bmw-advanced-tools/app/EDIABAS/Bin/Server/mkp-vs/Server.xml

139 lines
4.6 KiB
XML
Raw Permalink Normal View History

2021-09-18 17:45:57 +02:00
<?xml version="1.0"?>
<!DOCTYPE Server SYSTEM "Server.dtd">
<!--
file: Server.xml
purpose: configuration file of Server Windows command line application;
project: CarServer-MKP / Concurrent flash programming of ECUs;
customer: BMW AG / VS-40;
author: Markus A. Stulle, IFS Informationstechnik GmbH;
history: 05/08/18 - file created (SE);
-->
<Server IpSvcAddress="127.0.0.1" TcpSvcPort="5033"
IpClntAddress="127.0.0.1" TcpClntPort="5034"
IpAdminAddress="127.0.0.1" TcpAdminPort="5035"
LogFile=".\Server.log"
LogLevel="LOG_WARN"
CsBaseDir=".."
CsExecutable="Server.exe"
CsVoltageFile="progress.txt"
CsVoltageMaxAge="300"
CsAuthorization="Q1NQOmlmczQy"
CsPreStarted="false">
<AccessControl>
<!-- The list of native client addresses
accepted by the Server process: -->
<ClientsAccepted>
<Host IpAddress="127.0.0.1"/>
</ClientsAccepted>
</AccessControl>
<Gateways EcuDescriptionFile="cip_gw"
EcuDescriptionMinVer="1.00"
JobSetGwDisabled="MOST_CAN_GATEWAY_DISABLE"
JobSetGwEnabled="MOST_CAN_GATEWAY_ENABLE"
IgnoreJobStatus="false"/>
<!-- The farm of CarServers to be controlled by
the Server instance;
- an association between CarServer and remote diagnostic
interface will be established dynamically when a client
application calls 'vsPreConcurrent';
- it will be released again, when a concurrent programming
section has been terminated by calling 'vsPostConcurrent'. -->
<CarServer IpAddress="127.0.0.1" TcpSvcPort="5036"
InstanceDir="\mkp-1" ConfigFile="cipb_svc-1.ini"/>
<CarServer IpAddress="127.0.0.1" TcpSvcPort="5038"
InstanceDir="\mkp-2" ConfigFile="cipb_svc-2.ini"/>
<CarServer IpAddress="127.0.0.1" TcpSvcPort="5040"
InstanceDir="\mkp-3" ConfigFile="cipb_svc-3.ini"/>
<CarServer IpAddress="127.0.0.1" TcpSvcPort="5042"
InstanceDir="\mkp-4" ConfigFile="cipb_svc-4.ini"/>
<!-- The class of diagnostic device controlling the interface channels:
- the behaviour of the device itself can be manipulated
by calling EDIABAS jobs defined in an ECU description file; -->
<DiagnosticDevice Moniker="M-OPPS"
IniFile="C:\EDIABAS\BIN\Remote.ini"
InterfaceHandler="REMOTE"
DefaultChannel="DIAGBUS">
<!-- The list of interface channels controlled by this
class of diagnostic devices:
- channels with matching attributes 'CsConcurrency'
can be driven by the same CarServer instance;
- if a client requests an interface channel that cannot
be driven by an existing CarServer instance, Server will
either create a new process or reallocate an idle instance;
- channel arbitration might fail, if an insufficient number
of CarServer entities has been defined;
- given the following description, examples for wellformed
interface identifiers are 'Channel1' and 'Channel2'. -->
<ChannelIdentifiers DevicePrefix=""
VehicleSuffix="">
<Channel Interface="DIAGBUS"
CsConcurrency="1"
RemoteId="Channel1" TesterId="0xF1"/>
<Channel Interface="MOST_CTRL"
CsConcurrency="2"
RemoteId="Channel2" TesterId="0xFA"/>
<Channel Interface="MOST_ASYNC"
CsConcurrency="2"
RemoteId="Channel2" TesterId="250"/>
</ChannelIdentifiers>
<ApiControl EcuDescriptionFile="opps"
EcuDescriptionMinVer="0.004">
<!-- Diagnostic device state queries:
- employ query 'q1' to qualify device capabilities;
if result 'THREADS' equals to '2', device is assumed
to be an M-OPPS; -->
<Query Moniker="q1"
Purpose="DeviceCapabilities">
<EcuJob Name="STATUS_THREADS" Interface="DIAGBUS">
<JobResult Name="THREADS" Value="1" Semantics="SingleChannel"/>
<JobResult Name="THREADS" Value="2" Semantics="MultiChannel"/>
</EcuJob>
</Query>
</ApiControl>
</DiagnosticDevice>