXT" . . . . . . . . . . . . . . . . . /*** ***/
temp = text1; // !!! << text1 wieder frei
strcat(temp, "_TEXT");
// Es wird zuerst die Standard-Tabelle durchsucht
tabset("DTCSnapshotIdentifier");
if (tab_suche_unsigned("UWNR", LIIdentifier) == 0)
tabset(UmweltTexte); // Wenn in der Standard-Tabelle der Eintrag nicht enthalten ist, dann wird auf die spezifische UW-Daten gegangen
tab_suche_unsigned("UWNR", LIIdentifier); // (wieder) in die richtige Zeile springen
tabget(text1, "UWTEXT");
if (uw_typ & uw_typ_diskret) {
strcat(text1, ": ");
strcat(text1, text);
}
var_result_string(temp, text1);
} // Ende 'if (uw_gueltig == 1) '
} while (uw_sub_index); // f<>r alle Sub-Identifier abarbeiten !
} // Ende else-Zweig von 'if (LIIdentifier == 0x1700 || LIIdentifier == 0x1701 || LIIdentifier == 0x1703)'
offset = offset + uw_laenge; // bei digitaler oder diskreter UW nicht grunds<64>tzlich weiterschalten !!!
// End of File
// end of : #include "UDS_FS_Snapshot.b2s"
#undef UmweltTexte
if (offset > daten_laenge) { // Der neue Offset ist l<>nger als die Datenl<6E>nge
uw_gueltig = 0; // ! keine Resultbildung mehr
new_set_of_results();
if (_RESPONSE_EXTENDED_DATA) _RESPONSE_EXTENDED_DATA = response1;
return_with_message("?0A?", "TOO MUCH DATA IN RESPONSE-TELEGRAM", response,"_RESPONSE_SNAPSHOT", 0);
}
else
LICounterUW++;
// . . nach Bearbeitung eines kompletten UW-Satzes . . . . . . . . . .
// . . nach Bearbeitung aller UW-Saetze . . . . . . . . . . . . . . .
LICounterIdentifier--;
} // Ende 'while(LLCounterIdentifier > 0)'
if (offset < daten_laenge) {
LISnapshotNumber++;
offset = offset + 1; // Byte DTCSnapshotRecordNumber = 2 oder 3 wird nicht ausgewertet
}
else
LISnapshotNumber = uw_satz_anzahl + 1; // = Abbruchkriterium f<>r while-Schleife
// LISnapshotNumber = 3; // = Abbruchkriterium f<>r while-Schleife
if (F_UW_ANZ) // Anzahl der zusaetzlichen Umweltbedingungen ausgeben
F_UW_ANZ = LIAnzUW;
new_set_of_results(); // neuer Ergebnissatz
} // Ende 'while (LISnapshotNumber < uw_satz_anzahl+1)'
// ---------------- JOB_STATUS,_RESPONSE* ---------------------------
if (_RESPONSE_SNAPSHOT)
_RESPONSE_SNAPSHOT = response;
if (_RESPONSE_EXTENDED_DATA)
_RESPONSE_EXTENDED_DATA = response1;
if (_RESPONSE_SEVERITY)
if (severity_exist)
_RESPONSE_SEVERITY = "?"; // erst m<>glich, wenn mehr als 6 Array-Variablen zur Verf<72>gung stehen!
else
_RESPONSE_SEVERITY = "-";
if ((offset - daten_laenge) == 0)
JOB_STATUS = "OKAY";
else
return_with_message("?12?", "INCORRECT NUMBER OF DATA IN RESPONSE-TELEGRAM", response,"_RESPONSE_SNAPSHOT", 0);
}
// End of File
// end of : #include "UDS_19_04_06_FS_LESEN_DETAIL.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_14_FS_LOESCHEN.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : FS_LOESCHEN
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 22.03.2005 gh V0.001 Erstellung
// 14.11.2005 gr V0.002 Anpassung auf send_and_receive_uds
// Einbau optionales Argument F_CODE
// 01.02.2006 gr V0.003 Fehler bei Interpretation des optionalen Arguments behoben
// 10.02.2006 gh V0.004 lokale Variable "code" von int auf long erweitert
// *******************************************************************
// UDS_14_FS_LOESCHEN.B2S @(#)@ V0.004@(#)@
// *******************************************************************
job ( name : FS_LOESCHEN;
comment : Fehlerspeicher loeschen;
comment : UDS : $14 ClearDiagnosticInformation;
comment : UDS : $FF DTCHighByte;
comment : UDS : $FF DTCMiddleByte;
comment : UDS : $FF DTCLowByte;
comment : Modus: Default;
argument : F_CODE;
type : long;
comment : 0x??????: Angabe eines einzelnen Fehlers;
comment : Default:;
comment : 0xFFFFFF: alle Fehler;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// Variablen fuer Kommunikation
unsigned char request[] = {0x14, 0xFF, 0xFF, 0xFF};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// Variablen fuer Job
unsigned long code; // Fehlercode (in "auftrag")
// ---------------- Argumente des Jobs auswerten ---------------------
if (exist(F_CODE)) {
code = F_CODE;
request[1] = (code >>16) & 0xFF;
request[2] = (code >> 8) & 0xFF;
request[3] = code & 0xFF;
}
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_14_FS_LOESCHEN.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_10_00_PRUEFSTEMPEL_LESEN.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VERAENDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : PRUEFSTEMPEL_LESEN
// -------------------------------------------------------------------
// Globale Variable : SG_Adresse
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// Gueltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 22.03.2005 gh V0.001 Erstellung
// 28.07.2005 gh V0.002 Namens<6E>nderung dieser Datei
// 28.07.2005 gh V0.002 Entfernung defrslt
// 18.11.2005 gr V0.003 Anpassung send_and_receice_uds
// 02.02.2006 gh V0.004 Include-Name ge<67>ndert (wie Job-Name)
// *******************************************************************
// UDS_22_10_00_PRUEFSTEMPEL_LESEN.B2S @(#)@ V0.003 @(#)@
// *******************************************************************
job ( name : PRUEFSTEMPEL_LESEN;
comment : Auslesen des Pruefstempels;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $1000 TestStamp;
comment : Modus: Default;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : BYTE1;
type : int;
comment : Bereich: 0-255 bzw. 0x00-0xFF;
result : BYTE2;
type : int;
comment : Bereich: 0-255 bzw. 0x00-0xFF;
result : BYTE3;
type : int;
comment : Bereich: 0-255 bzw. 0x00-0xFF;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x22, 0x10, 0x00};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (BYTE1)
BYTE1 = response[3];
if (BYTE2)
BYTE2 = response[4];
if (BYTE3)
BYTE3 = response[5];
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_22_10_00_PRUEFSTEMPEL_LESEN.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_2E_10_00_PRUEFSTEMPEL_SCHREIBEN.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VERAENDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : PRUEFSTEMPEL_SCHREIBEN
// -------------------------------------------------------------------
// Globale Variable : SG_Adresse
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// Gueltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 22.03.2005 gh V0.001 Erstellung
// 28.07.2005 gh V0.002 Namens<6E>nderung dieser Datei
// 28.07.2005 gh V0.002 Entfernung defrslt
// 18.11.2005 gr V0.003 Anpassung send_and_receice_uds
// 28.11.2005 rd V0.004 Result JOB_STATUS dazu
// 02.02.2006 gh V0.005 Include-Name ge<67>ndert (wie Job-Name)
// *******************************************************************
// UDS_2E_10_00_PRUEFSTEMPEL_SCHREIBEN.B2S @(#)@ V0.005@(#)@
// *******************************************************************
job ( name : PRUEFSTEMPEL_SCHREIBEN;
comment : Beschreiben des Pruefstempels;
comment : Es muessen immer alle drei Argumente im Bereich;
comment : von 0-255 bzw. 0x00-0xFF uebergeben werden.;
comment : UDS : $2E WriteDataByIdentifier;
comment : UDS : $1000 TestStamp;
comment : Modus: Default;
argument : BYTE1;
type : int;
comment : Bereich: 0-255 bzw. 0x00-0xFF;
argument : BYTE2;
type : int;
comment : Bereich: 0-255 bzw. 0x00-0xFF;
argument : BYTE3;
type : int;
comment : Bereich: 0-255 bzw. 0x00-0xFF;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x2E, 0x10, 0x00, 0x00, 0x00, 0x00};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
int wert1;
int wert2;
int wert3;
// ---------------- Argumente des Jobs auswerten ---------------------
if (exist(BYTE1)) { // 1. Byte
wert1 = BYTE1;
if (wert1 < 0 || wert1 > 255) {
JOB_STATUS = "ERROR_BYTE1";
return;
}
}
else {
JOB_STATUS = "ERROR_BYTE1";
return;
}
if (exist(BYTE2)) { // 2. Byte
wert2 = BYTE2;
if (wert2 < 0 || wert2 > 255) {
JOB_STATUS = "ERROR_BYTE2";
return;
}
}
else {
JOB_STATUS = "ERROR_BYTE2";
return;
}
if (exist(BYTE3)) { // 3. Byte
wert3 = BYTE3;
if (wert3 < 0 || wert3 > 255) {
JOB_STATUS = "ERROR_BYTE3";
return;
}
}
else {
JOB_STATUS = "ERROR_BYTE3";
return;
}
// ---------------- Kommunikation ------------------------------------
request[3] = wert1;
request[4] = wert2;
request[5] = wert3;
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_2E_10_00_PRUEFSTEMPEL_SCHREIBEN.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_F1_01_SVK_LESEN.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : SVK_LESEN
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// Prozessklassen
// SVK_ID
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 07.11.2005 gr V0.001 Erstellung
// 14.12.2005 gr V0.002 Result PROG_KM hinzu, toleranter Umgang mit Fingerprintlaenge
// 02.02.2006 gh V0.003 Ueberpruefung, ob Tabellen includiert sind, integriert
// 02.02.2006 gh V0.003 Include-Name wie Tabellen-Name
// 30.03.2006 gh V0.004 PROZESSKLASSE_WERT und VERSION: Berechnung korrigiert
// 27.03.2007 gh V0.005 neues Result "PROG_TEST", Anforderer: Richard Kolbeck (f<>r LDM)
// 19.10.2007 rd V0.006 Result SGBM_ID neu dazu
// *******************************************************************
// UDS_22_F1_01_SVK_LESEN.B2S @(#)@ V0.006 @(#)@
// *******************************************************************
job ( name : SVK_LESEN;
comment : Informationen zur Steuergeraete-Verbau-Kennung;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $F1xx Sub-Parameter fuer SVK;
comment : UDS : $F101 SVK_AKTUELL (Default);
comment : Modus: Default;
argument : SVK;
type : string;
comment : table SVK_ID BEZEICHNUNG WERT;
comment : default SVK_AKTUELL;
result : PROG_TEST;
type : int;
comment : Programmierabhaengigkeiten (ProgrammingDependenciesChecked);
comment : 1: IO : Signaturpruefung und ProgrammingDependenciesCheck erfolgreich;
comment : 2: NIO: mindestens eine SWE fehlerhaft oder ProgrammingDependenciesCheck nicht durchgefuehrt;
comment : 3: NIO: mindestens eine SWE passt nicht mit einer HWE zusammen;
comment : 4: NIO: mindestens eine SWE passt nicht mit einer anderen SWE zusammen;
comment : sonst: reserviert;
result : ANZAHL_EINHEITEN;
type : int;
comment : Anzahl der xWEn;
result : PROG_DATUM;
type : string;
comment : Programmierdatum (DD.MM.YY);
result : PROG_KM;
type : long;
comment : KM-Stand bei Programmierung (10 KM bis 655350 KM);
comment : Inkrement sind 10 KM;
comment : -1: KM-Stand wird nicht unterstuetzt;
result : PROZESSKLASSE_WERT;
type : int;
comment : table Prozessklassen WERT;
comment : dezimale Angabe der Prozessklasse;
result : PROZESSKLASSE_TEXT;
type : string;
comment : table Prozessklassen BEZEICHNUNG;
comment : Text-Angabe der Prozessklasse;
result : PROZESSKLASSE_KURZTEXT;
type : string;
comment : table Prozessklassen PROZESSKLASSE;
comment : Text-Angabe des Prozessklassenkurztextes;
result : SGBM_IDENTIFIER;
type : string;
comment : Angabe SGBM-ID der Prozessklasse;
result : VERSION;
type : string;
comment : Angabe der Version der Prozessklasse;
result : SGBM_ID;
type : string;
comment : Angabe von Prozessklasse, SGBM-Identifier, Version;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x22, 0xF1, 0x01};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// Variablen fuer Job
unsigned char temp[];
unsigned int LIAnzahl;
int index = 0;
unsigned char temp2[];
unsigned char LSIndex[];
unsigned int LIFingerprint = 13;
unsigned int LISVK=0;
unsigned int LIFingerprintIO = 1;
int datenlaenge;
char sgbmid[];
// ---------------- Ueberpruefung ob Tabellen includiert sind --------
INCLUDE_UDS_TAB_Prozessklassen_B2S_NOT_FOUND;
// ---------------- Argumente des Jobs auswerten ---------------------
if (exist(SVK)) {
dataclear(temp);
temp2 = SVK;
// Tabelle SVK_ID nach uebergebenen Wert durchsuchen
tabset("SVK_ID");
if ((tabseek("BEZEICHNUNG",temp2)) != 0)
tabget(temp, "WERT");
else { // keinen Eintrag gefunden
JOB_STATUS = "ERROR_ARGUMENT";
return; // weitere Verarbeitung abbrechen
}
request[2] = atoi(temp);
}
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (PROG_TEST)
PROG_TEST = response[4];
dataclear(temp);
datacopy(temp, response, 5, 2);
LIAnzahl = (response[5] << 8) + response[6];
if (LIAnzahl == 0) {
JOB_STATUS = "ERROR_NO_SVK";
}
else {
// L<>nge Fingerprint auswerten. Die L<>nge des Fingerprints betr<74>gt entweder 4 oder 13 Bytes.
// Information steht im 4.Byte des Fingerprints (Byte 11 in SVK).
// Ist das 7.Bit des Bytes eine 0, dann ist die L<>nge 4. Bei einer 1 betr<74>gt die L<>nge 13.
if (((response[10] >> 7) & 0x01) == 1)
LIFingerprint = 13;
else
LIFingerprint = 4;
datenlaenge = datalen(response);
// Schleife fuer die einzelnen xWEn
while (index < LIAnzahl) {
sgbmid="";
// Ueberpruefung der Datenlaenge // Fehlerabfangen, wenn kurzer Fingerprint geliefert wird, aber ein langer gemeint ist
if ((datalen(response) != (7 + LIFingerprint + (LIAnzahl * 8))) && (datalen(response) != (7 + 13 + (LIAnzahl * 8)))) {
if (ANZAHL_EINHEITEN)
ANZAHL_EINHEITEN = LIAnzahl;
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "ERROR_SVK_INCORRECT_LEN";
return;
} // Langer Fingerprint, aber Laengenangabe fuer kurzen Fingerprint angegeben
else if ((datalen(response) == (7 + 13 + (LIAnzahl * 8))) && (LIFingerprint == 4)) {
LIFingerprintIO = 0; // Fingerprint nicht IO
LIFingerprint = 13;
}
itoad(LSIndex, index+1);
// Ausgabe der Prozessklasse
if (PROZESSKLASSE_WERT || PROZESSKLASSE_TEXT || PROZESSKLASSE_KURZTEXT || SGBM_ID) {
// Abholen der Daten und Hex-String zusammenbauen
dataclear(temp2);
LISVK = response[7 + LIFingerprint + (8*index)];
if (PROZESSKLASSE_WERT)
PROZESSKLASSE_WERT = LISVK;
// Text aus Tabelle PROZESSKLASSEN holen
tabset("Prozessklassen");
tab_suche_unsigned("WERT", LISVK);
if (PROZESSKLASSE_TEXT) {
tabget(temp2, "BEZEICHNUNG");
PROZESSKLASSE_TEXT = temp2;
}
if (PROZESSKLASSE_KURZTEXT || SGBM_ID) {
tabget(temp2, "PROZESSKLASSE");
if (PROZESSKLASSE_KURZTEXT) {
PROZESSKLASSE_KURZTEXT = temp2;
}
if (SGBM_ID) {
sgbmid=temp2;
strcat(sgbmid,"-");
}
}
}
// Ausgabe des Log.-Identifier
if (SGBM_IDENTIFIER || SGBM_ID) {
dataclear(temp);
hex2ascii(temp, response, 8 + LIFingerprint + (8*index), 4); // Abholen der Daten
if (SGBM_IDENTIFIER) {
SGBM_IDENTIFIER = temp;
}
if (SGBM_ID) {
strcat(sgbmid,temp);
strcat(sgbmid,"-");
}
}
// Ausgabe der Versionsnummer
if (VERSION || SGBM_ID) {
dataclear(temp);
dataclear(temp2);
// Hauptversionsnummer
itoad(temp, response[12 + LIFingerprint + (8*index)]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp,".");
// Nebenversionsnummer
itoad(temp2, response[13 + LIFingerprint + (8*index)]);
if (strlen(temp2) == 1)
strinsert(temp2, "00", 0);
if (strlen(temp2) == 2)
strinsert(temp2, "0", 0);
strcat(temp,temp2);
strcat(temp,".");
// Patchversionsnummer
itoad(temp2, response[14 + LIFingerprint + (8*index)]);
if (strlen(temp2) == 1)
strinsert(temp2, "00", 0);
if (strlen(temp2) == 2)
strinsert(temp2, "0", 0);
strcat(temp,temp2);
// Ausgabe Version
if (VERSION)
VERSION = temp;
if (SGBM_ID) {
strcat(sgbmid,temp);
}
}
if (SGBM_ID) {
SGBM_ID=sgbmid;
}
// neuen Ergebnissatz erzeugen
new_set_of_results();
index++;
}
if (LIFingerprintIO == 1)
JOB_STATUS = "OKAY";
else
JOB_STATUS = "ERROR_SVK_INCORRECT_FINGERPRINT";
}
if (ANZAHL_EINHEITEN)
ANZAHL_EINHEITEN = LIAnzahl;
if (PROG_DATUM) {
bcd2ascii(temp, response, 9, 1);
strcat(temp, ".");
bcd2ascii(temp2, response, 8, 1);
strcat(temp, temp2);
strcat(temp, ".");
bcd2ascii(temp2, response, 7, 1);
strcat(temp, temp2);
PROG_DATUM = temp;
}
if (PROG_KM) {
if (LIFingerprint == 13) // langer Fingerprint: Byte 18 und 19 enthalten den KM-Stand
PROG_KM = ((response[18] << 8) + response[19]) * 10; // lt. Lastenheft ist das Inkrement 10
else
PROG_KM = -1;
}
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
}
// end of : #include "UDS_22_F1_01_SVK_LESEN.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_STATUS_LESEN.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : STATUS_LESEN
// -------------------------------------------------------------------
// Globale Konstanten : TA, MAX_ARGUMENT_STATUS_LESEN,
// UNCHECK_LEN_IDENTIFIER_LIST[]
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 02.12.2005 rd V0.01 Erstellung
// 13.12.2005 rd V0.02 ator durch aitor ersetzt damit auch Zahlen im
// rd V0.02 Hex-Format 0x... unterst<73>tzt werden
// rd V0.02 Fehlermeldung bei MUL=0
// 15.12.2005 rd V0.03 Spalte RES_TABELLE dazu,
// rd V0.03 f<>r mehrere Results eines DataIdentifiers
// 30.05.2006 rd V0.10 Header <20>berarbeitet
// 12.06.2006 rd V0.11 Datentyp integer und BITFIELD dazu
// 20.06.2006 rd V0.12 Fehlermeldung bei string <20>berarbeitet
// 22.06.2006 rd V0.20 Service<63>berpr<70>fung dazu
// 24.07.2006 rd V0.21 '0-n' _WERT- Results nicht erlaubt
// 27.03.2007 rd V0.60 Service<63>berpr<70>fung aktiv
// rd V0.60 Resultname beginnend mit _stat_ jetzt erlaubt
// 22.05.2007 rd V0.75 Bug Bitfeld-Maske behoben
// 04.09.2007 rd V0.80 Bug Analoger Wert unsigned long / long behoben
// 06.12.2007 rd V1.00 Freigabe
// 22.11.2010 rd V2.00 Bug unsigned integer l/h behoben
// V2.00 Bug bei Fehlerausgabe behoben
// V2.00 Einheit DATA, TEXT dazu
// V2.00 Anforderung VH-53 Waegner
// V2.00 Integration DUMMY_ bei Einheit DATA
// V2.00 Anforderung EA-410 Lorch
// V2.00 Integration Entfall L<>ngenpr<70>fung
// V2.00 Anforderung EA-410 Lorch
// V2.00 Freigabe
// *******************************************************************
// UDS_22_STATUS_LESEN.B2S @(#)@ V2.00 @(#)@
// *******************************************************************
job ( name : STATUS_LESEN;
comment : Lesen eines oder mehrerer Stati;
comment : UDS : $22 ReadDataByIdentifier;
argument : ARGUMENT_SPALTE;
type : string;
comment : 'ARG', 'ID', 'LABEL';
argument : STATUS;
type : string;
comment : Es muss mindestens ein Argument <20>bergeben werden;
comment : Es wird das zugeh<65>rige result erzeugt;
comment : table SG_Funktionen ARG ID RESULTNAME RES_TABELLE ARG_TABELLE;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Antwort von SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x22};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
unsigned char argument_name[];
unsigned char argument_spalte[];
unsigned char temp1[];
unsigned char temp2[];
unsigned int i;
unsigned int k;
unsigned int n;
unsigned int id;
unsigned int id_response;
unsigned int len;
unsigned int unsigned_long_flag;
unsigned int hex_len;
unsigned int data_flag;
unsigned int data_pos;
unsigned int data_len;
unsigned int string_flag;
unsigned int string_pos;
unsigned int string_len;
unsigned int res_table_flag;
unsigned int line_res_table;
unsigned int size_bitfield;
unsigned int size_bitfield_old;
unsigned int line_bitfield_table;
unsigned int gefunden_flag;
long value;
long value_unsigned;
long maske;
real value_real;
real real_temp1;
real real_temp2;
// ---------------- Argumente des Jobs auswerten ---------------------
if (exist(ARGUMENT_SPALTE)) {
argument_spalte = ARGUMENT_SPALTE;
strupper(argument_spalte);
if ((strcmp(argument_spalte,"ARG")!=0) &&
(strcmp(argument_spalte,"ID")!=0) &&
(strcmp(argument_spalte,"LABEL")!=0)) {
temp1="Argument ARGUMENT_SPALTE='";strcat(temp1,argument_spalte);strcat(temp1,"' not valid.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
}
else {
var_result_string("JOB_MESSAGE","Argument ARGUMENT_SPALTE missing ('ARG', 'ID', 'LABEL').");
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
if (!exist(STATUS)) {
temp1="Argument STATUS[1] missing. MAX_ARGUMENT_STATUS_LESEN='";
itoad(temp2,MAX_ARGUMENT_STATUS_LESEN);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
// ---------------- Request erzeugen ---------------------------------
set_trap_mask(0x400);
tabset("SG_Funktionen");
if (get_error(10)) {
var_result_string("JOB_MESSAGE","Table 'SG_Funktionen' not found.");
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
n=1;
i=1;
do {
if (!get_argument(argument_name,i+1)) break;
if (strcmp(argument_name,"-")==0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"' not valid.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (!tabseek(argument_spalte,argument_name)) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp2,"SERVICE");
if (strcmp(temp2,"-")!=0) {
strupper(temp2);
k=0;
gefunden_flag=FALSE;
while (temp2[k]!=0){
if (temp2[k]=='2') {
if (temp2[k+1]=='2') {
gefunden_flag=TRUE;
break;
}
}
k++;
}
if (gefunden_flag==FALSE) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"' not valid. Service '22' not found in Table 'SG_Funktionen' column 'SERVICE'='");
tabget(temp2,"SERVICE");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp2,"ID");
id = atoi(temp2);
request[n++] = id >> 8;
request[n++] = id & 0xFF;
i++;
}
while (i <= MAX_ARGUMENT_STATUS_LESEN);
if (i > MAX_ARGUMENT_STATUS_LESEN) {
if (get_argument(argument_name,i+1)) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"' too many arguments. MAX_ARGUMENT_STATUS_LESEN='");
itoad(temp2,MAX_ARGUMENT_STATUS_LESEN);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
// ---------------- Kommunikation ------------------------------------
if (_REQUEST) _REQUEST = request;
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "_RESPONSE", 2)) {
set_trap_mask(0);
return;
}
// ---------------- Response auswerten -------------------------------
n=1;
i=1;
do {
tabset("SG_Funktionen");
if (!get_argument(argument_name,i+1)) break;
tabseek(argument_spalte,argument_name);
tabget(temp2,"ID");
id = atoi(temp2);
id_response = (response[n]<<8)+response[n+1];
n=n+2;
if (datalen(response) < n) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
if (id_response != id) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Incorrect response data identifier. Expected='");
itoax(temp2,id);strerase(temp2,2,4);
strcat(temp1,temp2);strcat(temp1,"' != Response='");
itoax(temp2,id_response);strerase(temp2,2,4);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER";
set_trap_mask(0);
return;
}
res_table_flag=FALSE;
tabget(temp2,"RES_TABELLE");
if (strcmp(temp2,"-")!=0) {
tabset(temp2);
if (get_error(10)) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Result table not found='");
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
tabget(temp2,"RES_TABELLE");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
res_table_flag=TRUE;
line_res_table=0;
tabline(line_res_table);
}
do {
// L<>ngenpr<70>fung abschalten ?
// nur wenn keine Restdaten vorhanden
if (datalen(response) == n) {
// nur beim ersten Argument
if (i==1) {
// nur wenn kein zweites Argument
if (!get_argument(temp1,2+1)) {
len = datalen(UNCHECK_LEN_IDENTIFIER_LIST) / 2 ; // 1 Integer = 2 Byte
k=0;
do {
if (UNCHECK_LEN_IDENTIFIER_LIST[k] != 0) {
if (UNCHECK_LEN_IDENTIFIER_LIST[k] == id) {
// Zu wenig Daten. Restliche Results werden nicht erzeugt
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Too less data. UNCHECK_LEN_IDENTIFIER_LIST contains ID='");
itoax(temp2,id);strerase(temp2,2,4);
strcat(temp1,temp2);strcat(temp1,"'. WARNING: Remaining results are not created.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "OKAY";
set_trap_mask(0);
return;
}
}
k++;
} while (k<len);
}
}
}
tabget(temp1,"EINHEIT");
strlower(temp1);
if (strcmp(temp1,"0/1")==0) {
// Digitaler Wert
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
n=n+4;
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (datalen(response) < n) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 58) { // 63 maximal RESULTNAME + '_INFO'
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (len >= 5) {
temp2="";
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
if (strcmp(temp2,"_wert")==0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
var_result_long(temp1,value);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
if ((value!=0) && (value!=1)) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Digital value not valid='");
itoad(temp2,value);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"0-n")==0) {
// Diskreter Wert
unsigned_long_flag=FALSE;
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
value_unsigned = value;
if (strcmp(temp1,"unsigned char")!=0)
if (value & 0x80) value = value | 0xFFFFFF00;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
value_unsigned = value;
if ((strcmp(temp1,"unsigned int")!=0) && (strcmp(temp1,"unsigned integer")!=0))
if (value & 0x8000) value = value | 0xFFFF0000;
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
value_unsigned = value;
n=n+4;
if (strcmp(temp1,"unsigned long")==0) unsigned_long_flag = TRUE;
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (datalen(response) < n) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 58) { // 63 maximal RESULTNAME + '_INFO'
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_wert")==0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (unsigned_long_flag == TRUE)
var_result_unsigned_long(temp1,value);
else
var_result_long(temp1,value);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
tabget(temp2,"NAME");
if (strcmp(temp2,"-")!=0) {
tabset(temp2);
if (get_error(10)) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tab_suche_unsigned("WERT",value_unsigned);
if (get_error(10)) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table column 'WERT' not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tabget(temp2,"TEXT");
if (get_error(10)) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table column 'TEXT' not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
strerase(temp1,len,5);
strcat(temp1,"_TEXT");
var_result_string(temp1,temp2);
}
}
else {
if (strcmp(temp1,"hex")==0) {
// Hex String
unsigned_long_flag=FALSE;
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
hex_len=2;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
hex_len=4;
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
hex_len=8;
n=n+4;
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (datalen(response) < n) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 63) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_wert")!=0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
itoax(temp2,value);
strerase(temp2,0,10-hex_len);
strupper(temp2);
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
}
else {
if (strcmp(temp1,"bit")==0) {
// Bitfeld
tabget(temp1,"DATENTYP");
strlower(temp1);
if (strcmp(temp1,"bitfield")==0) {
tabget(temp2,"NAME");
tabset(temp2);
if (get_error(10)) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. bitfield table not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
size_bitfield=0;
size_bitfield_old=0;
line_bitfield_table=0;
tabline(line_bitfield_table);
do {
tabget(temp1,"EINHEIT");
strlower(temp1);
if (strcmp(temp1,"0/1")==0) {
// Digitaler Wert im Bitfeld
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
size_bitfield=1;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
size_bitfield=2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
size_bitfield=4;
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (size_bitfield_old != size_bitfield) {
if (size_bitfield_old == 0) {
size_bitfield_old = size_bitfield;
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Different bitfield size in table='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (datalen(response) < (n+size_bitfield)) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"MASKE");
maske=atoi(temp1);
if ((maske & value) == maske)
value=1;
else
value=0;
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 58) { // 63 maximal RESULTNAME + '_INFO'
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (len >= 5) {
temp2="";
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
if (strcmp(temp2,"_wert")==0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
var_result_long(temp1,value);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
}
else {
if (strcmp(temp1,"0-n")==0) {
// Diskreter Wert im Bitfeld
unsigned_long_flag=FALSE;
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
value_unsigned = value;
if (strcmp(temp1,"unsigned char")!=0)
if (value & 0x80) value = value | 0xFFFFFF00;
size_bitfield=1;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
value_unsigned = value;
if ((strcmp(temp1,"unsigned int")!=0) && (strcmp(temp1,"unsigned integer")!=0))
if (value & 0x8000) value = value | 0xFFFF0000;
size_bitfield=2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
value_unsigned = value;
size_bitfield=4;
if (strcmp(temp1,"unsigned long")==0) unsigned_long_flag = TRUE;
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (size_bitfield_old != size_bitfield) {
if (size_bitfield_old == 0) {
size_bitfield_old = size_bitfield;
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Different bitfield size in table='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (datalen(response) < (n+size_bitfield)) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"MASKE");
maske=atoi(temp1);
value = maske & value;
value_unsigned = maske & value_unsigned;
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 58) { // 63 maximal RESULTNAME + '_INFO'
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_wert")==0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (unsigned_long_flag == TRUE)
var_result_unsigned_long(temp1,value);
else
var_result_long(temp1,value);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
tabget(temp2,"NAME");
if (strcmp(temp2,"-")!=0) {
tabset(temp2);
if (get_error(10)) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tab_suche_unsigned("WERT",value_unsigned);
if (get_error(10)) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table column 'WERT' not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tabget(temp2,"TEXT");
if (get_error(10)) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table column 'TEXT' not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
strerase(temp1,len,5);
strcat(temp1,"_TEXT");
var_result_string(temp1,temp2);
// wieder zur<75>ck
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
tabset(temp2);
}
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
line_bitfield_table++;
} while (tabline(line_bitfield_table));
n = n + size_bitfield;
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"data")==0) {
// Data
tabget(temp1,"DATENTYP");
strlower(temp1);
len = strlen(temp1);
temp2="?????";
strncpy(temp2,temp1,5);
if ((strcmp(temp2,"data[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,5);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
data_pos=n;
n=n+data_len;
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. Len out of range (1..255)='");
itoad(temp2,data_len);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (datalen(response) < n) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
temp2="";
if (len >= 6) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"dummy_")==0) {
// Warnung bei Dummy_
var_result_string("JOB_MESSAGE","Warning: RESULTNAME 'DUMMY_..' ignored.");
}
else {
if (len > 63) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_data")!=0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
dataclear(temp2);
datacopy(temp2,response,data_pos,data_len);
var_result_data(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
}
}
else {
if (strcmp(temp1,"text")==0) {
// Text
tabget(temp1,"DATENTYP");
strlower(temp1);
len = strlen(temp1);
temp2="???????";
strncpy(temp2,temp1,7);
if ((strcmp(temp2,"string[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,7);
string_len=atoi(temp2);
if ((string_len > 0) && (string_len < 256)) {
string_pos=n;
n=n+string_len;
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. Len out of range (1..255)='");
itoad(temp2,string_len);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"string")==0) {
k=0;
string_flag=FALSE;
while ((n+k) < datalen(response)) {
if (response[n+k]==0) {
string_flag=TRUE;
string_pos=n;
string_len=k+1;
n=n+string_len;
break;
}
k++;
}
if (string_flag==FALSE) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. String end character '0x00' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_NO_STRING_END_CHAR";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (datalen(response) < n) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 63) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_text")!=0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
dataclear(temp2);
datacopy(temp2,response,string_pos,string_len);
temp2[string_len]=0;
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
}
else {
// Analoger Wert
data_flag=FALSE;
string_flag=FALSE;
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
if (strcmp(temp1,"unsigned char")!=0)
if (value & 0x80) value = value | 0xFFFFFF00;
itor(value_real,value);
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
if ((strcmp(temp1,"unsigned int")!=0) && (strcmp(temp1,"unsigned integer")!=0))
if (value & 0x8000) value = value | 0xFFFF0000;
itor(value_real,value);
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
itor(value_real,value);
if (strcmp(temp1,"unsigned long")==0) {
if (value & 0x80000000) {
ator(real_temp1,"4294967296");
realadd(value_real,real_temp1);
}
}
n=n+4;
}
else {
if ((strcmp(temp1,"float")==0) ||
(strcmp(temp1,"intel float")==0)) {
data_to_real(value_real,response,n,0,0);
n=n+4;
}
else {
if (strcmp(temp1,"motorola float")==0) {
data_to_real(value_real,response,n,0,1);
n=n+4;
}
else {
if ((strcmp(temp1,"double")==0) ||
(strcmp(temp1,"intel double")==0)) {
data_to_real(value_real,response,n,1,0);
n=n+8;
}
else {
if (strcmp(temp1,"motorola double")==0) {
data_to_real(value_real,response,n,1,1);
n=n+8;
}
else {
len = strlen(temp1);
temp2="?????";
strncpy(temp2,temp1,5);
if ((strcmp(temp2,"data[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,5);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
data_flag=TRUE;
data_pos=n;
n=n+data_len;
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. Len out of range (1..255)='");
itoad(temp2,data_len);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
len = strlen(temp1);
temp2="???????";
strncpy(temp2,temp1,7);
if ((strcmp(temp2,"string[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,7);
string_len=atoi(temp2);
if ((string_len > 0) && (string_len < 256)) {
string_flag=TRUE;
string_pos=n;
n=n+string_len;
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. Len out of range (1..255)='");
itoad(temp2,string_len);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"string")==0) {
k=0;
string_flag=FALSE;
while ((n+k) < datalen(response)) {
if (response[n+k]==0) {
string_flag=TRUE;
string_pos=n;
string_len=k+1;
n=n+string_len;
break;
}
k++;
}
if (string_flag==FALSE) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. String end character '0x00' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_NO_STRING_END_CHAR";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
} // else string
} // else string[
} // else data[
} // else motorola double
} // else intel double
} // else motorola float
} // else intel float
} // else long
} // else int
} // else char
if (datalen(response) < n) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 63) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_wert")!=0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (data_flag==TRUE) {
dataclear(temp2);
datacopy(temp2,response,data_pos,data_len);
var_result_long(temp1,0);
strerase(temp1,len-5,5);
strcat(temp1,"_DATA");
var_result_data(temp1,temp2);
}
else {
if (string_flag==TRUE) {
dataclear(temp2);
datacopy(temp2,response,string_pos,string_len);
temp2[string_len]=0;
var_result_long(temp1,0);
strerase(temp1,len-5,5);
strcat(temp1,"_TEXT");
var_result_string(temp1,temp2);
}
else {
tabget(temp2,"MUL");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
ator(real_temp2,"0");
if (realcomp(real_temp1,"==",real_temp2))
{
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Multiplication with Zero.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
realmul(value_real,real_temp1);
}
tabget(temp2,"DIV");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
ator(real_temp2,"0");
if (realcomp(real_temp1,"==",real_temp2))
{
temp1="Argument STATUS[";
itoad(temp2,i);
strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);strcat(temp1,"'. Division by Zero.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
realdiv(value_real,real_temp1);
}
tabget(temp2,"ADD");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
realadd(value_real,real_temp1);
}
var_result_real(temp1,value_real);
}
}
strerase(temp1,len-5,5);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
} // else Text
} // else Data
} // else Bitfeld
} // else Hex String
} // else Diskreter Wert
} // else Digitaler Wert
if (res_table_flag==TRUE) {
tabset("SG_Funktionen");
tabseek(argument_spalte,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
line_res_table++;
if (!tabline(line_res_table)) res_table_flag=FALSE;
}
} while (res_table_flag==TRUE);
i++;
}
while (i <= MAX_ARGUMENT_STATUS_LESEN);
if (datalen(response) != n) {
temp1="Too much data.";
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_MUCH_DATA";
set_trap_mask(0);
return;
}
JOB_STATUS = "OKAY";
set_trap_mask(0);
}
// end of : #include "UDS_22_STATUS_LESEN.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_2E_STEUERN.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : STEUERN
// -------------------------------------------------------------------
// Globale Konstanten : TA
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 12.12.2005 rd V0.01 Erstellung
// 30.05.2006 rd V0.10 Header <20>berarbeitet
// 12.06.2006 rd V0.11 Datentyp integer dazu
// 22.06.2006 rd V0.20 Service<63>berpr<70>fung dazu
// 24.07.2006 rd V0.21 '0-n' _WERT- Results nicht erlaubt
// 06.03.2007 rd V0.50 Bei diskretem Argument. Wenn Argument nicht
// rd V0.50 in Spalte Text gefunden wird,
// rd V0.50 dann auch in Spalte WERT suchen
// 27.03.2007 rd V0.60 Service<63>berpr<70>fung aktiv
// 06.12.2007 rd V1.00 Freigabe
// 22.11.2010 rd V2.00 Bug bei Fehlerausgabe behoben
// V2.00 Freigabe
// *******************************************************************
// UDS_2E_STEUERN.B2S @(#)@ V2.00 @(#)@
// *******************************************************************
job ( name : STEUERN;
comment : Vorgeben eines Status;
comment : UDS : $2E WriteDataByIdentifier;
argument : ARGUMENT_SPALTE;
type : string;
comment : 'ARG', 'ID', 'LABEL';
argument : STATUS;
type : string;
comment : Siehe table SG_Funktionen ARG ID LABEL ARG_TABELLE;
argument : WERT;
type : string;
comment : Es muss mindestens ein Argument <20>bergeben werden;
comment : Argumente siehe table SG_Funktionen ARG ID ARG_TABELLE;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Antwort von SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x2E};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
unsigned char argument_name[];
unsigned char argument_string[];
unsigned char temp1[];
unsigned char temp2[];
unsigned int k;
unsigned int n;
unsigned int id;
unsigned int id_response;
unsigned int len;
unsigned int anz_arg;
unsigned int found_flag;
unsigned int data_len;
unsigned int gefunden_flag;
unsigned long argument_unsigned;
long value;
real value_real;
real real_temp1;
real real_temp2;
// ---------------- Argumente des Jobs auswerten ---------------------
if (exist(ARGUMENT_SPALTE)) {
argument_string = ARGUMENT_SPALTE;
strupper(argument_string);
if ((strcmp(argument_string,"ARG")!=0) &&
(strcmp(argument_string,"ID")!=0) &&
(strcmp(argument_string,"LABEL")!=0)) {
temp1="Argument ARGUMENT_SPALTE='";strcat(temp1,argument_string);strcat(temp1,"' not valid.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
}
else {
var_result_string("JOB_MESSAGE","Argument ARGUMENT_SPALTE missing ('ARG', 'ID', 'LABEL').");
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
if (!exist(STATUS)) {
temp1="Argument STATUS missing.";
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
// ---------------- Request erzeugen ---------------------------------
set_trap_mask(0x400);
tabset("SG_Funktionen");
if (get_error(10)) {
var_result_string("JOB_MESSAGE","Table 'SG_Funktionen' not found.");
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
argument_name=STATUS;
if (strcmp(argument_name,"-")==0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"' not valid.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (!tabseek(argument_string,argument_name)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp2,"SERVICE");
if (strcmp(temp2,"-")!=0) {
strupper(temp2);
k=0;
gefunden_flag=FALSE;
while (temp2[k]!=0){
if (temp2[k]=='2') {
if (temp2[k+1]=='E') {
gefunden_flag=TRUE;
break;
}
}
k++;
}
if (gefunden_flag==FALSE) {
temp1="Argument STATUS='";strcat(temp1,argument_name);
strcat(temp1,"' not valid. Service '2E' not found in Table 'SG_Funktionen' column 'SERVICE'='");
tabget(temp2,"SERVICE");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
n=1;
tabget(temp2,"ID");
id = atoi(temp2);
request[n++] = id >> 8;
request[n++] = id & 0xFF;
tabget(argument_string,"ARG_TABELLE");
if (strcmp(argument_string,"-")==0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. ARG_TABELLE='-' not valid.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tabset(argument_string);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Argument table not found='");
strcat(temp1,argument_string);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (WERT); // damit die Compilerwarnung entf<74>llt
anz_arg=0;
while (tabline(anz_arg)) {
if (!get_argument(argument_name,anz_arg+3)) {
tabget(temp1,"DATENTYP");
strlower(temp1);
if (strcmp(temp1,"string")!=0) { // Leerstring erlauben
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);
strcat(temp1,"] missing. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"EINHEIT");
strlower(temp1);
if (strcmp(temp1,"0/1")==0) {
// Digitaler Wert
aitor(value_real,argument_name);
value=atoi(argument_name);
if ((strcmp(argument_name,"0")!=0) && (strcmp(argument_name,"1")!=0)) {
temp1="Argument WERT[";
itoad(temp2,anz_arg+1);
strcat(temp1,temp2);strcat(temp1,"] Digital value not valid='");
strcat(temp1,argument_name);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp1,"MIN");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' < MIN='");tabget(temp2,"MIN");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"MAX");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' > MAX='");tabget(temp2,"MAX");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
request[n] = value;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP not valid='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
}
else {
if (strcmp(temp1,"0-n")==0) {
// Diskreter Wert
tabget(temp2,"NAME");
if (strcmp(temp2,"-")==0) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. NAME not valid='");tabget(temp2,"NAME");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tabset(temp2);
if (get_error(10)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete value table not found='");
tabget(temp2,"NAME");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
found_flag=tabseek("TEXT",argument_name);
if (get_error(10)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete value table='");
tabget(temp2,"NAME");strcat(temp1,temp2);
strcat(temp1,"'. Column 'TEXT' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (found_flag!=TRUE) {
// Wenn nicht in Spalte Text gefunden, dann auch in Spalte Wert als Zahl suchen
if (is_hex_string(argument_name) || is_unsigned_string(argument_name)) {
argument_unsigned = atoi(argument_name);
found_flag=tab_suche_unsigned("WERT",argument_unsigned);
if (get_error(10)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete value table='");
tabget(temp2,"NAME");strcat(temp1,temp2);
strcat(temp1,"'. Column 'WERT' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (found_flag!=TRUE) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete table='");
tabget(temp2,"NAME");strcat(temp1,temp2);
strcat(temp1,"'. Argument not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp1,"WERT");
aitor(value_real,temp1);
value=atoi(temp1);
if (get_error(10)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete value table='");
tabget(temp2,"NAME");strcat(temp1,temp2);
strcat(temp1,"'. Column 'WERT' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
// wieder zur<75>ck zur Tabelle
tabset(argument_string);
tabline(anz_arg);
tabget(temp1,"MIN");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' < MIN='");tabget(temp2,"MIN");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"MAX");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' > MAX='");tabget(temp2,"MAX");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
request[n] = value;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP not valid='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
}
else {
if (strcmp(temp1,"hex")==0) {
// Hex String
aitor(value_real,argument_name);
value=atoi(argument_name);
tabget(temp1,"MIN");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' < MIN='");tabget(temp2,"MIN");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"MAX");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' > MAX='");tabget(temp2,"MAX");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
request[n] = value;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP not valid='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
}
else {
// Analoger Wert
tabget(temp1,"DATENTYP");
strlower(temp1);
len = strlen(temp1);
temp2="?????";
strncpy(temp2,temp1,5);
if ((strcmp(temp2,"data[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,5);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
len=strlen(argument_name);
if (len == 2*data_len) {
ascii2hex(request,argument_name,n);
n=n+data_len;
if (datalen(request) != n) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Invalid characters in argument. Valid characters=0123456789ABCDEF.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
if (len < 2*data_len)
strcat(temp1,"'. Too less data. Expected argument string len='");
else
strcat(temp1,"'. Too much data. Expected argument string len='");
itoad(temp2,2*data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Len out of range (1..255)='");itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
len = strlen(temp1);
temp2="???????";
strncpy(temp2,temp1,7);
if ((strcmp(temp2,"string[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,7);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
len=strlen(argument_name);
if (len == data_len) {
datacat(request,argument_name);
dataerase(request,n+data_len,1); // String end character '0x00' entfernen
n=n+data_len;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
if (len < data_len)
strcat(temp1,"'. Too less data. Expected argument string len='");
else
strcat(temp1,"'. Too much data. Expected argument string len='");
itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Len out of range (1..255)='");itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"string")==0) {
data_len=strlen(argument_name)+1; // String end character '0x00'
if ((data_len > 0) && (data_len < 256)) {
datacat(request,argument_name);
n=n+data_len;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Len out of range (1..255)='");itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
else {
aitor(value_real,argument_name);
tabget(temp1,"MIN");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' < MIN='");tabget(temp2,"MIN");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"MAX");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' > MAX='");tabget(temp2,"MAX");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp2,"MUL");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
ator(real_temp2,"0");
if (realcomp(real_temp1,"==",real_temp2))
{
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Multiplication with Zero.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
realmul(value_real,real_temp1);
}
tabget(temp2,"DIV");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
ator(real_temp2,"0");
if (realcomp(real_temp1,"==",real_temp2))
{
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Division by Zero.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
realdiv(value_real,real_temp1);
}
tabget(temp2,"ADD");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
realadd(value_real,real_temp1);
}
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value=rtoi_round(value_real);
if (value < -128) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' < -128.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (value > 127) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' > 127.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
request[n] = value;
n++;
}
else {
if (strcmp(temp1,"unsigned char")==0) {
value=rtoi_round(value_real);
if (value < 0) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' < 0.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (value > 255) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' > 255.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
request[n] = value;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
value=rtoi_round(value_real);
if (value < -32768) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' < -32768.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (value > 32767) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' > 32767.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0)) {
value=rtoi_round(value_real);
if (value < 0) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' < 0.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (value > 65535) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' > 65535.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"signed long")==0)) {
ator(real_temp1,"-2147483648");
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' < -2147483648.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"2147483647");
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' > 2147483647.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
value=rtoi_round(value_real);
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
if (strcmp(temp1,"unsigned long")==0) {
ator(real_temp1,"0");
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' < 0.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"4294967295");
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' > 4294967295.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
value=rtoi_round(value_real);
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
if ((strcmp(temp1,"float")==0) ||
(strcmp(temp1,"intel float")==0)) {
ator(real_temp1,"-3.4028234663852884E+038");
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' < -3.4028234663852884E+038");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"3.4028234663852884E+038");
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' > 3.4028234663852884E+038");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"0");
if (realcomp(value_real,">",real_temp1)) {
ator(real_temp1,"1.1754943508222877E-038");
if (realcomp(value_real,"<",real_temp1)) {
value_real=real_temp1;
}
}
ator(real_temp1,"0");
if (realcomp(value_real,"<",real_temp1)) {
ator(real_temp1,"-1.1754943508222877E-038");
if (realcomp(value_real,">",real_temp1)) {
value_real=real_temp1;
}
}
real_to_data(request,value_real,n,0,0);
n=n+4;
}
else {
if (strcmp(temp1,"motorola float")==0) {
ator(real_temp1,"-3.4028234663852884E+038");
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' < -3.4028234663852884E+038");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"3.4028234663852884E+038");
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' > 3.4028234663852884E+038");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"0");
if (realcomp(value_real,">",real_temp1)) {
ator(real_temp1,"1.1754943508222877E-038");
if (realcomp(value_real,"<",real_temp1)) {
value_real=real_temp1;
}
}
ator(real_temp1,"0");
if (realcomp(value_real,"<",real_temp1)) {
ator(real_temp1,"-1.1754943508222877E-038");
if (realcomp(value_real,">",real_temp1)) {
value_real=real_temp1;
}
}
real_to_data(request,value_real,n,0,1);
n=n+4;
}
else {
if ((strcmp(temp1,"double")==0) ||
(strcmp(temp1,"intel double")==0)) {
real_to_data(request,value_real,n,1,0);
n=n+8;
}
else {
if (strcmp(temp1,"motorola double")==0) {
real_to_data(request,value_real,n,1,1);
n=n+8;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP not valid='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
} // else Analog motorola double
} // else Analog (intel) double
} // else Analog motorola float
} // else Analog (intel) float
} // else Analog unsigned long
} // else Analog (signed) long
} // else Analog unsigned int
} // else Analog (signed) int
} // else Analog unsigned char
} // else Analog (signed) char
} // else Analog string
} // else Analog string[x]
} // else Analog data[x]
} // else Hex String
} // else Diskreter Wert
} // else Digitaler Wert
anz_arg++;
}
if (get_argument(temp1,anz_arg+3)) {
temp1="Argument WERT[";
itoad(temp2,anz_arg+1);
strcat(temp1,temp2);strcat(temp1,"]='");
get_argument(temp2,anz_arg+3);
strcat(temp1,temp2);strcat(temp1,"'. Too many arguments. Number of arguments='");
itoad(temp2,anz_arg);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
// ---------------- Kommunikation ------------------------------------
if (_REQUEST) _REQUEST = request;
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "_RESPONSE", 2)) {
set_trap_mask(0);
return;
}
// ---------------- Response auswerten -------------------------------
if (datalen(response) < 3) {
argument_name=STATUS;
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
if (datalen(response) > 3) {
argument_name=STATUS;
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too much data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_MUCH_DATA";
set_trap_mask(0);
return;
}
id_response = (response[1]<<8)+response[2];
if (id_response != id) {
argument_name=STATUS;
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Incorrect response data identifier. Expected='");
itoax(temp2,id);strerase(temp2,2,4);
strcat(temp1,temp2);strcat(temp1,"' != Response='");
itoax(temp2,id_response);strerase(temp2,2,4);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER";
set_trap_mask(0);
return;
}
JOB_STATUS = "OKAY";
set_trap_mask(0);
}
// end of : #include "UDS_2E_STEUERN.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_F1_8C_SERIENNUMMER_LESEN.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : SERIENNUMMER_LESEN
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 18.11.2005 gr V0.001 Erstellung
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Job-Name)
// 23.03.2006 gh V0.003 Interpretation ge<67>ndert von ASCII nach HEX
// 22.06.2006 gh V0.004 Anpassung an LH SAP 10000970
// *******************************************************************
// UDS_22_F1_8C_SERIENNUMMER_LESEN.B2S @(#)@ V0.004 @(#)@
// *******************************************************************
job ( name : SERIENNUMMER_LESEN;
comment : Seriennummer des Steuergeraets;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $F18C Sub-Parameter ECUSerialNumber;
comment : Modus: Default;
result : SERIENNUMMER;
type : string;
comment : Seriennummer des Steuergeraets;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x22, 0xF1, 0x8C};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
unsigned char temp[];
int index;
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
/*
if (SERIENNUMMER) {
dataclear(temp);
// datacopy(temp, response, 3, 10); manche Zeichen nicht darstellbar !
hex2ascii(temp, response, 3, 10);
strinsert(temp, "0x", 0);
SERIENNUMMER = temp;
}
*/
JOB_STATUS = "OKAY"; // Hier weiter vorne notwendig !
if (SERIENNUMMER) {
temp = "**********";
index = 0;
while (index < 10) {
if ((response[index+3] >= 0x00) && (response[index+3] <= 0x09)) {
temp[index] = 0x30 + response[index+3];
}
else {
if ((response[index+3] >= 0x30) && (response[index+3] <= 0x39)) {
temp[index] = response[index+3];
}
else {
JOB_STATUS = "ERROR_ECU_RESPONSE_INCORRECT_SERIAL_NUMBER_FORMAT";
}
}
index++;
}
SERIENNUMMER = temp;
}
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
}
// end of : #include "UDS_22_F1_8C_SERIENNUMMER_LESEN.B2S"
// optionale Standard Diagnose-Jobs
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_2F_STEUERN_IO.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : STEUERN_IO
// -------------------------------------------------------------------
// Globale Konstanten : TA
// UNCHECK_LEN_IDENTIFIER_LIST[]
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 30.05.2006 rd V0.01 Erstellung
// 31.05.2006 rd V0.10 Header <20>berarbeitet
// 12.06.2006 rd V0.11 Datentyp integer dazu
// 20.06.2006 rd V0.12 Datentyp BITFIELD dazu
// V0.12 Fehlermeldung bei string <20>berarbeitet
// 22.06.2006 rd V0.20 Service<63>berpr<70>fung dazu
// 24.07.2006 rd V0.21 '0-n' _WERT- Results nicht erlaubt
// 04.09.2006 rd V0.22 Erstes Result f<>hrt zu keiner Fehlermeldung
// V0.22 wenn RESULTNAME und DATENTYP und EINHEIT == '-'
// 06.03.2007 rd V0.50 Steuerparameter optional
// rd V0.50 Bei diskretem Argument. Wenn Argument nicht
// rd V0.50 in Spalte Text gefunden wird,
// rd V0.50 dann auch in Spalte WERT suchen
// 27.03.2007 rd V0.60 Service<63>berpr<70>fung aktiv
// rd V0.60 Resultname beginnend mit _stat_ jetzt erlaubt
// 09.05.2007 rd V0.70 Mindestl<74>nge response bug behoben
// 22.05.2007 rd V0.75 Bug Bitfeld-Maske behoben
// 04.09.2007 rd V0.80 Bug Analoger Wert unsigned long / long behoben
// 06.12.2007 rd V1.00 Freigabe
// 22.11.2010 rd V2.00 Bug unsigned integer l/h behoben
// V2.00 Bug default-argument mit string behoben
// V2.00 Bug bei Fehlerausgabe behoben
// V2.00 Einheit DATA, TEXT dazu
// V2.00 Anforderung VH-53 Waegner
// V2.00 Integration DUMMY_ bei Einheit DATA
// V2.00 Anforderung EA-410 Lorch
// V2.00 Integration Entfall L<>ngenpr<70>fung
// V2.00 Anforderung EA-410 Lorch
// V2.00 Freigabe
// *******************************************************************
// UDS_2F_STEUERN_IO.B2S @(#)@ V2.00 @(#)@
// *******************************************************************
job ( name : STEUERN_IO;
comment : Vorgeben eines Status;
comment : UDS : $2F InputOutputControlByIdentifier;
argument : ARGUMENT_SPALTE;
type : string;
comment : 'ARG', 'ID', 'LABEL';
argument : STATUS;
type : string;
comment : Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE;
argument : STEUERPARAMETER;
type : string;
comment : 'RCTECU' = returnControlToECU;
comment : 'RTD' = resetToDefault;
comment : 'FCS' = freezeCurrentState;
comment : 'STA' = shortTermAdjustment;
comment : optionales Argument;
comment : Wenn nicht angegeben, dann kein InputOutputControlParameter im Request;
argument : WERT;
type : string;
comment : Argumente siehe table SG_Funktionen ARG_TABELLE;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Antwort von SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x2F};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
unsigned char argument_name[];
unsigned char argument_string[];
unsigned char temp1[];
unsigned char temp2[];
unsigned char control_parameter;
unsigned char control_parameter_response;
unsigned int k;
unsigned int n;
unsigned int id;
unsigned int id_response;
unsigned int len;
unsigned int anz_arg;
unsigned int found_flag;
unsigned int defaultargument_flag;
unsigned int data_len;
unsigned int unsigned_long_flag;
unsigned int data_flag;
unsigned int data_pos;
unsigned int string_flag;
unsigned int string_pos;
unsigned int string_len;
unsigned int hex_len;
unsigned int res_table_flag;
unsigned int line_res_table;
unsigned int first_result_flag;
unsigned int size_bitfield;
unsigned int size_bitfield_old;
unsigned int line_bitfield_table;
unsigned int gefunden_flag;
unsigned long enable_flag;
unsigned long enable_mask;
unsigned long argument_unsigned;
long value;
long value_unsigned;
long maske;
real value_real;
real real_temp1;
real real_temp2;
// ---------------- Argumente des Jobs auswerten ---------------------
if (exist(ARGUMENT_SPALTE)) {
argument_string = ARGUMENT_SPALTE;
strupper(argument_string);
if ((strcmp(argument_string,"ARG")!=0) &&
(strcmp(argument_string,"ID")!=0) &&
(strcmp(argument_string,"LABEL")!=0)) {
temp1="Argument ARGUMENT_SPALTE='";strcat(temp1,argument_string);strcat(temp1,"' not valid.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
}
else {
var_result_string("JOB_MESSAGE","Argument ARGUMENT_SPALTE missing ('ARG', 'ID', 'LABEL').");
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
if (!exist(STATUS)) {
temp1="Argument STATUS missing.";
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
// ---------------- Request erzeugen ---------------------------------
set_trap_mask(0x400);
tabset("SG_Funktionen");
if (get_error(10)) {
var_result_string("JOB_MESSAGE","Table 'SG_Funktionen' not found.");
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
argument_name=STATUS;
if (strcmp(argument_name,"-")==0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"' not valid.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (!tabseek(argument_string,argument_name)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp2,"SERVICE");
if (strcmp(temp2,"-")!=0) {
strupper(temp2);
k=0;
gefunden_flag=FALSE;
while (temp2[k]!=0){
if (temp2[k]=='2') {
if (temp2[k+1]=='F') {
gefunden_flag=TRUE;
break;
}
}
k++;
}
if (gefunden_flag==FALSE) {
temp1="Argument STATUS='";strcat(temp1,argument_name);
strcat(temp1,"' not valid. Service '2F' not found in Table 'SG_Funktionen' column 'SERVICE'='");
tabget(temp2,"SERVICE");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
n=1;
tabget(temp2,"ID");
id = atoi(temp2);
request[n++] = id >> 8;
request[n++] = id & 0xFF;
if (exist(STEUERPARAMETER)) {
temp2 = STEUERPARAMETER;
strupper(temp2);
if ((strcmp(temp2,"RCTECU")!=0) &&
(strcmp(temp2,"RTD")!=0) &&
(strcmp(temp2,"FCS")!=0) &&
(strcmp(temp2,"STA")!=0)) {
temp1="Argument STEUERPARAMETER='";strcat(temp1,temp2);strcat(temp1,"' not valid.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
else {
if (strcmp(temp2,"RCTECU")==0) control_parameter = 0x00;
if (strcmp(temp2,"RTD") ==0) control_parameter = 0x01;
if (strcmp(temp2,"FCS") ==0) control_parameter = 0x02;
if (strcmp(temp2,"STA") ==0) control_parameter = 0x03;
request[n++] = control_parameter;
}
}
else {
// optionales Argument
control_parameter = 0xFF;
// var_result_string("JOB_MESSAGE","Argument STEUERPARAMETER missing ('RCTECU', 'RTD', 'FCS', 'STA').");
// JOB_STATUS = "ERROR_ARGUMENT";
// return;
}
tabget(argument_string,"ARG_TABELLE");
if (strcmp(argument_string,"-")!=0) {
tabset(argument_string);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Argument table not found='");
strcat(temp1,argument_string);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (tabline(32)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Argument table ='");
strcat(temp1,argument_string);strcat(temp1,"'. Too many arguments. Limit is 32.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (WERT); // damit die Compilerwarnung entf<74>llt
anz_arg=0;
if ((control_parameter == 0x03) || (control_parameter == 0xFF)) {
// Argumente nur bei ShortTermAdjustment oder wenn kein Steuerparameter
enable_flag=0x80000000;
enable_mask=0;
while (tabline(anz_arg)) {
defaultargument_flag = FALSE;
if (!get_argument(argument_name,anz_arg+4)) {
if (!tabline(1)) {
// Pflicht bei nur einem Argument
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);
strcat(temp1,"] missing. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
else {
defaultargument_flag = TRUE;
}
}
if (defaultargument_flag == TRUE) {
tabline(anz_arg);
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
n=n+4;
}
else {
len = strlen(temp1);
temp2="?????";
strncpy(temp2,temp1,5);
if ((strcmp(temp2,"data[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,5);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
n=n+data_len;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Len out of range (1..255)='");itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
len = strlen(temp1);
temp2="???????";
strncpy(temp2,temp1,7);
if ((strcmp(temp2,"string[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,7);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
n=n+data_len;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Len out of range (1..255)='");itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"string")==0) {
n++;
}
else {
if ((strcmp(temp1,"float")==0) ||
(strcmp(temp1,"intel float")==0) ||
(strcmp(temp1,"motorola float")==0)) {
n=n+4;
}
else {
if ((strcmp(temp1,"double")==0) ||
(strcmp(temp1,"intel double")==0) ||
(strcmp(temp1,"motorola double")==0)) {
n=n+8;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP not valid='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
} // else double
} // else float
} // else string
} // else string[x]
} // else data[x]
} // else long
} // else int
} // else char
} // if defaultargument_flag
else {
enable_mask = enable_mask | enable_flag;
tabget(temp1,"EINHEIT");
strlower(temp1);
if (strcmp(temp1,"0/1")==0) {
// Digitaler Wert
aitor(value_real,argument_name);
value=atoi(argument_name);
if ((strcmp(argument_name,"0")!=0) && (strcmp(argument_name,"1")!=0)) {
temp1="Argument WERT[";
itoad(temp2,anz_arg+1);
strcat(temp1,temp2);strcat(temp1,"] Digital value not valid='");
strcat(temp1,argument_name);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp1,"MIN");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' < MIN='");tabget(temp2,"MIN");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"MAX");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' > MAX='");tabget(temp2,"MAX");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
request[n] = value;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP not valid='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
}
else {
if (strcmp(temp1,"0-n")==0) {
// Diskreter Wert
tabget(temp2,"NAME");
if (strcmp(temp2,"-")==0) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. NAME not valid='");tabget(temp2,"NAME");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tabset(temp2);
if (get_error(10)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete value table not found='");
tabget(temp2,"NAME");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
found_flag=tabseek("TEXT",argument_name);
if (get_error(10)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete value table='");
tabget(temp2,"NAME");strcat(temp1,temp2);
strcat(temp1,"'. Column 'TEXT' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (found_flag!=TRUE) {
// Wenn nicht in Spalte Text gefunden, dann auch in Spalte Wert als Zahl suchen
if (is_hex_string(argument_name) || is_unsigned_string(argument_name)) {
argument_unsigned = atoi(argument_name);
found_flag=tab_suche_unsigned("WERT",argument_unsigned);
if (get_error(10)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete value table='");
tabget(temp2,"NAME");strcat(temp1,temp2);
strcat(temp1,"'. Column 'WERT' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (found_flag!=TRUE) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete table='");
tabget(temp2,"NAME");strcat(temp1,temp2);
strcat(temp1,"'. Argument not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp1,"WERT");
aitor(value_real,temp1);
value=atoi(temp1);
if (get_error(10)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete value table='");
tabget(temp2,"NAME");strcat(temp1,temp2);
strcat(temp1,"'. Column 'WERT' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
// wieder zur<75>ck zur Tabelle
tabset(argument_string);
tabline(anz_arg);
tabget(temp1,"MIN");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' < MIN='");tabget(temp2,"MIN");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"MAX");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' > MAX='");tabget(temp2,"MAX");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
request[n] = value;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP not valid='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
}
else {
if (strcmp(temp1,"hex")==0) {
// Hex String
aitor(value_real,argument_name);
value=atoi(argument_name);
tabget(temp1,"MIN");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' < MIN='");tabget(temp2,"MIN");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"MAX");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' > MAX='");tabget(temp2,"MAX");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
request[n] = value;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP not valid='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
}
else {
// Analoger Wert
tabget(temp1,"DATENTYP");
strlower(temp1);
len = strlen(temp1);
temp2="?????";
strncpy(temp2,temp1,5);
if ((strcmp(temp2,"data[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,5);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
len=strlen(argument_name);
if (len == 2*data_len) {
ascii2hex(request,argument_name,n);
n=n+data_len;
if (datalen(request) != n) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Invalid characters in argument. Valid characters=0123456789ABCDEF.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
if (len < 2*data_len)
strcat(temp1,"'. Too less data. Expected argument string len='");
else
strcat(temp1,"'. Too much data. Expected argument string len='");
itoad(temp2,2*data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Len out of range (1..255)='");itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
len = strlen(temp1);
temp2="???????";
strncpy(temp2,temp1,7);
if ((strcmp(temp2,"string[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,7);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
len=strlen(argument_name);
if (len == data_len) {
request[n-1] = request[n-1]; // request L<>nge auf n setzen ! default-Werte <20>ndern nur n
datacat(request,argument_name); // String anh<6E>ngen
dataerase(request,n+data_len,1); // String end character '0x00' entfernen
n=n+data_len;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
if (len < data_len)
strcat(temp1,"'. Too less data. Expected argument string len='");
else
strcat(temp1,"'. Too much data. Expected argument string len='");
itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Len out of range (1..255)='");itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"string")==0) {
data_len=strlen(argument_name)+1; // String end character '0x00'
if ((data_len > 0) && (data_len < 256)) {
request[n-1] = request[n-1]; // request L<>nge auf n setzen ! default-Werte <20>ndern nur n
datacat(request,argument_name); // String anh<6E>ngen
n=n+data_len;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Len out of range (1..255)='");itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
else {
aitor(value_real,argument_name);
tabget(temp1,"MIN");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' < MIN='");tabget(temp2,"MIN");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"MAX");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' > MAX='");tabget(temp2,"MAX");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp2,"MUL");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
ator(real_temp2,"0");
if (realcomp(real_temp1,"==",real_temp2))
{
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Multiplication with Zero.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
realmul(value_real,real_temp1);
}
tabget(temp2,"DIV");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
ator(real_temp2,"0");
if (realcomp(real_temp1,"==",real_temp2))
{
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Division by Zero.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
realdiv(value_real,real_temp1);
}
tabget(temp2,"ADD");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
realadd(value_real,real_temp1);
}
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value=rtoi_round(value_real);
if (value < -128) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' < -128.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (value > 127) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' > 127.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
request[n] = value;
n++;
}
else {
if (strcmp(temp1,"unsigned char")==0) {
value=rtoi_round(value_real);
if (value < 0) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' < 0.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (value > 255) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' > 255.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
request[n] = value;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
value=rtoi_round(value_real);
if (value < -32768) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' < -32768.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (value > 32767) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' > 32767.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0)) {
value=rtoi_round(value_real);
if (value < 0) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' < 0.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (value > 65535) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' > 65535.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"signed long")==0)) {
ator(real_temp1,"-2147483648");
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' < -2147483648.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"2147483647");
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' > 2147483647.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
value=rtoi_round(value_real);
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
if (strcmp(temp1,"unsigned long")==0) {
ator(real_temp1,"0");
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' < 0.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"4294967295");
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' > 4294967295.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
value=rtoi_round(value_real);
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
if ((strcmp(temp1,"float")==0) ||
(strcmp(temp1,"intel float")==0)) {
ator(real_temp1,"-3.4028234663852884E+038");
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' < -3.4028234663852884E+038");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"3.4028234663852884E+038");
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' > 3.4028234663852884E+038");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"0");
if (realcomp(value_real,">",real_temp1)) {
ator(real_temp1,"1.1754943508222877E-038");
if (realcomp(value_real,"<",real_temp1)) {
value_real=real_temp1;
}
}
ator(real_temp1,"0");
if (realcomp(value_real,"<",real_temp1)) {
ator(real_temp1,"-1.1754943508222877E-038");
if (realcomp(value_real,">",real_temp1)) {
value_real=real_temp1;
}
}
real_to_data(request,value_real,n,0,0);
n=n+4;
}
else {
if (strcmp(temp1,"motorola float")==0) {
ator(real_temp1,"-3.4028234663852884E+038");
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' < -3.4028234663852884E+038");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"3.4028234663852884E+038");
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' > 3.4028234663852884E+038");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"0");
if (realcomp(value_real,">",real_temp1)) {
ator(real_temp1,"1.1754943508222877E-038");
if (realcomp(value_real,"<",real_temp1)) {
value_real=real_temp1;
}
}
ator(real_temp1,"0");
if (realcomp(value_real,"<",real_temp1)) {
ator(real_temp1,"-1.1754943508222877E-038");
if (realcomp(value_real,">",real_temp1)) {
value_real=real_temp1;
}
}
real_to_data(request,value_real,n,0,1);
n=n+4;
}
else {
if ((strcmp(temp1,"double")==0) ||
(strcmp(temp1,"intel double")==0)) {
real_to_data(request,value_real,n,1,0);
n=n+8;
}
else {
if (strcmp(temp1,"motorola double")==0) {
real_to_data(request,value_real,n,1,1);
n=n+8;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP not valid='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
} // else Analog motorola double
} // else Analog (intel) double
} // else Analog motorola float
} // else Analog (intel) float
} // else Analog unsigned long
} // else Analog (signed) long
} // else Analog unsigned int
} // else Analog (signed) int
} // else Analog unsigned char
} // else Analog (signed) char
} // else Analog string
} // else Analog string[x]
} // else Analog data[x]
} // else Hex String
} // else Diskreter Wert
} // else Digitaler Wert
} // else defaultargument_flag
anz_arg++;
enable_flag = enable_flag >> 1 ;
}
} // if control_parameter==0x03 || control_parameter==0xFF
if (get_argument(temp1,anz_arg+4)) {
temp1="Argument WERT[";
itoad(temp2,anz_arg+1);
strcat(temp1,temp2);strcat(temp1,"]='");
get_argument(temp2,anz_arg+4);
strcat(temp1,temp2);strcat(temp1,"'. Too many arguments. Number of arguments='");
itoad(temp2,anz_arg);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if ((control_parameter != 0x03) && (control_parameter != 0xFF)) enable_mask=0xFFFFFFFF;
// EnableMask setzen bei mehr als einem Argument
tabset(argument_string);
if (tabline(1)) {
request[n++] = enable_mask>>24; // mehr als 1 Argument
if (tabline(8)) {
request[n++] = enable_mask>>16; // mehr als 8 Argumente
if (tabline(16)) {
request[n++] = enable_mask>>8; // mehr als 16 Argumente
if (tabline(24)) {
request[n++] = enable_mask; // mehr als 24 Argumente
}
}
}
}
} // if ARG_TABELLE != '-'
else {
k=0;
while (!get_argument(temp1,k+4)) {
if (k >= 31) break;
k++;
}
if (strlen(temp1) > 0) {
temp1="Argument WERT[";
itoad(temp2,k+1);
strcat(temp1,temp2);strcat(temp1,"]='");
get_argument(temp2,k+4);
strcat(temp1,temp2);strcat(temp1,"'. Too many arguments. Number of arguments='0'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
// ---------------- Kommunikation ------------------------------------
if (_REQUEST) _REQUEST = request;
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "_RESPONSE", 2)) {
set_trap_mask(0);
return;
}
// ---------------- Response auswerten -------------------------------
if (datalen(response) < 4) {
if ((datalen(response) < 3) || (control_parameter != 0xFF)) {
argument_name=STATUS;
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
}
id_response = (response[1]<<8)+response[2];
if (id_response != id) {
argument_name=STATUS;
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Incorrect response data identifier. Expected='");
itoax(temp2,id);strerase(temp2,2,4);
strcat(temp1,temp2);strcat(temp1,"' != Response='");
itoax(temp2,id_response);strerase(temp2,2,4);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER";
set_trap_mask(0);
return;
}
n=3;
if (control_parameter != 0xFF) {
control_parameter_response = response[n];
if (control_parameter_response != control_parameter) {
argument_name=STATUS;
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Incorrect response io control parameter. Expected='");
itoax(temp2,control_parameter);strerase(temp2,2,6);
strcat(temp1,temp2);strcat(temp1,"' != Response='");
itoax(temp2,control_parameter_response);strerase(temp2,2,6);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_INCORRECT_IO_CONTROL_PARAMETER";
set_trap_mask(0);
return;
}
n++;
}
tabset("SG_Funktionen");
argument_string = ARGUMENT_SPALTE;
argument_name=STATUS;
tabseek(argument_string,argument_name);
res_table_flag=FALSE;
tabget(temp2,"RES_TABELLE");
if (strcmp(temp2,"-")!=0) {
tabset(temp2);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Result table not found='");
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
res_table_flag=TRUE;
line_res_table=0;
tabline(line_res_table);
}
first_result_flag=TRUE;
do {
if (first_result_flag == TRUE) {
tabget(temp1,"RESULTNAME");
if (strcmp(temp1,"-")==0) {
tabget(temp1,"DATENTYP");
if (strcmp(temp1,"-")==0) {
tabget(temp1,"EINHEIT");
if (strcmp(temp1,"-")==0) break;
}
}
first_result_flag=FALSE;
}
// L<>ngenpr<70>fung abschalten ?
// nur wenn keine Restdaten vorhanden
if (datalen(response) == n) {
len = datalen(UNCHECK_LEN_IDENTIFIER_LIST) / 2 ; // 1 Integer = 2 Byte
k=0;
do {
if (UNCHECK_LEN_IDENTIFIER_LIST[k] != 0) {
if (UNCHECK_LEN_IDENTIFIER_LIST[k] == id) {
// Zu wenig Daten. Restliche Results werden nicht erzeugt
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data. UNCHECK_LEN_IDENTIFIER_LIST contains ID='");
itoax(temp2,id);strerase(temp2,2,4);
strcat(temp1,temp2);strcat(temp1,"'. WARNING: Remaining results are not created.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "OKAY";
set_trap_mask(0);
return;
}
}
k++;
} while (k<len);
}
tabget(temp1,"EINHEIT");
strlower(temp1);
if (strcmp(temp1,"0/1")==0) {
// Digitaler Wert
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
n=n+4;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (datalen(response) < n) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 58) { // 63 maximal RESULTNAME + '_INFO'
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (len >= 5) {
temp2="";
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
if (strcmp(temp2,"_wert")==0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
var_result_long(temp1,value);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
if ((value!=0) && (value!=1)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Digital value not valid='");
itoad(temp2,value);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"0-n")==0) {
// Diskreter Wert
unsigned_long_flag=FALSE;
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
value_unsigned = value;
if (strcmp(temp1,"unsigned char")!=0)
if (value & 0x80) value = value | 0xFFFFFF00;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
value_unsigned = value;
if ((strcmp(temp1,"unsigned int")!=0) && (strcmp(temp1,"unsigned integer")!=0))
if (value & 0x8000) value = value | 0xFFFF0000;
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
value_unsigned = value;
n=n+4;
if (strcmp(temp1,"unsigned long")==0) unsigned_long_flag = TRUE;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (datalen(response) < n) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 58) { // 63 maximal RESULTNAME + '_INFO'
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_wert")==0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (unsigned_long_flag == TRUE)
var_result_unsigned_long(temp1,value);
else
var_result_long(temp1,value);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
tabget(temp2,"NAME");
if (strcmp(temp2,"-")!=0) {
tabset(temp2);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tab_suche_unsigned("WERT",value_unsigned);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table column 'WERT' not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tabget(temp2,"TEXT");
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table column 'TEXT' not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
strerase(temp1,len,5);
strcat(temp1,"_TEXT");
var_result_string(temp1,temp2);
}
}
else {
if (strcmp(temp1,"hex")==0) {
// Hex String
unsigned_long_flag=FALSE;
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
hex_len=2;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
hex_len=4;
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
hex_len=8;
n=n+4;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (datalen(response) < n) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 63) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_wert")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
itoax(temp2,value);
strerase(temp2,0,10-hex_len);
strupper(temp2);
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
}
else {
if (strcmp(temp1,"bit")==0) {
// Bitfeld
tabget(temp1,"DATENTYP");
strlower(temp1);
if (strcmp(temp1,"bitfield")==0) {
tabget(temp2,"NAME");
tabset(temp2);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. bitfield table not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
size_bitfield=0;
size_bitfield_old=0;
line_bitfield_table=0;
tabline(line_bitfield_table);
do {
tabget(temp1,"EINHEIT");
strlower(temp1);
if (strcmp(temp1,"0/1")==0) {
// Digitaler Wert im Bitfeld
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
size_bitfield=1;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
size_bitfield=2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
size_bitfield=4;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (size_bitfield_old != size_bitfield) {
if (size_bitfield_old == 0) {
size_bitfield_old = size_bitfield;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Different bitfield size in table='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (datalen(response) < (n+size_bitfield)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"MASKE");
maske=atoi(temp1);
if ((maske & value) == maske)
value=1;
else
value=0;
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 58) { // 63 maximal RESULTNAME + '_INFO'
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (len >= 5) {
temp2="";
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
if (strcmp(temp2,"_wert")==0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
var_result_long(temp1,value);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
}
else {
if (strcmp(temp1,"0-n")==0) {
// Diskreter Wert im Bitfeld
unsigned_long_flag=FALSE;
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
value_unsigned = value;
if (strcmp(temp1,"unsigned char")!=0)
if (value & 0x80) value = value | 0xFFFFFF00;
size_bitfield=1;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
value_unsigned = value;
if ((strcmp(temp1,"unsigned int")!=0) && (strcmp(temp1,"unsigned integer")!=0))
if (value & 0x8000) value = value | 0xFFFF0000;
size_bitfield=2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
value_unsigned = value;
size_bitfield=4;
if (strcmp(temp1,"unsigned long")==0) unsigned_long_flag = TRUE;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (size_bitfield_old != size_bitfield) {
if (size_bitfield_old == 0) {
size_bitfield_old = size_bitfield;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Different bitfield size in table='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (datalen(response) < (n+size_bitfield)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"MASKE");
maske=atoi(temp1);
value = maske & value;
value_unsigned = maske & value_unsigned;
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 58) { // 63 maximal RESULTNAME + '_INFO'
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_wert")==0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (unsigned_long_flag == TRUE)
var_result_unsigned_long(temp1,value);
else
var_result_long(temp1,value);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
tabget(temp2,"NAME");
if (strcmp(temp2,"-")!=0) {
tabset(temp2);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tab_suche_unsigned("WERT",value_unsigned);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table column 'WERT' not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tabget(temp2,"TEXT");
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table column 'TEXT' not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
strerase(temp1,len,5);
strcat(temp1,"_TEXT");
var_result_string(temp1,temp2);
// wieder zur<75>ck
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table);
}
tabget(temp2,"NAME");
tabset(temp2);
}
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
line_bitfield_table++;
} while (tabline(line_bitfield_table));
n = n + size_bitfield;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"data")==0) {
// Data
tabget(temp1,"DATENTYP");
strlower(temp1);
len = strlen(temp1);
temp2="?????";
strncpy(temp2,temp1,5);
if ((strcmp(temp2,"data[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,5);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
data_pos=n;
n=n+data_len;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. Len out of range (1..255)='");
itoad(temp2,data_len);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (datalen(response) < n) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
temp2="";
if (len >= 6) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"dummy_")==0) {
// Warnung bei Dummy_
var_result_string("JOB_MESSAGE","Warning: RESULTNAME 'DUMMY_..' ignored.");
}
else {
if (len > 63) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_data")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
dataclear(temp2);
datacopy(temp2,response,data_pos,data_len);
var_result_data(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
}
}
else {
if (strcmp(temp1,"text")==0) {
// Text
tabget(temp1,"DATENTYP");
strlower(temp1);
len = strlen(temp1);
temp2="???????";
strncpy(temp2,temp1,7);
if ((strcmp(temp2,"string[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,7);
string_len=atoi(temp2);
if ((string_len > 0) && (string_len < 256)) {
string_pos=n;
n=n+string_len;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. Len out of range (1..255)='");
itoad(temp2,string_len);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"string")==0) {
k=0;
string_flag=FALSE;
while ((n+k) < datalen(response)) {
if (response[n+k]==0) {
string_flag=TRUE;
string_pos=n;
string_len=k+1;
n=n+string_len;
break;
}
k++;
}
if (string_flag==FALSE) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. String end character '0x00' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_NO_STRING_END_CHAR";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (datalen(response) < n) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 63) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_text")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
dataclear(temp2);
datacopy(temp2,response,string_pos,string_len);
temp2[string_len]=0;
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
}
else {
// Analoger Wert
data_flag=FALSE;
string_flag=FALSE;
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
if (strcmp(temp1,"unsigned char")!=0)
if (value & 0x80) value = value | 0xFFFFFF00;
itor(value_real,value);
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
if ((strcmp(temp1,"unsigned int")!=0) && (strcmp(temp1,"unsigned integer")!=0))
if (value & 0x8000) value = value | 0xFFFF0000;
itor(value_real,value);
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
itor(value_real,value);
if (strcmp(temp1,"unsigned long")==0) {
if (value & 0x80000000) {
ator(real_temp1,"4294967296");
realadd(value_real,real_temp1);
}
}
n=n+4;
}
else {
if ((strcmp(temp1,"float")==0) ||
(strcmp(temp1,"intel float")==0)) {
data_to_real(value_real,response,n,0,0);
n=n+4;
}
else {
if (strcmp(temp1,"motorola float")==0) {
data_to_real(value_real,response,n,0,1);
n=n+4;
}
else {
if ((strcmp(temp1,"double")==0) ||
(strcmp(temp1,"intel double")==0)) {
data_to_real(value_real,response,n,1,0);
n=n+8;
}
else {
if (strcmp(temp1,"motorola double")==0) {
data_to_real(value_real,response,n,1,1);
n=n+8;
}
else {
len = strlen(temp1);
temp2="?????";
strncpy(temp2,temp1,5);
if ((strcmp(temp2,"data[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,5);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
data_flag=TRUE;
data_pos=n;
n=n+data_len;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. Len out of range (1..255)='");
itoad(temp2,data_len);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
len = strlen(temp1);
temp2="???????";
strncpy(temp2,temp1,7);
if ((strcmp(temp2,"string[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,7);
string_len=atoi(temp2);
if ((string_len > 0) && (string_len < 256)) {
string_flag=TRUE;
string_pos=n;
n=n+string_len;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. Len out of range (1..255)='");
itoad(temp2,string_len);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"string")==0) {
k=0;
string_flag=FALSE;
while ((n+k) < datalen(response)) {
if (response[n+k]==0) {
string_flag=TRUE;
string_pos=n;
string_len=k+1;
n=n+string_len;
break;
}
k++;
}
if (string_flag==FALSE) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. String end character '0x00' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_NO_STRING_END_CHAR";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
}
}
}
}
}
}
}
if (datalen(response) < n) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 63) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_wert")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (data_flag==TRUE) {
dataclear(temp2);
datacopy(temp2,response,data_pos,data_len);
var_result_long(temp1,0);
strerase(temp1,len-5,5);
strcat(temp1,"_DATA");
var_result_data(temp1,temp2);
}
else {
if (string_flag==TRUE) {
dataclear(temp2);
datacopy(temp2,response,string_pos,string_len);
temp2[string_len]=0;
var_result_long(temp1,0);
strerase(temp1,len-5,5);
strcat(temp1,"_TEXT");
var_result_string(temp1,temp2);
}
else {
tabget(temp2,"MUL");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
ator(real_temp2,"0");
if (realcomp(real_temp1,"==",real_temp2))
{
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Multiplication with Zero.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
realmul(value_real,real_temp1);
}
tabget(temp2,"DIV");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
ator(real_temp2,"0");
if (realcomp(real_temp1,"==",real_temp2))
{
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Division by Zero.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
realdiv(value_real,real_temp1);
}
tabget(temp2,"ADD");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
realadd(value_real,real_temp1);
}
var_result_real(temp1,value_real);
}
}
strerase(temp1,len-5,5);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
} // else Text
} // else Data
} // else Bitfeld
} // else Hex String
} // else Diskreter Wert
} // else Digitaler Wert
if (res_table_flag==TRUE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
line_res_table++;
if (!tabline(line_res_table)) res_table_flag=FALSE;
}
} while (res_table_flag==TRUE);
if (datalen(response) != n) {
temp1="Too much data.";
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_MUCH_DATA";
set_trap_mask(0);
return;
}
JOB_STATUS = "OKAY";
set_trap_mask(0);
}
// end of : #include "UDS_2F_STEUERN_IO.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_31_STEUERN_ROUTINE.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : STEUERN_ROUTINE
// -------------------------------------------------------------------
// Globale Konstanten : TA
// UNCHECK_LEN_IDENTIFIER_LIST[]
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 31.05.2006 rd V0.01 Erstellung
// 31.05.2006 rd V0.10 Header <20>berarbeitet
// 12.06.2006 rd V0.11 Datentyp integer dazu
// 20.06.2006 rd V0.12 Datentyp BITFIELD dazu
// V0.12 Fehlermeldung bei string <20>berarbeitet
// V0.12 Unterschiedliche Result- und Argumentauswertung
// V0.12 f<>r STR, STPR, RRR
// 22.06.2006 rd V0.20 Service<63>berpr<70>fung dazu
// 24.07.2006 rd V0.21 '0-n' _WERT- Results nicht erlaubt
// 04.09.2006 rd V0.22 Erstes Result f<>hrt zu keiner Fehlermeldung
// V0.22 wenn RESULTNAME und DATENTYP und EINHEIT == '-'
// 06.03.2007 rd V0.50 Bei diskretem Argument. Wenn Argument nicht
// rd V0.50 in Spalte Text gefunden wird,
// rd V0.50 dann auch in Spalte WERT suchen
// 27.03.2007 rd V0.60 Service<63>berpr<70>fung aktiv
// rd V0.60 Resultname beginnend mit _stat_ jetzt erlaubt
// 22.05.2007 rd V0.75 Bug Bitfeld-Maske behoben
// 04.09.2007 rd V0.80 Bug Analoger Wert unsigned long / long behoben
// 06.12.2007 rd V1.00 Freigabe
// 22.11.2010 rd V2.00 Einheit DATA, TEXT dazu
// V2.00 Anforderung VH-53 Waegner
// V2.00 Integration DUMMY_ bei Einheit DATA
// V2.00 Anforderung EA-410 Lorch
// V2.00 Integration Entfall L<>ngenpr<70>fung
// V2.00 Anforderung EA-410 Lorch
// V2.00 Freigabe
// *******************************************************************
// UDS_31_STEUERN_ROUTINE.B2S @(#)@ V2.00 @(#)@
// *******************************************************************
job ( name : STEUERN_ROUTINE;
comment : Vorgeben eines Status;
comment : UDS : $31 RoutineControl;
argument : ARGUMENT_SPALTE;
type : string;
comment : 'ARG', 'ID', 'LABEL';
argument : STATUS;
type : string;
comment : Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE;
argument : STEUERPARAMETER;
type : string;
comment : 'STR' = startRoutine;
comment : 'STPR' = stopRoutine;
comment : 'RRR' = requestRoutineResults;
argument : WERT;
type : string;
comment : Argumente siehe table SG_Funktionen ARG_TABELLE;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Antwort von SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x31};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
unsigned char argument_name[];
unsigned char argument_string[];
unsigned char temp1[];
unsigned char temp2[];
unsigned char control_parameter;
unsigned char control_parameter_response;
unsigned int k;
unsigned int n;
unsigned int id;
unsigned int id_response;
unsigned int len;
unsigned int anz_arg;
unsigned int anz_arg_offset;
unsigned int found_flag;
unsigned int data_len;
unsigned int unsigned_long_flag;
unsigned int data_flag;
unsigned int data_pos;
unsigned int string_flag;
unsigned int string_pos;
unsigned int string_len;
unsigned int hex_len;
unsigned int res_table_flag;
unsigned int line_res_table;
unsigned int line_res_table_offset;
unsigned int first_result_flag;
unsigned int size_bitfield;
unsigned int size_bitfield_old;
unsigned int line_bitfield_table;
unsigned int gefunden_flag;
unsigned long argument_unsigned;
long value;
long value_unsigned;
long maske;
real value_real;
real real_temp1;
real real_temp2;
// ---------------- Argumente des Jobs auswerten ---------------------
if (exist(ARGUMENT_SPALTE)) {
argument_string = ARGUMENT_SPALTE;
strupper(argument_string);
if ((strcmp(argument_string,"ARG")!=0) &&
(strcmp(argument_string,"ID")!=0) &&
(strcmp(argument_string,"LABEL")!=0)) {
temp1="Argument ARGUMENT_SPALTE='";strcat(temp1,argument_string);strcat(temp1,"' not valid.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
}
else {
var_result_string("JOB_MESSAGE","Argument ARGUMENT_SPALTE missing ('ARG', 'ID', 'LABEL').");
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
if (!exist(STATUS)) {
temp1="Argument STATUS missing.";
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
// ---------------- Request erzeugen ---------------------------------
set_trap_mask(0x400);
tabset("SG_Funktionen");
if (get_error(10)) {
var_result_string("JOB_MESSAGE","Table 'SG_Funktionen' not found.");
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
n=1;
if (exist(STEUERPARAMETER)) {
temp2 = STEUERPARAMETER;
strupper(temp2);
if ((strcmp(temp2,"STR")!=0) &&
(strcmp(temp2,"STPR")!=0) &&
(strcmp(temp2,"RRR")!=0)) {
temp1="Argument STEUERPARAMETER='";strcat(temp1,temp2);strcat(temp1,"' not valid.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
else {
if (strcmp(temp2,"STR") ==0) control_parameter = 0x01;
if (strcmp(temp2,"STPR") ==0) control_parameter = 0x02;
if (strcmp(temp2,"RRR") ==0) control_parameter = 0x03;
request[n++] = control_parameter;
}
}
else {
var_result_string("JOB_MESSAGE","Argument STEUERPARAMETER missing ('STR', 'STPR', 'RRR').");
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
argument_name=STATUS;
if (strcmp(argument_name,"-")==0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"' not valid.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (!tabseek(argument_string,argument_name)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp2,"SERVICE");
if (strcmp(temp2,"-")!=0) {
strupper(temp2);
k=0;
gefunden_flag=FALSE;
while (temp2[k]!=0){
if (temp2[k]=='3') {
if (temp2[k+1]=='1') {
gefunden_flag=TRUE;
break;
}
}
k++;
}
if (gefunden_flag==FALSE) {
temp1="Argument STATUS='";strcat(temp1,argument_name);
strcat(temp1,"' not valid. Service '31' not found in Table 'SG_Funktionen' column 'SERVICE'='");
tabget(temp2,"SERVICE");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp2,"ID");
id = atoi(temp2);
request[n++] = id >> 8;
request[n++] = id & 0xFF;
tabget(argument_string,"ARG_TABELLE");
if ((control_parameter != 0x03) && (strcmp(argument_string,"-")!=0)) {
// nur StartRoutine oder StopRoutine und Tabelle vorhanden
tabset(argument_string);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Argument table not found='");
strcat(temp1,argument_string);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (WERT); // damit die Compilerwarnung entf<74>llt
anz_arg=0;
anz_arg_offset=0;
while (tabline(anz_arg + anz_arg_offset)) {
if (control_parameter == 0x01) tabget(temp2,"STR");
if (control_parameter == 0x02) tabget(temp2,"STPR");
if (get_error(10)) temp2="+"; // falls Spalte nicht existiert
if ((strcmp(temp2,"+")!=0) && (strcmp(temp2,"-")!=0)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
if (control_parameter == 0x01) {
strcat(temp1,"'. STR not valid='");
tabget(temp2,"STR");
}
if (control_parameter == 0x02) {
strcat(temp1,"'. STPR not valid='");
tabget(temp2,"STPR");
}
strcat(temp1,temp2);strcat(temp1,"' ('+', '-').");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (strcmp(temp2,"+")==0) {
if (!get_argument(argument_name,anz_arg+4)) {
tabget(temp1,"DATENTYP");
strlower(temp1);
if (strcmp(temp1,"string")!=0) { // Leerstring erlauben
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);
strcat(temp1,"] missing. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"EINHEIT");
strlower(temp1);
if (strcmp(temp1,"0/1")==0) {
// Digitaler Wert
aitor(value_real,argument_name);
value=atoi(argument_name);
if ((strcmp(argument_name,"0")!=0) && (strcmp(argument_name,"1")!=0)) {
temp1="Argument WERT[";
itoad(temp2,anz_arg+1);
strcat(temp1,temp2);strcat(temp1,"] Digital value not valid='");
strcat(temp1,argument_name);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp1,"MIN");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' < MIN='");tabget(temp2,"MIN");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"MAX");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' > MAX='");tabget(temp2,"MAX");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
request[n] = value;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP not valid='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
}
else {
if (strcmp(temp1,"0-n")==0) {
// Diskreter Wert
tabget(temp2,"NAME");
if (strcmp(temp2,"-")==0) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. NAME not valid='");tabget(temp2,"NAME");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tabset(temp2);
if (get_error(10)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg + anz_arg_offset);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete value table not found='");
tabget(temp2,"NAME");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
found_flag=tabseek("TEXT",argument_name);
if (get_error(10)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg + anz_arg_offset);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete value table='");
tabget(temp2,"NAME");strcat(temp1,temp2);
strcat(temp1,"'. Column 'TEXT' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (found_flag!=TRUE) {
// Wenn nicht in Spalte Text gefunden, dann auch in Spalte Wert als Zahl suchen
if (is_hex_string(argument_name) || is_unsigned_string(argument_name)) {
argument_unsigned = atoi(argument_name);
found_flag=tab_suche_unsigned("WERT",argument_unsigned);
if (get_error(10)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg + anz_arg_offset);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete value table='");
tabget(temp2,"NAME");strcat(temp1,temp2);
strcat(temp1,"'. Column 'WERT' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (found_flag!=TRUE) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg + anz_arg_offset);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete table='");
tabget(temp2,"NAME");strcat(temp1,temp2);
strcat(temp1,"'. Argument not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp1,"WERT");
aitor(value_real,temp1);
value=atoi(temp1);
if (get_error(10)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
tabset(argument_string);tabline(anz_arg + anz_arg_offset);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Discrete value table='");
tabget(temp2,"NAME");strcat(temp1,temp2);
strcat(temp1,"'. Column 'WERT' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
// wieder zur<75>ck zur Tabelle
tabset(argument_string);
tabline(anz_arg + anz_arg_offset);
tabget(temp1,"MIN");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' < MIN='");tabget(temp2,"MIN");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"MAX");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' > MAX='");tabget(temp2,"MAX");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
request[n] = value;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP not valid='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
}
else {
if (strcmp(temp1,"hex")==0) {
// Hex String
aitor(value_real,argument_name);
value=atoi(argument_name);
tabget(temp1,"MIN");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' < MIN='");tabget(temp2,"MIN");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"MAX");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' > MAX='");tabget(temp2,"MAX");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
request[n] = value;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP not valid='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
}
else {
// Analoger Wert
tabget(temp1,"DATENTYP");
strlower(temp1);
len = strlen(temp1);
temp2="?????";
strncpy(temp2,temp1,5);
if ((strcmp(temp2,"data[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,5);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
len=strlen(argument_name);
if (len == 2*data_len) {
ascii2hex(request,argument_name,n);
n=n+data_len;
if (datalen(request) != n) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Invalid characters in argument. Valid characters=0123456789ABCDEF.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
if (len < 2*data_len)
strcat(temp1,"'. Too less data. Expected argument string len='");
else
strcat(temp1,"'. Too much data. Expected argument string len='");
itoad(temp2,2*data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Len out of range (1..255)='");itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
len = strlen(temp1);
temp2="???????";
strncpy(temp2,temp1,7);
if ((strcmp(temp2,"string[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,7);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
len=strlen(argument_name);
if (len == data_len) {
datacat(request,argument_name);
dataerase(request,n+data_len,1); // String end character '0x00' entfernen
n=n+data_len;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
if (len < data_len)
strcat(temp1,"'. Too less data. Expected argument string len='");
else
strcat(temp1,"'. Too much data. Expected argument string len='");
itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Len out of range (1..255)='");itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"string")==0) {
data_len=strlen(argument_name)+1; // String end character '0x00'
if ((data_len > 0) && (data_len < 256)) {
datacat(request,argument_name);
n=n+data_len;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Len out of range (1..255)='");itoad(temp2,data_len);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
else {
aitor(value_real,argument_name);
tabget(temp1,"MIN");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' < MIN='");tabget(temp2,"MIN");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp1,"MAX");
if (strcmp(temp1,"-")!=0) {
aitor(real_temp1,temp1);
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
strcat(temp1,argument_name);strcat(temp1,"' > MAX='");tabget(temp2,"MAX");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
tabget(temp2,"MUL");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
ator(real_temp2,"0");
if (realcomp(real_temp1,"==",real_temp2))
{
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Multiplication with Zero.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
realmul(value_real,real_temp1);
}
tabget(temp2,"DIV");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
ator(real_temp2,"0");
if (realcomp(real_temp1,"==",real_temp2))
{
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. Division by Zero.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
realdiv(value_real,real_temp1);
}
tabget(temp2,"ADD");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
realadd(value_real,real_temp1);
}
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value=rtoi_round(value_real);
if (value < -128) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' < -128.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (value > 127) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' > 127.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
request[n] = value;
n++;
}
else {
if (strcmp(temp1,"unsigned char")==0) {
value=rtoi_round(value_real);
if (value < 0) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' < 0.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (value > 255) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' > 255.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
request[n] = value;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
value=rtoi_round(value_real);
if (value < -32768) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' < -32768.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (value > 32767) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' > 32767.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0)) {
value=rtoi_round(value_real);
if (value < 0) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' < 0.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
if (value > 65535) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
itoad(temp2,value);strcat(temp1,temp2);strcat(temp1,"' > 65535.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
}
else {
request[n+1] = value;
request[n] = value>>8;
}
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"signed long")==0)) {
ator(real_temp1,"-2147483648");
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' < -2147483648.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"2147483647");
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' > 2147483647.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
value=rtoi_round(value_real);
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
if (strcmp(temp1,"unsigned long")==0) {
ator(real_temp1,"0");
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' < 0.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"4294967295");
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' > 4294967295.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
value=rtoi_round(value_real);
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L')) {
request[n] = value;
request[n+1] = value>>8;
request[n+2] = value>>16;
request[n+3] = value>>24;
}
else {
request[n+3] = value;
request[n+2] = value>>8;
request[n+1] = value>>16;
request[n] = value>>24;
}
n=n+4;
}
else {
if ((strcmp(temp1,"float")==0) ||
(strcmp(temp1,"intel float")==0)) {
ator(real_temp1,"-3.4028234663852884E+038");
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' < -3.4028234663852884E+038");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"3.4028234663852884E+038");
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' > 3.4028234663852884E+038");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"0");
if (realcomp(value_real,">",real_temp1)) {
ator(real_temp1,"1.1754943508222877E-038");
if (realcomp(value_real,"<",real_temp1)) {
value_real=real_temp1;
}
}
ator(real_temp1,"0");
if (realcomp(value_real,"<",real_temp1)) {
ator(real_temp1,"-1.1754943508222877E-038");
if (realcomp(value_real,">",real_temp1)) {
value_real=real_temp1;
}
}
real_to_data(request,value_real,n,0,0);
n=n+4;
}
else {
if (strcmp(temp1,"motorola float")==0) {
ator(real_temp1,"-3.4028234663852884E+038");
if (realcomp(value_real,"<",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' < -3.4028234663852884E+038");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"3.4028234663852884E+038");
if (realcomp(value_real,">",real_temp1)) {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);
strcat(temp1,"'. Out of range. '");
rtoa(temp2,value_real,0);strcat(temp1,temp2);strcat(temp1,"' > 3.4028234663852884E+038");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
ator(real_temp1,"0");
if (realcomp(value_real,">",real_temp1)) {
ator(real_temp1,"1.1754943508222877E-038");
if (realcomp(value_real,"<",real_temp1)) {
value_real=real_temp1;
}
}
ator(real_temp1,"0");
if (realcomp(value_real,"<",real_temp1)) {
ator(real_temp1,"-1.1754943508222877E-038");
if (realcomp(value_real,">",real_temp1)) {
value_real=real_temp1;
}
}
real_to_data(request,value_real,n,0,1);
n=n+4;
}
else {
if ((strcmp(temp1,"double")==0) ||
(strcmp(temp1,"intel double")==0)) {
real_to_data(request,value_real,n,1,0);
n=n+8;
}
else {
if (strcmp(temp1,"motorola double")==0) {
real_to_data(request,value_real,n,1,1);
n=n+8;
}
else {
temp1="Argument WERT[";itoad(temp2,anz_arg+1);strcat(temp1,temp2);strcat(temp1,"]='");strcat(temp1,argument_name);
strcat(temp1,"'. Argument table='");strcat(temp1,argument_string);
strcat(temp1,"'. Argument='");tabget(temp2,"ARG");strcat(temp1,temp2);
strcat(temp1,"'. DATENTYP not valid='");tabget(temp2,"DATENTYP");strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
} // else Analog motorola double
} // else Analog (intel) double
} // else Analog motorola float
} // else Analog (intel) float
} // else Analog unsigned long
} // else Analog (signed) long
} // else Analog unsigned int
} // else Analog (signed) int
} // else Analog unsigned char
} // else Analog (signed) char
} // else Analog string
} // else Analog string[x]
} // else Analog data[x]
} // else Hex String
} // else Diskreter Wert
} // else Digitaler Wert
anz_arg++;
} // temp2 == "+" ?
else {
anz_arg_offset++;
}
}
if (get_argument(temp1,anz_arg+4)) {
temp1="Argument WERT[";
itoad(temp2,anz_arg+1);
strcat(temp1,temp2);strcat(temp1,"]='");
get_argument(temp2,anz_arg+4);
strcat(temp1,temp2);strcat(temp1,"'. Too many arguments. Number of arguments='");
itoad(temp2,anz_arg);strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
} // if ((control_parameter != 0x03) && (strcmp(argument_string,"-")!=0))
else {
k=0;
while (!get_argument(temp1,k+4)) {
if (k >= 31) break;
k++;
}
if (strlen(temp1) > 0) {
temp1="Argument WERT[";
itoad(temp2,k+1);
strcat(temp1,temp2);strcat(temp1,"]='");
get_argument(temp2,k+4);
strcat(temp1,temp2);strcat(temp1,"'. Too many arguments. Number of arguments='0'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ARGUMENT";
set_trap_mask(0);
return;
}
}
// ---------------- Kommunikation ------------------------------------
if (_REQUEST) _REQUEST = request;
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "_RESPONSE", 2)) {
set_trap_mask(0);
return;
}
// ---------------- Response auswerten -------------------------------
if (datalen(response) < 4) {
argument_name=STATUS;
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
control_parameter_response = response[1];
if (control_parameter_response != control_parameter) {
argument_name=STATUS;
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Incorrect response io control parameter. Expected='");
itoax(temp2,control_parameter);strerase(temp2,2,6);
strcat(temp1,temp2);strcat(temp1,"' != Response='");
itoax(temp2,control_parameter_response);strerase(temp2,2,6);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_TYPE";
set_trap_mask(0);
return;
}
id_response = (response[2]<<8)+response[3];
if (id_response != id) {
argument_name=STATUS;
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Incorrect response data identifier. Expected='");
itoax(temp2,id);strerase(temp2,2,4);
strcat(temp1,temp2);strcat(temp1,"' != Response='");
itoax(temp2,id_response);strerase(temp2,2,4);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER";
set_trap_mask(0);
return;
}
n=4;
tabset("SG_Funktionen");
argument_string = ARGUMENT_SPALTE;
argument_name=STATUS;
tabseek(argument_string,argument_name);
res_table_flag=FALSE;
tabget(temp2,"RES_TABELLE");
if (strcmp(temp2,"-")!=0) {
tabset(temp2);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Result table not found='");
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
res_table_flag=TRUE;
line_res_table=0;
line_res_table_offset=0;
tabline(line_res_table + line_res_table_offset);
}
first_result_flag=TRUE;
do {
if (control_parameter == 0x01) tabget(temp2,"STR");
if (control_parameter == 0x02) tabget(temp2,"STPR");
if (control_parameter == 0x03) tabget(temp2,"RRR");
if (get_error(10)) temp2="+"; // falls Spalte nicht existiert
if ((strcmp(temp2,"+")!=0) && (strcmp(temp2,"-")!=0)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);
if (control_parameter == 0x01) {
strcat(temp1,"'. STR not valid='");
tabget(temp2,"STR");
}
if (control_parameter == 0x02) {
strcat(temp1,"'. STPR not valid='");
tabget(temp2,"STPR");
}
if (control_parameter == 0x03) {
strcat(temp1,"'. RRR not valid='");
tabget(temp2,"RRR");
}
strcat(temp1,temp2);strcat(temp1,"' ('+', '-').");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (strcmp(temp2,"+")==0) {
if (first_result_flag == TRUE) {
tabget(temp1,"RESULTNAME");
if (strcmp(temp1,"-")==0) {
tabget(temp1,"DATENTYP");
if (strcmp(temp1,"-")==0) {
tabget(temp1,"EINHEIT");
if (strcmp(temp1,"-")==0) break;
}
}
first_result_flag=FALSE;
}
// L<>ngenpr<70>fung abschalten ?
// nur wenn keine Restdaten vorhanden
if (datalen(response) == n) {
len = datalen(UNCHECK_LEN_IDENTIFIER_LIST) / 2 ; // 1 Integer = 2 Byte
k=0;
do {
if (UNCHECK_LEN_IDENTIFIER_LIST[k] != 0) {
if (UNCHECK_LEN_IDENTIFIER_LIST[k] == id) {
// Zu wenig Daten. Restliche Results werden nicht erzeugt
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data. UNCHECK_LEN_IDENTIFIER_LIST contains ID='");
itoax(temp2,id);strerase(temp2,2,4);
strcat(temp1,temp2);strcat(temp1,"'. WARNING: Remaining results are not created.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "OKAY";
set_trap_mask(0);
return;
}
}
k++;
} while (k<len);
}
tabget(temp1,"EINHEIT");
strlower(temp1);
if (strcmp(temp1,"0/1")==0) {
// Digitaler Wert
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
n=n+4;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (datalen(response) < n) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 58) { // 63 maximal RESULTNAME + '_INFO'
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (len >= 5) {
temp2="";
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
if (strcmp(temp2,"_wert")==0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
var_result_long(temp1,value);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
if ((value!=0) && (value!=1)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Digital value not valid='");
itoad(temp2,value);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"0-n")==0) {
// Diskreter Wert
unsigned_long_flag=FALSE;
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
value_unsigned = value;
if (strcmp(temp1,"unsigned char")!=0)
if (value & 0x80) value = value | 0xFFFFFF00;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
value_unsigned = value;
if ((strcmp(temp1,"unsigned int")!=0) && (strcmp(temp1,"unsigned integer")!=0))
if (value & 0x8000) value = value | 0xFFFF0000;
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
value_unsigned = value;
n=n+4;
if (strcmp(temp1,"unsigned long")==0) unsigned_long_flag = TRUE;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (datalen(response) < n) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 58) { // 63 maximal RESULTNAME + '_INFO'
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_wert")==0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (unsigned_long_flag == TRUE)
var_result_unsigned_long(temp1,value);
else
var_result_long(temp1,value);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
tabget(temp2,"NAME");
if (strcmp(temp2,"-")!=0) {
tabset(temp2);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table + line_res_table_offset);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tab_suche_unsigned("WERT",value_unsigned);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table column 'WERT' not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table + line_res_table_offset);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tabget(temp2,"TEXT");
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table column 'TEXT' not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table + line_res_table_offset);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
strerase(temp1,len,5);
strcat(temp1,"_TEXT");
var_result_string(temp1,temp2);
}
}
else {
if (strcmp(temp1,"hex")==0) {
// Hex String
unsigned_long_flag=FALSE;
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
hex_len=2;
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
hex_len=4;
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
hex_len=8;
n=n+4;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (datalen(response) < n) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 63) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_wert")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
itoax(temp2,value);
strerase(temp2,0,10-hex_len);
strupper(temp2);
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
}
else {
if (strcmp(temp1,"bit")==0) {
// Bitfeld
tabget(temp1,"DATENTYP");
strlower(temp1);
if (strcmp(temp1,"bitfield")==0) {
tabget(temp2,"NAME");
tabset(temp2);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. bitfield table not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table + line_res_table_offset);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
size_bitfield=0;
size_bitfield_old=0;
line_bitfield_table=0;
tabline(line_bitfield_table);
do {
tabget(temp1,"EINHEIT");
strlower(temp1);
if (strcmp(temp1,"0/1")==0) {
// Digitaler Wert im Bitfeld
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
size_bitfield=1;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
size_bitfield=2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
size_bitfield=4;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (size_bitfield_old != size_bitfield) {
if (size_bitfield_old == 0) {
size_bitfield_old = size_bitfield;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Different bitfield size in table='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table + line_res_table_offset);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (datalen(response) < (n+size_bitfield)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"MASKE");
maske=atoi(temp1);
if ((maske & value) == maske)
value=1;
else
value=0;
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 58) { // 63 maximal RESULTNAME + '_INFO'
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (len >= 5) {
temp2="";
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
if (strcmp(temp2,"_wert")==0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
var_result_long(temp1,value);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
}
else {
if (strcmp(temp1,"0-n")==0) {
// Diskreter Wert im Bitfeld
unsigned_long_flag=FALSE;
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
value_unsigned = value;
if (strcmp(temp1,"unsigned char")!=0)
if (value & 0x80) value = value | 0xFFFFFF00;
size_bitfield=1;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
value_unsigned = value;
if ((strcmp(temp1,"unsigned int")!=0) && (strcmp(temp1,"unsigned integer")!=0))
if (value & 0x8000) value = value | 0xFFFF0000;
size_bitfield=2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
value_unsigned = value;
size_bitfield=4;
if (strcmp(temp1,"unsigned long")==0) unsigned_long_flag = TRUE;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
if (size_bitfield_old != size_bitfield) {
if (size_bitfield_old == 0) {
size_bitfield_old = size_bitfield;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Different bitfield size in table='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table + line_res_table_offset);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (datalen(response) < (n+size_bitfield)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"MASKE");
maske=atoi(temp1);
value = maske & value;
value_unsigned = maske & value_unsigned;
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 58) { // 63 maximal RESULTNAME + '_INFO'
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_wert")==0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (unsigned_long_flag == TRUE)
var_result_unsigned_long(temp1,value);
else
var_result_long(temp1,value);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
tabget(temp2,"NAME");
if (strcmp(temp2,"-")!=0) {
tabset(temp2);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table + line_res_table_offset);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tab_suche_unsigned("WERT",value_unsigned);
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table column 'WERT' not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table + line_res_table_offset);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
tabget(temp2,"TEXT");
if (get_error(10)) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Discrete value table column 'TEXT' not found='");
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table + line_res_table_offset);
}
tabget(temp2,"NAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
strerase(temp1,len,5);
strcat(temp1,"_TEXT");
var_result_string(temp1,temp2);
// wieder zur<75>ck
if (res_table_flag==FALSE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
}
else {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
tabline(line_res_table + line_res_table_offset);
}
tabget(temp2,"NAME");
tabset(temp2);
}
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
line_bitfield_table++;
} while (tabline(line_bitfield_table));
n = n + size_bitfield;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"data")==0) {
// Data
tabget(temp1,"DATENTYP");
strlower(temp1);
len = strlen(temp1);
temp2="?????";
strncpy(temp2,temp1,5);
if ((strcmp(temp2,"data[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,5);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
data_pos=n;
n=n+data_len;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. Len out of range (1..255)='");
itoad(temp2,data_len);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
if (datalen(response) < n) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
temp2="";
if (len >= 6) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"dummy_")==0) {
// Warnung bei Dummy_
var_result_string("JOB_MESSAGE","Warning: RESULTNAME 'DUMMY_..' ignored.");
}
else {
if (len > 63) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_data")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
dataclear(temp2);
datacopy(temp2,response,data_pos,data_len);
var_result_data(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
}
}
else {
if (strcmp(temp1,"text")==0) {
// Text
tabget(temp1,"DATENTYP");
strlower(temp1);
len = strlen(temp1);
temp2="???????";
strncpy(temp2,temp1,7);
if ((strcmp(temp2,"string[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,7);
string_len=atoi(temp2);
if ((string_len > 0) && (string_len < 256)) {
string_pos=n;
n=n+string_len;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. Len out of range (1..255)='");
itoad(temp2,string_len);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"string")==0) {
k=0;
string_flag=FALSE;
while ((n+k) < datalen(response)) {
if (response[n+k]==0) {
string_flag=TRUE;
string_pos=n;
string_len=k+1;
n=n+string_len;
break;
}
k++;
}
if (string_flag==FALSE) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. String end character '0x00' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_NO_STRING_END_CHAR";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (datalen(response) < n) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 63) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_text")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
dataclear(temp2);
datacopy(temp2,response,string_pos,string_len);
temp2[string_len]=0;
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
}
else {
// Analoger Wert
data_flag=FALSE;
string_flag=FALSE;
tabget(temp1,"DATENTYP");
strlower(temp1);
if ((strcmp(temp1,"char")==0) ||
(strcmp(temp1,"unsigned char")==0) ||
(strcmp(temp1,"signed char")==0)) {
value = response[n];
if (strcmp(temp1,"unsigned char")!=0)
if (value & 0x80) value = value | 0xFFFFFF00;
itor(value_real,value);
n++;
}
else {
if ((strcmp(temp1,"int")==0) ||
(strcmp(temp1,"integer")==0) ||
(strcmp(temp1,"unsigned int")==0) ||
(strcmp(temp1,"unsigned integer")==0) ||
(strcmp(temp1,"signed int")==0) ||
(strcmp(temp1,"signed integer")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+1]<<8)+response[n];
else
value = (response[n]<<8)+response[n+1];
if ((strcmp(temp1,"unsigned int")!=0) && (strcmp(temp1,"unsigned integer")!=0))
if (value & 0x8000) value = value | 0xFFFF0000;
itor(value_real,value);
n=n+2;
}
else {
if ((strcmp(temp1,"long")==0) ||
(strcmp(temp1,"unsigned long")==0) ||
(strcmp(temp1,"signed long")==0)) {
tabget(temp2,"L/H");
if ((temp2[0]=='l') || (temp2[0]=='L'))
value = (response[n+3]<<24)+(response[n+2]<<16)+(response[n+1]<<8)+response[n];
else
value = (response[n]<<24)+(response[n+1]<<16)+(response[n+2]<<8)+response[n+3];
itor(value_real,value);
if (strcmp(temp1,"unsigned long")==0) {
if (value & 0x80000000) {
ator(real_temp1,"4294967296");
realadd(value_real,real_temp1);
}
}
n=n+4;
}
else {
if ((strcmp(temp1,"float")==0) ||
(strcmp(temp1,"intel float")==0)) {
data_to_real(value_real,response,n,0,0);
n=n+4;
}
else {
if (strcmp(temp1,"motorola float")==0) {
data_to_real(value_real,response,n,0,1);
n=n+4;
}
else {
if ((strcmp(temp1,"double")==0) ||
(strcmp(temp1,"intel double")==0)) {
data_to_real(value_real,response,n,1,0);
n=n+8;
}
else {
if (strcmp(temp1,"motorola double")==0) {
data_to_real(value_real,response,n,1,1);
n=n+8;
}
else {
len = strlen(temp1);
temp2="?????";
strncpy(temp2,temp1,5);
if ((strcmp(temp2,"data[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,5);
data_len=atoi(temp2);
if ((data_len > 0) && (data_len < 256)) {
data_flag=TRUE;
data_pos=n;
n=n+data_len;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. Len out of range (1..255)='");
itoad(temp2,data_len);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
len = strlen(temp1);
temp2="???????";
strncpy(temp2,temp1,7);
if ((strcmp(temp2,"string[")==0) && temp1[len-1]==']') {
temp2=temp1;
strerase(temp2,len-1,1);
strerase(temp2,0,7);
string_len=atoi(temp2);
if ((string_len > 0) && (string_len < 256)) {
string_flag=TRUE;
string_pos=n;
n=n+string_len;
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. Len out of range (1..255)='");
itoad(temp2,string_len);
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
else {
if (strcmp(temp1,"string")==0) {
k=0;
string_flag=FALSE;
while ((n+k) < datalen(response)) {
if (response[n+k]==0) {
string_flag=TRUE;
string_pos=n;
string_len=k+1;
n=n+string_len;
break;
}
k++;
}
if (string_flag==FALSE) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP '");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'. String end character '0x00' not found.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_NO_STRING_END_CHAR";
set_trap_mask(0);
return;
}
}
else {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. DATENTYP not valid='");
tabget(temp2,"DATENTYP");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
}
}
}
}
}
}
}
}
if (datalen(response) < n) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Too less data.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_LESS_DATA";
set_trap_mask(0);
return;
}
tabget(temp1,"RESULTNAME");
len=strlen(temp1);
if (len > 63) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME to long='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[len-5];
temp2[1] = temp1[len-4];
temp2[2] = temp1[len-3];
temp2[3] = temp1[len-2];
temp2[4] = temp1[len-1];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_wert")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
temp2="";
if (len >= 5) {
temp2[0] = temp1[0];
temp2[1] = temp1[1];
temp2[2] = temp1[2];
temp2[3] = temp1[3];
temp2[4] = temp1[4];
temp2[5] = 0;
strlower(temp2);
}
if (strcmp(temp2,"stat_")!=0) {
if (len >= 6) {
temp2[5] = temp1[5];
temp2[6] = 0;
strlower(temp2);
}
if (strcmp(temp2,"_stat_")!=0) {
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. RESULTNAME not valid='");
tabget(temp2,"RESULTNAME");
strcat(temp1,temp2);strcat(temp1,"'.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
}
if (data_flag==TRUE) {
dataclear(temp2);
datacopy(temp2,response,data_pos,data_len);
var_result_long(temp1,0);
strerase(temp1,len-5,5);
strcat(temp1,"_DATA");
var_result_data(temp1,temp2);
}
else {
if (string_flag==TRUE) {
dataclear(temp2);
datacopy(temp2,response,string_pos,string_len);
temp2[string_len]=0;
var_result_long(temp1,0);
strerase(temp1,len-5,5);
strcat(temp1,"_TEXT");
var_result_string(temp1,temp2);
}
else {
tabget(temp2,"MUL");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
ator(real_temp2,"0");
if (realcomp(real_temp1,"==",real_temp2))
{
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Multiplication with Zero.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
realmul(value_real,real_temp1);
}
tabget(temp2,"DIV");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
ator(real_temp2,"0");
if (realcomp(real_temp1,"==",real_temp2))
{
temp1="Argument STATUS='";strcat(temp1,argument_name);strcat(temp1,"'. Division by Zero.");
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_TABLE";
set_trap_mask(0);
return;
}
realdiv(value_real,real_temp1);
}
tabget(temp2,"ADD");
if (strcmp(temp2,"-")!=0) {
aitor(real_temp1,temp2);
realadd(value_real,real_temp1);
}
var_result_real(temp1,value_real);
}
}
strerase(temp1,len-5,5);
strcat(temp1,"_EINH");
tabget(temp2,"EINHEIT");
var_result_string(temp1,temp2);
strerase(temp1,len-5,5);
strcat(temp1,"_INFO");
tabget(temp2,"INFO");
var_result_string(temp1,temp2);
} // else Text
} // else Data
} // else Bitfeld
} // else Hex String
} // else Diskreter Wert
} // else Digitaler Wert
line_res_table++;
} // temp2 == "+" ?
else {
line_res_table_offset++;
}
if (res_table_flag==TRUE) {
tabset("SG_Funktionen");
tabseek(argument_string,argument_name);
tabget(temp2,"RES_TABELLE");
tabset(temp2);
if (!tabline(line_res_table + line_res_table_offset)) res_table_flag=FALSE;
}
} while (res_table_flag==TRUE);
if (datalen(response) != n) {
temp1="Too much data.";
var_result_string("JOB_MESSAGE",temp1);
JOB_STATUS = "ERROR_ECU_RESPONSE_TOO_MUCH_DATA";
set_trap_mask(0);
return;
}
JOB_STATUS = "OKAY";
set_trap_mask(0);
}
// end of : #include "UDS_31_STEUERN_ROUTINE.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_85_02_FS_SPERREN.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : FS_SPERREN
// -------------------------------------------------------------------
// Globale Tabelle : JobResult,DigitalArgument
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 13.12.2005 gr V0.001 Ersterstellung
// 02.02.2006 gr V0.002 STD_DIGI ersetzt UDS_TAB_DIGITAL_ARGUMENT
// *******************************************************************
// UDS_85_02_FS_SPERREN.B2S @(#)@ V0.002 @(#)@
// *******************************************************************
job ( name : FS_SPERREN;
comment : Sperren bzw. Freigeben des Fehlerspeichers;
comment : UDS : $85 ControlDTCSetting;
comment : UDS : $?? Sperren ($02) / Freigabe ($01);
comment : Modus: Default;
argument : SPERREN;
type : string;
comment : "ja" -> Fehlerspeicher sperren;
comment : "nein" -> Fehlerspeicher freigeben;
comment : table DigitalArgument TEXT;
comment : Default: "ja";
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x85, 0x02};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
int LIErgebnis;
// ---------------- Ueberpruefung ob Tabellen includiert sind --------
INCLUDE_STD_DIGI_B2S_NOT_FOUND;
// ---------------- Argumente des Jobs auswerten ---------------------
if (exist(SPERREN))
{
if (!check_digital_argument("SPERREN" , 1, LIErgebnis, 2)) return;
if (LIErgebnis != 1) // 'Nein' angegeben
request[1] = 0x01; // Fehlerspeicher wieder freigeben
}
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_85_02_FS_SPERREN.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_20_00_IS_LESEN.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : IS_LESEN
// -------------------------------------------------------------------
// Globale Tabelle : JobResult, IOrtTexte, IArtTexte
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 05.12.2005 gr V0.001 Erstellung
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Tabellen-Name)
// 22.06.2006 gh V0.003 Angleichung der Auswertung an Job FS_LESEN
// 15.09.2008 gr V0.004 Ausgabe des F_HEX_CODE korrigiert (dataclear(temp))
// *******************************************************************
// UDS_22_20_00_IS_LESEN.B2S @(#)@ V0.004 @(#)@
// *******************************************************************
job ( name : IS_LESEN;
comment : Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art);
comment : UDS : $22 ReadDataByIdentifierRequestServiceID;
comment : UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher;
comment : Modus: Default;
result : F_VERSION;
type : int;
defrslt : 3;
comment : Typ des Fehlerspeichers;
comment : Fuer UDS immer 3;
result : F_HEX_CODE;
type : data;
comment : Fehlerdaten pro Fehler als Hexcode;
result : F_ORT_NR;
type : long;
comment : Index fuer Fehlerort;
result : F_ORT_TEXT;
type : string;
comment : Fehlerort als Text;
comment : table FOrtTexte ORTTEXT;
result : F_EREIGNIS_DTC;
type : int;
comment : 0: DTC kein Ereignis DTC;
comment : 1: DTC ist Ereignis DTC;
comment : table FOrtTexte EREIGNIS_DTC;
result : F_READY_NR;
type : int;
comment : Readyness Flag (Standard-Fehlerart) als Zahl;
result : F_READY_TEXT;
type : string;
comment : Readyness Flag (Standard-Fehlerart) als Text;
comment : table FArtTexte ARTTEXT;
result : F_VORHANDEN_NR;
type : int;
comment : Fehler vorhanden (Standard-Fehlerart) als Zahl;
result : F_VORHANDEN_TEXT;
type : string;
comment : Fehler vorhanden (Standard-Fehlerart) als Text;
comment : table FArtTexte ARTTEXT;
result : F_WARNUNG_NR;
type : int;
comment : Warnlampen Flag (Standard-Fehlerart) als Zahl;
result : F_WARNUNG_TEXT;
type : string;
comment : Warnlampen Flag (Standard-Fehlerart) als Text;
comment : table FArtTexte ARTTEXT;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// Variablen fuer Kommunikation
unsigned char request[] = {0x22, 0x20, 0x00};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// Variablen fuer Job
unsigned char temp[];
unsigned char text[];
int anzahl;
int index;
int offset;
long wert;
int LIStatusDTC = 0x00;
// ---------------- Ueberpruefung ob Tabellen includiert sind --------
INCLUDE_UDS_TAB_IArtTexte_B2S_NOT_FOUND;
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
index = 0;
offset = 3;
anzahl = (datalen(response) - 3) / 4;
// Verifikation der Datenlaenge
if (datalen(response) != (3 + (anzahl*4))) { // Rundungsfehler bei Berechnung der ANZAHL
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "ERROR_ECU_INCORRECT_LEN";
return;
}
while (index < anzahl) {
LIStatusDTC = response[offset + 3] & 0x4D; // Auslesen des Status Bytes. F<>r die Auswertung sind die Bits 0,2,3,6 entscheidend
if (F_HEX_CODE) {
dataclear(temp);
datacopy(temp, response, offset, 4);
F_HEX_CODE = temp;
}
if (F_ORT_NR || F_ORT_TEXT || F_EREIGNIS_DTC || F_READY_NR || F_READY_TEXT || F_VORHANDEN_NR || F_VORHANDEN_TEXT || F_WARNUNG_NR || F_WARNUNG_TEXT) {
// Ausgabe Fehlerort
wert = (response[offset] << 16) + (response[offset + 1] << 8) + response[offset + 2];
F_ORT_NR = wert;
// Dazugehoeriger Fehlertext
tabset("IOrtTexte");
tab_suche_unsigned("ORT", wert);
tabget(text, "ORTTEXT");
F_ORT_TEXT = text;
// Ereignis-DTC ja / nein
tabget(text, "EREIGNIS_DTC");
F_EREIGNIS_DTC = atoi(text);
// Gibt an, ob Test seit dem letzten loeschen einmal komplett durchlaufen wurde; Offset 0x10 wird addiert, um Tabelle FArtTexte verwenden zu k<>nnen
wert = ((response[offset+3] >> 4) & 0x01) + 0x10;
F_READY_NR = wert;
tabset("IArtTexte");
tab_suche_unsigned("ARTNR", wert);
tabget(text, "ARTTEXT");
F_READY_TEXT = text;
// Fehler aktuell vorhanden? Bit 0 und Bit 6 muessen beide 1 beinhalten, dann ist Fehler aktuell vorhanden
F_VORHANDEN_NR = LIStatusDTC;
tab_suche_unsigned("ARTNR", LIStatusDTC);
tabget(text, "ARTTEXT");
F_VORHANDEN_TEXT = text;
// Geht eine Warnlampe an oder nicht
wert = ((response[offset+3] >> 7) & 0x01) + 0x80;
F_WARNUNG_NR = wert;
tab_suche_unsigned("ARTNR", wert);
tabget(text, "ARTTEXT");
F_WARNUNG_TEXT = text;
}
new_set_of_results(); // neuer Ergebnissatz
index++;
offset += 4;
}
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_22_20_00_IS_LESEN.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_20_00_IS_LESEN_DETAIL.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : IS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, IOrtTexte, IArtTexte, IDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// IUmweltTexte
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// -------------------------------------------------------------------
// Hinweise allgemein:
// (1) : JOB_STATUS = "ERROR_TABLE"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// erkannt wird, dass eine Tabelle falsch befuellt ist.
// (2) : JOB_STATUS = "ERROR_INTERPRETATION"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// ein Fall auftritt, der undefiniert ist.
// (Dies sollte normalerweise nie passieren !)
// (1),(2): Das Result "ERROR_MESSAGE" enthaelt zusaetzliche Hinweise.
//
// (3) : EDIABAS_BIP_0010 / CONSTANT DATA ACCESS ERROR
// -> Dieser EDIABAS-Fehler tritt auf, wenn im Job eine Tabellen-
// Spalte, die in der SGBD benutzt wird, nicht existiert
// (z.B. bei fehlerhaft dimensionierten Tabellen).
// Es entsteht deshalb eine EDIABAS-Fehlermeldung, da die
// Ueberpruefung der Tabellen-Spalten erst zur Laufzeit
// geschieht.
// -------------------------------------------------------------------
// ACHTUNG: Es wird davon ausgegangen, dass in der SG-Antwort
// vor den 3 Bytes Fehlerort 1 Byte DTCSeverity kommt !
// -------------------------------------------------------------------
// History:
// 09.02.2006 gh V0.001 Erstellung
// 15.02.2006 gh V0.002 gestestet mit Simulation
// 16.02.2006 gh V0.003 Zuweisung "response1 = response;" integriert
// 20.02.2006 gh V0.004 Umbenennung F_UW_ZEIT_DATUM => F_UW_DATUM_ZEIT
// 22.02.2006 gh V0.005 Integration Subtabellen Tab_<Index>
// 23.02.2006 gh V0.005 Korrektur Variablendefinition: unsigned !
// 24.03.2006 gh V0.006 Zuweisung Result F_HEX_CODE integriert
// 24.03.2006 gh V0.006 Sonderf<72>lle 0xFFFFFF(FF) bei F_UW_KM / F_UW_DATUM_ZEIT
// 24.03.2006 gh V0.006 _RESPONSE_* auch bei Abbruch
// 27.03.2006 gh V0.007 Abbruch, wenn zu wenig Daten in SG-Antwort
// 28.03.2006 gh V0.007 Abbruch, wenn Anzahl der Daten in SG-Antwort falsch
// 23.06.2006 gh V0.008 Integration Severity-Byte
// 28.06.2006 gh V0.009 Result "F_UW_DATUM_ZEIT" entfernt
// 29.06.2006 gh V0.010 Results bzgl. Severity-Byte in Satz 1
// 15.11.2006 gh V0.011 Wegen $19 $04: Anzahl UWB-S<>tze einstellbar und
// gh V0.011 $19 $04: komplexe UWB: Ausgabe als Text (string)
// gh V0.011 sind folgende Variablen erforderlich: uw_satz_anzahl, uw_typ_text
// gh V0.011 da gemeinsame Sub-Includes fuer FS/IS benutzt werden!
// 22.03.2007 gh V0.012 Sonderfall "anzahl_snapshotRecord = 0" ohne Error "Division by Zero"
// 14.03.2008 gr V0.013 Variable LIHlzValid hinzu
// *******************************************************************
// UDS_22_20_00_IS_LESEN_DETAIL.B2S @(#)@ V0.013 @(#)@
// *******************************************************************
job ( name : IS_LESEN_DETAIL;
comment : sekund<6E>ren Fehlerspeicher lesen (Info-Meldungen / Ort und Art);
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $20 dataIdentifier;
comment : UDS : $00 alle Info-Meldungen;
comment : anschlie<69>end;
comment : UDS : $20 dataIdentifier;
comment : UDS : $nn Details zur Info-Meldung an der Position n;
comment : Modus: Default;
argument : F_CODE;
type : long;
defrslt : ;
comment : gewaehlter Infocode;
comment : Wenn dieser Parameter angegeben wird,;
comment : wird die Position automatisch ermittelt.;
comment : Es darf dann nicht argument F_POS angegeben werden;
argument : F_POS;
type : int;
defrslt : ;
comment : gewaehlter Eintrag;
comment : Wenn dieser Parameter angegeben wird,;
comment : wird die Position benutzt.;
comment : Wertebereich 1 - 255;
comment : Es darf dann nicht argument F_CODE angegeben werden;
result : F_VERSION;
type : int;
defrslt : 3;
comment : Typ des Fehlerspeichers;
comment : Fuer UDS immer 3;
result : F_HEX_CODE;
type : data;
comment : Fehlerdaten pro Fehler als Hexcode;
result : F_ORT_NR;
type : long;
comment : Index fuer Fehlerort;
result : F_ORT_TEXT;
type : string;
comment : Fehlerort als Text;
comment : table FOrtTexte ORTTEXT;
result : F_EREIGNIS_DTC;
type : int;
comment : 0: DTC kein Ereignis DTC;
comment : 1: DTC ist Ereignis DTC;
comment : table FOrtTexte EREIGNIS_DTC;
result : F_READY_NR;
type : int;
comment : Readyness Flag (Standard-Fehlerart) als Zahl;
result : F_READY_TEXT;
type : string;
comment : Readyness Flag (Standard-Fehlerart) als Text;
comment : table FArtTexte ARTTEXT;
result : F_VORHANDEN_NR;
type : int;
comment : Fehler vorhanden (Standard-Fehlerart) als Zahl;
result : F_VORHANDEN_TEXT;
type : string;
comment : Fehler vorhanden (Standard-Fehlerart) als Text;
comment : table FArtTexte ARTTEXT;
result : F_WARNUNG_NR;
type : int;
comment : Warnlampen Flag (Standard-Fehlerart) als Zahl;
result : F_WARNUNG_TEXT;
type : string;
comment : Warnlampen Flag (Standard-Fehlerart) als Text;
comment : table FArtTexte ARTTEXT;
result : F_HFK;
type : int;
comment : Haufigkeitszaehler als Zahl;
comment : Wertebereich 0 - 255;
comment : Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf;
result : F_HLZ;
type : int;
comment : Heilungsszaehler als Zahl;
comment : Wertebereich 0 - 255;
comment : -1: ohne Haufigkeitszaehler;
result : F_UEBERLAUF;
type : int;
comment : 0: Kein Ueberlauf des Fehlerspeichers;
comment : 1: Ueberlauf des Fehlerspeichers;
result : F_FEHLERKLASSE_NR;
type : int;
comment : 0: Keine Fehlerklasse verfuegbar;
comment : 1: Ueberpruefung bei naechstem Werkstattbesuch;
comment : 2: Ueberpruefung bei naechstem Halt;
comment : 4: Ueberpruefung sofort erforderlich !;
result : F_FEHLERKLASSE_TEXT;
type : string;
comment : Ausgabe der Fehlerklasse als Text;
comment : table Fehlerklasse TEXT;
result : F_UW_ANZ;
type : int;
comment : Anzahl der Umweltbedingungen;
comment : Je nach dieser Anzahl i (i = 1, 2, ...);
comment : existieren i mal folgende Results:;
comment : (long) F_UWi_NR Index der i. Umweltbedingung;
comment : (string) F_UWi_TEXT Text zur i. Umweltbedingung;
comment : (real) F_Uwi_WERT Wert der i. Umweltbedingung;
comment : (string) F_UWi_EINH Einheit der i. Umweltbedingung;
result : F_UW_KM;
type : long;
comment : Umweltbedingung Kilometerstand (3 Byte);
comment : Wertebereich: 0 - 16777215 km;
comment : -1, wenn Kilometerstand nicht zur Verfuegung steht;
result : F_UW_ZEIT;
type : long;
comment : Umweltbedingung Absolute Zeit (4 Byte);
comment : Genauigkeit: in Sekunden;
comment : -1, wenn Absolute Zeit nicht zur Verfuegung steht;
/*
result : F_UW_DATUM_ZEIT;
type : string;
comment : Umweltbedingung Absolute Zeit im Datumsformat DD.MM.YYYY hh:mm:ss;
comment : Beginn: 01.01.2000 00:00:00;
*/
result : F_SAE_CODE;
type : unsigned int;
comment : Wertebereich 0x000000 - 0xFFFFFF;
comment : externe Tabelle T_SCOD;
result : F_SAE_CODE_STRING;
type : string;
comment : 5 stelliger Text in der Form 'Sxxxx';
result : F_SAE_CODE_TEXT;
type : string;
comment : Text zu F_SAE_CODE;
result : _RESPONSE_2000;
type : data;
comment : Hex-Antwort von SG;
result : _RESPONSE_200X;
type : data;
comment : Hex-Antwort von SG;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
)
{
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
unsigned int LIStatusDTC = 0x00;
unsigned char temp[];
unsigned char text[];
unsigned char text1[];
unsigned char response1[];
long wert;
unsigned long code;
unsigned int offset;
unsigned int LILaengeData;
unsigned long LLData;
unsigned long zeit_aktuell;
// Variablen f<>r die Basis-Infos des DTC
int LIExtendedRecordNumber;
int LIUWErweitertExist;
int LIHlzExist;
int LIHlzValid;
int LISaeCodeExist;
int severity_exist;
unsigned char severity_byte;
/* // Variablen zur Zeitberechnung
unsigned int LIJahr;
unsigned int LIMonat;
unsigned int LITag;
unsigned int LIStunden;
unsigned int LIMinuten;
unsigned int LISekunden;
unsigned int LIAbbruch;
unsigned int LISchaltjahr;
*/
// Variablen fuer die Umweltsaetze
unsigned int LIIdentifier;
unsigned int LICounterUW;
unsigned int LIAnzUW;
//unsigned long LLAnzahlSnapshotIdentifier;
//unsigned int LISnapshotNumber;
//unsigned int LICounterIdentifier;
int uw_satz_anzahl;
unsigned int dtc_gefunden; // Flag, ob der Info-Eintrags (DTC) gefunden wurde
unsigned int dtc_pos; // Position des Info-Eintrags (DTC)
unsigned int is_anz; // Anzahl der Eintraege im Infospeicher
unsigned int laenge_ExtendedData; // L<>nge der Extended Data (2 oder 3 Byte)
unsigned int laenge_snapshotRecord; // L<>nge eines snapshot records
unsigned int anzahl_snapshotRecord; // Anzahl der snapshot records
unsigned int laenge_snapshot; // tempor<6F>re L<>nge eines snapshot records (Variable f<>r while-Schleife)
unsigned int pos_start; // Offset-Position beim Start der while-Schleife
unsigned int pos_ende; // Offset-Position beim Ende der while-Schleife
unsigned int uw_sub_index; // Index der Sub-UW
unsigned int uw_sub_anz; // Anzahl der Sub-UWs
unsigned int identifier_sub; // Identifier der Sub-UW
unsigned int offset_start; // Startwert bei Extended Data
unsigned int uw_laenge; // Laenge der einzelnen UW [Bytes]
unsigned char uw_gueltig; // Flag, ob UW gueltig d.h. "offset < daten_laenge"
unsigned long uw_mask; // Maske fuer digitale bzw. diskrete UW
unsigned long uw_wert_mask; // Puffer fuer F_UWn_WERT (Bitmaske: digital / diskret)
long uw_wert; // Puffer fuer F_UWn_WERT (long)
real uw_wert_real; // Puffer fuer F_UWn_WERT (real)
real uw_mul_real; // fuer Berechnung analoger UW
real uw_div_real; // fuer Berechnung analoger UW
real uw_add_real; // fuer Berechnung analoger UW
unsigned int daten_laenge; // "datalen(daten)" (kommt mehrfach vor)
unsigned int uw_typ; // ODER-Verknuefpung von UW-Typ-Flags
unsigned int uw_typ_digital = 0x0001; // Flag fuer digitale UW (Grundtyp / Zuweisung )
unsigned int uw_typ_diskret = 0x0002; // Flag fuer diskrete UW (Grundtyp / Zuweisung )
unsigned int uw_typ_analog = 0x0004; // Flag fuer analoge UW (long) (Grundtyp / Zuweisung )
unsigned int uw_typ_float = 0x0008; // Flag fuer analoge UW (real / float) (Zusatz / Veroderung)
unsigned int uw_typ_double = 0x0010; // Flag fuer analoge UW (real / double) (Zusatz / Veroderung)
unsigned int uw_typ_signed = 0x0020; // Flag fuer Vorzeichen der UW (unsigned / signed) (Zusatz / Veroderung)
unsigned int uw_typ_Motorola = 0x0040; // Flag fuer Prozessor (Intel / Motorola) (Zusatz / Veroderung)
unsigned int uw_typ_low_high = 0x0080; // Flag fuer Reihenfolge (high/low, low/high) (Zusatz / Veroderung)
unsigned int uw_typ_hex = 0x0100; // Flag fuer hexadezimale UW (1, 2, 4 Byte => string) (Grundtyp / Zuweisung )
unsigned int uw_typ_text = 0x0200; // Flag fuer UW als Text (string mit n Bytes) (Grundtyp / Zuweisung )
unsigned char request[] = {0x22,0x20,0x00};
// ---------------- Ueberpruefung ob Tabellen includiert sind --------
INCLUDE_UDS_TAB_IArtTexte_B2S_NOT_FOUND;
INCLUDE_UDS_TAB_DTCExtendedDataRecordNumber_B2S_NOT_FOUND;
INCLUDE_UDS_TAB_DTCSnapshotIdentifier_B2S_NOT_FOUND;
INCLUDE_UDS_TAB_Fehlerklasse_B2S_NOT_FOUND;
// ---------------- Argumente des Jobs auswerten ---------------------
if ((!exist(F_CODE)) && (!exist(F_POS)))
return_with_message("?F0?", "1 ARGUMENT NECESSARY - EITHER F_CODE OR F_POS", response, "", 0);
if (exist(F_CODE) && exist(F_POS))
return_with_message("?F0?", "ONLY 1 ARGUMENT ALLOWED - EITHER F_CODE OR F_POS", response, "", 0);
// ---------------- 1. Kommunikation (nur bei Argument F_CODE) -------
if (exist(F_CODE)) {
code = F_CODE;
dataclear(response);
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) {
if (_RESPONSE_2000) _RESPONSE_2000 = response;
return;
}
response1 = response; // zwischenpuffern, da erst am Ende des Jobs ben<65>tigt
// ---------------- 1. Interpretation (nur bei Argument F_CODE) ------
dtc_gefunden = 0; // Flag, ob der Info-Eintrags (DTC) gefunden wurde
dtc_pos = 1; // Position des Info-Eintrags (DTC)
is_anz = (datalen(response) - 3) / 4; // Anzahl der Eintraege im Infospeicher
offset = 3; // Startwert
while (is_anz > 0) {
if ((((response[offset] << 16) & 0x00FF0000) + ((response[offset+1] << 8) & 0x0000FF00) + response[offset+2]) == code) {
dtc_gefunden = 1;
break;
}
offset = offset + 4;
++dtc_pos;
--is_anz;
}
if (dtc_gefunden == 0) // Abbruch, wenn Info-Eintrag nicht vorkommt
return_with_message("?10?", "ERROR-CODE NOT STORED IN SHADOW-MEMORY", response, "_RESPONSE_2000", 0);
}
// ---------------- Position direkt (nur bei Argument F_POS) ---------
if (exist(F_POS)) {
dtc_pos = F_POS; // Position des Info-Eintrags (DTC)
if ((dtc_pos < 0x01) || (dtc_pos > 0x1FF)) {
JOB_STATUS = "ERROR_F_POS";
return;
}
}
// ---------------- 2. Kommunikation (immer !) -----------------------
dataclear(response);
request[2] = dtc_pos; // DTC-Position
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) {
if (_RESPONSE_2000) _RESPONSE_2000 = response1;
if (_RESPONSE_200X) _RESPONSE_200X = response;
return;
}
// ................ Zuweisung F_HEX_CODE .............................
if (F_HEX_CODE) {
text = response; // Snapshots + Extended Data
dataerase(text, 0, 3);
F_HEX_CODE = text;
}
// ---------------- 2. Interpretation --------------------------------
// ................ Test Fehlercode (nur bei Argument F_CODE) ........
if (exist(F_CODE)) {
if (code != ((response[4] << 16) + (response[5] << 8) + response[6])) {
if (_RESPONSE_2000) _RESPONSE_2000 = response1;
return_with_message("?10?", "ERROR-CODE RESPONSE IS NOT ERROR-CODE REQUEST", response, "_RESPONSE_200X", 0);
}
}
// ................ Test Fehlerposition (nur bei Argument F_POS) .....
if (exist(F_POS)) {
if (dtc_pos != response[2]) {
if (_RESPONSE_2000) _RESPONSE_2000 = response1;
return_with_message("?13?", "POSITION RESPONSE IS NOT POSITION REQUEST", response, "_RESPONSE_200X", 0);
}
code = (response[4] << 16) + (response[5] << 8) + response[6]; // Fehlercode aus SG-Antwort !
}
// ---------------- Auswertung XDetailStruktur -----------------------
#define DetailStruktur "IDetailStruktur"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_FS_DetailStruktur.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : FS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, FOrtTexte, FArtTexte, FDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// FUmweltTexte
// -------------------------------------------------------------------
// Jobname : IS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, IOrtTexte, IArtTexte, IDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// IUmweltTexte
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// -------------------------------------------------------------------
// Hinweise allgemein:
// (1) : JOB_STATUS = "ERROR_TABLE"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// erkannt wird, dass eine Tabelle falsch befuellt ist.
// (2) : JOB_STATUS = "ERROR_INTERPRETATION"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// ein Fall auftritt, der undefiniert ist.
// (Dies sollte normalerweise nie passieren !)
// (1),(2): Das Result "ERROR_MESSAGE" enthaelt zusaetzliche Hinweise.
//
// (3) : EDIABAS_BIP_0010 / CONSTANT DATA ACCESS ERROR
// -> Dieser EDIABAS-Fehler tritt auf, wenn im Job eine Tabellen-
// Spalte, die in der SGBD benutzt wird, nicht existiert
// (z.B. bei fehlerhaft dimensionierten Tabellen).
// Es entsteht deshalb eine EDIABAS-Fehlermeldung, da die
// Ueberpruefung der Tabellen-Spalten erst zur Laufzeit
// geschieht.
// -------------------------------------------------------------------
// History:
// 09.02.2006 gh V0.001 Erstellung
// 15.02.2006 gh V0.002 getestet mit Simulation
// 23.06.2006 gh V0.003 Integration Flag "severity_exist"
// 29.06.2006 gh V0.004 Fehlerbehandlung Flags
// 18.10.2006 gh V0.020 neues Konfigurationselement: F_UWB_SATZ
// 14.03.2007 gr V0.021 neues Konfigurationselement: F_HLZ_VIEW
// *******************************************************************
// UDS_FS_DetailStruktur.B2S @(#)@ V0.021 @(#)@
// *******************************************************************
// ---------------- Auswertung XDetailStruktur -----------------------
tabset(DetailStruktur); // Tabelle nicht vorhanden muss noch abgefangen werden (bei Generator immer vorhanden!)
// ................ Auswertung Umweltbedingungen erweitert ...........
if (tabseek("NAME", "F_UWB_ERW")) {
tabget(temp, "TYP");
temp[0] = temp[0] | 0x20; // erstes Zeichen in Kleinschrift
if (temp[0] == 0x6E) // Handelt es sich bei dem ersten Zeichen um ein "n" ?
LIUWErweitertExist = 0;
else
LIUWErweitertExist = 1;
}
else
LIUWErweitertExist = 0;
// ................ Auswertung Umweltbedingungs-S<>tze ................
if (tabseek("NAME", "F_UWB_SATZ")) {
tabget(temp, "TYP");
uw_satz_anzahl = atoi(temp);
}
else
uw_satz_anzahl = 2;
// ................ Auswertung SAE-Codes .............................
dataclear(temp);
if (tabseek("NAME", "F_SAE_CODE")) {
tabget(temp, "TYP");
temp[0] = temp[0] | 0x20; // erstes Zeichen in Kleinschrift
if (temp[0] == 0x6E) // Handelt es sich bei dem ersten Zeichen um ein "n" ?
LISaeCodeExist = 0;
else
LISaeCodeExist = 1;
}
else
LISaeCodeExist = 0;
// ................ Auswertung Heilungsz<73>hler ........................
dataclear(temp);
if (tabseek("NAME", "F_HLZ")) {
tabget(temp, "TYP");
temp[0] = temp[0] | 0x20; // erstes Zeichen in Kleinschrift
if (temp[0] == 0x6E) { // Handelt es sich bei dem ersten Zeichen um ein "n" ?
LIHlzExist = 0;
if (F_HLZ)
F_HLZ = -1;
}
else
LIHlzExist = 1;
}
else
LIHlzExist = 0;
// ................ Auswertung Severity-Byte .........................
dataclear(temp);
if (tabseek("NAME", "F_SEVERITY")) {
tabget(temp, "TYP");
temp[0] = temp[0] | 0x20; // erstes Zeichen in Kleinschrift
if (temp[0] == 0x6E) // Handelt es sich bei dem ersten Zeichen um ein "n" ?
severity_exist = 0;
else
severity_exist = 1;
}
else
severity_exist = 0;
// ................ Auswertung Heilungsz<73>hler g<>ltig .........................
// Parameter ist solange erfoderlich, bis das Problem mit dem HLZ im Standard-Core gel<65>st ist
dataclear(temp);
if (tabseek("NAME", "F_HLZ_VIEW")) {
tabget(temp, "TYP");
if (temp[0] == 0x2D) // Handelt es sich bei diesem Zeichen um ein '-'?
LIHlzValid = 1; // Wenn nichts angebenen wird, dann richtet sich die Auswertung allein nach F_HLZ
else
{
temp[0] = temp[0] | 0x20; // erstes Zeichen in Kleinschrift
if (temp[0] == 0x6E) // Handelt es sich bei dem ersten Zeichen um ein "n" ?
LIHlzValid = 0;
else
LIHlzValid = 1;
}
}
else
LIHlzValid = 1; // Wenn nichts angebenen wird, dann richtet sich die Auswertung allein nach F_HLZ
// End of file
// end of : #include "UDS_FS_DetailStruktur.b2s"
#undef DetailStruktur
// ---------------- Auswertung Severity-Byte -------------------------
if (severity_exist)
severity_byte = (response[3] >> 5) & 0x07; // Es werden nur die obersten 3 Bit ben<65>tigt.
else
severity_byte = 0; // There is no severity information available.
if (F_FEHLERKLASSE_NR)
F_FEHLERKLASSE_NR = severity_byte;
if (F_FEHLERKLASSE_TEXT) {
tabset("Fehlerklasse");
tab_suche_unsigned("NR", severity_byte);
tabget(text,"TEXT");
F_FEHLERKLASSE_TEXT = text;
}
// ---------------- Zuweisung F-Ort, F-Arten -----------------------
offset = 7; // Startpunkt: Byte "statusOfDTC"
#define OrtTexte "IOrtTexte"
#define ArtTexte "IArtTexte"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_FS_Ort_Art.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : FS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, FOrtTexte, FArtTexte, FDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// FUmweltTexte
// -------------------------------------------------------------------
// Jobname : IS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, IOrtTexte, IArtTexte, IDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// IUmweltTexte
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// -------------------------------------------------------------------
// Hinweise allgemein:
// (1) : JOB_STATUS = "ERROR_TABLE"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// erkannt wird, dass eine Tabelle falsch befuellt ist.
// (2) : JOB_STATUS = "ERROR_INTERPRETATION"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// ein Fall auftritt, der undefiniert ist.
// (Dies sollte normalerweise nie passieren !)
// (1),(2): Das Result "ERROR_MESSAGE" enthaelt zusaetzliche Hinweise.
//
// (3) : EDIABAS_BIP_0010 / CONSTANT DATA ACCESS ERROR
// -> Dieser EDIABAS-Fehler tritt auf, wenn im Job eine Tabellen-
// Spalte, die in der SGBD benutzt wird, nicht existiert
// (z.B. bei fehlerhaft dimensionierten Tabellen).
// Es entsteht deshalb eine EDIABAS-Fehlermeldung, da die
// Ueberpruefung der Tabellen-Spalten erst zur Laufzeit
// geschieht.
// -------------------------------------------------------------------
// History:
// 09.02.2006 gh V0.001 Erstellung
// 15.02.2006 gh V0.002 getestet mit Simulation
// 16.02.2006 gh V0.003 Zuweisung "response1 = response;" entfernt
// 24.03.2006 gh V0.004 Zuweisung Result F_HEX_CODE entfernt
// *******************************************************************
// UDS_FS_Ort_Art.B2S @(#)@ V0.004 @(#)@
// *******************************************************************
// ................ R<>ckgabe buffer l<>schen ..........................
dataclear(temp);
dataclear(text);
dataclear(text1);
// ................ R<>ckgabe Basis-Infos .............................
LIStatusDTC = response[offset] & 0x4D; // Auslesen des Status Bytes. F<>r die Auswertung sind die Bits 0,2,3,6 entscheidend
if (F_ORT_NR || F_ORT_TEXT || F_EREIGNIS_DTC || F_READY_NR || F_READY_TEXT || F_VORHANDEN_NR || F_VORHANDEN_TEXT || F_WARNUNG_NR || F_WARNUNG_TEXT) {
dataclear(temp);
F_ORT_NR = code; // Ausgabe Fehlerort
tabset(OrtTexte); // Dazugehoeriger Fehlertext
tab_suche_unsigned("ORT", code);
tabget(temp, "ORTTEXT");
F_ORT_TEXT = temp;
tabget(temp, "EREIGNIS_DTC"); // Ereignis-DTC ja / nein
F_EREIGNIS_DTC = atoi(temp);
wert = ((response[offset] >> 4) & 0x01) + 0x10; // Gibt an, ob Test seit dem letzten L<>schen einmal komplett durchlaufen wurde
F_READY_NR = wert; // Offset 0x10 wird addiert, um Tabelle FArtTexte verwenden zu k<>nnen
tabset(ArtTexte);
tab_suche_unsigned("ARTNR", wert);
tabget(text, "ARTTEXT");
F_READY_TEXT = text;
F_VORHANDEN_NR = LIStatusDTC; // Fehler aktuell vorhanden? (siehe Matrix in XArtTexte)
tab_suche_unsigned("ARTNR", LIStatusDTC);
tabget(text, "ARTTEXT");
F_VORHANDEN_TEXT = text;
wert = ((response[offset] >> 7) & 0x01) + 0x80; // Geht eine Warnlampe an oder nicht
F_WARNUNG_NR = wert;
tab_suche_unsigned("ARTNR", wert);
tabget(text, "ARTTEXT");
F_WARNUNG_TEXT = text;
}
// end of : #include "UDS_FS_Ort_Art.b2s"
#undef OrtTexte
#undef ArtTexte
// ---------------- Auswertung L<>ngen --------------------------------
daten_laenge = datalen(response);
// ................ L<>nge Extended Data bestimmen ....................
if (LIHlzExist == 1)
laenge_ExtendedData = 6; // 2 mal 3 (RN EX RN EX RN EX)
else
laenge_ExtendedData = 4; // 2 mal 2 (RN EX RN EX)
// ................ L<>nge SnapshotRecord bestimmen ...................
anzahl_snapshotRecord = response[8]; // DTCSnapshotRecordCount aus SG-Antwort
if (anzahl_snapshotRecord == 0) {
new_set_of_results();
if (_RESPONSE_2000) _RESPONSE_2000 = response1;
return_with_message("?08?", "TOO LESS DATA IN RESPONSE-TELEGRAM", response,"_RESPONSE_200X", 0);
}
else
laenge_snapshotRecord = (datalen(response) - 9 - laenge_ExtendedData) / anzahl_snapshotRecord;
// ---------------- Abbruch, wenn zu wenig Daten in SG-Antwort -------
if (laenge_snapshotRecord < 11) { // 2 Byte ID + 3 Byte KM / 2 Byte ID + 4 Byte Zeit
new_set_of_results();
if (_RESPONSE_2000) _RESPONSE_2000 = response1;
return_with_message("?12?", "OBLIGATORY SNAPSHOTS (MILAGE / TIME) ARE MISSING", response,"_RESPONSE_200X", 0);
}
// ---------------- Auswertung Extended Data -------------------------
offset = 9 + (anzahl_snapshotRecord * laenge_snapshotRecord);
offset_start = offset;
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_FS_Extended_Data.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : FS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, FOrtTexte, FArtTexte, FDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// FUmweltTexte
// -------------------------------------------------------------------
// Jobname : IS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, IOrtTexte, IArtTexte, IDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// IUmweltTexte
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// -------------------------------------------------------------------
// Hinweise allgemein:
// (1) : JOB_STATUS = "ERROR_TABLE"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// erkannt wird, dass eine Tabelle falsch befuellt ist.
// (2) : JOB_STATUS = "ERROR_INTERPRETATION"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// ein Fall auftritt, der undefiniert ist.
// (Dies sollte normalerweise nie passieren !)
// (1),(2): Das Result "ERROR_MESSAGE" enthaelt zusaetzliche Hinweise.
//
// (3) : EDIABAS_BIP_0010 / CONSTANT DATA ACCESS ERROR
// -> Dieser EDIABAS-Fehler tritt auf, wenn im Job eine Tabellen-
// Spalte, die in der SGBD benutzt wird, nicht existiert
// (z.B. bei fehlerhaft dimensionierten Tabellen).
// Es entsteht deshalb eine EDIABAS-Fehlermeldung, da die
// Ueberpruefung der Tabellen-Spalten erst zur Laufzeit
// geschieht.
// -------------------------------------------------------------------
// History:
// 09.02.2006 gh V0.001 Erstellung
// 15.02.2006 gh V0.002 getestet mit Simulation
// 20.02.2006 gh V0.003 Entfernung "new_set_of_results();"
// 14.03.2008 gr V0.004 Abfrage, ob Heilungsz<73>hler angezeigt werden soll
// *******************************************************************
// UDS_FS_Extended_Data.B2S @(#)@ V0.004 @(#)@
// *******************************************************************
// ................ Solange noch Eintr<74>ge vorhanden sind .............
while (offset < (datalen(response))) {
LIExtendedRecordNumber = response[offset];
tabset("DTCExtendedDataRecordNumber");
tab_suche_unsigned("WERT", LIExtendedRecordNumber);
tabget(temp, "ANZ_BYTE");
LILaengeData = atoi(temp);
LLData = 0;
while (LILaengeData > 0) { // Anzahl der Bytes
offset = offset + 1;
LLData = LLData + (response[offset] << ((LILaengeData - 1) * 8));
LILaengeData--;
}
if (LIExtendedRecordNumber == 0x01) { // Condition-Byte ist Pflicht
if (F_UEBERLAUF)
F_UEBERLAUF = LLData & 0x01;
}
if (LIExtendedRecordNumber == 0x02) { // Haeufigkeitszaehler ist Pflicht
if (F_HFK)
F_HFK = LLData;
}
if ((LIExtendedRecordNumber == 0x03) && (LIHlzExist == 1) && (LIHlzValid == 1)) { // Heilungsz<73>hler (optional)
if (F_HLZ)
F_HLZ = LLData;
}
offset = offset + 1;
}
// end of : #include "UDS_FS_Extended_Data.b2s"
// Abfrage, nach LIHlzValid darf nicht gemacht werden, da sonst Telegramml<6D>nge nicht mehr stimmt.
if (((LIHlzExist == 1) && ((datalen(response) - offset_start) != 6)) ||
((LIHlzExist != 1) && ((datalen(response) - offset_start) != 4))) {
new_set_of_results();
if (_RESPONSE_2000) _RESPONSE_2000 = response1;
return_with_message("?12?", "INCORRECT NUMBER OF DATA IN RESPONSE-TELEGRAM", response,"_RESPONSE_200X", 0);
}
// ---------------- Auswertung Snapshots -----------------------------
offset = 9; // Startpunkt: High-Byte des dataIdentifier (DID)
while (anzahl_snapshotRecord > 0) {
LIAnzUW = 0; // Anzahl der zusaetzlichen Umweltbedingungen zuruecksetzen
LICounterUW = 1; // Z<>hler der Umweltbedingungen zur<75>ck setzen
uw_gueltig = 1;
laenge_snapshot = laenge_snapshotRecord;
while (laenge_snapshot > 0) {
pos_start = offset;
#define UmweltTexte "IUmweltTexte"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_FS_Snapshot.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : FS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, FOrtTexte, FArtTexte, FDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// FUmweltTexte
// -------------------------------------------------------------------
// Jobname : IS_LESEN_DETAIL
// -------------------------------------------------------------------
// Globale Tabellen : JobResult, IOrtTexte, IArtTexte, IDetailStruktur
// DTCExtendedDataRecordNumber,
// DTCSnapshotIdentifier
//
// Optionale Tabelle bei SAE-Codes
// SAECodeTexte
//
// Optionale Tabelle bei zusaetzlichen Umweltbedingungen
// IUmweltTexte
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// -------------------------------------------------------------------
// Hinweise allgemein:
// (1) : JOB_STATUS = "ERROR_TABLE"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// erkannt wird, dass eine Tabelle falsch befuellt ist.
// (2) : JOB_STATUS = "ERROR_INTERPRETATION"
// -> Dieser Fehler wird gemeldet, wenn bei der Job-Bearbeitung
// ein Fall auftritt, der undefiniert ist.
// (Dies sollte normalerweise nie passieren !)
// (1),(2): Das Result "ERROR_MESSAGE" enthaelt zusaetzliche Hinweise.
//
// (3) : EDIABAS_BIP_0010 / CONSTANT DATA ACCESS ERROR
// -> Dieser EDIABAS-Fehler tritt auf, wenn im Job eine Tabellen-
// Spalte, die in der SGBD benutzt wird, nicht existiert
// (z.B. bei fehlerhaft dimensionierten Tabellen).
// Es entsteht deshalb eine EDIABAS-Fehlermeldung, da die
// Ueberpruefung der Tabellen-Spalten erst zur Laufzeit
// geschieht.
// -------------------------------------------------------------------
// History:
// 09.02.2006 gh V0.001 Erstellung
// 15.02.2006 gh V0.002 getestet mit Simulation
// 20.02.2006 gh V0.003 Umbenennung F_UW_ZEIT_DATUM => F_UW_DATUM_ZEIT
// 22.02.2006 gh V0.004 Integration Subtabellen Tab_<Index>
// 24.03.2006 gh V0.005 Sonderfall 0xFFFFFF bei F_UW_KM
// 24.03.2006 gh V0.005 Sonderfall 0xFFFFFFFF bei F_UW_DATUM_ZEIT
// 24.03.2006 gh V0.005 Korrektur Schaltjahrberechnung
// 27.03.2006 gh V0.006 diskrete UW: real bei F_UWi_WERT, zusammengesetzter Text bei F_UWi_TEXT
// 27.03.2006 gh V0.006 Format bei F_UW_DATUM_ZEIT optimiert
// 29.03.2006 gh V0.006 Trace-Meldungen bzgl. return_with_message optimiert
// 28.06.2006 gh V0.007 Zuweisung Result "F_UW_DATUM_ZEIT" auskommentiert
// 19.10.2006 gh V0.020 $19 $04: komplexe UWB: Ausgabe als Text (string)
// 03.12.2007 rd V0.021 Bug behoben bei hex, text Abfrage
// 21.02.2008 gr V0.022 Auskommentierten Teil F_UW_DATUM_ZEIT entfernt
// 21.02.2008 gr V0.022 Bei SAE-Codes von Tabelle T_SCOD auf Tabelle T_PCOD umgestellt
// 21.02.2008 gr V0.022 Bei SAE-Codes werden nur die ersten beiden Byte verwendet
// 21.02.2008 gr V0.022 Zus<75>tzliche Eintr<74>ge der Tabelle DTCSnapshotIdentifier m<>glich
// 12.03.2010 gh V0.030 Sub-Tabellen f<>r diskrete UW: Spaltenname "UWTEXT" oder "TEXT" m<>glich
// *******************************************************************
// UDS_FS_Snapshot.B2S @(#)@ V0.030 @(#)@
// *******************************************************************
uw_laenge = 0; // Laenge der Umweltbedingung zuruecksetzen
uw_typ = 0x00;
LIIdentifier = (response[offset] << 8) + response[offset+1];
offset = offset + 2; // bei digitaler oder diskreter UW nicht grunds<64>tzlich weiterschalten !!!
// Einlesen des Identifier
tabset("DTCSnapshotIdentifier");
if (tab_suche_unsigned("UWNR", LIIdentifier) == 0) { // Falls der Identifier nicht in der Standard-UW-Tabelle enthalten ist, muss die spezielle Tabelle ausgewertet werden
if (LIUWErweitertExist == 1) {
tabset(UmweltTexte);
if (tab_suche_unsigned("UWNR", LIIdentifier) == 0) { // Falls der Identifier auch nicht in der speziellen UW-Tabelle enthalten ist => Fehler
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?12?", "IDENTIFIER NOT DEFINED", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?12?", "IDENTIFIER NOT DEFINED", response,"_RESPONSE_200X", 0);
}
}
}
else {
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?12?", "IDENTIFIER NOT DEFINED", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?12?", "IDENTIFIER NOT DEFINED", response,"_RESPONSE_200X", 0);
}
}
} // Ende 'if (tab_suche_unsigned("UWNR", LIIdentifier) == 0)'
// ... Standard-Identifier (KM, Zeit, SAE-Code) ......................
if (LIIdentifier == 0x1700 || LIIdentifier == 0x1701 || LIIdentifier == 0x1702) {
if (LIIdentifier == 0x1700) { // KM-Stand
uw_laenge = 3;
LLData = (response[offset] << 16) + (response[offset+1] << 8) + (response[offset+2]);
if (LLData == 0xFFFFFF) // Bei 0xFFFFFF steht der KM-Stand nicht zur Verf<72>gung.
LLData = -1; // Hier soll analog zu F_UW_ZEIT der Wert -1 kommen.
if (F_UW_KM)
var_result_long("F_UW_KM", LLData);
}
// Auswertung des Datensatzes
if (LIIdentifier == 0x1701) { // Absolute Zeit
uw_laenge = 4;
LLData = (response[offset] << 24) + (response[offset+1] << 16) + (response[offset+2] << 8) + (response[offset+3]); // Angabe der Zeit seit 01.01.2000
zeit_aktuell = LLData;
if (F_UW_ZEIT)
var_result_long("F_UW_ZEIT", zeit_aktuell);
} // Ende 'if (LIIdentifier == 0x1701)'
// Auswertung des Datensatzes
if (LIIdentifier == 0x1702) { // SAE-Code
uw_laenge = 3;
// alte Zuordnung
// LLData = (response[offset] << 16) + (response[offset+1] << 8) + (response[offset+2]);
// Bei den SAE-Codes werden doch nur die ersten beiden Bytes belegt
// Da ein 3-Byte-Wert geliefert wird, wird das letzte Byte abgeschnitten
LLData = (response[offset] << 8) + response[offset+1];
if (F_SAE_CODE)
F_SAE_CODE = LLData;
tabsetext("T_PCOD","PCodeTexte");
tab_suche_unsigned("PCODE", LLData);
if (F_SAE_CODE_STRING) {
tabget(text, "STRING");
F_SAE_CODE_STRING = text;
}
if (F_SAE_CODE_TEXT) {
tabget(text, "TEXT");
F_SAE_CODE_TEXT = text;
}
}
} // Ende IF-Zweig 'if (LIIdentifier == 0x1700 || LIIdentifier == 0x1701 || LIIdentifier == 0x1703)'
// ... SG-spezifischer Identifier ....................................
else {
uw_sub_index = 0;
// . . f<>r alle Sub-Identifier . . . . . . . . . . . . . . . . . . . .
do {
// . . nur beim ersten Mal . . . . . . . . . . . . . . . . . . . . . .
if (uw_sub_index == 0) {
identifier_sub = LIIdentifier;
set_trap_mask(0x0400); // Trap-Bit f<>r Tabellenzugriff setzen
strcpy(text, "Tab_");
itoax(temp, identifier_sub);
dataerase(temp, 2, 4);
strcat(text, temp);
tabset(text); // Erweiterungsmatrix <20>ffnen
set_trap_mask(0); // Trap-Bit f<>r Tabellenzugriff ruecksetzen
if (get_error(10)) { // Sub-Tabelle existiert nicht
uw_sub_index = 0; // keine Aktion
}
else { // Sub-Tabelle existiert
++uw_sub_index; // 1. Wert: uw_sub_index = 1;
tabline(0);
tabget(text1, "UW_ANZ");
uw_sub_anz = atoi(text1);
}
}
// . . ab dem ersten Mal . . . . . . . . . . . . . . . . . . . . . . .
if (uw_sub_index > 0) {
if (uw_sub_index <= uw_sub_anz) { // Suchen in Zusatz-Matrix
strcpy(text, "Tab_");
itoax(temp, identifier_sub);
dataerase(temp, 2, 4);
strcat(text, temp);
tabset(text); // Erweiterungsmatrix <20>ffnen
tabline(0);
itoad(temp, uw_sub_index);
strinsert(temp, "UW", 0);
strcat(temp, "_NR");
tab2fix(LIIdentifier, temp); // neue "uw_nr" aus Zusatz-Matrix
if (uw_sub_index == uw_sub_anz) { // ! letzter digit./diskr. Wert
// ++uw_sub_anz;
uw_sub_index = 0;
}
else // sonst: weiterschalten !
++uw_sub_index;
}
else { // !!! darf eigentlich nie vorkommen
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?12?", "INCREMENT (++uw_sub_index)", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?12?", "INCREMENT (++uw_sub_index)", response,"_RESPONSE_200X", 0);
}
}
}
// . . UW normal abarbeiten . . . . . . . . . . . . . . . . . . . . .
LIAnzUW++; // Anzahl der echten UW-Bedingungen hochzaehlen
text = "F_UW";
itoad(text1, LIAnzUW);
strinsert(text1, text , 0);
// Es wird zuerst die Standard-Tabelle durchsucht
tabset("DTCSnapshotIdentifier");
if (tab_suche_unsigned("UWNR", LIIdentifier) == 0)
tabset(UmweltTexte); // Wenn in der Standard-Tabelle der Eintrag nicht enthalten ist, dann wird auf die spezifische UW-Daten gegangen
tab_suche_unsigned("UWNR", LIIdentifier); // (wieder) in die richtige Zeile springen
tabget(text, "UW_EINH"); // !!! >> "text" wird noch gebraucht (F_UWn_EINH)
if (!strcmp(text, "0/1"))
uw_typ = uw_typ_digital; // ! Typ -> digital
else if (!strcmp(text, "0-n"))
uw_typ = uw_typ_diskret; // ! Typ -> diskret
else {
temp = text;
temp[0] = temp[0] | 0x20; // ! Kleinschrift (1. Zeichen) h t
temp[1] = temp[1] | 0x20; // ! Kleinschrift (2. Zeichen) e e
temp[2] = temp[2] | 0x20; // ! Kleinschrift (3. Zeichen) x x
if (temp[3] != 0x00) // V0.021
temp[3] = temp[3] | 0x20; // ! Kleinschrift (4. Zeichen) \0 t
if (!strcmp(temp, "hex"))
uw_typ = uw_typ_hex; // ! Typ -> hex (neu)
else if (!strcmp(temp, "text"))
uw_typ = uw_typ_text; // ! Typ -> text (neu)
else
uw_typ = uw_typ_analog; // ! Typ -> analog (evtl. -> real (siehe unten))
} // Ende ELSE-Zweig !strcmp(text
// . . Zuweisung Result "F_UWn_NR" . . . . . . . . . . . . . . . . . .
temp = text1;
strcat(temp, "_NR");
var_result_long(temp, LIIdentifier);
// . . Zuweisung Result "F_UWn_TEXT" . . . . . . . . . . . . . . . . .
/***
tabget(text, "UWTEXT");
temp = text1;
strcat(temp, "_TEXT");
var_result_string(temp, text);
***/
// . . Zuweisung Result "F_UWn_EINH" . . . . . . . . . . . . . . . . .
tabget(text, "UW_EINH");
temp = text1;
strcat(temp, "_EINH");
var_result_string(temp, text);
// . . Aufschluesselung des Types um die Laenge der UW zu ermitteln
tabget(text, "UWTYP");
if ((uw_typ & uw_typ_analog) || (uw_typ & uw_typ_hex)) {
get_token(temp, text, " ", 1);
temp[0] = temp[0] | 0x20; // ! immer Kleinschrift
if (temp[0] == 's') // unsigned / signed
uw_typ = uw_typ | uw_typ_signed; // ! hier : "ODER"
if (temp[0] == 'm') // Intel / Motorola
uw_typ = uw_typ | uw_typ_Motorola; // ! hier : "ODER"
// . . Feststellen der Art der UW (3) Datentyp -> "uw_laenge" . . . .
get_token(temp, text, " ", 2);
temp[0] = temp[0] | 0x20; // ! immer Kleinschrift
if (temp[0] == 'c') // char
uw_laenge = 1;
else if (temp[0] == 'i') // int
uw_laenge = 2;
else if (temp[0] == 'l') // long
uw_laenge = 4;
else if (temp[0] == 'f') { // float
uw_laenge = 4;
uw_typ = uw_typ | uw_typ_float; // ! Typ -> float (! hier : "ODER")
}
else if (temp[0] == 'd') { // double
uw_laenge = 8;
uw_typ = uw_typ | uw_typ_double; // ! Typ -> double (! hier : "ODER")
}
else { // ! Default: FEHLER
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?0A?", "NOT DEFINED TYPE (use: char, int, long, float, double)", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?0A?", "NOT DEFINED TYPE (use: char, int, long, float, double)", response,"_RESPONSE_200X", 0);
}
}
}
else if (uw_typ & uw_typ_text)
uw_laenge = atoi(text); // Fehlerbehandlung ?
else if ((uw_typ & uw_typ_digital) || (uw_typ & uw_typ_diskret))
uw_laenge = (strlen(text) - 2) / 2;
// z.B.: 0x4321 => 1.) strlen()-2=4 (ohne "0x")
// 2.) 4 /2=2 (2 Hex-Ziffern pro Byte)
// else FEHLERMELDUNG
// ---------------------------------
// Zuweisung WERT
// . . Puffer f<>r Ergebnis zuweisen (uw_wert_real, uw_wert_mask, uw_wert, ...)
if (uw_gueltig == 1) { //Nur bei gueltiger UW
if ((uw_typ & uw_typ_float) || (uw_typ & uw_typ_double)) // analoger Wert (real)
data_to_real(uw_wert_real, response, offset, uw_laenge-4, uw_typ & uw_typ_Motorola);
else if (uw_typ & uw_typ_text) { // string mit n Bytes
tabget(temp, "L/H"); // Auswertung Byte-Order
temp[0] = temp[0] | 0x20; // ! immer Kleinschrift
if (temp[0] == 'l')
uw_typ = uw_typ | uw_typ_low_high; // ! hier : "ODER"
}
else { // Analogwert (long) oder digitaler/diskreter Wert . . . . . .
tabget(temp, "L/H"); // Auswertung Byte-Order
temp[0] = temp[0] | 0x20; // ! immer Kleinschrift
if (temp[0] == 'l')
uw_typ = uw_typ | uw_typ_low_high; // ! hier : "ODER"
switch (uw_laenge) {
case 4: // signed long / ! unsigned long NICHT moeglich
// Sonderfall: Fuer Bitmasken unsigned erforderlich falls das hoechste Bit gesetzt ist
if ((uw_typ & uw_typ_digital) || (uw_typ & uw_typ_diskret)) {
if (uw_typ & uw_typ_low_high) // low / middle_l / middle_h / high
uw_wert_mask = response[offset]+ (response[offset+1] << 8) + (response[offset+2] << 16) + (response[offset+3] << 24);
else // high / middle_h / middle_l / low
uw_wert_mask = (response[offset] << 24) + (response[offset+1] << 16) + (response[offset+2] << 8) + response[offset+3];
}
else { // Normalfall: analoger Wert (signed)
if (uw_typ & uw_typ_low_high) // low / middle_l / middle_h / high
uw_wert = response[offset] + (response[offset+1] << 8) + (response[offset+2] << 16) + (response[offset+3] << 24);
else // high / middle_h / middle_l / low
uw_wert = (response[offset] << 24) + (response[offset+1] << 16) + (response[offset+2] << 8) + response[offset+3];
}
break;
case 2: // unsigned int
if (uw_typ & uw_typ_low_high) // low / high
uw_wert = response[offset] + (response[offset+1] << 8);
else
uw_wert = (response[offset ] << 8) + response[offset+1];
if (uw_typ & uw_typ_signed) { // -> signed
if (uw_wert > 32767)
uw_wert = uw_wert - 65536;
}
uw_wert_mask = uw_wert; // bei int kein Unterschied
break;
case 1: // unsigned char
uw_wert = response[offset];
if (uw_typ & uw_typ_signed) { // -> signed
if (uw_wert > 127)
uw_wert = uw_wert - 256;
}
uw_wert_mask = uw_wert; // bei char kein Unterschied
break;
default: // ! Default: FEHLER
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?0A?", "LENGTH (BYTES) OF ENVIRONMENT CONDITION NOT ALLOWED", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?0A?", "LENGTH (BYTES) OF ENVIRONMENT CONDITION NOT ALLOWED", response,"_RESPONSE_200X", 0);
}
} // Ende 'switch (uw_laenge)'
} // Ende else Zweig von 'if ((uw_typ & uw_typ_float) || (uw_typ & uw_typ_double))'
// . . 1. Fall: digitale UW . . . . . . . . . . . . . . . . . . . . .
if (uw_typ & uw_typ_digital) {
tabget(temp, "UWTYP");
if (uw_laenge == 4) { // ! Ein Wert vom Typ "unsigned long" kann !
text = temp; // ! mit "atoi" nicht direkt interpretiert werden !
strerase(temp, 6, 4); // ! -> (1) Aufteilung in 2 "int"-Werte !
uw_mask = atoi(temp) & 0xFFFF;// ! -> (2) anschliessend zusammensetzen !
uw_mask = uw_mask << 16;
strerase(text, 2, 4);
uw_mask = uw_mask | (atoi(text) & 0xFFFF);
}
else // Normalfall: direkte Wandlung
uw_mask = atoi(temp);
if ((uw_wert_mask & uw_mask) == uw_mask)
uw_wert = 1;
else
uw_wert = 0;
itor(uw_wert_real, uw_wert); // -> real
} // Ende 'if (uw_typ & uw_typ_digital)'
// . . 2. Fall: diskrete UW . . . . . . . . . . . . . . . . . . . . .
else if (uw_typ & uw_typ_diskret) {
// ! tab2fix(uw_mask, "UWTYP"); // ! funktioniert nicht fuer hoechstes Bit
tabget(temp, "UWTYP");
if (uw_laenge == 4) { // ! Ein Wert vom Typ "unsigned long" kann !
strerase(temp, 6, 4); // ! mit "atoi" nicht direkt interpretiert werden !
uw_mask = atoi(temp) & 0xFFFF; // ! -> (1) Aufteilung in 2 "int"-Werte !
uw_mask = uw_mask << 16; // ! -> (2) anschliessend zusammensetzen !
tabget(temp, "UWTYP");
strerase(temp, 2, 4);
uw_mask = uw_mask | (atoi(temp) & 0xFFFF);
}
else // Normalfall: direkte Wandlung
uw_mask = atoi(temp);
tabget(text, "NAME"); // Zusatztabelle <Name>
set_trap_mask(0x0400); // Trap-Bit f<>r Tabellenzugriff setzen
tabset(text); // Tabelle bzgl. diskreter Werte oeffnen
if (get_error(10)) {
text1 = "Table not found";
strinsert(text1, text, 6);
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?0A?", text1, response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?0A?", text1, response,"_RESPONSE_200X", 0);
}
}
set_trap_mask(0); // Trap-Bit f<>r Tabellenzugriff ruecksetzen
uw_wert_mask = uw_wert_mask & uw_mask; // ! beide Masken unsigned int
itor(uw_wert_real, uw_wert_mask); // -> real (f<>r F_UWi_WERT) /*** ***/
tab_suche_unsigned("WERT", uw_wert_mask);
set_trap_mask(0x0400); // Trap-Bit f<>r Tabellenzugriff setzen
tabget(text, "UWTEXT"); // !!! >> "text1" wird noch gebraucht (F_UWn_WERT)
set_trap_mask(0); // Trap-Bit f<>r Tabellenzugriff ruecksetzen
if (get_error(10))
tabget(text, "TEXT"); // !!! >> "text1" wird noch gebraucht (F_UWn_WERT)
} // Ende 'else if (uw_typ & uw_typ_diskret)' !!! >> "text" wird noch gebraucht (F_UWn_TEXT)
// . . 3 Fall: UW vom Typ Hex . . . . . . . . . . . . . . . . . . . .
else if (uw_typ & uw_typ_hex) {
itoax(text, uw_wert); // !!! >> "text1" wird noch gebraucht (F_UWn_WERT)
strerase(text, 0, 10 - (2 * uw_laenge)) ; // Anzahl: 2 + (8 - (2 * uw_laenge))
}
// . . 4 Fall: UW vom Typ text . . . . . . . . . . . . . . . . . . .
else if (uw_typ & uw_typ_text) {
; // keine Ergebnisberechnung erforderlich
}
// . . 5 Fall: analoge UW . . . . . . . . . . . . . . . . . . . . . .
else if (uw_typ & uw_typ_analog) {
// ! nur bei long: d.h. nicht float / nicht double
if (!(uw_typ & uw_typ_float) && !(uw_typ & uw_typ_double))
itor(uw_wert_real, uw_wert); // <Bytes aus SG-Antwort> -> real
tabget(temp, "MUL"); // Multiplikator MUL
if (!strcmp(temp, "-") || !strcmp(temp, "--")) // bei "-" oder "--"
temp = "1"; // Default : 1
ator(uw_mul_real, temp); // -> real
tabget(temp, "DIV"); // Divisor DIV
if (!strcmp(temp, "-") || !strcmp(temp, "--")) // bei "-" oder "--"
temp = "1"; // Default : 1
ator(uw_div_real, temp); // -> real
ator(uw_add_real, "0.0"); // uw_add_real kurzfristig als (real) 0.0
if (realcomp(uw_div_real, "==", uw_add_real)) { // ! FEHLER (Division durch "0")
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?0A?", "DIVISION BY ZERO", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?0A?", "DIVISION BY ZERO", response,"_RESPONSE_200X", 0);
}
}
tabget(temp, "ADD"); // Offset ADD
if (!strcmp(temp, "-") || !strcmp(temp, "--")) // bei "-" oder "--"
temp = "0"; // Default : 0
ator(uw_add_real, temp); // -> real
realmul (uw_wert_real, uw_mul_real); // uw_wert_real = ( uw_wert_real * uw_mul_real
realdiv (uw_wert_real, uw_div_real); // / uw_div_real)
realadd (uw_wert_real, uw_add_real); // + uw_add_real;
} // Ende 'else if (uw_typ & uw_typ_analog'
// . . 6 Fall: Fehler, da nichts passt . . . . . . . . . . . . . . .
else {
temp = UmweltTexte;
if (!strcmp(temp, "FUmweltTexte")) {
new_set_of_results();
var_result_data("_RESPONSE_EXTENDED_DATA", response1);
return_with_message("?12?", "TYPE uw_typ NOT DEFINED (1)", response,"_RESPONSE_SNAPSHOT", 0);
}
else {
new_set_of_results();
var_result_data("_RESPONSE_2000", response1);
return_with_message("?12?", "TYPE uw_typ NOT DEFINED (1)", response,"_RESPONSE_200X", 0);
}
}
// . . Zuweisung Result "F_UWn_WERT" . . . . . . . . . . . . . . . . .
temp = text1;
strcat(temp, "_WERT");
/***
if ((uw_typ & uw_typ_diskret) || (uw_typ & uw_typ_hex)) // (string) bei diskreten UW (string) bei UW vom Typ "Hex"
var_result_string(temp, text); // !!! << text1 wieder frei
else // (real) bei sonstigen UW
var_result_real(temp, uw_wert_real);
***/
if (uw_typ & uw_typ_hex) // (string) bei UW vom Typ "Hex"
var_result_string(temp, text);
else if (uw_typ & uw_typ_text) { // (string) mit VS (Hr. Graf) abgestimmt !
dataclear(temp);
datacopy(temp, response, offset, uw_laenge);
if (uw_typ & uw_typ_low_high)
datarevers(temp);
hex2ascii(text, temp, 0, uw_laenge);
temp = text1;
strcat(temp, "_WERT");
var_result_string(temp, text);
}
else // (real) bei sonstigen UW
var_result_real(temp, uw_wert_real);
// . . Zuweisung Result "F_UWn_TEXT" . . . . . . . . . . . . . . . . . /*** ***/
temp = text1; // !!! << text1 wieder frei
strcat(temp, "_TEXT");
// Es wird zuerst die Standard-Tabelle durchsucht
tabset("DTCSnapshotIdentifier");
if (tab_suche_unsigned("UWNR", LIIdentifier) == 0)
tabset(UmweltTexte); // Wenn in der Standard-Tabelle der Eintrag nicht enthalten ist, dann wird auf die spezifische UW-Daten gegangen
tab_suche_unsigned("UWNR", LIIdentifier); // (wieder) in die richtige Zeile springen
tabget(text1, "UWTEXT");
if (uw_typ & uw_typ_diskret) {
strcat(text1, ": ");
strcat(text1, text);
}
var_result_string(temp, text1);
} // Ende 'if (uw_gueltig == 1) '
} while (uw_sub_index); // f<>r alle Sub-Identifier abarbeiten !
} // Ende else-Zweig von 'if (LIIdentifier == 0x1700 || LIIdentifier == 0x1701 || LIIdentifier == 0x1703)'
offset = offset + uw_laenge; // bei digitaler oder diskreter UW nicht grunds<64>tzlich weiterschalten !!!
// End of File
// end of : #include "UDS_FS_Snapshot.b2s"
#undef UmweltTexte
if (offset > daten_laenge) { // Der neue Offset ist l<>nger als die Datenl<6E>nge
uw_gueltig = 0; // ! keine Resultbildung mehr
new_set_of_results();
if (_RESPONSE_2000) _RESPONSE_2000 = response1;
return_with_message("?0A?", "TOO MUCH DATA IN RESPONSE-TELEGRAM", response,"_RESPONSE_200X", 0);
}
else
LICounterUW++;
pos_ende = offset;
laenge_snapshot -= (pos_ende - pos_start); // Ausgangsl<73>nge - L<>nge des Snapshots
}
if (F_UW_ANZ) // Anzahl der zusaetzlichen Umweltbedingungen ausgeben
F_UW_ANZ = LIAnzUW;
new_set_of_results(); // neuer Ergebnissatz ???
anzahl_snapshotRecord--;
}
// ---------------- JOB_STATUS, _RESPONSE* ---------------------------
if (_RESPONSE_2000)
_RESPONSE_2000 = response1;
if (_RESPONSE_200X)
_RESPONSE_200X = response;
if ((offset - (daten_laenge - laenge_ExtendedData)) == 0)
JOB_STATUS = "OKAY";
else
return_with_message("?12?", "INCORRECT NUMBER OF DATA IN RESPONSE-TELEGRAM", response,"_RESPONSE_200X", 0);
}
// End of File
// end of : #include "UDS_22_20_00_IS_LESEN_DETAIL.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_31_01_0F_06_IS_LOESCHEN.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VERAENDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : IS_LOESCHEN
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// Gueltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 22.03.2005 gh V0.001 Erstellung
// 28.07.2005 gh V0.002 Namens<6E>nderung dieser Datei
// 28.07.2005 gh V0.002 Entfernung defrslt
// 05.12.2005 gr V0.003 Anpassungen an send_and_receive_uds
// 01.02.2006 gr V0.004 Korrektur Auftragstelegramm
// *******************************************************************
// UDS_31_01_0F_06_IS_LOESCHEN.B2S @(#)@ V0.004 @(#)@
// *******************************************************************
job ( name : IS_LOESCHEN;
comment : Infospeicher loeschen;
comment : UDS : $31 RoutineControl;
comment : UDS : $01 startRoutine;
comment : UDS : $0F06 ClearSecondaryDTCMemory;
comment : Modus: Default;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x31, 0x01, 0x0F, 0x06};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_31_01_0F_06_IS_LOESCHEN.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_F1_8A_8B_HERSTELLINFO_LESEN.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : HERSTELLINFO_LESEN
// -------------------------------------------------------------------
// Globale Tabelle : JobResult, Lieferanten
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 12.12.2005 gr V0.001 Erstellung
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Job-Name)
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Tabellen-Name)
// 20.03.2007 gh V0.010 Service $F18A jetzt optional
// *******************************************************************
// UDS_22_F1_8A_8B_HERSTELLINFO_LESEN.B2S @(#)@ V0.010 @(#)@
// *******************************************************************
job ( name : HERSTELLINFO_LESEN;
comment : Lieferant und Herstelldatum lesen;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $F18A SystemSupplierIdentifier;
comment : UDS : $F18B ECUManufactoringData;
comment : Modus: Default;
result : ID_LIEF_NR;
type : long;
comment : Lieferantennummer;
comment : 0xFFFFFF, falls nicht vorhanden;
result : ID_LIEF_TEXT;
type : string;
comment : Text zu ID_LIEF_NR;
comment : table Lieferanten LIEF_TEXT;
comment : unbekannter Hersteller, falls nicht vorhanden;
result : ID_DATUM;
type : string;
comment : Herstelldatum (DD.MM.YY);
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
result : _REQUEST_2;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE_2;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x22, 0xF1, 0x8A};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
long LLData;
char temp[];
char temp2[];
// ---------------- Ueberpruefung ob Tabellen includiert sind --------
INCLUDE_UDS_Lieferanten_B2S_NOT_FOUND;
// -------------------------------------------------------------------
// Lieferant auslesen (optional)
if (ID_LIEF_NR || ID_LIEF_TEXT || _REQUEST || _RESPONSE) {
send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2);
if (response[0] == 0x62)
LLData = (response[3] << 16) + (response[4] << 8) + (response[5]);
else
LLData = 0xFFFFFF;
if (ID_LIEF_NR)
ID_LIEF_NR = LLData;
if (ID_LIEF_TEXT) {
tabset("Lieferanten");
tab_suche_unsigned("LIEF_NR", LLData);
tabget(temp, "LIEF_TEXT");
ID_LIEF_TEXT = temp;
}
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
}
// -------------------------------------------------------------------
// Herstelldatum auslesen (Pflicht)
if (ID_DATUM || _REQUEST_2 || _RESPONSE_2) {
if (ID_DATUM) {
dataclear(response);
dataclear(temp);
dataclear(temp2);
request = {0x22,0xF1,0x8B};
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
bcd2ascii(temp, response, 5, 1);
strcat(temp, ".");
bcd2ascii(temp2, response, 4, 1);
strcat(temp, temp2);
strcat(temp, ".");
bcd2ascii(temp2, response, 3, 1);
strcat(temp, temp2);
ID_DATUM = temp;
}
if (_REQUEST_2)
_REQUEST_2 = request;
if (_RESPONSE_2)
_RESPONSE_2 = response;
}
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_22_F1_8A_8B_HERSTELLINFO_LESEN.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_3E_DIAGNOSE_AUFRECHT.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : DIAGNOSE_AUFRECHT
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 16.12.2005 gr V0.001 Ersterstellung
// 02.02.2006 gr V0.002 STD_DIGI ersetzt UDS_TAB_DIGITAL_ARGUMENT
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Job-Name)
// *******************************************************************
// UDS_3E_DIAGNOSE_AUFRECHT.B2S @(#)@ V0.002 @(#)@
// *******************************************************************
job ( name : DIAGNOSE_AUFRECHT;
comment : Diagnosemode des SG aufrecht erhalten;
comment : UDS : $3E TesterPresent;
comment : UDS : $?0 suppressPosRspMsgIndication;
comment : Modus: Default;
argument : SG_ANTWORT;
type : string;
comment : "ja" -> SG soll antworten;
comment : "nein" -> SG soll nicht antworten;
comment : table DigitalArgument TEXT;
comment : Default: SG soll antworten;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x3E, 0xFF};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
int LIErgebnis;
// ---------------- Ueberpruefung ob Tabellen includiert sind --------
INCLUDE_STD_DIGI_B2S_NOT_FOUND;
// ---------------- Argumente des Jobs auswerten ---------------------
if (!check_digital_argument("SG_ANTWORT", 1, LIErgebnis, 1)) return;
if (LIErgebnis)
request[1] = 0x00;
else
request[1] = 0x80; // SG soll nicht antworten
// Bit7 suppressPosRspMsgIndicationBit -> 0x00 Antwort, 0x80 keine Antwort
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_3E_DIAGNOSE_AUFRECHT.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_10_DIAGNOSE_MODE.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : DIAGNOSE_MODE
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 18.11.2005 gr V0.001 Erstellung
// 02.02.2006 gr V0.002 STD_DIGI ersetzt UDS_TAB_DIGITAL_ARGUMENT
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Tabellen-Name)
// *******************************************************************
// UDS_10_DIAGNOSE_MODE.B2S @(#)@ V0.002 @(#)@
// *******************************************************************
job ( name : DIAGNOSE_MODE;
comment : SG in bestimmten Diagnosemode bringen;
comment : UDS : $10 StartDiagnosticSession;
comment : Modus: einstellbar mit diesem Job;
argument : MODE;
type : string;
comment : gewuenschter Diagnose-Modus;
comment : table DiagMode MODE MODE_TEXT;
comment : Defaultwert: DEFAULT (DefaultMode);
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{ // defaultSession
unsigned char request[] = {0x10, 0x01};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
unsigned char temp[];
unsigned char arg[];
// ---------------- Ueberpruefung ob Tabellen includiert sind --------
INCLUDE_UDS_TAB_DiagMode_B2S_NOT_FOUND;
// ---------------- Argumente des Jobs auswerten ---------------------
if (exist(MODE))
{
tabset("DiagMode");
arg = MODE;
if (tabseek("MODE", arg))
{
tabget(temp, "NR");
request[1] = atoi(temp);
}
else
{
JOB_STATUS = "ERROR_MODE";
return;
}
}
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_10_DIAGNOSE_MODE.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_11_04_SLEEP_MODE.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : SLEEP_MODE
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 16.12.2005 gr V0.001 Erstellung
// *******************************************************************
// UDS_11_04_SLEEP_MODE.B2S @(#)@ V0.001 @(#)@
// *******************************************************************
job ( name : SLEEP_MODE;
comment : SG in Sleep-Mode versetzen;
comment : UDS : $11 ECUReset;
comment : UDS : $04 EnableRapidPowerShutDown;
comment : Modus: Default;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x11, 0x04};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_11_04_SLEEP_MODE.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_31_01_0F_0C_ENERGIESPARMODE.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : ENERGIESPARMODE
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 05.12.2005 gr V0.001 Erstellung
// 20.12.2005 gr V0.002 Zusammenfassung der Argumente
// 01.02.2006 gr V0.003 Interne Variable fuer Argument hinzu
// *******************************************************************
// UDS_31_01_0F_0C_ENERGIESPARMODE.B2S @(#)@ V0.003 @(#)@
// *******************************************************************
job ( name : ENERGIESPARMODE;
comment : Einstellen des Energiesparmodes;
comment : UDS : $31 RoutineControlRequestServiceID;
comment : UDS : $01 startRoutine;
comment : UDS : $0F0C DataIdentifier ControlEnergySavingMode;
comment : UDS : $?? Mode;
comment : Modus : Default;
argument : MODE;
type : int;
comment : 0x00: Normalmode;
comment : 0x01: Fertigungsmode;
comment : 0x02: Transportmode;
comment : 0x03: Flashmode;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x31, 0x01, 0x0F, 0x0C, 0xFF};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
int arg;
// ---------------- Argumente des Jobs auswerten ---------------------
arg = MODE;
if ((exist(MODE)) && (arg < 4))
request[4] = arg;
else
{
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_31_01_0F_0C_ENERGIESPARMODE.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_10_0A_STATUS_ENERGIESPARMODE.b2s"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : STATUS_ENERGIESPARMODE
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 12.12.2005 gr V0.001 Ersterstellung
// 04.04.2006 rd V0.002 Rechtschreibfehler behoben
// *******************************************************************
// UDS_22_10_0A_STATUS_ENERGIESPARMODE.B2S @(#)@ V0.002 @(#)@
// *******************************************************************
job ( name : STATUS_ENERGIESPARMODE;
comment : Energy-Saving-Mode auslesen;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $100A DataIdentifier EnergySavingMode;
comment : Modus: Default;
result : STAT_ENERGIESPARMODE_WERT;
type : int;
comment : Ausgabe des Energiesparmodes;
comment : 0: Kein Energiesparmode gesetzt;
comment : 1: Produktionsmode gesetzt;
comment : 2: Transportmode gesetzt;
comment : 3: Flashmode gesetzt;
comment : -1: Mode ungueltig;
result : STAT_ENERGIESPARMODE_TEXT;
type : string;
comment : Text zu STAT_ENERGIESPARMODE_WERT;
result : STAT_PRODUKTIONSMODE_EIN;
type : int;
comment : 0: Produktionsmode nicht aktiv;
comment : 1: Produktionsmode aktiv;
result : STAT_TRANSPORTMODE_EIN;
type : int;
comment : 0: Transportmode nicht aktiv;
comment : 1: Transportmode aktiv;
result : STAT_FLASHMODE_EIN;
type : int;
comment : 0: Flashmode nicht aktiv;
comment : 1: Flashmode aktiv;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x22, 0x10, 0x0A};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (response[3] == 0x00)
{
if(STAT_PRODUKTIONSMODE_EIN)
STAT_PRODUKTIONSMODE_EIN = 0;
if(STAT_TRANSPORTMODE_EIN)
STAT_TRANSPORTMODE_EIN = 0;
if(STAT_FLASHMODE_EIN)
STAT_FLASHMODE_EIN = 0;
if (STAT_ENERGIESPARMODE_WERT)
STAT_ENERGIESPARMODE_WERT = 0;
if (STAT_ENERGIESPARMODE_TEXT)
STAT_ENERGIESPARMODE_TEXT = "Energiesparmode nicht aktiv";
}
else if (response[3] == 0x01)
{
if(STAT_PRODUKTIONSMODE_EIN)
STAT_PRODUKTIONSMODE_EIN = 1;
if(STAT_TRANSPORTMODE_EIN)
STAT_TRANSPORTMODE_EIN = 0;
if(STAT_FLASHMODE_EIN)
STAT_FLASHMODE_EIN = 0;
if (STAT_ENERGIESPARMODE_WERT)
STAT_ENERGIESPARMODE_WERT = 1;
if (STAT_ENERGIESPARMODE_TEXT)
STAT_ENERGIESPARMODE_TEXT = "Produktionsmode";
}
else if (response[3] == 0x02)
{
if(STAT_PRODUKTIONSMODE_EIN)
STAT_PRODUKTIONSMODE_EIN = 0;
if(STAT_TRANSPORTMODE_EIN)
STAT_TRANSPORTMODE_EIN = 1;
if(STAT_FLASHMODE_EIN)
STAT_FLASHMODE_EIN = 0;
if (STAT_ENERGIESPARMODE_WERT)
STAT_ENERGIESPARMODE_WERT = 2;
if (STAT_ENERGIESPARMODE_TEXT)
STAT_ENERGIESPARMODE_TEXT = "Transportmode";
}
else if (response[3] == 0x03)
{
if(STAT_PRODUKTIONSMODE_EIN)
STAT_PRODUKTIONSMODE_EIN = 0;
if(STAT_TRANSPORTMODE_EIN)
STAT_TRANSPORTMODE_EIN = 0;
if(STAT_FLASHMODE_EIN)
STAT_FLASHMODE_EIN = 1;
if (STAT_ENERGIESPARMODE_WERT)
STAT_ENERGIESPARMODE_WERT = 3;
if (STAT_ENERGIESPARMODE_TEXT)
STAT_ENERGIESPARMODE_TEXT = "Flashmode";
}
else
{
if(STAT_PRODUKTIONSMODE_EIN)
STAT_PRODUKTIONSMODE_EIN = 0;
if(STAT_TRANSPORTMODE_EIN)
STAT_TRANSPORTMODE_EIN = 0;
if(STAT_FLASHMODE_EIN)
STAT_FLASHMODE_EIN = 0;
if (STAT_ENERGIESPARMODE_WERT)
STAT_ENERGIESPARMODE_WERT = -1;
if (STAT_ENERGIESPARMODE_TEXT)
STAT_ENERGIESPARMODE_TEXT = "Mode ung<6E>ltig";
}
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_22_10_0A_STATUS_ENERGIESPARMODE.b2s"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_16_00_SENSOREN_ANZAHL_LESEN.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : SENSOREN_ANZAHL_LESEN
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 12.12.2005 gr V0.001 Ersterstellung auf Basis STD22160
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Job-Name)
// *******************************************************************
// UDS_22_16_00_SENSOREN_ANZAHL_LESEN.B2S @(#)@ V0.002 @(#)@
// *******************************************************************
job ( name : SENSOREN_ANZAHL_LESEN;
comment : Anzahl der intelligenten Subbussensoren lesen;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $1600 Identifier NumberofSubbusMembers;
comment : Modus: Default;
result : SENSOR_ANZAHL;
type : long;
comment : Anzahl der intelligenten Subbussensoren;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x22, 0x16, 0x00};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (SENSOR_ANZAHL)
SENSOR_ANZAHL = response[3];
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_22_16_00_SENSOREN_ANZAHL_LESEN.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_16_XX_SENSOREN_IDENT_LESEN.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : SENSOREN_IDENT_LESEN
// -------------------------------------------------------------------
//
// Globale Tabellen : JobResult,VerbauortTabelle,PartNrTabelle
//
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 12.12.2005 gr V0.001 Ersterstellung auf Basis STD2216X
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Job-Name)
// 23.10.2006 rd V0.003 Verbauort mit SG-Adresse verkn<6B>pft
// 04.02.2007 gr V0.004 Auswertung optionaler LIN-Daten hinzu
// 03.07.2007 gh V0.005 neues Result "SENSOR_VERBAUORT_NR", Anforderer: Robert Lorenz, TI-431
// 21.02.2008 gr V0.006 Argument um VERBAUORT erweitert, damit Auswahl eines bestimmten Sensors m<>glich
// 21.02.2008 gr V0.006 Bei *W_RELEASE umgestellt von BCD-Dekodierung auf HEX-Anzeige (nach R<>cksprache mit Hrn. Thierauf)
// *******************************************************************
// UDS_22_16_XX_SENSOREN_IDENT_LESEN.B2S @(#)@ V0.006 @(#)@
// *******************************************************************
job ( name : SENSOREN_IDENT_LESEN;
comment : Identifikation der intelligenten Subbussensoren lesen;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $1600 Identifier NumberofSubbusMembers;
comment : UDS : $16xx SubbusMemberSerialNumber;
comment : Modus: Default;
argument : SENSOR_NR;
type : long;
comment : optionales Argument;
comment : gewuenschter Sensor xx (0x01 - 0xFF);
comment : oder VERBAUORT eines bestimmten Sensors (table VerbauortTabelle ORT);
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : SENSOR_VERBAUORT;
type : string;
comment : Verbauort des Sensors;
comment : table VerbauortTabelle ORTTEXT;
result : SENSOR_VERBAUORT_NR;
type : long;
comment : Verbauort-Nummer des Sensors;
result : SENSOR_BMW_NR;
type : string;
comment : BMW-Teilenummer des Sensors;
result : SENSOR_PART_NR;
type : string;
comment : Teilenummer des Sensors;
comment : optional wenn SENSOR_BMW_NR gueltig;
comment : wenn Teilenummer vom Sensor nicht verfuegbar dann '--';
result : SENSOR_LIN_2_0_FORMAT;
type : int;
comment : 1: Die optionalen Daten des Sensors (Hersteller, Seriennummer, ...) werden in LIN_2_Format geliefert;
comment : 0: Optionale Daten nicht im LIN_2_Format (nur Defaultwerte werden ausgegeben);
result : SENSOR_HERSTELLER_NR;
type : long;
comment : Lieferantennummer des Herstellers;
comment : wenn Hersteller-Nummer nicht verfuegbar, dann 0;
result : SENSOR_HERSTELLER_TEXT;
type : string;
comment : Textausgabe Lieferant;
comment : wenn Softwarestand nicht verfuegbar, dann 'Information nicht verfuegbar';
result : SENSOR_FUNKTIONS_NR;
type : long;
comment : Funktionsnummer des Sensors;
comment : wenn Funktions-Nummer nicht verfuegbar, dann 0;
result : SENSOR_VARIANTEN_NR;
type : long;
comment : Variantennummer des Sensors;
comment : wenn Varianten-Nummer nicht verfuegbar, dann 0;
result : SENSOR_PROD_DATUM;
type : string;
comment : Produnktionsdatum (DD.MM.YY) des Sensors;
comment : wenn Produktions-Datum nicht verfuegbar, dann '--';
result : SENSOR_SERIEN_NR;
type : string;
comment : Seriennummer des Sensors;
comment : wenn Serien-Nummer nicht verfuegbar, dann '--';
result : SENSOR_SW_RELEASE_NR;
type : string;
comment : Softwarestand des Sensors;
comment : wenn Softwarestand nicht verfuegbar, dann '--';
result : SENSOR_HW_RELEASE_NR;
type : string;
comment : Hardwarestand des Sensors;
comment : wenn Softwarestand nicht verfuegbar, dann '--';
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
result : _REQUEST_2;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE_2;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x22, 0x16, 0x00};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
//unsigned char buffer[];
unsigned char buffer2[];
unsigned char temp[];
unsigned char temp2[];
int retval;
long sensor_nr = 0;
long LLSensorVerbauort = 0;
unsigned int k;
unsigned int anzahl;
unsigned int LIData = 0;
unsigned int LBFound = 0;
// ---------------- Ueberpruefung ob Tabellen includiert sind --------
INCLUDE_STD_ISEN_B2S_NOT_FOUND;
INCLUDE_UDS_LieferantenLIN_B2S_NOT_FOUND; // Tabelle f<>r LIN-Teilnehmer
// ---------------- Argumente des Jobs auswerten ---------------------
if (exist(SENSOR_NR))
{
// Zuerst die Abfrage, ob es sich um einen Sensor aus der Tabelle 'VerbauOrtTabelle' handelt
LLSensorVerbauort = SENSOR_NR;
tabset("VerbauortTabelle");
if ((tab_suche_unsigned("ORT", LLSensorVerbauort)) == TRUE) // Es handelt sich bei dem Argument um einen Verbauort
{
}
else // Es handelt sich um eine Sensor-Nummer
{
LLSensorVerbauort = 0xFFFFFFFF;
sensor_nr = SENSOR_NR;
if (sensor_nr < 1 || sensor_nr > 255)
{
JOB_STATUS = "ERROR_ARGUMENT";
return;
}
}
}
else
{
LBFound = 1;
LLSensorVerbauort = 0xFFFFFFFF;
}
// ---------------- Anzahl ermitteln ---------------------------------
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (response[3] == 0)
{
JOB_STATUS = "OKAY";
return;
}
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
// ---------------- Seriennummern lesen ------------------------------
// ---------------- Kommunikation ------------------------------------
if (sensor_nr == 0)
{
k = 1;
anzahl = response[3];
}
else
{
anzahl = sensor_nr;
k = sensor_nr;
}
while (k <= anzahl)
{
request = {0x22,0x16,0x00};
request[2] = k;
retval = send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2);
// ---------------- Interpretation -----------------------------------
if (retval == 1)
{
tabset("VerbauortTabelle");
if (!tab_suche_unsigned("ORT", (SA_response<<16) + (response[3]<<8) + response[4]))
tab_suche_unsigned("ORT", (response[3]<<8) + response[4]);
tabget(buffer2, "ORTTEXT");
tabget(temp,"LIN_2_FORMAT");
// Keine bestimmte Sensor-Abfrage oder bestimmte Sensor-Abfrage und Sensor gefunden
if ((LLSensorVerbauort == 0xFFFFFFFF) || ((LLSensorVerbauort != 0xFFFFFFFF) &&(((response[3] << 8) + response[4]) == LLSensorVerbauort)))
{
if (SENSOR_VERBAUORT)
SENSOR_VERBAUORT = buffer2;
if (SENSOR_VERBAUORT_NR)
SENSOR_VERBAUORT_NR = (response[3] << 8) + response[4];
// Abfrage ob Daten im LIN 2.0 Format oder nicht
if (strcmp(temp,"1") == 0) // Sensor liefert die Daten nach 2.0-Standard
{
// Sollten zuwenig Daten kommen, dann wird abgebrochen
if (datalen(response) < 27)
return_with_message("?12?", "INCORRECT NUMBER OF DATA IN RESPONSE-TELEGRAM", response,buffer2, 1);
if (SENSOR_LIN_2_0_FORMAT)
SENSOR_LIN_2_0_FORMAT = 1;
if (SENSOR_BMW_NR)
{ // Offen ist noch, was mit dem ersten Byte passieren soll,
// da vom LIN an sich nur 5 Byte kommen und das 6. Byte vom Master bef<65>llt wird
// Die Frage ist nur, wie? Kl<4B>rung AK Diagnose
hex2ascii(temp,response,5,6);
if (strcmp(temp,"FFFFFFFFFFFF") == 0)
{
if (datalen(response) > 11)
{
hex2ascii(temp,response,11,datalen(response)-11);
tabset("PartNrTabelle");
tabseek("PART_NR", temp);
tabget(buffer2, "BMW_NR");
}
else
{
buffer2 = "--";
}
SENSOR_BMW_NR = buffer2;
}
else
{
dataclear(temp);
datacopy(temp,response, 5, 6);
BRstandard(buffer2,temp);
}
SENSOR_BMW_NR = buffer2;
}
if (SENSOR_HERSTELLER_NR)
{ // 2 Byte Herstellernummer
SENSOR_HERSTELLER_NR = (response[11] << 8) + response[12];
}
if (SENSOR_HERSTELLER_TEXT)
{ // Text kommt aus Tabelle die aus Informationen von der LIN-Homepage erstellt wurden
dataclear(temp);
LIData = (response[11] << 8) + response[12];
tabset("LieferantenLIN");
tab_suche_unsigned("LIEF_NR", LIData);
tabget(temp, "LIEF_TEXT");
SENSOR_HERSTELLER_TEXT = temp;
}
if (SENSOR_FUNKTIONS_NR)
{ // Funktionsnummer des Sensors (wird bei Kommunikation Master / Slave ben<65>tigt)
SENSOR_FUNKTIONS_NR = (response[13] << 8) + response[14];
}
if (SENSOR_VARIANTEN_NR)
{ // Variantennummer (wird ebenfalls bei der Kommunikation gebraucht)
SENSOR_VARIANTEN_NR = response[15];
}
if (SENSOR_PROD_DATUM)
{ // Das Produktionsdatum wird in 3 Byte geliefert
// Reihenfolge im Telegramm YY.MM.DD
dataclear(temp);
dataclear(temp2);
bcd2ascii(temp, response, 18, 1); // Tag
strcat(temp, ".");
bcd2ascii(temp2, response, 17, 1); //Monat
strcat(temp, temp2);
strcat(temp, ".");
bcd2ascii(temp2, response, 16, 1); //Jahr
strcat(temp, temp2);
SENSOR_PROD_DATUM = temp;
}
if (SENSOR_SERIEN_NR)
{ // Seriennummer muss laut Hr. Thierauf (LIN-Spezialist) nicht konvertiert werden
dataclear(temp);
hex2ascii(temp,response,19,4);
SENSOR_SERIEN_NR = temp;
}
if (SENSOR_SW_RELEASE_NR)
{ // 1. Byte: Hauptversionsnummer
// 2. Byte: Nebenversionsnummer
dataclear(temp);
dataclear(temp2);
hex2ascii(temp, response, 23, 1); // Hauptversionsnummer
strcat(temp, ".");
hex2ascii(temp2, response, 24, 1); //Nebenversionsnummer
strcat(temp, temp2);
SENSOR_SW_RELEASE_NR = temp;
}
if (SENSOR_HW_RELEASE_NR)
{ // 1. Byte: Hauptversionsnummer
// 2. Byte: Nebenversionsnummer
dataclear(temp);
dataclear(temp2);
hex2ascii(temp, response, 25, 1); // Hauptversionsnummer
strcat(temp, ".");
hex2ascii(temp2, response, 26, 1); //Nebenversionsnummer
strcat(temp, temp2);
SENSOR_HW_RELEASE_NR = temp;
}
}
else
{
if (SENSOR_BMW_NR)
{
hex2ascii(temp,response,5,6);
if (strcmp(temp,"FFFFFFFFFFFF") == 0)
{
if (datalen(response) > 11)
{
hex2ascii(temp,response,11,datalen(response)-11);
tabset("PartNrTabelle");
tabseek("PART_NR", temp);
tabget(buffer2, "BMW_NR");
}
else
{
buffer2 = "--";
}
SENSOR_BMW_NR = buffer2;
}
else
{
dataclear(temp);
datacopy(temp,response, 5, 6);
BRstandard(buffer2,temp);
}
SENSOR_BMW_NR = buffer2;
}
// Sofern keine BMW-Teilenummer vorhanden ist
if (SENSOR_PART_NR)
{
if (datalen(response) > 11)
{
hex2ascii(buffer2,response,11,datalen(response)-11);
SENSOR_PART_NR = buffer2;
}
else
{
SENSOR_PART_NR = "--";
}
}
// Informationen aus LIN 2.0- Format sind nicht verfuegbar
if (SENSOR_LIN_2_0_FORMAT)
SENSOR_LIN_2_0_FORMAT = 0;
if (SENSOR_HERSTELLER_NR)
SENSOR_HERSTELLER_NR = 0;
if (SENSOR_HERSTELLER_TEXT)
SENSOR_HERSTELLER_TEXT = "--";
if (SENSOR_FUNKTIONS_NR)
SENSOR_FUNKTIONS_NR = 0;
if (SENSOR_VARIANTEN_NR)
SENSOR_VARIANTEN_NR = 0;
if (SENSOR_PROD_DATUM)
SENSOR_PROD_DATUM = "--";
if (SENSOR_SERIEN_NR)
SENSOR_SERIEN_NR = "--";
if (SENSOR_SW_RELEASE_NR)
SENSOR_SW_RELEASE_NR = "--";
if (SENSOR_HW_RELEASE_NR)
SENSOR_HW_RELEASE_NR = "--";
} // Ende ELSE-Zweig if (strcmp(temp,"1") == 0)
if (_REQUEST_2)
_REQUEST_2 = request;
if (_RESPONSE_2)
_RESPONSE_2 = response;
JOB_STATUS = "OKAY";
}
}
if (sensor_nr != 0) return;
new_set_of_results();
if ((LLSensorVerbauort != 0xFFFFFFFF) &&(((response[3] << 8) + response[4]) == LLSensorVerbauort))
{
LBFound = 1;
k = anzahl;
}
k++;
} // while (k <= anzahl)
if (LBFound == 0)
JOB_STATUS = "SENSOR_NOT_ASSEMBLED_OR_WRONG_ARGUMENT";
else
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_22_16_XX_SENSOREN_IDENT_LESEN.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_11_STEUERGERAETE_RESET.B2S"
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : STEUERGERAETE_RESET
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8
// SAP 10000786
// -------------------------------------------------------------------
// History:
// 05.12.2005 gr V0.001 Erstellung
// 02.02.2006 gh V0.002 Include-Name ge<67>ndert (wie Job-Name)
// *******************************************************************
// UDS_11_STEUERGERAETE_RESET.B2S @(#)@ V0.002 @(#)@
// *******************************************************************
job ( name : STEUERGERAETE_RESET;
comment : Harter Reset des Steuergeraets;
comment : UDS : $11 EcuReset;
comment : UDS : $01 HardReset;
comment : Modus: Default;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x11, 0x01};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_11_STEUERGERAETE_RESET.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_JOBS_ROE.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VERAENDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Verantwortung : BMW AG, Tobias Kraeker, EI-71
// -------------------------------------------------------------------
// optinale Standardjobs Unified Diagnostic Services (UDS) nach ISO 14229
// (Response on event)
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnosemaster
// -------------------------------------------------------------------
// History:
// 04.12.2006 an V0.001 Erstellung (Patrick Hess, TI-430)
// *******************************************************************
// UDS_JOBS_ROE.B2S @(#)@ V0.001@(#)@
// *******************************************************************
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_86_00_02_STEUERN_ROE_STOP.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VERAENDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : STEUERN_ROE_STOP
// -------------------------------------------------------------------
// Verantwortung : BMW AG, Tobias Kraeker, EI-71
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnosemaster
// -------------------------------------------------------------------
// History:
// 30.11.2006 an V0.001 Erstellung (Tobias Kraeker, EI-71, Albrecht Neff, EI-71)
// *******************************************************************
// UDS_86_00_02_STEUERN_ROE_STOP.B2S @(#)@ V0.001@(#)@
// *******************************************************************
job ( name : STEUERN_ROE_STOP;
comment : Temporaeres Deaktivieren der;
comment : aktiven Fehlermeldung;
comment : UDS : $86 ResponseOnEvent;
comment : $00 Stop;
comment : $02 (EventWindowTime);
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// Variablen fuer Kommunikation
unsigned char request[] = {0x86,0x00,0x02};
unsigned char expectedResponse[] = {0xC6,0x00,0x00,0x02};
unsigned char response[];
unsigned char SA_response;
unsigned char TA_response;
//KONSTANTEN
unsigned char EXPECTED_RESPONSE_LENGTH = 4;
// ---------------- Argumente des Jobs auswerten ---------------------
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
if(datalen(response) != EXPECTED_RESPONSE_LENGTH)
{
JOB_STATUS = "ERROR_ECU_INCORRECT_LEN";
return;
}
else if(datacmp(expectedResponse,response)!=0)
{
JOB_STATUS = "ERROR_INTERPRETATION";
return;
}
else
{
JOB_STATUS = "OKAY";
}
}
// end of : #include "UDS_86_00_02_STEUERN_ROE_STOP.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_86_04_STATUS_ROE_REPORT.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VERAENDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : STATUS_ROE_REPORT
// -------------------------------------------------------------------
// Verantwortung : BMW AG, Tobias Kraeker, EI-32
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnosemaster
// -------------------------------------------------------------------
// History:
// 30.11.2006 an V0.001 Erstellung (Tobias Kraeker, EI-71, Albrecht Neff, EI-71)
// 28.11.2011 MiH V0.002 Michael Holzner, RUETZ TECHNOLOGIES GmbH f<>r BMW EI-32
// - Update RoE-Status, Toleranz f<>r Response ohne StoreEvent-Flag gesetzt
// - 35up kompatibilit<69>t: falls 86 04 zu INCORRECT_LENGTH f<>hrt, wird 86 04 02
// ausgef<65>hrt, wie ab DM LH V11 gefordert (UDS-konform)
// - Robustheitsmassnahmen
// *******************************************************************
// UDS_86_04_STATUS_ROE_REPORT.B2S @(#)@ V0.002@(#)@
// *******************************************************************
job ( name : STATUS_ROE_REPORT;
comment : Abfrage Status der Aktivierung der aktiven Fehlermeldung;
comment : UDS: $86 ResponseOnEvent;
comment : $04 report activated events;
comment : [$02 eventWindowTime - infinite (nur 35up)];
result : STAT_ROE_AKTIV;
type : char;
comment : 0x00 = Aktive Fehlermeldung deaktiviert;
comment : 0x01 = Aktive Fehlermeldung aktiviert;
comment : 0xFF = Status der aktiven Fehlermeldung nicht feststellbar;
result : STAT_ROE_AKTIV_TEXT;
type : string;
comment : Interpretation von STAT_ROE_AKTIV;
comment : table UDS_TAB_ROE_AKTIV TEXT;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
// result : STATE_35UP;
// type : string;
// comment : NO, falls SG nach LH DM V9 (LG,LK,LU,LI) - antwortet korrekt auf 86 04;
// comment : 35UP, falls SG nach LH DM >V11 (35UP) - antwortet korrekt auf 86 04 02;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// Variablen fuer Kommunikation
unsigned char request[] = {0x86,0x04};
unsigned char request35up[] = {0x86,0x04,0x02};
// unsigned char expectedResponseActivated[] = {0xC6,0x04,0x01,0x43,0x02,0x17,0x04,0x22,0x17,0x04};
// unsigned char expectedResponseActivatedTemp[] = {0xC6,0x04,0x01,0x03,0x02,0x17,0x04,0x22,0x17,0x04};
unsigned char expectedResponseDeactivated[] = {0xC6,0x04,0x00};
unsigned char response[];
unsigned char interpretation[];
unsigned char SA_response;
unsigned char TA_response;
unsigned char index;
unsigned char TryRequest860402;
//KONSTANTEN
unsigned char EXPECTED_RESPONSE_LENGTH_ACTIVATED = 10;
unsigned char EXPECTED_RESPONSE_LENGTH_DEACTIVATED = 3;
// ---------------- Argumente des Jobs auswerten ---------------------
// ---------------- Kommunikation ------------------------------------
TryRequest860402 = 0;
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2))
{ // also NOK..
if ((0x7F == response[0]) &&
(0x86 == response[1]) &&
(0x13 == response[2])) // 7F 86 13 INVALID LENGTH
{
request = request35up;
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
TryRequest860402 = 1;
}
else
return;
}
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
if((datalen(response) == EXPECTED_RESPONSE_LENGTH_ACTIVATED) &&
// ((datacmp(expectedResponseActivated,response)==0) ||
// (datacmp(expectedResponseActivatedTemp,response)==0)) ) // <20>nderung 28.11.2011 MiH
(0xC6 == response[0]) &&
(0x04 == response[1]) &&
(0x01 == response[2]) &&
((!TryRequest860402 && (0x03==response[3])) || (0x43 == response[3])) &&
(0x02 == response[4]))
{
if(STAT_ROE_AKTIV)
STAT_ROE_AKTIV = 1;
// if (STATE_35UP)
// {
// if (0 == TryRequest860402)
// STATE_35UP = "NO";
// else
// STATE_35UP = "35UP";
// }
if(STAT_ROE_AKTIV_TEXT)
{
tabset("UDS_TAB_ROE_AKTIV");
index = 1;
tab_suche_unsigned("NR",index);
tabget(interpretation,"TEXT");
STAT_ROE_AKTIV_TEXT = interpretation;
}
JOB_STATUS = "OKAY";
return;
}
else if((datalen(response) == EXPECTED_RESPONSE_LENGTH_DEACTIVATED) &&
(datacmp(expectedResponseDeactivated,response)==0))
{
if(STAT_ROE_AKTIV)
STAT_ROE_AKTIV = 0;
// if (STATE_35UP)
// {
// if (0 == TryRequest860402)
// STATE_35UP = "NO";
// else
// STATE_35UP = "35UP";
// }
if(STAT_ROE_AKTIV_TEXT)
{
tabset("UDS_TAB_ROE_AKTIV");
index = 0;
tab_suche_unsigned("NR",index);
tabget(interpretation,"TEXT");
STAT_ROE_AKTIV_TEXT = interpretation;
}
JOB_STATUS = "OKAY";
return;
}
else
{
if(STAT_ROE_AKTIV)
STAT_ROE_AKTIV = 0xFF;
if(STAT_ROE_AKTIV_TEXT)
{
tabset("UDS_TAB_ROE_AKTIV");
index = 0xFF;
tab_suche_unsigned("NR",index);
tabget(interpretation,"TEXT");
STAT_ROE_AKTIV_TEXT = interpretation;
}
JOB_STATUS = "OKAY";
return;
}
JOB_STATUS = "ERROR_INTERPRETATION";
return;
}
// end of : #include "UDS_86_04_STATUS_ROE_REPORT.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_86_05_02_STEUERN_ROE_START.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VERAENDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : STEUERN_ROE_START
// -------------------------------------------------------------------
// Verantwortung : BMW AG, Tobias Kraeker, EI-71
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnosemaster
// -------------------------------------------------------------------
// History:
// 30.11.2006 an V0.001 Erstellung (Tobias Kraeker, EI-71, Albrecht Neff, EI-71)
// *******************************************************************
// UDS_86_05_02_STEUERN_ROE_START.B2S @(#)@ V0.001@(#)@
// *******************************************************************
job ( name : STEUERN_ROE_START;
comment : Temporaeres Aktivieren;
comment : der aktiven Fehlermeldung;
comment : UDS : $86 ResponseOnEvent;
comment : $05 Start;
comment : $02 (EventWindowTime);
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// Variablen fuer Kommunikation
unsigned char request[] = {0x86,0x05,0x02};
unsigned char expectedResponse[] = {0xC6,0x05,0x00,0x02};
unsigned char response[];
unsigned char SA_response;
unsigned char TA_response;
//KONSTANTEN
unsigned char EXPECTED_RESPONSE_LENGTH = 4;
// ---------------- Argumente des Jobs auswerten ---------------------
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
if(datalen(response) != EXPECTED_RESPONSE_LENGTH)
{
JOB_STATUS = "ERROR_ECU_INCORRECT_LEN";
return;
}
else if(datacmp(expectedResponse,response)!=0)
{
JOB_STATUS = "ERROR_INTERPRETATION";
return;
}
else
{
JOB_STATUS = "OKAY";
}
}
// end of : #include "UDS_86_05_02_STEUERN_ROE_START.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_86_40_02_STEUERN_ROE_PERSISTENT_STOP.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VERAENDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : STEUERN_ROE_PERSISTENT_STOP
// -------------------------------------------------------------------
// Verantwortung : BMW AG, Tobias Kraeker, EI-71
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnosemaster
// -------------------------------------------------------------------
// History:
// 30.11.2006 an V0.001 Erstellung (Tobias Kraeker, EI-71, Albrecht Neff, EI-71)
// *******************************************************************
// UDS_86_40_02_STEUERN_ROE_PERSISTENT_STOP.B2S @(#)@ V0.001@(#)@
// *******************************************************************
job ( name : STEUERN_ROE_PERSISTENT_STOP;
comment : Persistentes Deaktivieren;
comment : der aktiven Fehlermeldung;
comment : an den Diagnosemaster ueber TAS;
comment : UDS : $86 ResponseOnEvent;
comment : $40 Stop persistent;
comment : $02 (EventWindowTime);
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// Variablen fuer Kommunikation
unsigned char TAS_address = 0xF0;
unsigned char request_to_TAS[] = {0x31,0x01,0x0f,0x0b,0xFF,0x00,0x03,0x86,0x40,0x02};
unsigned char expectedResponse[] = {0x71,0x01,0x0f,0x0b,0xFF,0x00,0x04,0xC6,0x40,0x00,0x02};
unsigned char response[];
unsigned char SA_response;
unsigned char TA_response;
unsigned char jobResultNegativeResponse[];
unsigned char index;
//KONSTANTEN
unsigned char EXPECTED_RESPONSE_LENGTH = 11;
unsigned char NEGATIVE_RESPONSE_LENGTH = 10;
request_to_TAS[4] = TA;
expectedResponse[4] = TA;
// ---------------- Argumente des Jobs auswerten ---------------------
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TAS_address, TA_TYPE_PHYSICAL, request_to_TAS, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request_to_TAS;
if (_RESPONSE)
_RESPONSE = response;
if(datalen(response) == NEGATIVE_RESPONSE_LENGTH)
{
if((response[7] = 0x7f) && (response[8] = 0x86))
{
tabset("JobResult");
index = response[9];
tab_suche_unsigned("SB",index);
tabget(jobResultNegativeResponse,"STATUS_TEXT");
JOB_STATUS = jobResultNegativeResponse;
return;
}
}
if(datalen(response) != EXPECTED_RESPONSE_LENGTH)
{
JOB_STATUS = "ERROR_ECU_INCORRECT_LEN";
return;
}
else if(datacmp(expectedResponse,response)!=0)
{
JOB_STATUS = "ERROR_INTERPRETATION";
return;
}
else
{
JOB_STATUS = "OKAY";
}
}
// end of : #include "UDS_86_40_02_STEUERN_ROE_PERSISTENT_STOP.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_86_45_02_STEUERN_ROE_PERSISTENT_START.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VERAENDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : STEUERN_ROE_PERSISTENT_START
// -------------------------------------------------------------------
// Verantwortung : BMW AG, Tobias Kraeker, EI-71
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnosemaster
// -------------------------------------------------------------------
// History:
// 30.11.2006 an V0.001 Erstellung (Tobias Kraeker, EI-71, Albrecht Neff, EI-71)
// *******************************************************************
// UDS_86_45_02_STEUERN_ROE_PERSISTENT_START.B2S @(#)@ V0.001@(#)@
// *******************************************************************
job ( name : STEUERN_ROE_PERSISTENT_START;
comment : Persistentes Aktivieren;
comment : der aktiven Fehlermeldung;
comment : an den Diagnosemaster ueber TAS;
comment : UDS : $86 ResponseOnEvent;
comment : $45 Start persistent;
comment : $02 (EventWindowTime);
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// Variablen fuer Kommunikation
unsigned char TAS_address = 0xF0;
unsigned char request_to_TAS[] = {0x31,0x01,0x0f,0x0b,0xFF,0x00,0x03,0x86,0x45,0x02};
unsigned char expectedResponse[] = {0x71,0x01,0x0f,0x0b,0xFF,0x00,0x04,0xC6,0x45,0x00,0x02};
unsigned char response[];
unsigned char SA_response;
unsigned char TA_response;
unsigned char jobResultNegativeResponse[];
unsigned char index;
//KONSTANTEN
unsigned char EXPECTED_RESPONSE_LENGTH = 11;
unsigned char NEGATIVE_RESPONSE_LENGTH = 10;
request_to_TAS[4] = TA;
expectedResponse[4] = TA;
// ---------------- Argumente des Jobs auswerten ---------------------
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TAS_address, TA_TYPE_PHYSICAL, request_to_TAS, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request_to_TAS;
if (_RESPONSE)
_RESPONSE = response;
if(datalen(response) == NEGATIVE_RESPONSE_LENGTH)
{
if((response[7] = 0x7f) && (response[8] = 0x86))
{
tabset("JobResult");
index = response[9];
tab_suche_unsigned("SB",index);
tabget(jobResultNegativeResponse,"STATUS_TEXT");
JOB_STATUS = jobResultNegativeResponse;
return;
}
}
if(datalen(response) != EXPECTED_RESPONSE_LENGTH)
{
JOB_STATUS = "ERROR_ECU_INCORRECT_LEN";
return;
}
else if(datacmp(expectedResponse,response)!=0)
{
JOB_STATUS = "ERROR_INTERPRETATION";
return;
}
else
{
JOB_STATUS = "OKAY";
}
}
// end of : #include "UDS_86_45_02_STEUERN_ROE_PERSISTENT_START.B2S"
// end of : #include "UDS_JOBS_ROE.B2S"
// Standard Codier-Jobs
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_37_FE_CPS_LESEN.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : CPS_LESEN
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// -------------------------------------------------------------------
// History:
// 15.02.2006 gh V0.001 Erstellung
// 15.03.2007 rd V0.002 dataclear hinzu
// *******************************************************************
// UDS_22_37_FE_CPS_LESEN.B2S @(#)@ V0.002@(#)@
// *******************************************************************
job ( name : CPS_LESEN;
comment : Codierpruefstempel lesen;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $37FE DataIdentifier Codierpruefstempel;
comment : Modus: Default;
result : CPS;
type : string;
comment : Codierpruefstempel 7-stellig;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// Variablen fuer Kommunikation
unsigned char request[] = {0x22, 0x37, 0xFE};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// Variablen fuer Job
unsigned char cps_temp[];
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
if (CPS) {
dataclear(cps_temp);
datacopy(cps_temp, response, 3, 7);
CPS = cps_temp;
}
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_22_37_FE_CPS_LESEN.B2S"
// Standard Flash-Jobs
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_F1_86_DIAG_SESSION_LESEN.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : DIAG_SESSION_LESEN
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// Anforderer : W 2.4, Richard Kolbeck (fuer LDM)
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// Lastenheft L6 Flash-Programmierung Teil 5 (SAP 10000970)
// -------------------------------------------------------------------
// History:
// 12.03.2007 gh V0.001 Erstellung
// 26.03.2007 gh V0.002 Entfernung Argument SG_Adresse
// *******************************************************************
// UDS_22_F1_86_DIAG_SESSION_LESEN.B2S @(#)@ V0.002@(#)@
// *******************************************************************
job ( name : DIAG_SESSION_LESEN;
comment : Aktive Diagnose-Session auslesen;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $F186 ActiveDiagnosticSession;
comment : Modus: Default;
result : DIAG_SESSION_WERT;
type : int;
comment : Diagnose-Session (1 Byte);
result : DIAG_SESSION_TEXT;
type : string;
comment : Diagnose-Session als Text;
result : DIAG_DETAIL_WERT;
type : int;
comment : Details zur Diagnose-Session (1 Byte);
result : DIAG_DETAIL_TEXT;
type : string;
comment : Details zur Diagnose-Session als Text;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// Variablen fuer Kommunikation
unsigned char request[] = {0x22, 0xF1, 0x86};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// spezifische Variablen
unsigned int diag_session;
unsigned int diag_detail;
unsigned char diag_text[];
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
diag_session = response[3];
if (DIAG_SESSION_WERT)
DIAG_SESSION_WERT = diag_session;
diag_detail = response[4];
if (DIAG_DETAIL_WERT)
DIAG_DETAIL_WERT = diag_detail;
if (DIAG_SESSION_TEXT) {
if (diag_session == 0x00)
diag_text = "ISO SAE reserved";
else if (diag_session == 0x01)
diag_text = "Default Session";
else if (diag_session == 0x02)
diag_text = "Programming Session";
else if (diag_session == 0x03)
diag_text = "Extended Diagnostic Session";
else if (diag_session == 0x04)
diag_text = "Savety System Diagnostic Session";
else if ((diag_session >= 0x05) && (diag_session <= 0x3F))
diag_text = "ISO SAE reserved";
else if (diag_session == 0x41)
diag_text = "Coding Session";
else if (diag_session == 0x42)
diag_text = "SWT Session";
else if ((diag_session >= 0x43) && (diag_session <= 0x5F))
diag_text = "Vehicle Manufaturer Specific";
else if ((diag_session >= 0x60) && (diag_session <= 0x7E))
diag_text = "System Supplier Specific";
else
diag_text = "Fehler: unerlaubter Wert (reserved)";
DIAG_SESSION_TEXT = diag_text;
}
if (DIAG_DETAIL_TEXT) {
if (diag_session == 0x01) { // Default Session
if (diag_detail == 0x00)
diag_text = "Bootloader";
else if ((diag_detail >= 0x01) && (diag_detail <= 0x80))
diag_text = "reservierter Bereich";
else if (diag_detail == 0x81)
diag_text = "Applikation: Flash-Mode deaktiviert";
else if (diag_detail == 0x82)
diag_text = "Applikation: Flash-Mode aktiviert";
else
diag_text = "reservierter Bereich";
}
else if (diag_session == 0x02) { // Programming Session
if (diag_detail == 0x00)
diag_text = "reservierter Bereich";
else if (diag_detail == 0x01)
diag_text = "verriegelt";
else if (diag_detail == 0x02)
diag_text = "entriegelt";
else if (diag_detail == 0x03)
diag_text = "Fingerprint geschrieben";
else if (diag_detail == 0x04)
diag_text = "Speicher geloescht";
else if (diag_detail == 0x05)
diag_text = "Download gestartet";
else if (diag_detail == 0x06)
diag_text = "Transfer Data";
else if (diag_detail == 0x07)
diag_text = "Download abgeschlossen";
else if (diag_detail == 0x08)
diag_text = "Speicher ueberprueft";
else if (diag_detail == 0x09)
diag_text = "Programmier-Abhaengigkeiten ueberprueft";
else if ((diag_detail >= 0x0A) && (diag_detail <= 0x7F))
diag_text = "reservierter Bereich";
else
diag_text = "unerlaubter Wert";
}
else if (diag_session == 0x03) { // Extended Diagnostic Session
if (diag_detail == 0x00)
diag_text = "Bootloader";
else if ((diag_detail >= 0x01) && (diag_detail <= 0x7F))
diag_text = "reservierter Bereich";
else if (diag_detail == 0x80)
diag_text = "Applikation: reservierter Bereich";
else if (diag_detail == 0x81)
diag_text = "Applikation: Extended Session gestartet";
else if (diag_detail == 0x82)
diag_text = "Applikation: Extended Session DTCOff_1";
else if (diag_detail == 0x83)
diag_text = "Applikation: Extended Session NDC disabled";
else if (diag_detail == 0x84)
diag_text = "Applikation: Extended Session Flash-Mode aktiviert";
else if (diag_detail == 0x85)
diag_text = "Applikation: Extended Session DTCOff_2";
else if ((diag_detail >= 0x86) && (diag_detail <= 0xFE))
diag_text = "Applikation: reservierter Bereich";
else
diag_text = "Applikation: else application state";
}
else
diag_text = "keine Detail-Information vorhanden";
DIAG_DETAIL_TEXT = diag_text;
}
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_22_F1_86_DIAG_SESSION_LESEN.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_25_04_FLASH_TP_LESEN.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : FLASH_TP_LESEN
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// Anforderer : W 2.4, Richard Kolbeck (fuer LDM)
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// Lastenheft L6 Flash-Programmierung Teil 5 (SAP 10000970)
// -------------------------------------------------------------------
// History:
// 12.03.2007 gh V0.001 Erstellung
// 26.03.2007 gh V0.002 Entfernung Argument SG_Adresse
// 28.03.2007 gh V0.003 mit/ohne Format-Byte
// 04.04.2007 gh V0.004 Reihenfolge bei 18-Byte-Antwort korrigiert
// *******************************************************************
// UDS_22_25_04_FLASH_TP_LESEN.B2S @(#)@ V0.004@(#)@
// *******************************************************************
job ( name : FLASH_TP_LESEN;
comment : Flash Timing Parameter auslesen;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $2504 FlashTimingParameter;
comment : Modus: Default;
result : FLASH_LOESCHEN;
type : int;
comment : EraseMemoryTime (2 Byte);
result : FLASH_TEST;
type : int;
comment : CheckMemoryTime (2 Byte);
result : FLASH_BOOT;
type : int;
comment : BootloaderInstallationTime (2 Byte);
result : FLASH_AUTHENT;
type : int;
comment : AuthenticationTime (2 Byte);
result : FLASH_RESET;
type : int;
comment : ResetTime (2 Byte);
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// Variablen fuer Kommunikation
unsigned char request[] = {0x22, 0x25, 0x04};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// spezifische Variablen
unsigned int format_byte;
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
if (datalen(response) == 13) // ohne Format-Byte
format_byte = 0;
else if (datalen(response) == 18)
format_byte = 1;
else {
JOB_STATUS = "ERROR_INTERPRETATION";
return;
}
// Reihenfolge nach LH Flash-Programmierung Teil 5 (SAP 10000970) V07:
// Antwort mit 13 Bytes:
// 1. FLASH_LOESCHEN
// 2. FLASH_TEST
// 3. FLASH_BOOT
// 4. FLASH_AUTHENT
// 5. FLASH_RESET
//
// Antwort mit 18 Bytes:
// 1. FLASH_LOESCHEN
// 2. FLASH_TEST
// 3. FLASH_AUTHENT
// 4. FLASH_RESET
// 5. FLASH_BOOT
if (FLASH_LOESCHEN) {
if (format_byte)
FLASH_LOESCHEN = (response[4] << 8) + response[5]; // 1.
else
FLASH_LOESCHEN = (response[3] << 8) + response[4]; // 1.
}
if (FLASH_TEST) {
if (format_byte)
FLASH_TEST = (response[7] << 8) + response[8]; // 2.
else
FLASH_TEST = (response[5] << 8) + response[6]; // 2.
}
if (FLASH_BOOT) {
if (format_byte)
FLASH_BOOT = (response[16] << 8) + response[17]; // 5.
else
FLASH_BOOT = (response[7] << 8) + response[8]; // 3.
}
if (FLASH_AUTHENT) {
if (format_byte)
FLASH_AUTHENT = (response[10] << 8) + response[11]; // 3.
else
FLASH_AUTHENT = (response[9] << 8) + response[10]; // 4.
}
if (FLASH_RESET) {
if (format_byte)
FLASH_RESET = (response[13] << 8) + response[14]; // 4.
else
FLASH_RESET = (response[11] << 8) + response[12]; // 5.
}
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_22_25_04_FLASH_TP_LESEN.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_25_02_PROG_ZAEHLER_LESEN.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : PROG_ZAEHLER_LESEN
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// Anforderer : W 2.4, Richard Kolbeck (fuer LDM)
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// Lastenheft L6 Flash-Programmierung Teil 5 (SAP 10000970)
// -------------------------------------------------------------------
// History:
// 12.03.2007 gh V0.001 Erstellung
// 26.03.2007 gh V0.002 Entfernung Argument SG_Adresse
// 26.03.2007 gh V0.002 2 zus<75>tzliche Results bzgl. PROG_ZAEHLER_STATUS
// 26.03.2007 gh V0.002 Korrektur Resultzuweisung PROG_ZAEHLER
// *******************************************************************
// UDS_22_25_02_PROG_ZAEHLER_LESEN.B2S @(#)@ V0.002@(#)@
// *******************************************************************
job ( name : PROG_ZAEHLER_LESEN;
comment : Programmierzaehler lesen;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $2502 ProgrammingCounter;
comment : Modus: Default;
result : PROG_ZAEHLER_STATUS_WERT;
type : int;
comment : Status, wie oft das SG programmierbar ist;
result : PROG_ZAEHLER_STATUS_TEXT;
type : string;
comment : Status, wie oft das SG programmierbar ist;
result : PROG_ZAEHLER;
type : int;
comment : Programmierzaehler;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// Variablen fuer Kommunikation
unsigned char request[] = {0x22, 0x25, 0x02};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// spezifische Variablen
unsigned int prog_zaehler_stat;
unsigned char prog_zaehler_stat_text[];
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
prog_zaehler_stat = response[4];
if (PROG_ZAEHLER_STATUS_WERT)
PROG_ZAEHLER_STATUS_WERT = prog_zaehler_stat;
if (PROG_ZAEHLER_STATUS_TEXT) {
if (prog_zaehler_stat == 0x00)
prog_zaehler_stat_text = "Status gr<67>n: SG mehrfach programmierbar";
else if (prog_zaehler_stat == 0x01)
prog_zaehler_stat_text = "Status gelb: SG mindestens einmal programmierbar";
else if (prog_zaehler_stat == 0x02)
prog_zaehler_stat_text = "Status rot: SG nicht mehr programmierbar";
else
prog_zaehler_stat_text = "Fehler: unerlaubter Wert (reserved)";
PROG_ZAEHLER_STATUS_TEXT = prog_zaehler_stat_text;
}
if (PROG_ZAEHLER)
PROG_ZAEHLER = (response[5] << 8) + response[6];
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_22_25_02_PROG_ZAEHLER_LESEN.B2S"
// start of : #include "X:\REFERENZ\EDIABAS\INCLUDE\UDS_22_25_03_PROG_MAX_LESEN.B2S"
// *******************************************************************
//
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
//
// -------------------------------------------------------------------
// Jobname : PROG_MAX_LESEN
// -------------------------------------------------------------------
// Globale Tabelle : JobResult
// -------------------------------------------------------------------
// Anforderer : W 2.4, Richard Kolbeck (fuer LDM)
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft Diagnose Ausgabe 8 (SAP 10000786)
// Lastenheft L6 Flash-Programmierung Teil 5 (SAP 10000970)
// -------------------------------------------------------------------
// History:
// 12.03.2007 gh V0.001 Erstellung
// 26.03.2007 gh V0.002 Entfernung Argument SG_Adresse
// 11.10.2007 gh V0.003 Result PROG_MAX: int => long
// *******************************************************************
// UDS_22_25_03_PROG_MAX_LESEN.B2S @(#)@ V0.003@(#)@
// *******************************************************************
job ( name : PROG_MAX_LESEN;
comment : Anzahl der maximal m<>glichen Programmiervorg<72>nge auslesen;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $2503 ProgrammingCounter;
comment : Modus: Default;
result : PROG_MAX;
type : long;
comment : maximal m<>gliche Programmiervorg<72>nge;
comment : Sonderfall 0xFFFF: Anzahl der Programmiervorg<72>nge unbegrenzt;
result : JOB_STATUS;
type : string;
comment : OKAY, wenn fehlerfrei;
comment : table JobResult STATUS_TEXT;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// Variablen fuer Kommunikation
unsigned char request[] = {0x22, 0x25, 0x03};
unsigned char SA_response;
unsigned char TA_response;
unsigned char response[];
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
if (PROG_MAX)
PROG_MAX = (response[3] << 8) + response[4];
JOB_STATUS = "OKAY";
}
// end of : #include "UDS_22_25_03_PROG_MAX_LESEN.B2S"
// *******************************************************************
// automatisch generierte Jobs
// *******************************************************************
// *******************************************************************
// SG-spezifische Jobs
// *******************************************************************
// start of : #include "_STATUS_BUILDID_JOBS.b2s"
// start of : #include "_STATUS_BUILD_ID_JOBS.b2s"
/*********************** _STATUS_BUILD_ID_JOBS.b2s ******************************
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
// Ersteller: Martin Flach MicroNova AG i.A. BMW EA-412 +49 89 382 28852
*/
//*******************************************************************
// Jobname : _STATUS_BUILD_ID
//-------------------------------------------------------------------
// Globale Variable : tbd
//-------------------------------------------------------------------
// Globale Tabelle : tbd
//-------------------------------------------------------------------
// Gueltig:
//-------------------------------------------------------------------
//*******************************************************************
job (
name : _STATUS_BUILD_ID;
comment : Gibt die Software-Id zur<75>ck (EntwicklerJob);
result : STAT_HWEL_MC0_TEXT;
type : string;
comment : HWEL-Nr vom mc0;
result : STAT_BTLD_MC0_TEXT;
type : string;
comment : BTLD-Nr vom mc0;
result : STAT_SWEL1_MC0_TEXT;
type : string;
comment : SoftwareNr vom mc0;
result : STAT_SWEL2_MC0_TEXT;
type : string;
comment : DatenNr vom mc0;
result : STAT_BUILDID_MC0_TEXT;
type : string;
comment : BuildId vom mc0;
result : STAT_BUILDDATE_MC0_TEXT;
type : string;
comment : Datum vom mc0-Softwarebuild;
result : STAT_BUILDPC_MC0_TEXT;
type : string;
comment : Name des Rechners auf dem der mc0-Build durchgef<65>hrt wurde;
result : STAT_BUILDUSER_MC0_TEXT;
type : string;
comment : Name des Erstellers des mc0-Builds;
result : STAT_BUILDVERSION_MC0_TEXT;
type : string;
comment : Interne Build-Version vom mc0;
result : STAT_HWEL_MC2_TEXT;
type : string;
comment : HWEL-Nr vom mc2;
result : STAT_BTLD_MC2_TEXT;
type : string;
comment : BTLD-Nr vom mc2;
result : STAT_SWEL1_MC2_TEXT;
type : string;
comment : SoftwareNr vom mc2;
result : STAT_SWEL2_MC2_TEXT;
type : string;
comment : DatenNr vom mc2;
result : STAT_BUILDID_MC2_TEXT;
type : string;
comment : BuildId vom mc2;
result : STAT_BUILDDATE_MC2_TEXT;
type : string;
comment : Datum vom mc2-Softwarebuild;
result : STAT_BUILDPC_MC2_TEXT;
type : string;
comment : Name des Rechners auf dem der mc2-Build durchgef<65>hrt wurde;
result : STAT_BUILDUSER_MC2_TEXT;
type : string;
comment : Name des Erstellers des mc2-Builds;
result : STAT_BUILDVERSION_MC2_TEXT;
type : string;
comment : Interne Build-Version vom mc2;
result : JOB_STATUS;
type : string;
comment : "OKAY", wenn fehlerfrei;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
// ---------------- Variablendeklaration ------------------------------------
unsigned char SA_response;
unsigned char TA_response;
unsigned char request[];
unsigned char response[];
char temp0[];
char temp[];
unsigned int tmp_uint;
unsigned int pos;
unsigned long ul_wert0;
// --------- Haupt-Telegramm -------------
request = {0x22,0x40,0x0B};
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
//***************************************************** MC0
//+++++++++++++++++++++++++++++++ HWEL mc0
// hw-klasse
tmp_uint=0;
pos = 3;
while(tmp_uint<4)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
strcat(temp0,".");
pos = pos+4;
//sgbm-id
dataclear(temp);
hex2ascii(temp, response, pos, 4); // Abholen der Daten
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+4;
//Hauptversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Nebenversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Patchversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
pos = pos+1;
if (STAT_HWEL_MC0_TEXT)
{
STAT_HWEL_MC0_TEXT = temp0;
}
//+++++++++++++++++++++++++++++++++++++++++ BTLD mc0
// hw-klasse
tmp_uint=0;
dataclear(temp0);
while(tmp_uint<4)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
strcat(temp0,".");
pos = pos+4;
//sgbm-id
dataclear(temp);
hex2ascii(temp, response, pos, 4); // Abholen der Daten
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+4;
//Hauptversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Nebenversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Patchversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
pos = pos+1;
if (STAT_BTLD_MC0_TEXT)
{
STAT_BTLD_MC0_TEXT = temp0;
}
//++++++++++++++++++++++++++++++++++++++++++ SWLE1 mc0
// hw-klasse
tmp_uint=0;
dataclear(temp0);
while(tmp_uint<4)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
strcat(temp0,".");
pos = pos+4;
//sgbm-id
dataclear(temp);
hex2ascii(temp, response, pos, 4); // Abholen der Daten
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+4;
//Hauptversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Nebenversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Patchversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
pos = pos+1;
if (STAT_SWEL1_MC0_TEXT)
{
STAT_SWEL1_MC0_TEXT = temp0;
}
//++++++++++++++++++++++++++++++++++++++++++++++++ SWLE2 mc0
// hw-klasse
tmp_uint=0;
dataclear(temp0);
while(tmp_uint<4)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
strcat(temp0,".");
pos = pos+4;
//sgbm-id
dataclear(temp);
hex2ascii(temp, response, pos, 4); // Abholen der Daten
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+4;
//Hauptversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Nebenversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Patchversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
pos = pos+1;
if (STAT_SWEL2_MC0_TEXT)
{
STAT_SWEL2_MC0_TEXT = temp0;
}
if (STAT_BUILDVERSION_MC0_TEXT)
{
ul_wert0 = response[pos];
pos = pos+1;
ul_wert0 = ul_wert0<<8;
ul_wert0 |= response[pos];
pos = pos+1;
uitoad(temp0, ul_wert0);
STAT_BUILDVERSION_MC0_TEXT = temp0;
}
//BuildId mc0
tmp_uint=0;
while(tmp_uint<20)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
if (STAT_BUILDID_MC0_TEXT)
{
STAT_BUILDID_MC0_TEXT = temp0;
}
pos = pos+20;
//BuildDate mc0
tmp_uint=0;
while(tmp_uint<11)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
if (STAT_BUILDDATE_MC0_TEXT)
{
STAT_BUILDDATE_MC0_TEXT = temp0;
}
pos = pos+11;
//BuildPC mc0
tmp_uint=0;
while(tmp_uint<11)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
if (STAT_BUILDPC_MC0_TEXT)
{
STAT_BUILDPC_MC0_TEXT = temp0;
}
pos = pos+11;
//BuildUser mc0
tmp_uint=0;
while(tmp_uint<9)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
if (STAT_BUILDUSER_MC0_TEXT)
{
STAT_BUILDUSER_MC0_TEXT = temp0;
}
pos = pos+9;
//******************************************************************** MC2
//+++++++++++++++++++++++++++++++ HWEL mc2
// hw-klasse
tmp_uint=0;
dataclear(temp0);
while(tmp_uint<4)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
strcat(temp0,".");
pos = pos+4;
//sgbm-id
dataclear(temp);
hex2ascii(temp, response, pos, 4); // Abholen der Daten
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+4;
//Hauptversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Nebenversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Patchversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
pos = pos+1;
if (STAT_HWEL_MC2_TEXT)
{
STAT_HWEL_MC2_TEXT = temp0;
}
//+++++++++++++++++++++++++++++++++++++++++ BTLD mc2
// hw-klasse
tmp_uint=0;
dataclear(temp0);
while(tmp_uint<4)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
strcat(temp0,".");
pos = pos+4;
//sgbm-id
dataclear(temp);
hex2ascii(temp, response, pos, 4); // Abholen der Daten
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+4;
//Hauptversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Nebenversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Patchversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
pos = pos+1;
if (STAT_BTLD_MC2_TEXT)
{
STAT_BTLD_MC2_TEXT = temp0;
}
//++++++++++++++++++++++++++++++++++++++++++ SWLE1 mc2
// hw-klasse
tmp_uint=0;
dataclear(temp0);
while(tmp_uint<4)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
strcat(temp0,".");
pos = pos+4;
//sgbm-id
dataclear(temp);
hex2ascii(temp, response, pos, 4); // Abholen der Daten
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+4;
//Hauptversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Nebenversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Patchversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
pos = pos+1;
if (STAT_SWEL1_MC2_TEXT)
{
STAT_SWEL1_MC2_TEXT = temp0;
}
//++++++++++++++++++++++++++++++++++++++++++++++++ SWLE2 mc2
// hw-klasse
tmp_uint=0;
dataclear(temp0);
while(tmp_uint<4)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
strcat(temp0,".");
pos = pos+4;
//sgbm-id
dataclear(temp);
hex2ascii(temp, response, pos, 4); // Abholen der Daten
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+4;
//Hauptversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Nebenversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
strcat(temp0,".");
pos = pos+1;
//Patchversionsnummer
dataclear(temp);
itoad(temp, response[pos]);
if (strlen(temp) == 1)
strinsert(temp, "00", 0);
if (strlen(temp) == 2)
strinsert(temp, "0", 0);
strcat(temp0,temp);
pos = pos+1;
if (STAT_SWEL2_MC2_TEXT)
{
STAT_SWEL2_MC2_TEXT = temp0;
}
if (STAT_BUILDVERSION_MC2_TEXT)
{
ul_wert0 = response[pos];
pos = pos+1;
ul_wert0 = ul_wert0<<8;
ul_wert0 |= response[pos];
pos = pos+1;
uitoad(temp0, ul_wert0);
STAT_BUILDVERSION_MC2_TEXT = temp0;
}
//BuildId mc2
tmp_uint=0;
while(tmp_uint<20)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
if (STAT_BUILDID_MC2_TEXT)
{
STAT_BUILDID_MC2_TEXT = temp0;
}
pos = pos+20;
//BuildDate mc2
tmp_uint=0;
while(tmp_uint<11)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
if (STAT_BUILDDATE_MC2_TEXT)
{
STAT_BUILDDATE_MC2_TEXT = temp0;
}
pos = pos+11;
//BuildPC mc2
tmp_uint=0;
while(tmp_uint<11)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
if (STAT_BUILDPC_MC2_TEXT)
{
STAT_BUILDPC_MC2_TEXT = temp0;
}
pos = pos+11;
//BuildUser mc2
tmp_uint=0;
while(tmp_uint<9)
{
temp0[tmp_uint] = response[pos+tmp_uint];
tmp_uint = tmp_uint+1;
}
if (STAT_BUILDUSER_MC2_TEXT)
{
STAT_BUILDUSER_MC2_TEXT = temp0;
}
pos = pos+9;
JOB_STATUS = "OKAY";
}
// end of : #include "_STATUS_BUILD_ID_JOBS.b2s"
// end of : #include "_STATUS_BUILDID_JOBS.b2s"
// start of : #include "STATUS_EWS.b2s"
// -------------------------------------------------------------------
// Jobname : STATUS_EWS
// -------------------------------------------------------------------
// Globale Tabelle : StatClientAuthTxt
// StatFreeSkTxt
// StatEwsVerTxt
// -------------------------------------------------------------------
// G<>ltig:
// Lastenheft EWS4_Funktionsbeschreibung (SAP 10001217)
// -------------------------------------------------------------------
// History:
// 09.07.2006 Schl V0.01 Erstellung fuer UDS
// 11.02.2007 Schl V0.02 Argument hinzu, das SG-Adresse selektiert
// 02.05.2007 Schl V0.03 STAT_VERSION f<>r CASCADE sichtbar gemacht
// 24.03.2008 Schl V1.01 STAT_DH_ACTIVE und STAT_E_LABEL_ACTIVE hinzu
// EME hinzu
// 01.07.2008 Schl V1.02 Text Z<>ndung, Einspritzung, Motorlauf entfernt
// "direkt schreiben" in "schreiben" ge<67>ndert
// *******************************************************************
// UDS_22_C0_00_STATUS_EWS.B2S @(#)@ V0.001 @(#)@
// *******************************************************************
job ( name : STATUS_EWS;
comment : Zur<75>cklesen verschiedener interner Stati f<>r EWS;
comment : UDS : $22 ReadDataByIdentifier;
comment : UDS : $C000 Sub-Parameter;
argument : DIAGSG;
type : string;
defrslt : ;
comment : Diagnose Steuerger<65>t zul<75>ssig DME, DME2, EGS, EME;
comment : ohne Eintrag wird Original-Diagnoseadresse verwendet;
comment : Argument kann in endg<64>ltiger SGBD entfernt werden;
result : STAT_EWS3_CAPABLE;
type : int;
comment : 0 Das SG beherrscht kein EWS3;
comment : 1 Das SG beherrscht EWS3;
result : STAT_EWS4_CAPABLE;
type : int;
comment : 0 Das SG beherrscht kein EWS4;
comment : 1 Das SG beherrscht EWS4;
result : STAT_EWS3_ACTIVE;
type : int;
comment : 0 EWS3 ist nicht (mehr) aktiv;
comment : 1 EWS3 ist aktiv (oder l<>sst sich aktivieren);
result : STAT_EWS4_ACTIVE;
type : int;
comment : 0 EWS4 ist nicht aktiv;
comment : 1 EWS4 ist aktiv;
result : STAT_EWS4_SERVER_SK_LOCKED;
type : int;
comment : 0 SecretKey server l<>sst sich noch schreiben;
comment : 1 SecretKey server l<>sst sich nicht mehr schreiben/lesen;
result : STAT_EWS4_CLIENT_SK_LOCKED;
type : int;
comment : 0 SecretKey client l<>sst sich noch schreiben;
comment : 1 SecretKey client l<>sst sich nicht mehr schreiben/lesen;
result : STAT_CLIENT_AUTHENTICATED;
type : int;
comment : 0 Freigabe (noch) nicht erteilt (noch nicht versucht oder Kommunikation gest<73>rt);
comment : 1 Freigabe erteilt (Challenge-Response erfolgreich);
comment : 2 Freigabe abgelehnt (Challenge-Response fehlgeschlagen, falsche Response, Kommunikation i.O.);
comment : 3 nicht definiert;
result : STAT_CLIENT_AUTHENTICATED_TXT;
type : string;
comment : Text zu Status Wert;
result : STAT_DH_ACTIVE;
type : int;
defrslt : ;
comment : 0 Diffie-Hellman-Abgleich nicht aktiv;
comment : 1 Diffie-Hellman-Abgleich aktiv;
result : STAT_E_LABEL_ACTIVE;
type : int;
defrslt : ;
comment : 0 E-Label ist nicht aktiv;
comment : 1 E-Label ist aktiv;
result : STAT_FREE_SK0;
type : int;
comment : 0..0xFD Freie Flashablagen;
comment : 0xFE Freie Flashablage nicht begrenzt;
comment : 0xFF Fehlerkennzeichnung;
result : _STAT_FREE_SK0_TXT;
type : string;
comment : Freie Plaetze;
result : STAT_FREE_SK1;
type : int;
comment : 0..0xFD Freie Flashablagen;
comment : 0xFE Freie Flashablage nicht begrenzt;
comment : 0xFF Fehlerkennzeichnung;
result : _STAT_FREE_SK1_TXT;
type : string;
comment : Freie Plaetze;
result : STAT_VERSION;
type : int;
comment : 0x01 Direktschreiben des SecretKey;
comment : 0x02 Direktschreiben des SecretKey und DH-Abgleich;
result : _STAT_VERSION_TXT;
type : string;
comment : Version;
result : JOB_STATUS;
type : string;
comment : "OKAY", wenn fehlerfrei;
result : _REQUEST;
type : data;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data;
comment : Hex-Antwort von SG;
)
{
unsigned char request[] = {0x22,0xC0,0x00};
unsigned char SA_response;
unsigned char TA_response;
unsigned char TA_copy;
unsigned char response[];
unsigned char stmp[];
int tmp;
unsigned char datenbytes_local[];
// ---------------- Argumente des Jobs auswerten ---------------------
TA_copy = TA;
if (exist(DIAGSG))
{
datenbytes_local = DIAGSG;
if (!datacmp(datenbytes_local, "DME"))
{
TA_copy = 0x12;
}
else if (!datacmp(datenbytes_local, "DME2"))
{
TA_copy = 0x13;
}
else if (!datacmp(datenbytes_local, "EGS"))
{
TA_copy = 0x18;
}
else if (!datacmp(datenbytes_local, "EME"))
{
TA_copy = 0x3A;
}
else
{
JOB_STATUS = "ERROR_DIAGSG";
return;
}
}
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA_copy, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
// ---------------- Interpretation -----------------------------------
if (STAT_EWS3_CAPABLE)
{
STAT_EWS3_CAPABLE = 0;
}
if (STAT_EWS4_CAPABLE)
{
STAT_EWS4_CAPABLE = 1;
}
if (STAT_EWS3_ACTIVE)
{
STAT_EWS3_ACTIVE = 0;
}
if (STAT_EWS4_ACTIVE)
{
STAT_EWS4_ACTIVE = 1;
}
if (STAT_EWS4_SERVER_SK_LOCKED)
{
STAT_EWS4_SERVER_SK_LOCKED = (response[3+0]>>7)&1;
}
if (STAT_EWS4_CLIENT_SK_LOCKED)
{
STAT_EWS4_CLIENT_SK_LOCKED = (response[3+0]>>7)&1;
}
if (STAT_CLIENT_AUTHENTICATED)
{
STAT_CLIENT_AUTHENTICATED = response[3+0]&3;
}
if (STAT_CLIENT_AUTHENTICATED_TXT)
{
tmp = response[3+0]&3;
tabset("StatClientAuthTxt");
tab_suche_index("SB", tmp);
tabget(stmp, "TEXT");
STAT_CLIENT_AUTHENTICATED_TXT = stmp;
}
if (STAT_DH_ACTIVE)
{
STAT_DH_ACTIVE = (response[3+1]>>0)&1;
}
if (STAT_E_LABEL_ACTIVE)
{
STAT_E_LABEL_ACTIVE = (response[3+1]>>1)&1;
}
if (STAT_FREE_SK0)
{
STAT_FREE_SK0 = response[3+8];
}
if (_STAT_FREE_SK0_TXT)
{
tmp = response[3+8];
tabset("StatFreeSkTxt");
tab_suche_index("SB", tmp);
tabget(stmp, "TEXT");
_STAT_FREE_SK0_TXT = stmp;
}
if (STAT_FREE_SK1)
{
STAT_FREE_SK1 = response[3+9];
}
if (_STAT_FREE_SK1_TXT)
{
tmp = response[3+9];
tabset("StatFreeSkTxt");
tab_suche_index("SB", tmp);
tabget(stmp, "TEXT");
_STAT_FREE_SK1_TXT = stmp;
}
if (STAT_VERSION)
{
STAT_VERSION = response[3+15];
}
if (_STAT_VERSION_TXT)
{
tmp = response[3+15];
tabset("StatEwsVerTxt");
tab_suche_index("SB", tmp);
tabget(stmp, "TEXT");
_STAT_VERSION_TXT = stmp;
}
if (_REQUEST)
_REQUEST = request;
if (_RESPONSE)
_RESPONSE = response;
JOB_STATUS = "OKAY";
}
// end of : #include "STATUS_EWS.b2s"
// start of : #include "STEUERN_MONTAGEMODUS_JOBS.b2s"
/*********************** STEUERN_MONTAGEMODUS.b2s ******************************
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
// Ersteller: Berger Carsten P&Z EA-410 089-382-37279
// Datum der Erstellung: 14.04.10 11:33
*/
//*******************************************************************
// Jobname : STEUERN_MONTAGEMODUS
//-------------------------------------------------------------------
// Globale Variable : tbd
//-------------------------------------------------------------------
// Globale Tabelle : tbd
//-------------------------------------------------------------------
// Gueltig:
//-------------------------------------------------------------------
//*******************************************************************
job (
name : STEUERN_MONTAGEMODUS;
comment: 0x3101F043 STEUERN_MONTAGEMODUS;
comment : Ansteuern Montage-Modus. ;
result : JOB_STATUS;
type : string; defrslt : ;
comment : "OKAY", wenn fehlerfrei;
result : _REQUEST;
type : data; defrslt : ;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data; defrslt : ;
comment : Hex-Antwort von SG;
)
{
unsigned char SA_response;
unsigned char TA_response;
unsigned char request[];
unsigned char response[];
// --------- Haupt-Telegramm -------------
request = {0x31,0x01,0xf0,0x43};
// ------ BEGINN Argumente -------------------------------------------
// ------ ENDE Argumente ---------------------------------------------
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
if (_REQUEST) _REQUEST = request;
if (_RESPONSE) _RESPONSE = response;
// ------ BEGINN Results ---------------------------------------------
// ------ ENDE Results -----------------------------------------------
JOB_STATUS = "OKAY";
}
// end of : #include "STEUERN_MONTAGEMODUS_JOBS.b2s"
// start of : #include "STEUERN_ENDE_MONTAGEMODUS_JOBS.b2s"
/*********************** STEUERN_ENDE_MONTAGEMODUS.b2s ******************************
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
// Ersteller: Berger Carsten P&Z EA-410 089-382-37279
// Datum der Erstellung: 14.04.10 11:33
*/
//*******************************************************************
// Jobname : STEUERN_ENDE_MONTAGEMODUS
//-------------------------------------------------------------------
// Globale Variable : tbd
//-------------------------------------------------------------------
// Globale Tabelle : tbd
//-------------------------------------------------------------------
// Gueltig:
//-------------------------------------------------------------------
//*******************************************************************
job (
name : STEUERN_ENDE_MONTAGEMODUS;
comment: 0x3102F043 STEUERN_ENDE_MONTAGEMODUS;
comment : Ende Montage-Modus;
result : JOB_STATUS;
type : string; defrslt : ;
comment : "OKAY", wenn fehlerfrei;
result : _REQUEST;
type : data; defrslt : ;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data; defrslt : ;
comment : Hex-Antwort von SG;
)
{
unsigned char SA_response;
unsigned char TA_response;
unsigned char request[];
unsigned char response[];
// --------- Haupt-Telegramm -------------
request = {0x31,0x02,0xf0,0x43};
// ------ BEGINN Argumente -------------------------------------------
// ------ ENDE Argumente ---------------------------------------------
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
if (_REQUEST) _REQUEST = request;
if (_RESPONSE) _RESPONSE = response;
// ------ BEGINN Results ---------------------------------------------
// ------ ENDE Results -----------------------------------------------
JOB_STATUS = "OKAY";
}
// end of : #include "STEUERN_ENDE_MONTAGEMODUS_JOBS.b2s"
// start of : #include "STATUS_MONTAGEMODUS_JOBS.b2s"
/*********************** STATUS_MONTAGEMODUS.b2s ******************************
// ! ! ! ! ! DIESE DATEI DARF N I C H T VER<45>NDERT WERDEN ! ! ! ! !
// Ersteller: Berger Carsten P&Z EA-410 089-382-37279
// Datum der Erstellung: 14.04.10 11:33
*/
//*******************************************************************
// Jobname : STATUS_MONTAGEMODUS
//-------------------------------------------------------------------
// Globale Variable : tbd
//-------------------------------------------------------------------
// Globale Tabelle : tbd
//-------------------------------------------------------------------
// Gueltig:
//-------------------------------------------------------------------
//*******************************************************************
job (
name : STATUS_MONTAGEMODUS;
comment: 0x3103F043 STATUS_MONTAGEMODUS;
comment : Auslesen Montage-Modus;
result : STAT_FS_MONTAGEMODUS_TEXT;
type : string; defrslt : ;
comment : FUNKTIONSSTATUS MONTAGEMODUS;
comment : 1BYTE FUNKTIONSSTATUS ;
result : STAT_FS_MONTAGEMODUS_WERT;
type : int; defrslt : ;
comment : FUNKTIONSSTATUS MONTAGEMODUS;
comment : 1BYTE FUNKTIONSSTATUS ;
result : STAT_ST_MONTAGE_MODUS_TEXT;
type : string; defrslt : ;
comment : Status Montage-Modus aktiv/inaktiv;
comment : 1BYTE STATUS MONTAGE_MODUS ;
result : STAT_ST_MONTAGE_MODUS_WERT;
type : int; defrslt : ;
comment : Status Montage-Modus aktiv/inaktiv;
comment : 1BYTE STATUS MONTAGE_MODUS ;
result : JOB_STATUS;
type : string; defrslt : ;
comment : "OKAY", wenn fehlerfrei;
result : _REQUEST;
type : data; defrslt : ;
comment : Hex-Auftrag an SG;
result : _RESPONSE;
type : data; defrslt : ;
comment : Hex-Antwort von SG;
)
{
unsigned char SA_response;
unsigned char TA_response;
unsigned char request[];
unsigned char response[];
unsigned char text[];
unsigned long wert_ulong;
// --------- Haupt-Telegramm -------------
request = {0x31,0x03,0xf0,0x43};
// ------ BEGINN Argumente -------------------------------------------
// ------ ENDE Argumente ---------------------------------------------
// ---------------- Kommunikation ------------------------------------
if (!send_and_receive_uds(SA, TA, TA_TYPE_PHYSICAL, request, SA_response, TA_response, response, "", 2)) return;
if (_REQUEST) _REQUEST = request;
if (_RESPONSE) _RESPONSE = response;
// ------ BEGINN Results ---------------------------------------------
if (STAT_FS_MONTAGEMODUS_TEXT || STAT_FS_MONTAGEMODUS_WERT) {
wert_ulong = response[4];
STAT_FS_MONTAGEMODUS_WERT = wert_ulong;
tabset("TAB_AE_FUNKSTAT_MONTAGEMODUS");
tab_suche_unsigned("WERT",wert_ulong);
tabget(text,"TEXT");
STAT_FS_MONTAGEMODUS_TEXT= text;
}
if (STAT_ST_MONTAGE_MODUS_TEXT || STAT_ST_MONTAGE_MODUS_WERT) {
wert_ulong = response[5];
STAT_ST_MONTAGE_MODUS_WERT = wert_ulong;
tabset("TAB_AE_STAT_MONTAGEMODUS");
tab_suche_unsigned("WERT",wert_ulong);
tabget(text,"TEXT");
STAT_ST_MONTAGE_MODUS_TEXT= text;
}
// ------ ENDE Results -----------------------------------------------
JOB_STATUS = "OKAY";
}